SM 1234 ANALOG INPUT/OUTPUT MODULE

Similar documents
6ES7313-5BF03-0AB0. Supply voltages Rated value 24 V DC Yes permissible range, upper limit (DC) circuit breaker type B, min. 4 A

6ES7314-6CG03-0AB0. Supply voltages Rated value 24 V DC Yes permissible range, upper limit (DC) circuit breaker type B, min. 4 A

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs

Panel Meters and Controllers Modular Panel Meter Type EDM 35

LOGO! Logic module. Brochures For brochures serving as selection guides for SIMATIC products refer to: printmaterial

6ES BE01-0AB0 6ES BE01-0AB0

The CP FO provides access to different communication services of the PROFIBUS bus system:

Technical data. General specifications. Signal voltage V DC Signal duration. 1 s Input 2. Signal voltage. 1 s Analog output.

CP Page 1342 Mar 2008 Siemens ITS

The CP provides access to different communication services of the PROFIBUS bus system:

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

Safety technique. Emergency stop module BO 5988 safemaster

How To Use A Sound Card With A Subsonic Sound Card

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q R0001

SIMATIC. S7-300 and M7-300 Programmable Controllers Module Specifications. Preface, Contents. General Technical Specifications. Power Supply Modules

Electronic timer CT-VBS OFF-delayed without auxiliary voltage, for DC contactors Data sheet

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start * see variants. Applications.

HSP GmbH Zum Handwerkerhof Wendelstein Tel / Fax: / Web: HSP@hsshsp.de NTG-3000.

Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate

Specifications for EM VDC 4 In/4 Out and EM VDC 4 In/4 Relay Out

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

SIMATIC. ET 200S distributed I/O 2AO I ST analog electronic module (6ES7135-4GB01-0AB0) Preface. Properties 1. Parameters 2.

MLC TM Maximum Productivity and Versatility for Control without Compromise!

Power-monitoring unit PowerLogic System. Technical data sheet. Power Meter Series 800

Permissible ambient temperature Operation Storage, transport

SIMATIC. SM 335 High-Speed Analog Input/Output Module for the SIMATIC S7-300

Analog signal converters CC-E I/I Current / current isolators

Fieldbus slave modules with I/Os, DIO

Digital input modules

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

Adding Pneumatic Preset Counter. Type 497. Continuously visible preset Integrated pneumatic reset 3 or 5-digit display Convenient button setting


RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

Current and voltage measuring relays

SIMATIC NET. CP AS-Interface Master B C. Preface Contents. Technical Description and Installation Instructions Interface to the User Program

TPM Product Type 107-D162-NNT 48-channel digital input and 16-channel digital output module with pluggable terminal

Displayport Extender via 2 multimode fibers LC Duplex Connector Extends Displayport Link up to 200 meters

ABB i-bus KNX Switch Actuator, x-fold, 16/20 A, MDRC SA/S x , 2CDG 110 1xx R0011

3 3RG78 45 program overview

Quick Connect. quick - simple - efficient.

MICROSENS. Central 48 V DC Power Supplies for PoE-Components. Description. Features

Pluggable interface relays CR-P Pcb relays

Contents. Document information

SIMATIC S7-300, CPU 315-2DP CPU WITH MPI INTERFACE INTEGRATED 24 V DC POWER SUPPLY 128 KBYTE WORKING MEMORY 2

DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

MILLENIUM INSTALLATION MANUAL NTR 735 A. Simple Automation Control Module (MAS)

ABB i-bus EIB / KNX Analogue Input AE/S 4.2

Preset Counter signo 721

Fiber Optic Selector Guide for Analog & Digital Data Links, Contact Closures & Multiplexers

Differential Charge Amplifier

IBS IP KIS A. Data Sheet INTERBUS-S. Digital I/O Module

Siemens AG 2011 SINAMICS V60. The perfect solution for basic servo applications. Brochure May 2011 SINAMICS. Answers for industry.

L-LAS-TB-CL serie. laser light curtains for inline measuring tasks

Siemens AG /42 Analog modules 3/42 EM 231 3/42 EM 232 3/42 EM 235 3/47 EM 231 thermocouple module 3/49 EM 231 RTD module

Technical Data Sheet OPUS A3 STANDARD Full TDS OPUS A3sF,

Modular I/O System Analog and Digital Interface Modules

Voltage Regulator SPAU 341 C. Product Guide

VEO. V4PF480Y/277VSYTK02 Art.Nr.: V4PF480Y/277VSYTK02P Art.Nr.: TECHNICAL DATA

CPUs - CPU PN/DP

HCR3.2/.. Chipcard reader HOTEL SOLUTION

Series AMEPR30-AZ up to 2.5A AC-DC / DC-DC LED Driver / Converter

Rack mounted telephone- and leased line modem for industrial applications

ABB i-bus KNX SA/S Switch Actuators Product Manual

HARDWARE MANUAL. Ixx24-A 1/20. Val Controls A/S Limfjordsvej 3 DK-6715 Esbjerg N Tel vc@valcontrols.com

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

Thyristor-controlled power supplies and battery chargers

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application.

PCS0100en Persy Control Services B.V. Netherlands

Product and functional description

Características. Starligh SA 9 de julio 1595 Córdoba Argentina /

Digital Pressure Measuring Instrument MDR480

ABB i-bus KNX Switch Actuator, x-fold, 16 A, MDRC SA/S x , 2CDG1101xxR0011

E-STOP relays, safety gate monitors

FLOW CALCULATOR INSTRUCTION MANUAL MESURES BAMOPHOX M1 02 E MES FLOW CALCULATOR /1

BROADCAST Trasmettitori / Transmitters DBH3 GAP FILLER

DSD 70 Dual Channel Hall Effect Speed Sensor for Railway Applications, compliant with EN 50155

STEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC A - M8 connector

Multifunction devices

RM35UA13MW. range V. Main. Product or component type. Relay monitored parameters

APSYN420A/B Specification GHz Low Phase Noise Synthesizer

Vert-X 16-5V / % Ub. Applications Servodrives Dancer arm Operating table

J TB/TW Temperature limiter, temperature monitor

Telephone- and leased line modem for industrial applications TD-36

Isolated AC Sine Wave Input 3B42 / 3B43 / 3B44 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Operating Manual UMB Analogue/Digital Converter ANACON Order Number: 8160.UANA

Product Information. Gateway For Connecting EnDat Encoders to PROFIBUS-DP

VOLTAGE/CURRENT CALIBRATOR ISO-TECH ILC-421

Auto-tune PID. Temperature Controller BRAINCHILD FEATURES

Technical Data. General specifications Switching element function Rated operating distance s n 15 mm

Refrigeration Compressed Air Dryer Buran Ultrapulse

Substation Automation Products Relion 670/650 series IEC and ANSI Hardware

MultiViu Flex 7 Data Sheet

MCR-VDC-UI-B-DC. Voltage Transducer for DC Voltages. INTERFACE Data Sheet _en_01. 1 Description

is then retained absolutely without interruption.

4 non-safe digital I/O channels 2 IO-Link Master V1.1 slots. Figure 1. Figure 2. Type code. TBPN-L1-FDIO1-2IOL Ident no

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT Spur 2. Spur 1. Zone 1. Zone 0

Contact expander modules

Transcription:

SM 1234 ANALOG INPUT/OUTPUT MODULE Function The SM 1234 analog input/output signal modules convert analog signals from the process into digital signals for internal processing by the SIMATIC S7-1200. convert digital signals of the SIMATIC S7-1200 into signals for controlling the respective process. Technical specifications Page 904 Mar 2008 Siemens ITS

Technical specifications 6ES7 234-4HE30-0XB0 SM 1234 A I4x13 bit AQ 2x14 bit Supply voltage 24 V DC Input current Current consumption, typ. 60 ma from backplane bus 5 V DC, typ. 80 ma Power losses Power loss, typ. 2 W Analog inputs Number of analog inputs 4; Current or voltage differential inputs permissible input frequency for current input ± 35 V permissible input voltage for voltage input 35 V permissible input current for voltage input 40 ma Cycle time (all channels) max. 625 µs Page 905 Mar 2008 Siemens ITS

permissible input current for current input 40 ma Input ranges Voltage ; ±10 V, ±5 V, ±2.5 V Current ; 0 to 20 ma Thermocouple Resistance thermometer Resistance Input ranges (rated values), voltages -10 V to +10 V Input resistance (-10 V to +10 V) 9 MOhm -2.5 V to +2.5 V Input resistance (-2.5 V to +2.5 V) 9 MOhm -5 V to +5 V Input resistance (-5 V to +5 V) 9 MOhm Input ranges (rated values), currents 0 to 20 ma Input resistance (0 to 20 ma) 250 ohms Temperature compensation Parameterizable Analog outputs Number of analog outputs 2; Current or voltage Output ranges, voltage -10 to +10 V Page 906 Mar 2008 Siemens ITS

Output ranges, current 0 to 20 ma Load impedance (in rated range of output) with voltage outputs, min. 1 000 Ω with current outputs, max. 600 Ω Analog value creation Measurement principle Differential Integrations and conversion time/ resolution per channel Resolution (incl. overrange) Voltage: 14 bits; Current : 13 bits Resolution with overrange (bit including 12 bit; + sign sign), max. Integration time, parameterizable Interference voltage suppression for interference frequency f1 in Hz Smoothing of measured values Parameterizable Step: ne Step: low Step: Medium Step: High Errors/accuracies Temperature error (relative to input area) 40 db, DC to 60 V for interference frequency 50 / 60 Hz Page 907 Mar 2008 Siemens ITS 25 C ±0.1 % to 55 C ±0.2 % total measurement range

Temperature error (relative to output area) 25 C ±0.3% to 55 C ±0.6% total measurement range Basic error limit (operational limit at 25 C) Voltage, relative to input area +/- 0,1 % Current, relative to input area +/- 0,1 % Voltage, relative to output area +/- 0,3 % Current, relative to output area +/- 0,3 % Interference voltage suppression for f = n x (fl +/- 1%), fl = interference frequency common mode voltage, max. 12 V Interrupts/diagnostics/status information Alarms Alarms Diagnostic alarm Diagnoses Diagnostic functions Monitoring the supply voltage to the electronics Wire break Short circuit Diagnostics indication LED for status of the inputs For status of the outputs for maintenance Page 908 Mar 2008 Siemens ITS

Galvanic isolation Galvanic isolation analog outputs between the channels and the power supply of the electronics Climatic and mechanical conditions for storage and transport Climatic conditions for storage and transport Free fall Drop height, max. (in packaging) Temperature Permissible temperature range Air pressure acc. to IEC 60068-2-13 Permissible air pressure Mechanical and climatic conditions during operation Climatic conditions in operation Temperature Permissible temperature range Air pressure acc. to IEC 60068-2-13 Page 909 Mar 2008 Siemens ITS 0.3 m; five times, in dispatch package -40 C to +70 C 1080 to 660 hpa 0 C to 55 C horizontal installation 0 C to 45 C vertical installation

Permissible air pressure Pollutant concentrations SO2 at RH < 60% without condensation Degree and class of protection IP20 Standards, approvals, certificates CE mark C-TICK FM approval Connection method required front connector Mechanics/material Type of housing (front) Plastic Dimensions Width Height Depth Weight Weight, approx. 1080 to 795 hpa S02: < 0.5 ppm; H2S: < 0.1 ppm; RH < 60% condensation-free Page 910 Mar 2008 Siemens ITS 45 mm 100 mm 75 mm 220 g