ARCHITECTURAL SPECIFICATIONS AND SUBMISSIONS

Similar documents
Eggers meticulously-crafted door frames are rivaled only by their beauty, quality and lasting performance. Turning nature s beauty into works of art

WHI 90-Minute Rated Veneered Door Frame Installation Instructions

Architectural Casework Description of Work

SECTION FIRE-RATED WOOD JAMBS

SECTION COILING COUNTER DOORS. Display hidden notes to specifier. (Don't know how? Click Here)

Turning nature s beauty into works of art

SECTION SECTIONAL OVERHEAD DOORS 521 SERIES ALUMINUM SECTIONAL OVERHEAD DOORS

SECTION 6. Glass Storefront Doors:

Core and Frame Details

BASIC FIRE DOOR REQUIREMENTS TECHNICAL DATA SHEET NO. 401

City of San Diego, CWP Guidelines

Code of Standard Practice for Timber Frame Structures

SECTION ALUMINUM FRAMED ENTRANCES and STOREFRONTS. System 402 Flush-Glazed Screw Spline Storefront

SECTION PREFORMED METAL STANDING SEAM ROOFING PART 1 - GENERAL 1.1 DESCRIPTION OF WORK

SECTION SERIES 1500 VINYL PATIO DOORS

Subject: DKS Steel Door and Frames Systems, Inc., ITS / Warnock Hersey Procedural Specification, Certification, and Inspection.

SECTION PREFORMED METAL STANDING SEAM ROOFING

CLEAR-DIVISIONS CENTERFOLD

HMMA 810 HOLLOW METAL DOORS HOLLOW METAL MANUAL -87 NAAMM STANDARD FOURTH EDITION METAL DOORS & FRAMES NAAMM 2 NAAMM 2 METAL DOORS & FRAMES

SECTION GUARDA SECURITY WINDOW SCREENS

SECTION METAL WALL PANELS

REPORT NUMBER: MID-001 ORIGINAL ISSUE DATE: JUNE 27, 2012

DIVISION 8, METAL SOUND CONTROL DOOR ASSEMBLIES PART 1 GENERAL 1.1 RELATED DOCUMENTS

Premier & Deluxe 3-Season Room Sliding Glass Door

DOORS HOLLOW METAL MANUAL NAAMM STANDARD NAAMM HMMA METAL DOORS & FRAMES METAL. A Division of

C. Codes and References: Comply with the version year adopted by the Authority Having Jurisdiction.

Installing Window Trim and Door Trim

Sun Windows General Information Sun New Construction Window Installation Instructions

PART 1 GENERAL 1.1 SECTION INCLUDES

INSTRUCTIONS FOR COORDINATION SECTION SOLID SURFACE FABRICATIONS

Delivery Split delivery Off Hr delivery Store off site To tailgate To floor Accepted by

CLEAR-DIVISIONS VARIOFOLD

Technical Data Honeycomb Door Leaf

DIY CABINET REFACING INSTALLATION GUIDE

GUIDELINE SPECIFICATIONS

GigaCrete Specification PlasterMax

SECTION ACOUSTICAL WALL TREATMENT. A. PART A and DIVISION 1 of PART B are hereby made a part of this SECTION.

Basic Fire Door Requirements

A ROAD MAP FOR YOUR CODE, SMOKE BARRIER & SMOKE PARTITION REQUIREMENTS

Specifications. Preformed Metal Wall and Roof Panels. Alcoa Cladding Systems Manufacturing Plant 100 Industrial Boulevard Eastman, Georgia 31023

FF+E Package 1: Casegoods Specifications UCSD NORTH CAMPUS HOUSING, PHASE 1

Packaged Terminal Air Conditioner Wall Sleeve Installation

SECTION STANDING SEAM METAL ROOFING

Fire-Rated Doors and Hardware. A Guide to Field Inspection

Doors and frames. Technical data manual 2015 rev. 8/17/15

March 14, Installation of Bay, Bow and Garden Windows

RACO Interior OfficeFronts. SolutionsII Typical Details. SolutionsII

MASTERFORMAT SPECIFICATION

JANUARY, 2016 TR-7100 Windows (Fixed) 1 EC ALUMINUM WINDOWS Guide Specs

09/07/07 GLASSFIBER REINFORCED CEMENT (GRC) C. S. I. Spec Master Spec Page 1

A D D E N D U M # 3 QUESTIONS FROM BIDDERS: DATE: November 5, All Bidders. Jenne dos Santos, CBI Consulting Inc. City of Chelsea, MA

Sash Replacement Guide

Preformed Metal Roofing and Siding

Product Guide Specification

SECTION STANDING SEAM METAL ROOF

CLEAR-DIVISIONS APERTO

Basic Technical Fundamentals of Builders Hardware Mortise, Bored and Auxiliary Locks

DE Frame with C Series Sidelight

ST. MONICA FOOD PANTRY HOUSTON, TEXAS

2.02. Specifications. General. Products. Execution. Offset Pivots P-694 Top and Bottom Pivots

Basic Technical Fundamentals of Builders Hardware

ELECTRICAL CONTRACTORS THE UNIVERSITY OF TENNESSEE KNOXVILLE, TENNESSEE SECTION PAGE 1

CONTEMPORARY - TRANSITIONAL RECEPTION STATIONS

AAMA/WDMA/CSA 101/I.S.2/A TEST REPORT. Rendered to: EAGLE WINDOW & DOOR COMPANY

INSTALLATION INSTRUCTIONS for Bifold Doors (JII103)

SECTION COLD-FORMED METAL DECK FRAMING Elevations Steel Deck Framing by Trex

ENGINEERING SPECIFICATION FIBERGRATE MOLDED GRATING. January 24,

INSTALLATION INSTRUCTION - INSTRUCCIONES DE INSTALACION FOR DOUBLE-HUNG VENT REPLACEMENT WINDOW

Wood Sound Retardant Door Hardware Information Bulletin

Installation Instructions Double-Hung, Single-Hung, Casement, Awning, Sliding, Picture & Shapes Non-Impact & Impact Resistant Nailing Fin Windows

3-Part Specification Railing Cable Systems

Active and Passive Sash Replacement

Installation Instructions and Ordering Information

Section EXTERIOR STONE VENEER Full Mortar

Basement Window Installation Guide Hopper and Sliding

Scottsdale, Arizona. Presentation by: Hermes Norero, P.E. President and CEO

PERFORMANCE TEST REPORT. Rendered to: GLASSCRAFT DOOR COMPANY

Pre-Cut Sauna Specifications

RACQUETBALL, HANDBALL OR SQUASH COURTS AND GYMNASIUM WALL SURFACES

Barewood Octagon and Elongated Windows Installation Instructions

WHOLESALE HARDWOOD INTERIORS SOLID WOOD DOORS

Composite Stone Veneer

VA25014B0516 VA CINCINNATI PROJECT NO INPATIENT BED TOWER ADDITION (4 TH AND 5 TH FLOORS) SECTION GYPSUM BOARD

MIDMARK DENTAL CABINETRY vs LOCAL CABINET MAKERS

Steel Door Institute. Fire Rated Doors and Frames

Sapa: SECTION ARCHITECTURAL ALUMINUM HANDRAILS AND RAILINGS

FIRE/LIFE SAFETY CLOSERS/HOLDERS SERIES

Inspecting to a higher standard.

HOW TO INSTALL A BEAUTIFUL NEW KITCHEN

SAMPLE INSTRUCTIONS. Best Barns USA Assembly Book. the Denver. 12'x 12' or 12'x16' Revised November 29, 2010

Total Quantity: IMPORTANT: Plans are to be used with 3 x6 Plexiglass (SKU # ).

AZEK Rail Install Guide

Office of the State Fire Marshal. Fire Rated Doors

DIVISION 00 - PROCUREMENT AND CONTRACTING REQUIREMENTS

Tundra Series Windows January 2016

quality door and window systems for metal buildings

Enhancing The Beauty And Value Of Your Home. Exclusive Patio Door Collection. NORTH STAR PATIO DOOR COLLECTION Two-Panel Three-Panel Four-Panel

SECTION ELECTRO-MECHANICAL HARDWARE

Approved Document Q: Security

Built to Last. Built for Beauty. Good. Solid. Logix. TM

Transcription:

ARCHITECTURAL SPECIFICATIONS AND SUBMISSIONS The following section contains a basic specification guide that can be adapted to your specific job requirement. This specification is for interior, exterior & rated doors. Some minor adjustments may need to be made to this specification to suite your specific needs. We are always willing to help in any way, just call our office for any support required. We have also included our standard submittal cover sheet and following pages to help aid your company in submitting Harring Doors. We have supplied a sample of how we think a good submittal should be entered. The last pages are for substitution requests that may be required from time to time. The first single page could be used prior to the job bidding. The second two pages could be used after the job has bid and we could supply due to time restraints or savings to the owner. SPECIFICATIONS - 1 TOLL FREE 1-888-689-0683 TEL 1-519-644-2444 FAX 1-519-644-2520

PART 1 GENERAL 1.01 WORK INCLUDED SECTION 08210 (New 2004 Masterformat number will be 081433) STILE AND RAIL WOOD DOORS A. Furnish stile and rail wood doors as described in door schedule and shown on drawings. General and Supplementary Conditions as described in Division 1 apply to this Section. 1.02 RELATED SECTIONS A. Flush Wood Doors, Section 08210 B. Metal Doors and Frames, Section 08110 C. Millwork and Trim, Section 06200 D. Finish Hardware, Section 08710 E. Glazing, Section 08800 F. Painting, Section 09900 1.03 REFERENCES A. AWI/AWMAC Quality Standards Illustrated (QSI), current edition B. ANSI/W.D.M.A Quality Standards current edition C. Underwriters Laboratories, Inc. (UL) and Underwriters Laboratories of Canada (ULC): 1. UL 10B Fire Tests of Door Assemblies 2. UL 10C-1998 Positive Pressure Fire Test of Door Assemblies. D. National Fire Protection Agency (NFPA) 1. NFPA 80 Fire Doors and Windows 2. NFPA 252 Standard Method of Fire Tests for Door Assemblies.

E. ASTM International: 1. ASTM E152 Standard Methods of Fire Tests of Door Assemblies. 2. ASTM E2074 Standard Test Method for Fire Tests of Door Assemblies, Including Positive Pressure Testing of Side- Hinged and Pivoted Swinging Door Assemblies. F. Warnock-Hersey International-Intertek Testing 1. Directory of Certification Listings for Fire Doors. 1.04 SUBMITTALS A. Comply with Division 1 - Section 01300 submit 6 complete schedules including shop drawings for approval. B. Indicate plans and elevations, materials, surface grain directions, profiles, assembly methods, joint details, fastening methods, accessories, hardware compliance with specified fire-retardant treatments, preservative treatments, and schedule of finishes. C. Submit 3 samples of veneer, minimum of 6 x 6 illustrating expected range of component finish color and/or grain. The sample shall bear identification of the project, architect or designer, general contractor, woodwork manufacturer, items to which the finish applies and the system utilized to attain the finish. 1.05 QUALITY ASSURANCE A. Perform work in accordance with AWI Section 1400 [Premium] [Custom] [Economy] Grade quality. (choose one) B. Work in this section shall comply with the specified Grade(s) of Work and Section (s) of the current edition of the AWI/AWMAC Quality Standards Illustrated or the current edition of W.D.M.A. Quality Standards 1.06 QUALIFICATIONS A. Manufacturers who are members in good standing of the Architectural Woodwork Institute (AWI), Architectural Woodwork Manufacturers Association of Canada (AWMAC) and the Window and Door Manufacturers Association (WDMA) and are familiar with these standards.

1.07 DELIVERY, STORAGE AND HANDLING A. Comply with Division 1- Section 01600. B. Store doors on a flat level surface, in a clean, dry, well ventilated area. Keep doors a minimum of 3 ½ off floor. C. Doors shall not be exposed to excessive heat, moisture, dryness or direct sunlight. D. Break any protective plastic packaging on site to permit ventilation. E. Ensure that the top, bottom and any cut-outs on doors are sealed immediately after removal of protective packaging. F. Handle doors with clean, dry hands and/or gloves. G. Do not drag doors across one another. 1.08 WARRANTY A. Comply with Division 1 Section 01780 B. Provide limited lifetime warranty for interior doors. C. Provide three year warranty for exterior doors if factory finished. D. Include coverage for defective materials, including tolerances for warp and delamination of materials. PART 2 PRODUCTS 2.01 MANUFACTURERS A. Harring Doors B. The Maiman Company C. Eggers Industries D. Approved equal

2.02 DOOR CONSTRUCTION A. Interior non-rated Doors 1. Stiles and rails shall be constructed of LSL core material laminated with a minimum ¾ solid hardwood edge and a minimum 1/16 A grade veneer. 2. Cope and stick joinery of stiles and rails using ½ x 4 dowels. Joints to have a minimum of 1 dowel. 3. Muntin bars shall have ¼ x 2 ½ dowels at every joint. 4. Pressure fit joints using type 2 water resistant glue. 5. Panels shall be manufactured using a 5 ply construction with 1/32 cross banded face veneer. 6. Flat panels shall have a minimum thickness of 5/8 7. Raised panels shall have a minimum thickness of 1 1/8 8. Panel raise shall be constructed of solid lumber (matching face veneer) and rim banded with mitered corners 9. Louvers shall be 3/8 x 2 ¼ solid lumber or solid MDF for paint grade. Louver slats shall be mortised into stiles and assembled individually. B. Exterior Doors 1. Stiles shall be constructed of LSL core material laminated with a minimum 1/16 A grade veneer 2. Rails shall be solid lumber construction 3. Cope and stick joinery of stiles and rails using ½ x 4 dowels. Joints to have a minimum of 1 dowel 4. Muntin bars shall have ¼ x 2 ½ dowels at every joint. 5. Pressure fit joints using type 1 waterproof glue and silicone caulk to prevent moisture penetration. 6. Flat Panels shall be constructed of an exterior grade core with a minimum overall thickness of 5/8. 7. Raised panels shall be constructed of an exterior grade core with a minimum overall thickness of 1 5/8 8. Panel raise shall be constructed of solid lumber (matching face veneer) and rim banded with mitered corners C. Labeled Fire Doors-Specify 20, 45, 60 or 90 minute. Label doors shall conform to one of the following applicable local codes: (choose one) 1. Negative Pressure: Tested to UL10-B, UBC 1994 or ASTM E152 2. Positive Pressure: Tested to UL10-C, UBC 1997 or ASTM E2074

If positive pressure is required, choose the category of compliance desired (choose one) 2.03 FABRICATION Category A: Doors are manufactured with concealed intumescent to eliminate the need for formed metal edges and astragals. Category B: Doors are required to have surface applied intumescent to either the frame or the edge of the door. A. Fabricate to AWI Section 1400 [Premium] [Custom] [Economy] Quality Standards. (choose one) B. Hardware cutouts are to be pre-machined by the manufacturer. Hinge screw pilot holes in mineral core fire doors shall be bored by door manufacturer. C. When necessary to cut and fit on site, provide materials with ample allowance for cutting. Reseal or refinish any machining alterations required at jobsite prior to installation 2.04 FINISHING MATERIALS AND APPEARANCE A. Doors shall be finished at the factory using the manufacturer s standard finishing system in conformance with AWI Quality Standards Section 1500. B. Raised panel tongues are to be stained prior to assembly when color is required. PART 3 EXECUTION 3.01 INSTALLATION A. Install work in accordance with AWI Quality Standards Section 1700 and NFPA 80 Fire Doors and Windows. B. Doors and frames must be installed plumb, square and level. C. Clearance between door edges and door frame shall be a minimum of 1/16 on hinge edge and 1/8 on the latch edge and top rail.

D. Contractors and their personnel engaged in the work shall be able to demonstrate successful experience with work of comparable extent, complexity and quality to that shown and specified. 3.02 ADJUSTING A. Adjust work under provisions of AWI Quality Standards Section 1700. B. Ensure that doors swing freely and do not bind in their frame. Adjust the finish hardware for proper alignment, smooth operation and proper latching without necessary force or excessive clearance. End of Section

SUBMITTED BY APPROVAL STAMP DATE REVISION BY SINGLE DOORS DOOR HANDING CHART PAIR OF DOORS RH RIGHT HAND LH LEFT HAND RIGHT HAND ACTIVE LEFT HAND ACTIVE RHR RIGHT HAND REVERSE BEVEL LHR LEFT HAND REVERSE BEVEL RIGHT HAND REVERSE BEVEL ACTIVE LEFT HAND REVERSE BEVEL ACTIVE SPECIFICATIONS - 2 TOLL FREE 1-888-689-0683 TEL 1-519-644-2444 FAX 1-519-644-2520

SUBSTITUTION REQUEST Request Number: Project: Date: From: To: Specification Title: Proposed Substitution: Manufacturer: Harring Doors 3799 Commerce Rd. London Ont, Can. N6N 1P9 PH: 519-644-2444 FX: 519-644-2520 Attached data includes product description, specifications, drawings and test data adequate for evaluation of the request. The undersigned certifies: Proposed substitution has been fully investigated and determined to be equal to, or superior to, in all aspects of the specified products. An upgraded or equivalent warranty will be furnished for proposed substitution. Proposed substitution will have no adverse effect on other trades and will not affect or delay progress schedule. Proposed substitution does not affect dimensions and/or functional clearances. Submitted By: Address: PH: FX: Signed by: SPECIFICATIONS - 3 TOLL FREE 1-888-689-0683 TEL 1-519-644-2444 FAX 1-519-644-2520

SUBSTITUTION REQUEST Request Number: Project: Date: From: To: Specification Title: Proposed Substitution: Manufacturer: Harring Doors 3799 Commerce Rd. London Ont., Can. N6N 1P9 PH: 519-644-2444 FX: 519-644-2520 Attached data includes product description, specifications, drawings and test data adequate for evaluation of the request. The undersigned certifies: Proposed substitution has been fully investigated and determined to be equal to, or superior to, in all aspects of the specified products. An upgraded or equivalent warranty will be furnished for proposed substitution. Proposed substitution will have no adverse effect on other trades and will not affect or delay progress schedule. Proposed substitution does not affect dimensions and/or functional clearances. Reason for not providing specified material: SPECIFICATIONS - 4 TOLL FREE 1-888-689-0683 TEL 1-519-644-2444 FAX 1-519-644-2520

Harring Doors is an active member of A.W.I. and W.D.M.A. (N.W.W.D.A.) All of their products meet or exceed the specification for the above named project. They have supplied other projects of similar scope and have had favorable results. Harring Doors have been producing standard and custom detailed architectural doors for over the past ten years. Some examples of projects supplied by Harring Doors are Distributed by Distributed by Distributed by Distributed by Distributed by Submitted by: Address: PH: FX: Signed by: SPECIFICATIONS - 5 TOLL FREE 1-888-689-0683 TEL 1-519-644-2444 FAX 1-519-644-2520

CERTIFICATE OF COMPLIANCE Harring Doors hereby certifies that our products listed on quotation number, comply in all aspects set forth in specification number These products are intended for use in the following project, Under no circumstances should these products be used in any other building, or application than for what they were intended. DATE : HARRING DOORS SPECIFICATIONS - 6 TOLL FREE 1-888-689-0683 TEL 1-519-644-2444 FAX 1-519-644-2520