The PCI Series. Precise power control for complex SCR applications. Phase-Fired SCR Power Controllers AMPS VAC. ROBICON 1996 Rev.

Similar documents
Bulletin 150 Smart Motor Controllers SMC-3 Smart Motor Controller

CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE. General purpose single phase thyristors and solid state relays Product data.

Bussmann. All-In-One Module. Bussmann Power Module Switch. How to configure Part Numbers: Step 1: Select Switch Amperage 1

Series /16 DIN Multi-Mode Bar Graph Display Timer TIMERS PRODUCT HIGHLIGHTS

Single Phase Soft Starter

RC NETWORKS SALES GUIDE

Buck - Boost Transformers

AMFA-27 AMFA-29. Operator s Manual & Installation Instructions. Rev. 2.5

LTR Series Uninterruptible Power Systems 700 VA KVA. General Specification

THYRISTORS T1-1PH from 850A to 2700A Specifications Universal 1 Phase Thyristor Unit , March 2012

Power Supplies 3. SDN-P DIN Rail Series

Figure 1 - Crydom 3RHP Three-phase Hybrid Solid State Contactor. Crydom Inc.

DCS Series 1 kw, 1.2 kw, & 3 kw

Bulletin 150 SMC Flex Smart Motor Controller Specifications

Thyristor-controlled power supplies and battery chargers

SmartOnline V 5kVA 4.5kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 4U Rack/Tower, USB, DB9 Serial

Specifying a Variable Frequency Drive s

GS Semiconductor Fuselinks. GE Power Controls. GS Semiconductor fuselinks

Industrial-Grade UPS System Heavy-duty power protection for harsh industrial environments

Product Guide AC Voltage Control Devices. Guide Guide. Popular Variable Transformers and AC Power Supplies.

BRITISH STYLE SEMICONDUCTOR PROTECTION FUSES

S112-XHS. Description. Features. Agency Approvals. Applications. Absolute Maximum Ratings. Schematic Diagram. Ordering Information

OmniVS Series 1500VA Line-Interactive Tower 120V UPS with USB port

3) What is the difference between "Insulating", "Isolating", and "Shielded Winding" transformers?

Series AMEPR30-AZ up to 2.5A AC-DC / DC-DC LED Driver / Converter

SECTION VARIABLE FREQUENCY DRIVES

Series OMEGA WATTS POWER SUPPLY AC/DC SINGLE OR MULTIPLE OUTPUT. Flexible modular design. Programmable outputs** Power factor correction***

SmartPro 120V 2.2kVA 1.92kW Line-Interactive Sine Wave UPS, SNMP, Webcard option, 2U Rack/Tower, LCD, USB, DB9 Serial

CAT ATC POWER BREAKER & POWER CASE SWITCH AUTOMATIC TRANSFER SWITCH

MT..KB SERIES 55 A 90 A 110 A THREE PHASE CONTROLLED BRIDGE. Power Modules. Features. Description. Major Ratings and Characteristics

Model #: SMART2200CRMXL

Specification Requirements DBL 700MX and 1000MX Series UPS

Sentron Series Circuit Breakers

SAFETY PRECAUTIONS AND INSTRUCTIONS FOR USE OF TECHNICAL INFORMATION

650W Single Output Power Supply 15V 24V. 27V 48V Rated Current. 0 ~ 100A 0 ~ 50A 0 ~ 40A 0 ~ 27A 0 ~ 24A 0 ~ 13.6A Rated Power

1000W Single Output Power Supply 15V 24V. Protection type: Total Power limit, Latch-style (Recovery after reset AC power ON or inhibit)

BT300 HVAC Drives Conventional Bypass (C-Bypass) Options

SmartOnline V 6kVA 4.2kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 6U Rack/Tower, DB9 Serial, Hardwire

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

3753 en /b VE/B - VE/RG Va V riable speed drives

PSR The compact range Description

Advanced Power Supply Topics

Research RF Sputtering Packages

For a complete explanation of all the functions and configurations available please refer to the SC6006: Manual of operation.

GTEC transfer switch open transition

SmartPro 120V 500VA 300W Line-Interactive UPS, SNMP, Webcard, 1U Rack/Tower, USB, DB9 Serial

WYE-DELTA AND SOLID STATE STARTER APPLICATION GUIDE

12S, 14S, 15S Series. Time Delay Relays and Sequencers. Time Delay Relays and Sequencers. Features and Benefits. Switch Actions and Configurations

High Power Programmable DC Power Supplies PVS Series

SmartPro 120V 750VA 600W Line-Interactive Sine Wave UPS, SNMP, Webcard, 1U Rack-Mount, USB, DB9 Serial

KBIC Solid State SCR DC Motor Speed Controls See table 2 page 4 for KBIC models covered by this manual

SmartPro 120V 750VA 600W Line-Interactive Sine Wave UPS, 1U Rackmount, SNMPWEBCARD Option, USB, DB9 Serial

SmartPro 120V 1kVA 800W Line-Interactive Sine Wave UPS, SNMP, Webcard, 1U Rack, USB, DB9 Serial

Product Family of Capacitor Chargers PS-17XX for 1500J/Sec in the range 500Vac to 1,000Vac PS-22XX for 2200J/Sec in the range 500Vac to 1,000Vac

Antec TruePower User's Manual

CAT AVR V2.3. Instruction Manual. Voltage regulator for generators. March 2008

How To Protect A Motor From Overcurrent

1.44 kw Programmable DC Power Supplies XLN Series

How To Select A Solid State Relay For A Three Phase Resistive Load

... Electronic Softstarter...

DC/DC power modules basics

Phone: Fax: Web: info@clrwtr.com

FPAB20BH60B PFC SPM 3 Series for Single-Phase Boost PFC

7-41 POWER FACTOR CORRECTION

TAA-Compliant SmartPro 120V 1kVA.8kW Line-Interactive Sine Wave UPS, SNMP, Webcard, 1U Rack, USB, DB9 Serial

650W Single Output Power Supply

MTE SERIES RLW. World REACTORS USER MANUAL PART NO. INSTR 030 REL MTE Corporation

HPS Universal. Single and Three Phase Potted. Buck-Boost Transformers. Buck-Boost Applications & Standard Specification... 80

Whale 3. User Manual and Installation Guide. DC Servo drive. Contents. 1. Safety, policy and warranty Safety notes Policy Warranty.

TECHNICAL SPECIFICATIONS FOR 1.5 KVA ONLINE UPS

Sierra Dual 24 Volt Brushless DC Motor Controller Product Specification

THE MclNTOSH MC 2100 SOLID STATE STEREO POWER AMPLIFIER

Solid State Timers Type F

POWER AND VOLTAGE RATING

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

Dielectric Withstand and Ground Bond Testers For Production Line Safety Agency Compliance Testing

MODEL 1211 CURRENT PREAMPLEFIER

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:

Chrome DIN Rail Power Supply 12V 54W 1 Phase (Class II & NEC Class 2) / DRC-12V60W1AG

VARIABLE FREQUENCY DRIVES Revised 4/30/ Mechanical Systems

SMART SENSOR COLLECTION

Transformer circuit calculations

Safety technique. Emergency stop module BO 5988 safemaster

AP-1 Application Note on Remote Control of UltraVolt HVPS

POWER SUPPLY MODEL XP-15. Instruction Manual ELENCO

Type SA-1 Generator Differential Relay

TEA1024/ TEA1124. Zero Voltage Switch with Fixed Ramp. Description. Features. Block Diagram

Solid-State Relays. Series Included. Solid-State Relays SIR SLR NLF PHS Series PHS...148

Centro-Matic Automatic Lubrication Systems System Controls

MC Series Drives. Flexible, simple, rugged, robust! Phone: Fax: Web: info@actechdrives.

Product Description Full Voltage Starting Electric Fire Pump Controllers FTA1000

CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version)

Specification CyberWave UPS Ver /01/00

SmartOnline Expandable Rack / Tower UPS System Online, double-conversion protection for mission critical applications

PM734F - Technical Data Sheet Winding 28

HERZ-Thermal Actuators

PRODUCT GUIDE. SL Medium Voltage IEC Vacuum Contactors

However, industrial applications may utilize a relay, which short-circuits the ICL path after the inrush sequence.

TEP 200WIR Series, Watt

Transfer Equipment Controls

Transcription:

The PCI Series Phase-Fired SCR Power Controllers 25-1200 AMPS 120-600 VAC Precise power control for complex SCR applications. ROBICON 1996 Rev. 5/99 21

Applications The PCI (phase-angle, cosine intercept) power controller series provides full wave output with full wave, phase-angle fired control. Typically, phase-angle fired silicon controlled rectifiers (SCRs) regulate transformer coupled loads or loads with transient characteristics. But other control circuits can be sensitive to line fluctuations, and fail due to line voltage noise. To correct this problem, Robicon has added cosine intercept linear phase control to efficiently diminish the effect of noise on the unit. On one compact printed wiring board, the all-semiconductor gate trigger unit (GTU) combines the noise immunity of cosine intercept linear phase control with hard drive gate output circuits and a voltage regulator preamplifier. The GTU drives an inverse parallel-connected pair of SCRs for each phase controlled. The PCI Series can be operated into resistive or inductive loads driven directly or through an interposing transformer. Units are available with ratings of 25 to 1200 A and at 120 to 600 VAC. Application-Specific Features DC output Water cooled (Harsh environment) Fuseless operation (Induction heating) Systems (Custom design) Contact your sales representative for assistance. Output Output Voltage Regulation Controllable from 0 V to over 100% of VAC, RMS value of output is a linear function of the input control signal over the range from 5% to 100% VAC. Within this linear operating range, long term resolution is infinite, and output voltage regulation is ± 0.5% for a ± 10% line variation. Output Current Rating RMS line current ratings are based on continuous operation in free air at ambient temperatures of 122 F (50 C) or less. Voltage Surge Protection MOV-Capacitor-Resistor networks connected in parallel with each thyristor provide combined voltage surge and dv/dt protection. Thyristor ratings are selected to provide a minimum safety factor of 2.5X the nominal RMS of the AC supply voltage and typical suppressed dv/dt values. Type of Load Resistive or inductive loads may be either driven directly, or through an interposing transformer. Three-phase units are designed to drive balanced, three-wire, wye- or delta-connected transformer coupled loads; unbalanced straight resistive loads; or three-phase, 4-wire loads. Special precautions are required to limit peak inrush currents when driving capacitive loads. Consult the factory for application assistance. 22

Reliability and Performance Physical Construction Open panel construction is standard. Units can also be supplied in free standing or wall mounting custom enclosures. Undervoltage and Phase Loss Protection The GTU automatically deactivates when VAC falls below approximately 70% of nominal. Normal operation resumes when the line recovers to 80% of AC supply. Insulation RMS test voltages; control input circuit @ 500 VAC, power circuit @ 2500 VAC for 208 V through 600 V rated units. Ambient Temperature Ranges Operating, 0 F (-20 C) to 122 F (50 C). Consult factory for deratings above 122 F (50 C) or above 6000 ft. elevations. 1 PCI 25-60 amps 1 PCI 90-120 amps 1 PCI 180-225 amps 1 PCI 350-500 amps 1 PCI 650 amps 1 PCI 800-1200 amps Features AC Supply All units rated for nominal value VAC ± 10%. Standard voltage ratings: 120, 208, 240, 277, 380, 415, 480 and 600 V. Response Time Equivalent time constant (63% response) is approximately 50 milliseconds, independent of control input impedance. The maximum rate of output increase can be limited by a soft start circuit. Fuse Protection The PCI series controllers are available in both fused and fuseless designs. The fused units have I 2 t coordinated current limiting type fuses. When controlling a transformer primary, the fuseless units utilize electronic overload protection. Consult the factory for the correct SCR current rating for fuseless applications. Control Inputs Standard input signals from temperature controllers or PLCs control the PCI series. A listing is provided with the selection guide. 23

Gain and Bias Controls The gain and bias controls are conveniently accessed through the front panel for calibration. Current Limiting The linear current limit acts to prevent output current from exceeding a preset setpoint even though load resistance may be less than that defined by the ratio of maximum output voltage to rated output current. Cold load inrush currents may be 10X to 20X rated current until high temperature elements come up to heat. Setpoint range is 0 to 150% of rated current. (Note: For three phase units, the GTU auctions the feedback current signals to the maximum of the three line currents. The other two line currents will be less than or equal to the current in the controlled line.) Overcurrent Trip with Automatic or Remote Manual Reset A high speed electronic overload trip or chop-off limiter protects the semiconductors against any load shorts. The overcurrent trip monitors the output by means of current transformer feedback. Within a half-cycle that the load fault occurs, the controller automatically shuts off the SCRs. In the instantaneous trip mode, the on-board relay changes state, but will reset after approximately 100 milliseconds. In reclosing operations, three attempts will be made, after which the on-board relay latches. Reset is accomplished by interrupting power or by a remote reset. (See Current Imbalance Detector Option.) Soft Start Ramp Characteristic The increasing rate of the output voltage RMS value is limited to prevent high inrush currents with transformer-coupled loads or with elements having high cold-to-hot resistance ratios. With nominal gain setting, rate of increase is limited to approximately 100% per second. Additional protective circuits prevent excessive output bursts due to the fluctuations of reapplied AC supply voltage. Standard ramp time is one second. Optional ramp times are available. Features Conservative thermal design increases service life and minimizes maintenance Compact design Electrically isolated heat sinks, 25-225 amp units Infinite firing-angle resolution for precise control SCRs rated 1400 PIV I 2 t fuses, MOVs and dv/dt networks protect SCRs Voltage regulated (current/power available) Power linear Two-year warranty CSA Certification and UL Listing pending Up-front mechanical design permitting ease of accessibility to all major components Programmable logic in GTU eliminates phase sequence sensitivity on three phase units Voltage regulation of 0.5% for ±10% nominal line variation Current limit and overcurrent trip are standard features Soft start 3 PCI 25-225 amps 3 PCI 350-500 amps 3 PCI 650 amps 3 PCI 800-1200 amps 24

Options SCR Failure Detector Option This device senses a shorted SCR and provides a set of form-c relay contacts that the customer may use to alarm and/or turn off the process. The detector is a panel-mount unit that can be supplied for single and three phase applications. Power Regulation Option Power regulation compares the feedback and control signals so the output power will be linear to the control signal and will be regulated to maintain a selected constant power level at the controller output despite line and load changes. Current Imbalance Detector Option The current imbalance detector continuously compares the load currents of each phase. When an imbalance exceeds a predetermined value of 5 to 50%, a set of form-c contacts may be used to alarm and/or turn off the process. The current limit operated independently. (See Current Limiting.) When selecting the CID option the overcurrent trip option is not included. Current Regulation (Three Phase) Regulates SCR current output as a function of control signal input. Enclosures The SCRs can be supplied in NEMA enclosures (vented or fan cooled). SCR Failure Detector (This option is remotely mounted.) Contact factory or representative for ordering information. Formulas Calculation for three phase current when the line voltage and kw are known: I (current) = Power kw / (Voltage (E) X 3) example: 60 amps = 50 kw / (480 volts X 1.732) Calculation for single phase current when the line voltage and kw are known: I (current) = Power kw / Voltage (E) example: 104 amps = 50 kw / 480 volts Calculation for the heat generated by an SCR controller: (1.5 volts) X (the full load current) X (the number of controlled legs) = total watts example: 1.5 volts X 60 amps X 3 = 270 watts Typical Input/Output Connections for the 1 PCI Typical Input/Output Connections for the 3 PCI 25

Technical Specifications INPUT LINE VOLTAGE:* 120, 208, 240, 380, 415, 480 or 600 VAC, ±10%; 50/60 Hz (±1 Hz). CURRENT RATING:* 25, 40, 60, 90, 120, 180, 225, 350, 500, 650, 800, 1000, 1200 amperes. CONTROL METHODS:** 1) temperature or process controller 2) potentiometer; 5000 ohms, 1 / 2 watt (customer supplied) 3) dry contact closure (customer supplied) CONTROL SIGNAL ISOLATION: From SCRs 2500 VAC. From AC power input lines 2500 VAC. From chassis 500 VAC. VOLTAGE REGULATION: 0.5% per ±10% line voltage change. LINEARITY: ± 2% FS. POWER SCR PROTECTION: 1) Subcycle I 2 t semiconductor fuse. 2) Transient voltage spikes (dv/dt) across each SCR pair; all SCRs have 1400 PIV rating. CONTROLS: BIAS and GAIN potentiometers AMBIENT TEMPERATURE RANGE: Operation max. 122 F (50 C). Storage 14 F to 158 F (-10 C to 70 C). * Specify with order. ** Specify output when using a temperature/process controller. 1 PCI Series Amp Range Dimensions Weight Fan Cooling Power (as applicable) Height Width Depth* Lbs. Kg. 50 Hz 60 Hz 25 60 11.00 8.125 7.625 16.5 7.5 NA NA 90 120 9.00 9 9.062 16.5 7.5 NA NA 180 225 16.69 9.44 9.31 20 9.1 0.21 amps, 25 VA 0.19 amps, 23 VA 350 500 21.00 14.25 7.88 24 10.6 0.21 amps, 25 VA 0.19 amps, 23 VA 650 24.00 16.75 12.00 47 21.4 1.40 amps, 168 VA 1.20 amps, 144 VA 800 1200 33.00 16.75 14.50 71 32.3 1.40 amps, 168 VA 1.20 amps, 144 VA *Lug kits will increase the depth of the 350-1200A units. 3 PCI Series Amp Range Dimensions Weight Fan Cooling Power (as applicable) Height Width Depth* Lbs. Kg. 50 Hz 60 Hz 25 60 14.75 19 9.25 40 18.2 NA NA 90 225 14.75 19 9.25 40 18.2 0.42 amps, 50 VA 0.38 amps, 46 VA 350 500 30.75 19 8.50 60 27.3 0.63 amps, 76 VA 0.57 amps, 69 VA 650 36.00 24 12.00 126 57.3 4.20 amps, 504 VA 3.60 amps, 432 VA 800 1200 42.00 27 14.50 231 105.0 4.20 amps, 504 VA 3.60 amps, 432 VA *Lug kits will increase the depth of the 350-1200A units. 26

PCI Series Model Number Configuration PCI - - - CL/OC-D - - - - Phase Voltage Amperage Input Options Ramp Lug Kit P C I S E R I E S Phase Amperage Input Options 1 Single 25 Amps -1 0-5 ma -PR Power Regulation 40 Amps -2 0-20 ma (remote item in 3 phase) 3 Three 60 Amps -3 0-50 ma -CID * Current Imbalance 90 Amps -4 1-5 ma Detection 120 Amps -5 4-20 ma (remote item ) 180 Amps -6 12-20 ma -CR Current Regulation 225 Amps -7 0-5 volts DC 350 Amps -8 0-10 volts DC 500 Amps -9 Potentiometer * CID replaces OC-D 650 Amps 800 Amps 1000 Amps 1200 Amps Voltage RAMP Lug Kits 12 120 Volts -LK If lugs are required 20 208 Volts -FR.47 sec for 350 through 24 240 Volts -ER 4 sec 1200 amp units. 27 277 Volts 38 380 Volts (1phase) Lugs are standard 40 400 Volts (3 phase) for 60-225 amp units 41 415 Volts (1phase) 48 480 Volts 60 600 Volts All fan cooled units are equipped with "normally open" heat sink thermostats. "Normally closed" are available upon request. The table above will assist you in ordering the PCI Series. For example, for a single phase power controller that was 480 volts, 120 amps, 4-20ma, with a power regulation option, extended ramp, and no lug kit is necessary the model number is: 1PCI-48120-CL/OC-D-5-PR-ER ISE, Inc. 10100 Royalton Rd - Cleveland, OH 44133 USA Tel: (440) 237-3200 - Fax: (440) 237-1744 http://iseinc.com