2/2- and 3/2-way directional seated valves type BVG and BVP

Similar documents
3/2- and 2/2-way cartridge valve type BVE

Directional seated valves type VP 1

2/2-, 3/2-, and 4/3-way seated valves type NBVP 16 with industrial standard connection pattern Cetop 3 conforming DIN A6

Electro-hydraulic pressure switches type DG

1. General. D 7490/1 2/2-way cartridge valve EM 2.2. Operation pressure p max Flow Q max. = 450 bar = 160 lpm. Cartridge valve (see section 2)

Flow divider (flow distributor), type TQ

Line rupture protection valves type LB

Directional seated valves Directly actuated, leakagefree for hydraulic systems For the assembly on connection sub-plates

2/2 and 3/2 Way Size 6 Seat Valves

Radial piston pumps type R and RG

2-way flow control valve with sliding throttle type SB and SQ

Fluid. Flu. Fluid Fluid. uid Power d Power P. Fluid Power P. Fluid Power. Fluid Power Power. d Power. Directional Cetop Valves DCV 03.

3/2-way Solenoid Valve, direct-acting, NC or NO

RPE3-04. Functional Description HA /2010. Directional Control Valves Solenoid Operated. Replaces HA /2007

Assisted lift operated 2/2-way solenoid valves Type EV250B

Electrically operated valves Series M-05, 3/2-, 5/2- and 5/3-way G1/8 650 and 750 Nl/min (0.661 and Cv)

Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv)

Single sub-base valve

E4E PILOT OPERATED DIRECTIONAL CONTROL VALVE WITH ELECTRIC PROPORTIONAL CONTROL SERIES 51

3/2-way Mini Solenoid Valve

Cable Plug acc. to DIN EN , Form A

3/2 Solenoid Cartridge Valve, Size 6

Unit 24: Applications of Pneumatics and Hydraulics

3/2-way pneumatic cartridge solenoid valve

DXPE*J /215 ED. DIRECtIONAL CONtROL VALVE PILOt OPERAtED, WItH OBE AND FEEDBACK. Q max (see performance table) SERIES 30

SOLENOID VALVES 3-4 WAY

Cartridge Valves. Solenoid Valves. Vickers. Screw-in Cartridge Valves. Maximum Pressure 210 bar (3000 psi) Maximum Flow 227 l/min (60 USgpm)

4 Posiflow Proportional Solenoid Valves

System 8. ü ( System 8

3 Port Solenoid Valve

Proportional relief valves type AGMZO-TERS, AERS two stage, with integral or remote pressure transducer, ISO 6264 size 10, 20 and 32

Chapter 5: Flow Valves

Pressure reducing valve, direct operated, Type ZDR 6 D

Solenoid valves 2/2-way direct-operated Type EV210A

3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve

2.12. page Products for Explosion hazardous Environment

4/2-Way Pneumatic Solenoid Valve

Electro-pneumatic control valves

Over-center valves type LHK with hydraulic release

3 WAY (3/2) POPPET VALVES FOR AIR AND VACUUM SERVICE SOLENOID OR AIR ACTUATED BROCHURE N-223

SOLENOID VALVES AND PNEUMATIC VALVES

Load-sensing control block in mono and sandwich plate design

Fluid Level Gauge Fluid Level Sensor Temperature Switch FSA / FSK / TS

2011 DC Electropumps Bull. Rotation Ø 15 6,45 3,5 5,7

G1/4 Q8. Standard with biased position

3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve

DSE5J /112 ED DIRECTIONAL VALVE WITH PROPORTIONAL CONTROL FEEDBACK AND INTEGRATED ELECTRONICS SERIES 10 SUBPLATE MOUNTING ISO (CETOP 05)

S GATE KNIFE GATE VALVE WITH PNEUMATIC ACTUATOR

Series 8146/5-V37 and Series 8150/5-V37

type V46, solenoid or pneumatic operated

Chapter 6: Check Valves

D660 Series Servo-Proportional Control Valves with Integrated Electronics ISO 4401 Size 05 to 10

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2...

Pressure relief valves Size 6

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics

Solenoid Operated Directional Valves

2 WAY (2/2) AND 3 WAY (3/2) BRASS AND STAINLESS STEEL SOLENOID VALVES

Check Valves. Pilot Operated Check Valves. Vickers. PCGV-6/8, 10 Series; PCG5V-6/8, 20 Series. Typical Section. Features and Benefits

Solenoid Operated Directional Valves

97300 NAMUR series, 3/2 & 5/2 Indirect solenoid actuated spool valve

Safety for Hydraulics Leak free double check valve, pilot operated, series DERV Cartridge type, two stage

2-way flow control valve Type 2FRM 6

Electric Rotary Actuator - On/Off or programmable control actuator

VSO MAX HP High Flow Proportional Valve

Direct Operated Regulator for 6.0 MPa (Relieving Type) How to Order. Body size 30 40

Pressure Relief. Pressure Control Valve R(C)G(O)-03, 06 and 10; R(C)T(O)-03, 06 and 10 VICKERS. Basic Characteristics. Sectional Illustrations

Valves. Sub-Base Mounted Valves to ISO 5599/2

Pneumatic Control and Shut-off Butterfly Valve Pfeiffer Type BR 14b/31a and Type BR 14c/31a

3-Way heavy duty flow control, with pressure compensated and solenoid controlled priority flow

Steering unit. Table of contents. Features RE 11872/ Type LAGL. Frame sizes 500 to 1000 Component series 1X Maximum flow 80 l/min

Proportional pressure regulators VPPE

Solenoid Valve Type 3962

Explosion proof enclosures

SELECTION, APPLICATION AND MAINTENANCE

Hydraulic Control Solutions

Terminal Boxes in Glass Fiber Reinforced Polyester (GRP)

HERZ-Thermal Actuators

Variable Displacement Pump AA10VSO

Hydraulic Flow Control Valves

KDG3V-5/7/8, 10 Series

3753 en /b VE/B - VE/RG Va V riable speed drives

FLOAT SWITCHES FLOW SWITCHES FOR LIQUIDS PRESSURE SWITCHES

Solenoid Valve Island Type 3965

Rotary Actuators, NAMUR interface VDI/VDE 3845 & ISO 5211 (ATEX certified) Series ARP

PPS-PPQ-BT-PIAS RESIN INSULATORS FOR OIL INSULATED ELECTRICAL MACHINES

MANTA Piston Distributor for Oil and Fluid Grease

2-Way heavy duty flow control, with pressure compensated, solenoid and load sensing controlled priority flow

QLM and QLD Series Three-port Control Valves

Electronic pressure switch with display Model PSD-30, standard version Model PSD-31, with flush diaphragm

STEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase

VP23, 3-way proportional pressure control valves Seat valve with μp-driven pressure control

Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS

Standard Specifications Model. How to Order. Mist spray unit. Recommended Equipment. Mixing valve

4. Combi valves. 7. Fire hydrants. 8. Check valves. 9. Air valves

3 Port Solenoid Valve

ISORIA. Centered disc butterfly valves with AMRING elastomer liner. 240 PSI: 1½ to PSI : 10 to 24

Pressure transmitter For general industrial applications Model A-10

Safety for Hydraulics Leak free check valve, pilot operated, series ERV Cartridge type, two stage

4/4-way servo solenoid directional control valves, directly operated, with electrical position feedback and on-board electronics (OBE)

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

Transcription:

2/2- and 3/2-way directional seated valves type BVG and BVP for any flow direction, zero leakage all ports pressure resistant Perm. pressure p max = 320 bar Perm. flow Q max = 50 lpm Additional valves with same function: ' Type BVG 11(12 and, BVP 11( see appendix, sect. 5.1, Run-out design do not use for new layouts! ' Type BVG, BVP 1 D 7765 (Q max = 20 lpm, p max = 400 bar) ' Type NBVP 16 D 7765 N (Q max = 20 lpm, p max = 400 bar) ' Type BVE D 7921 (Q max = 70 lpm, p max = 400 bar) ' Type VP D 7915 (Q max = 15 lpm, p max = 400 bar) Design for pipe connection Example: Type BVG 3 S-G 24 Design for manifold mounting Example: Type BVP 3 R-G 12 2.2 1. General These 2/2- and 3/2-way directional cone seated valves are available with electrical, hydraulic or pneumatic actuation. All ports are equally pressure resistant due to the internal pressure balance. The zero or idle position is achieved automatically if the valve is not actuated due to spring return. They are of all steel design and all functionally essential internal parts are hardened and run maintenance free in oil; Cones and seats are ground. 1987 by HAWE Hydraulik HAWE HYDRAULIK SE STREITFELDSTR. 25 81673 MÜNCHEN D 7400 Seated valves type BVG(P) 3 January 2007-03

D 7400 page 2 2. Available versions, main data Order examples: BVG 3 R/B 2,5 - WG 230 BVP 3 Z - P Table 1: Basic type and size 1 ) Complete symbols (The actuation symbols apply to all flow symbols) Pipe connection Coding BVG 3 BVP 3 Design and connection Pipe connection G 1/2 ISO 228/1 (BSPP) Manifold mounting Flow Q max (lpm) 50 50 Pressure p max (bar) 320 320 Table 2: Symbols R S Z BVG 3 Z - G... BVG 3 Z - WG... Table 3: Orifices (in ports A, B, and C, see also sect. 3.1) BVG 3 R - H Manifold mounting BVG 3 S - P Coding No. for subsequent orders System or Ø accumulator (mm) BVG 3.. BVP 3.. pressure range B 2,5 2.5 7405 014 b 7405 013 b about 300 bar B 3 3 7405 014 c 7405 013 c about 200 bar B 3,5 3.5 7405 014 d 7405 013 d about 150 bar B 4 4 7405 014 e 7405 013 e about 100 bar 0 2 ) 7405 014 a 7405 013 a -- Table 4: Actuations BVP 3 Z - G... BVP 3 Z - WG... Actuation Coding with plug Plug with LED without plug Main data, see also sect. 3.2 BVP 3 Z - H BVP 3 R(S) - H BVP 3 Z - H 1/4 BVP 3 R(S) - H 1/4 Hydraulic Pneumatic G 12 G 24 WG 110 WG 230 H H 1/4 P L 12 L 24 --- --- X 12 X 24 X 98 X 205 Ext. control port G 1/4 (BSPP). Only with type BVP 3! Ext. control port G 1/4 (BSPP) U N = 12 V DC U N = 24 V DC U N = 110 V AC, 50/60 Hz (98 V DC) 3 ) U N = 230 V AC, 50/60 Hz (205 V DC) 3 ) Control p contr min = 24 bar pressure: p contr max = 320 bar Control p contr min = 2... 3.5 bar pressure: p contr max = 15 bar Actuation Hydraulic Pneumatic symbols Coding H 1/4 Coding H BVP 3 Z - P BVP 3 R(S) - P 1) Type BVG 11(12, and BVP 11( see appendix, sect. 5.1, Run-out design do not use for new layouts! Undrilled for customized diameter acc. to p-q-curve of the orifices, sect. 3.1 3) DC-solenoid (98 V DC, 205 V DC) with plug featuring a bridge rectifier circuit

D 7400 page 3 3. Further parameters 3.1 General and hydraulic Installation position Overlapping with 3/2-way directional valves Operating pressure Static overload capacity Any Negative (transverse of one into the other flow direction is only completed when the switching position is achieved). All passages are interconnected during the switching operation. p max = 320 bar Ports A, B, and C approx. 2 x p max (640 bar) Body material and surface coating Steel, zinc galvanized Mass (weight) approx. kg Complete with actuation BVG 3 R BVG 3 S BVG 3 Z BVP 3 R BVP 3 S BVP 3 Z 2.3 3.3 2.3 2.4 Hydraulic 1.9 2.9 1.9 2.0 Pneumatic 1.9 2.6 1.9 1.7 Pressure fluid Hydraulic oil conforming DIN 51514 part 1 to 3: ISO VG 10 to 68 conforming to DIN 51519. Viscosity limits: min. approx. 4, max. approx. 1500 mm 2 /s; opt. operation approx. 10... 500 mm 2 /s. Also suitable are biological degradable pressure fluids types HEPG (Polyalkylenglycol) and HEES (Synth. Ester) at service temperatures up to approx. +70 C. Temperature Ambient: approx. -40... +80 C Fluid: -25... +80 C, Note the viscosity range! Permissible temperature during start: -40 C (Observe start-viscosity!), as long as the service temperature is at least 20K higher for the following operation. Biological degradable pressure fluids: Note manufacturer s specifications. By consideration of the compatibility with seal material not over +70 C. Attention: Observe the restriction regarding the operation duration in sect. 3.2.! Perm. flow Flow limitation 3/2-wayvalve 2/2-wayvalve Q perm acc. to sect. 2 applies to p max = 320 bar with solenoid actuation in usual pump circuits. With pressure < 150 bar (solenoid actuated) or with all other actuation modes Q perm may be exceeded up to 50% as long as the back pressure is permissible. The max. flow has to be limited (depending on the pressure) by means of orifices in the case of accumulator circuits or if connected to high pressure circuits (circulation lines or central supplies) down to the specified Q max (see sect.. These orifices must be located always on the accumulator side. With valves type..z..- they are installed in port C. If mounting in port A or B is requested, this has to stated in uncoded text. For detailed description see table 3, sect. 2. p-q-curve Basic valve Additional orifices Back pressure p (bar) Back pressure p (bar) Flow Q (lpm) Flow Q (lpm) Viscosity of the oil during tests approx. 60 mm 2 /s

D 7400 page 4 3.2 Actuations The solenoids are manufactured and tested conforming DIN VDE 0580 Coding G 12 G 24 WG 110 WG 230 L 12 L 24 --- --- X 12 X 24 --- --- Nom voltage U N (V) 12 24 110 230 (DC-voltage) (AC-voltage, 50/60 Hz) Nom. power P N (W) 33.2 30.0 32.8 33.0 DC-voltage AC-voltage Type G... Type L.. Type WG.. Plug DIN EN 175 301-803 (circuitry and symbol) All plugs For additional plugs, see D 7163 terminals Switching time (guideline) Switchings / hour ON or OFF: approx. 50... 60 ms; with WG.. approx. 2-3 times prolonged approx. 2000/h to be regarded as approx. evenly distributed Protection class IP 65 (IEC 60529) (plug properly mounted) Insulation material class Contact temperature Cut-off energy Surface coating (solenoid) F approx. 98 C, at 20 C ambient temperature WA 0.5 Ws DIN 50961-Fe/Zn 12 bk cc Ambient temp. } U ( C) Relative duty cycle during service (100% ED stamped on the solenoid) Rel. duty cycle %ED-5 min Control pressure P contr min p contr max Perm. residual pressure in the control line for save return to idle position Static over load capacity of Z Control oil volume (geom.) Housing material and surface coating Hydraulic (Coding H, H 1/4) Pneumatic (Coding P) 24 bar 2 bar 320 bar 15 bar < 2 bar --- approx. 1.5 p contr max bar approx. 1.5 p contr max bar 0.6 cm 3 3 cm 3 Steel (body) Light alloy (body) galv. zinc plated black anodized

D 7400 page 5 4. Unit dimensions All dimensions are in mm and subject to change without notice! 4.1 Version for pipe connection Illustrations are with solenoid actuation (coding G.. or WG..), for other actuations see below Type BVG 3 R(S) Type BVG 3 Z Cable gland approx. 35 1 ) Manual emergency actuation For missing dimensions see below! Ø8.5 thru-hole Ø8.5 thru-hole Ports conf. ISO 228/1 (BSPP): A and B = G 1/2 Ports conf. ISO 228/1 (BSPP): A, B, and C = G 1/2 #5.5 Manual emergency actuation Actuation aid (do not use any sharp-edged parts) The valve may be actuated by pressing down the brass bolt visible from above by means of a steel pin or a screw driver etc. Note: All pressure apparent at port B loads on the cross section of the brass bolt Ø5.5 i.e. 100 bar or 240 N! 1) Note: This dimension is depending on the manufacturer and can be up to max. 40 mm acc. to DIN EN 175 301-803! When required the solenoid may be rotat ed to the valve body by another 4x90 in addition to the standard assembly position illustrated here. Hydraulic actuation Coding H 1/4 Pneumatic actuation Coding P

D 7400 page 6 4.2 Version for manifold mounting Illustrations are with solenoid actuation (coding G.. or WG..), for other actuations see below 4.1 Type BVP 3 R(S) Hydraulic actuation Coding H For missing data see sect. 4.1! Control port Z is at the upper (valve section) Coding H 1/4 M 6, 9 deep 1) Pneumatic actuation Coding P Type BVP 3 Z Sealing of ports A, B, and C via O-rings 13.95x2.62 NBR 90 Sh Port Z: via O-ring 2.54x1.78 NBR 90 Sh For missing data see sect. 4.1! Available as spare part, seal-kit DS 7400-3 incl. O-rings for actuation coding H, H 1/4. 1) Control port Z is only apparent at versions with hydraulic actuation coding H! 1) M 6, 7 deep

D 7400 page 7 5. Appendix 5.1 Type BVG 11(12 and or BVP 11( Run-out design do not use for new layouts! (Alternative, type BVG 1 and BVP 1 acc. to D 7765) Order examples: Symbols (see table 2 sect. Attention: Symbol Z not available BVG 11 R - G 24 for type BVG 12! BVP 2 S/B 1,5 - WG 230 Table 5: Basic type and size Table 7: Actuation modes Coding BVG 11 BVG 12 BVG 2 BVP 11 BVP 2 Design and connection G 1/4 G 3/8 G 3/8 Pipe connection ISO 228/1 (BSPP) Manifold mounting Flow Q max (lpm) 12 20 1 ) 20 12 20 Pressure p max (bar) 320 320 Actuation Coding, note G 12, L 12, X 12 see table 4, G 24, L 24, X 24 sect. 2 WG 100, X 98 WG 230, X 205 G 24 EX 3 ) Ex-proof design U N = 24 V DC; p max = 220 bar! Manual A for type BVG 11(1! Table 6: Basic type BVG 11 BVG 2 BVP 11 BVP 2 Additional orifice (at ports A, B, and C, see also sect. 3.1) Coding B 0,6 B 1,1 B 1,3 B 1,5 B 1,5 B 2,0 B 2,5 B 4,0 B 0,6 B 0,8 B 1,1 B 1,3 B 1,5 B 2,0 B 2,5 Ø (mm) 0.6 1.1 1.3 1.5 0 1.5 2.0 2.5 4.0 0 0.6 0.8 1.1 1.3 1.5 2.0 2.5 0 for subsequent orders 7406 012 b 7406 012 d 7406 012 f 7406 012 h 7406 012 a 7400 003 c 7400 003 f 7400 003 i 7400 003 b 7400 003 a 7400 004 g 7400 004 e 7400 004 b 7400 004 d 7400 004 c 7400 004 f 7400 004 i 7400 004 a Further parameters For general and electrical data see sect. 3.1 or 3.2 Mass (weight) approx. kg Complete with actuation Manual BVG 11 R(S) BVG 12 R(S) 1.0 0.6 BVG 11 Z 1.6 --- Body material and surface treatment = Steel (lever housing gas nitrated) Actuation torque = approx. 70 Nm at 320 bar 1) With solenoid actuation: 20 lpm up to 200 bar 12 lpm up to 320 bar and 80% ED see also sect. 3.1 Flow Undrilled for customized diameter acc. to p-q-curve of the orifices, sect. 3.1 3) Only with type BVP 11(, not available for type BVG.. (housing dimensions to small - radiation insufficient) BVP 11 R(S) 0.9 --- BVP 11 Z 1.0 --- Complete with actuation BVG 2 R(S) BVG 2 Z BVP 2 R(S) BVP 2 Z 1.3 1.7 1.1 1.4 p-q-curve Basic valve Additional orifices Back pressure p (bar) Back pressure p (bar) Flow Q (lpm) Viscosity of the oil during tests approx. 60 mm 2 /s Flow Q (lpm)

D 7400 page 8 Unit dimensions All dimensions are in mm and subject to change without notice! Version for pipe connection Illustration with solenoid actuation (coding G.. or WG..); For manual actuations, see below Type BVG 11 R(S) Manual emergency actuation approx. 35 1 ) Cable gland Type BVG 12 R(S) approx. 35 Type BVG 11 Z Ø6.5 thru-hole Manual emergency actuation Coding A (applies to type BVG..11(12 and ) Ø6.5 thru-hole Manual emergency actuation (applies to type BVG..11(12 and ) Actuation aid (do not use any sharp-edged parts) Ports conf. ISO 228/1 (BSPP): A, B, and C = G 1/4 (BVG 11 R, S and Z) = G 3/8 (BVG 12 R and S) Type BVG 2 R(S) Cable gland approx. 35 1) Manual emergency actuation #5 The valve may be actuated by pressing down the brass bolt visible from above by means of a steel pin or a screw driver etc. Note: All pressure apparent at port B loads on the cross section of the brass bolt Ø5 i.e. 100 bar or 195 N! Type BVG 2 Z approx. 35 Ø6.5 thru-hole Ports conf. ISO 228/1 (BSPP): A, B, and C = G 3/8 1) Note: This dimension is depending on the manufacturer and can be up to max. 40 mm acc. to DIN EN 175 301-803! When required the solenoid may be rotated to the valve body by another 4x90 in addition to the standard assembly position illustrated here.

D 7400 page 9 Version for manifold mounting Illustration with solenoid actuation (coding G.. or WG..), For manual actuations, see type BVG.. Type BVP 11 R(S) Type BVP 11 Z For missing data see type BVG..! M6, 6 deep Sealing of ports A, B, and C via O-rings 7.65x1.78 NBR 90 Sh. Available as spare part, seal-kit DS 7400-1. M5, 6 deep Type BVP 2 R(S) For missing data see type BVG..! M 5, 6.5 deep Sealing of ports A, B, and C via O-rings 7.65x1.78 NBR 90 Sh. Available as spare part, seal-kit DS 7400-1. Type BVP 2 Z For missing data see type BVG..! M 5, 6.5 deep Sealing of ports A, B, and C via O-rings 7.65x1.78 NBR 90 Sh. Available as spare part, seal-kit DS 7400-1.

D 7400 page 10 5.2 2/2-way directional valve with by-pass check valve There is a modified version of valve type BVG-2R available, which may be equipped with a check valve to by-pass the blocked passage B A. p-q-curve Order example: BVG R 2 R -... Symbol Coding like in sect. 5.1 R = By-pass check valve Note: Dimensional drawing and mass (weight) like type BVG 2 R acc. to sect. 5.1 Back pressure p (bar) Opening pressure of the check valve approx. 0.8 bar Position a Position 0 Flow Q (lpm) 5.3 Schematic cross sectional views (standard versions acc. to sect. The schematic cross sectional views are represented here to show the functional principle, illustrated are valves in actuated state. They do apply to all actuations acc. to table 4. Type BVG 3 R.. Type BVG 3 S.. Type BVG 3 Z..