How To Build A Low Voltage Capacitor Lvcp



Similar documents
Low Voltage Products. Low Voltage Capacitor Banks Power Factor Correction Solutions

MEDIUM AND HIGH VOLTAGE CAPACITORS, CAPACITOR BANKS AND SYSTEMS

DYNACOMP The top-class dynamic response compensator

MEDIUM VOLTAGE CE-BF SWITCHBOARDS. UP TO 40.5 kv. CE - BF - C - en - REV

SURGE PROTECTIVE DEVICES

Life Expectancy : Class A Class B Class C Class D 30,000hrs 10,000hrs 3,000hrs 1000hrs

Power factor correction and harmonic filtering. Rectimat 2 Automatic capacitor banks. Catalogue. Building a New Electric World

3.1.1 Full Type Tests & Routine Tests according to Clause 8 2 & Instructions For Installation, Operation & Maintenance

ISIO 200. Binary Input/Output (I/O) Terminal with IEC Interface

MTE SERIES RLW. World REACTORS USER MANUAL PART NO. INSTR 030 REL MTE Corporation

Power Capacitor Units for improved power quality

Actuator-Sensor-Interface

Unified requirements for systems with voltages above 1 kv up to 15 kv

RM4TG20 three-phase network control relay RM4-T - range V

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

R.C.C.B. s two-pole LEXIC

Electronic ballasts for fluorescent lamps Products for special applications. PC BASIC, 4 28 W Electronic ballast for system output < 25 W

Measurement devices Accessories for analogue and digital instruments

pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2, /0.65/0.

DRM75A 230V 20/100A DIN rail single phase two wire energy meter

Low Voltage Products

Film Capacitors for Automotive and Industrial Applications

Catalog EN. Content Transformers for industrial applications

Chrome DIN Rail Power Supply 24V 91.2W 1 Phase (Class II & NEC Class 2) / DRC-24V100W1AZ

ELEKTROTEHNI KO PODJETJE Leskoπkova cesta 12, 1000 Ljubljana, SLOVENIA

/ The personal storage solution for 24H Sun. / Dynamic Peak Manager. / Smart Grid Ready THREE-PHASE

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N

Chrome DIN Rail Power Supply 24V 30W 1 Phase (Class II & NEC Class 2) / DRC-24V30W1AZ

ABB i-bus KNX Switch Actuator, x-fold, 16/20 A, MDRC SA/S x , 2CDG 110 1xx R0011

R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT Spur 2. Spur 1. Zone 1. Zone 0

RM35UA13MW. range V. Main. Product or component type. Relay monitored parameters

Silvertel. Ag Features. 2 Description. Power-over-Ethernet Plus Module. IEEE802.3at and IEEE802.3af compliant. Maximum 30W output power

48 SERIES Relay interface modules 10 A

How To Use The Vacon 0 Machinery

49 Series - Relay interface modules A. Features

SUCCESS EPCOS Capacitors

1 pole, 16 A Screw terminal connection 35 mm rail (EN 60715) mounting. 2 pole, 8 A Screw terminal connection 35 mm rail (EN 60715) mounting

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC A - M8 connector

High Voltage Circuit Breakers 3AP Type 72.5 kv to 800 kv Answers for energy.

Single-phase ( V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable

Thermistor motor protection relays CM-MSS.22 and CM-MSS.23

CEF 9 CEF-S 23 CEF-VT 27 CMF 31 WBP 39 WBT 47 BPS 61

HSP GmbH Zum Handwerkerhof Wendelstein Tel / Fax: / Web: HSP@hsshsp.de NTG-3000.

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

Switch Actuator, 8-fold, 10 A, MDRC AT/S , GH Q R0111

High-ohmic/high-voltage resistors

LED light engine / OLED LED compact. Umodule STARK CLE CLASSIC / CLE CLASSIC umodule CLE

Guidance for upgrading to GB (IEC : 2005, MOD)

SUB Universal water baths SBB Boiling baths JB, PB Unstirred water baths

X and Y Capacitors. Copyright 2008 KEMET

Vario-Series Accessories

Model 1756 Test Lead Kit

Selector Switch Type 08

Distribution Boards & Consumer Units

LC/LCD ranges level controllers

CHARGING STATIONS FOR ELECTRIC VEHICLES QUICK CHARGER

ABB PV + Storage REACT-3.6/4.6-TL 3.6 to 4.6 kw

Electronic timer CT-VBS OFF-delayed without auxiliary voltage, for DC contactors Data sheet

38 Series - Relay interface modules A

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

HERZ-Thermal Actuators

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q R0001

EPM3. Phase Sequence and Motor Rotation Tester. Users Manual

High-ohmic/high-voltage resistors

RIELLO ELETTRONICA. Master HP

WW12X, WW08X, WW06X, WW04X ±1%, ±5% Thick Film Low ohm chip resistors

MasterINTERFACE 39 Series - Relay interface modules

SOHOline and SOHO Slimline The SOHOline and SOHO Slimline offer a modular, sturdy and compact design

Bulletin 150 Smart Motor Controllers SMC-3 Smart Motor Controller

2CP. Twin-impeller pumps PERFORMANCE RANGE INSTALLATION AND USE APPLICATION LIMITS OPTIONALS AVAILABLE ON REQUEST CONSTRUCTION AND SAFETY STANDARDS

LED light engine / OLED LED linear /area. Umodule STARK LLE CLASSIC STARK LLE. Ordering data

38 Series - Relay interface modules A

Low Voltage Products. Low Voltage Capacitors Power Factor Correction Solutions

Linear Luminaire for Fluorescent Lamps Series EXLUX 6001

Low Voltage Switchboards The Best Technical Solution for Your Ship

Type-Tested Power Distribution Board 8PT with Rear Busbars. sivacon

ABB Drives. User s Manual. Pulse Encoder Interface Module RTAC-01

3M Quick Connect System (QCS) 2814

SICONT Limit Switches Type 3SE3 upto 500 VAC, 600 VDC, 10A

Guide for the Design and Production of LV Power Factor Correction Cubicles

Product and Applications Description. Application Programs. Example of Operation. GAMMA instabus Technical Product-Information.


ZS4-SF1-T Screw Clamp Terminal Blocks For 5 x 20 and 5 x 25 fuses - with test socket

Model CS 64 Mini-DIN Cable and Adaptor

CliQ DIN Rail Power Supply 24V 120W 1 Phase / DRP024V120W1AA

SELECTION GUIDE. Nominal Input

Climasys Thermal Management System. Schneider Electric Universal Enclosures 2009

Capacitors for A.C. motor applications

Transformer Bushings for GIS

EGSTON Standard E2xFxWx 12W

Medium Voltage Products. ZN1 12 kv arc-proof air-insulated switchgear for primary distribution

How To Read A Pipe From A Sensor

LV MCC LOW VOLTAGE SWITCHGEAR MOTOR CONTROL CENTRE PRODUCT GUIDE

Product and functional description

MasterINTERFACE 39 Series - Relay interface modules

ARCO Electric Products Installation and Maintenance Manual Low Voltage Automatic Power Factor Correction Capacitor Systems 2013

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description

Kit Watt Audio Amplifier

Molded Case Circuit Breaker Specifications Bulletin Number 140U-D

Transcription:

Low Voltage Capacitor LVCP The new choice for Power Factor Correction

LVCP : the new choice for Power Factor Correction The LVCP is a compact and powerful capacitor. It offers high modularity, unmatched performances and a state of the art integrated protection system. The LVCP is the ideal capacitor for assembly in automatic power factor correction equipment. Terminals sized for common cable shoes Built-in safety discharge resistors (<75V in 3 min.) Enclosure with double casing insulation Interconnection bars External discharge device (<50V in 1min.) Clips system for group assembly Protective cover (IP20 protection) Fixation holes Compact and flexible The LVCP offers high power density and small dimensions. The modular design of the LVCP allows easy and quick assembly of capacitor modules. A wide rating range is covered with only a few different basic units. Parallel connection between units is made easy by means of specially designed interconnection bars. A clips system assures an excellent mechanical strength of the assembled units. The base of the plastic enclosure offers multiple fixation possibilities (through-hole bolts, insertion-hole screws, DIN rail). An easy to fix protective cover (option) allows IP 20 protection. In addition to its built-in safety discharge resistors, the LVCP can be fitted with an external discharge device (option) for a safe discharge to less than 50V in 1 minute after a switch off.

Safe The LVCP protection system offers a reliable fault protection system. Unique double-action safety system The end of life safety system is based on the self-healing capability of the dielectric and the swift reaction of our revolutionary double-action disconnection device combining internal fuse and pressure sensitive disconnector. Double casing insulation The capacitor windings are housed and fixed in an insulating enclosure with double casing insulation. The LVCP construction protects the windings from the environment and assures a high capacitance stability over the whole capacitor service life. Built-in safety discharge resistors The LVCP is fitted with built-in safety discharge resistors. IP 20 protection An easy to fix protective insulating cover (option) allows IP 20 protection. Terminals Built-in safety discharge resistors (<75V in 3 min) Fuse Pressure sensitive disconnector Dry type self-healing capacitor winding Thermo-setting resin Insulating enclosure Reliable In-house metallized film The dielectric of the LVCP windings is made of inhouse metallized polypropylene film giving : high voltage withstand capability excellent peak current handling capacity high capacitance stability long life even under high electrical stress very low losses exceptional self-healing properties Automatized manufacturing process The LVCP automatized manufacturing process results in high reliability, fully controlled performance and a guaranteed repeatable quality. Comprehensive testing The LVCP and its components are comprehensively tested both off and on the line. Testing includes long term ageing, temperature, humidity, dielectric, self-healing, current and voltage tests. ISO 9001 Our ISO 9001 Quality System registration provides the strongest assurance of our product quality. ISO 14001 The LVCP has a dry type dielectric and is free from liquids or other impregnating agents. It has been designed for environmentally friendly manufacturing. Our ISO 14001 certification guarantees our commitment to the environment. Complies with international standards The LVCP capacitor complies with the requirements of the IEC 60831 1 & 2 international standard and is CE marked.

Accessories Interconnection bars (option) Protective insulating cover for IP20 protection (option) External discharge device for a safe discharge to less than 50V in 1 minute after a switch off (option) Clips system for group assembly (option) DIN rail fixation (option) Examples of LVCP module assembly at 400V - 50Hz 12.5 kvar + 12.5 kvar = 25 kvar 15 kvar + 15 kvar + 15 kvar = 45 kvar 15 kvar + 15 kvar = 30 kvar 16.7 kvar + 16.7 kvar + 16.7 kvar = 50 kvar 15 kvar + 20 kvar = 35 kvar 20 kvar + 20 kvar = 40 kvar Note : Interconnection bars supplied as option are capable of withstanding continuously a current of 72 A RMS. Higher LVCP rating configurations are possible using interconnection bars capable of withstanding a higher current.

Technical specification Voltage range 50Hz : 230, 400, 415, 450 and 465V. 60 Hz : 240 and 380V. Connection Discharge resistors Terminals Earth Colour Fixing Execution Protection Maximum ambient temperature Minimum ambient temperature Dielectric losses Total losses 3-phase. Built-in and sized for discharge of the capacitors to less than 75V in 3 min. Tinned copper bars with fixation hole. No earth connection needed. RAL 7035 (dark grey). Through-hole bolts, insertion-hole screws, DIN rail (with optional adaptor). Indoor. IP00. IP 20 with insulating cover. Class D (+55 C). -25 C. < 0.2 Watt/kvar. < 0.5 Watt/kvar (discharge resistors included). Tolerance on capacitance 0 +10 %. Voltage test Acceptable overloads according to IEC 60831 1& 2 Between terminals : 2.15 Un for 10 sec. Overvoltage tolerance : 10 % max. intermittently. Overcurrent tolerance : 30 % permanently. Important : the installation of capacitors on networks disturbed by harmonics may require special precautions, especially when there is a risk of resonance.

Dimensions Without protective insulating cover (mm) With protective insulating cover (mm) Weight (unpacked) : 2.1 kg / LVCP unit (without cover).

Range Voltage/Frequency Power A/phase C N /phase [kvar] [A] [µf] 230V/50Hz 2.5 6.3 49.8 5.0 12.6 99.5 7.5 18.8 149.8 10.0 25.1 200.0 400V/50Hz 5.0 7.2 33.2 7.5 10.8 49.8 10.0 14.4 66.4 12.5 18.0 83.0 15.0 21.7 99.5 16.7 24.1 111.0 20.0 28.9 133.0 415V/50Hz 5.0 7.0 30.8 10.0 13.9 61.6 15.0 20.9 92.4 16.7 23.2 102.7 20.0 27.8 123.3 450V/50Hz 11.7 15.0 61.5 17.6 22.8 92.3 19.6 25.2 103.0 465V/50Hz 11.9 14.8 58.2 17.8 22.1 87.3 19.8 24.6 97.2 240V/60Hz 2.5 6.0 38.5 5.0 12.0 77.0 7.5 18.0 115.0 10.0 24.1 153.0 380V/60Hz 5.0 7.6 30.6 10.0 15.2 61.2 15.0 22.8 91.9 16.7 25.4 102.3 20.0 30.4 122.5

SCS.030.5060G01 ed. 1 99-09 While all care has been taken to ensure that the information contained in this publication is correct, no responsibility can be accepted for any inaccuracy. We reserve the right to alter or modify the information contained herein at any time in the light of technical or other developments. Technical specifications are valid under normal operating conditions only. We do not accept any responsibility for any misuse of the product and cannot be held liable for indirect or consequential damages.