High-Voltage DIN Rail Screw Terminal Block for Rack Mount Users. Using the Terminal Block Safely with High Voltage Signals

Similar documents
INSTALLATION INSTRUCTIONS 160-Pin Cable for the NI PXI-2530B

CompactRIO crio-9052

FIELDPOINT BUS EXTENDER CABLE

NI 653x Cable Adapter

NI NI C Series Overview DATASHEET. 8-Channel Sinking Digital Input Module

How To Write A Librao Low Voltage Differential (Lvds) Module On An Nio 6585 Fuserio (Flexrio) Power Supply (Femaleseo) And Power Supply On An Iphone Or Ip

Square D Clipsal DIN-Rail Four-Channel Auxiliary Input Unit

MCR1900 Media Converter 19-Slot Chassis

Set Up Your MXI -Express x1 System

LIEBERT VNSA Installation Sheet

Set Up Your MXI -Express x4 System

HP UPS R1500 Generation 3

NI Channel, 60 V, High-Speed, Sourcing Digital Output Module

Installation. Smart-UPS VT MGE Galaxy Maintenance Bypass Panel kva 400 V

NI USB-5681 RF Power Meter Specifications

NI USB-6008/6009 OEM USER GUIDE

HP 16/18-Port Cable Management Kit Installation Guide

About the BitStorm 6051 POTS Splitter

DLP-PU/E Instruction Manual

Radiant Temperature Sensor TY7321

TECHNICAL DATASHEET #TD1404AX PWM CONTROLLED SOLENOID DRIVER

NI PXI Installing Your PXI Board INSTALLATION GUIDE

NI 9211 Datasheet DATASHEET. 4 TC, ±80 mv, 24 Bit, 14 S/s Aggregate

MultiVOIP FX FXS-Only SIP Gateways

Digital input modules

MultiVOIP FX SIP Gateways

HARAX circular connector

Zlinx Wireless I/O. Peer-to-Peer and Modbus I/O B&B ELECTRONICS PRODUCT INFORMATION

Amphenol C 091 A/B/D. Circular Connectors. Amphenol-Tuchel Electronics GmbH

Model: DC-A2IO Advanced HVAC Controller

INSTALLATION INSTRUCTIONS

AI120 AIswitch Series 120 Chassis

I NTERFACE CABLE ADAPTER MODULE

SCXI CHANNEL ISOTHERMAL TERMINAL BLOCK

Model 201 Wiegand Touchpad Reader Installation Guide

08. SEK IDC CONNECTORS

MILLENIUM INSTALLATION MANUAL NTR 735 A. Simple Automation Control Module (MAS)

Connecting the Channel A

LevelOne IFE Port PoE + 1-Port TP Industrial Fast Ethernet Switch User Manual

SEZ220. Signal Converter. Synco 200. With preprogrammed standard applications Freely programmable Menu-driven operation. Use

Chrome DIN Rail Power Supply 24V 30W 1 Phase (Class II & NEC Class 2) / DRC-24V30W1AZ

I nstallation. M100Q Series Proportional Actuator with R81Q Controller Board for Thermistor Sensor Applications. Tools Needed.

Contents. SPECIFICATIONS AND FEATURES GUIDE NI Serial Hardware

Directory chapter 02 - DIN Power (to 6 A) Types D, E, F, FM, 2F, F9, interface connectors I/U Technical characteristics types D and E

Chrome DIN Rail Power Supply 12V 54W 1 Phase (Class II & NEC Class 2) / DRC-12V60W1AG

Solid Core and Split Core Adjustable Current Status Switches CSS-O, CSS-C; CSP-O, CSP-C

USB-6008/6009. Contents USER GUIDE. This user guide describes how to use the National Instruments USB-6008/6009 data acquisition (DAQ) devices.

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

HP 36-Port InfiniBand Switch Cable Management Kit Installation Guide

HMI display Installation Guide

Product and Applications Description. Application Programs. Example of Operation. GAMMA instabus Technical Product-Information.

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC A - M8 connector

5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual

IP DSLAM IDL Quick Installation Guide

Directory chapter 04

Square D Clipsal C-Bus Network Analyzer

Electronic Control Devices The European Product Catalogue 2007

Square D Clipsal Two-Channel DIN-Rail DALI Gateway

Intersection Preassembled 19-inch Rack

FOSTCDR. Industrial Serial to Multimode Fiber Optic Converter PRODUCT INFORMATION B&B ELECTRONICS. Specifications Serial Technology

Telephone- and leased line modem for industrial applications TD-36

HP Port Switches Quick Setup Guide

Electronic overload relay EF19 and EF45

KZ0224UW INSTALLATION MANUAL SURGE PROTECTED CCTV POWER SUPPLY 24V AC, 5 AMP KZMI /12/01

WD-AMX Water Detection Controllers

PowerFlex 700S and 700H Frame 12 DC Bus Connector Kit

CompactLogix Power Supplies Specifications

AC and DC Drive System Installation Information

Installing the Tracer ZN517 Unitary Controller Ordering number: ,

HSP GmbH Zum Handwerkerhof Wendelstein Tel / Fax: / Web: HSP@hsshsp.de NTG-3000.

PS4-24 OWNERS MANUAL 24 VAC 90 WATT WALL MOUNTED CCTV POWER SUPPLY

This document lists specifications for the NI PXIe-4139 (NI 4139) precision system sourcemeasure

Redundancy Module QUINT-DIODE/40

Unpack and Install the Devices, Accessories, and Cables

DVI DA2 and DVI DA 4 User Guide

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

OPLC Installation Guide

Chrome DIN Rail Power Supply 24V 91.2W 1 Phase (Class II & NEC Class 2) / DRC-24V100W1AZ

E2600 DSA E-Series iscsi Disk Arrays. en Quick Install Guide

IMMS-CCC. IMMS-CCC Hardwire Central Interface. Installation Instructions

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS

The power module is Feature Number 8800-F2-901.

How To Power A Schen

Enphase Engage Cable and Accessories

Hardware Installation and Configuration Guide

DAQ. NI SCB-68A User Manual. 68-Pin Shielded Connector Block. ni.com/manuals. NI SCB-68A User Manual. August A-01

Wiser Panel Meter, Model Number WISERCTPM200 Installer s Guide

Power Supplies 3. SDN-P DIN Rail Series

Material: Weight: Bearing Life: Shaft Speed: Starting Torque: Mass Moment of Inertia: Shaft Loads:

T7560A,B,C Digital Wall Module

EVC40 EMERGENCY VOICE COMMUNICATION SYSTEM

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

12-Volt 10-Amp Regulated Power Supply

Adjustment functions for both span and shift have been incorporated

TX OPEN RS232/485 module

2013 Wireless Video Intercom INSTALLATION GUIDE

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N

MACTek Corporation. USB HART Interface. Users Manual

PCI/PXI ETHERNET ADAPTERS

Model 1756 Test Lead Kit

Transcription:

INSTALLATION GUIDE NI CB-37F-HVD High-Voltage DIN Rail Screw Terminal Block for Rack Mount Users This guide describes how to install and use the National Instruments CB-37F-HVD 37-pin D-SUB high-voltage (150 V) DIN rail terminal block. The CB-37F-HVD has screw terminals for connecting up to 37 I/O signals. Use 12 30 AWG wire to connect to the CB-37F-HVD screw terminals. Using the Terminal Block Safely with High Voltage Signals The CB-37F-HVD is UL recognized. You can use the CB-37F-HVD terminal block with low-voltage or high-voltage products up to 150 V. When hazardous voltages (>30 Vrms, 42.4 V pk, 60 VDC) are present on any terminal, all terminals must be considered hazardous. Ensure that external wiring or any circuits connected to the device are properly insulated from human contact. Caution Failure to adhere to the following precautionary steps when connecting the cable to a high-voltage NI device can result in electrical shock or death. Caution Before you begin installation, ensure that no high-voltage signals are connected to your accessory. Caution Signal connections should be made by a qualified technician or service personnel. Caution When using this product with UL listed high-voltage PCI or PXI devices, the connecting cable must be keyed for hazardous voltage (>30 Vrms, 42.4 V pk, 60 VDC) using the 37-Pin High-Voltage Accessory Kit. This kit is provided with the PCI/PXI device or can be ordered separately for replacement (part number 779445-01). Refer to the 37-Pin High-Voltage Accessory Safety Kit Installation Guide provided in the kit for installation instructions.

When using the CB-37F-HVD with hazardous voltages (>30 Vrms, 42.4 V pk, 60 VDC), it is required that all signal wires must be strain relieved, and the CB-37F-HVD must be placed in a UL listed, suitably-rated NEMA or IP enclosure, shown in Figure 1, which is grounded to a safety earth ground. The enclosure must be entirely enclosed and none of the parts should be accessible to the user when the system is running. What You Need to Get Started Figure 1. CB-37F-HVD and UL Listed Enclosure The following items are necessary for setting up and using the CB-37F-HVD terminal block: Hardware CB-37F-HVD terminal block DAQ device SH37F-37M-x 37-pin female-to-male shielded I/O cable or other 37-pin cable rated to 150 V Cabling and sensors as required for your application 37-Pin High-Voltage Accessory Safety Kit (supplied with high-voltage devices) DIN Rail (and DIN rail mounting kit) Zip ties UL listed industrial enclosure 1, electrical cabinet, or rack-mount cabinet 1 National Instruments sells two UL listed industrial enclosures: FP-ENC1 industrial enclosure with polycarbonate window (part number 777596-01) and NI FP-ENC1 industrial enclosure with solid metal door (part number 777596-02). NI CB-37F-HVD Installation Guide 2 ni.com

Connecting the Signals Documentation (available at ni.com/manuals) Read Me First: Safety and Radio-Frequency Interference DAQ Getting Started Guide Documentation for your DAQ device 37-Pin High-Voltage Accessory Safety Kit Installation Guide (supplied with the 37-Pin High-Voltage Accessory Safety Kit) Tools 1/8 in. flathead screwdriver Wire insulation stripper To connect signals to the CB-37F-HVD terminal block, refer to Figure 2 while completing the following steps. Note Refer to the Read Me First: Safety and Radio-Frequency Interference document before removing equipment covers or connecting or disconnecting any signal wires. National Instruments Corporation 3 NI CB-37F-HVD Installation Guide

2 3 4 1 5 9 7 4 8 6 7 3 1 D-SUB Connector 2 Screw Terminals 3 Zip Ties 4 End Piece 5 Chassis Gnd ( ) 6 Signal Wires 7 Screw 8 DIN Rail Clip 9 PCB Figure 2. CB-37F-HVD Parts Locator Diagram 1. Ensure no voltage is present on the signal wires. 2. Mount the CB-37F-HVD onto the DIN rail. 3. Prepare the 12 30 AWG signal wire by stripping the insulation no more than 4.0 mm (0.16 in.). 4. Insert the stripped ends of the signal wires into the screw terminals. Make sure no bare wire extends from the terminal. 5. Tighten the screws to a torque of 0.3 N m (2.7 lb - in.). 6. Tighten the zip ties securely around the signal wires for strain relief. For additional strain relief, you should securely tighten additional zip ties around signal wires from the top row of screw terminals. Note To replace the zip ties, remove one of the end pieces from the CB-37F-HVD. Slide the PCB out and guide the zip tie through the holes on the PCB. Replace the PCB, end piece, and screws. NI CB-37F-HVD Installation Guide 4 ni.com

Cabling to the Terminal Block Specifications You must install the DAQ device in a PC or PXI chassis, as described in the DAQ Getting Started Guide, before cabling the device to the terminal block. Complete the following steps to connect the terminal block to the DAQ device D-SUB connector. 1. Connect the DAQ device to the terminal block with the 37-pin cable. 2. Tighten the two cable thumbscrews to a torque of 0.3 N m (2.7 lb - in.) on each end of the cable. All specifications are typical at 25 C unless otherwise specified. Electrical Coupling... DC 1 Terminal wire size... 12 to 30 AWG Field-wiring connectors Signal screw terminals... 37 Earth-ground screw terminal... 1 (, for shielding only, not a safety ground) Strain relief... Zip ties through holes in PCB Maximum current... 2 A per conductor Mechanical Dimensions... 13.75 cm 9.0 cm 6.5 cm (5.5 in. 3.55 in. 2.5 in.) Maximum Voltage Weight... 210 g (7.5 oz) Maximum voltage refers to the signal voltage plus the common-mode voltage. Channel-to-ground... 150 V 1 In instrumentation terminology, DC coupling means that both DC and AC signals are passed. National Instruments Corporation 5 NI CB-37F-HVD Installation Guide

Environmental Operating temperature...0 to 50 C Storage temperature... 20 to 70 C Humidity...10 to 90% RH, noncondensing Maximum altitude...2,000 meters Pollution Degree (indoor use only)...2 Safety The CB-37F-HVD terminal block is UL recognized and meets the requirements of the following standards for industrial control: EN 50178 UL 508 CAN/CSA-C22.2 No. 14 Note For the UL certification, refer to the product label or visit ni.com/certification, search by model number or product line, and click the appropriate link in the Certification column. NI CB-37F-HVD Installation Guide 6 ni.com

National Instruments, NI, ni.com, and LabVIEW are trademarks of National Instruments Corporation. Refer to the Terms of Use section on ni.com/legal for more information about National Instruments trademarks. Other product and company names mentioned herein are trademarks or trade names of their respective companies. For patents covering National Instruments products, refer to the appropriate location: Help»Patents in your software, the patents.txt file on your CD, or ni.com/patents. 2005 National Instruments Corporation. All rights reserved. 371716A-01 Oct05