IMMERSION FIRED STEAM BOILER

Similar documents
Commercial Gas Water Heaters

Originators of the Flexible Water Tube design

C. Burner management system to follow requirements of Industrial Risk Insurers (IRI).

Gas Unit Heaters Duct Furnaces Horizontal - 60 HZ Form No. LF (10/2011) LF24 Standard

High Efficiency Copper Finned Tube Boilers 750,000-2,000,000 BTU/HR

ASME Packaged Indirect Fired Water Heater

Commercial Semi-Instantaneous Water Heaters

Commercial Gas Furnace Upflow

SIOUX HYBRID WATER HEATER

High efficiency, cast-iron gas boiler

FLASH TANK ECONOMIZER PRODUCT GUIDE

Commercial Gas Water Heaters

Sulfur Tail Gas Thermal Oxidizer Systems By Peter Pickard

ELECTRODE BOILERS VAPOR POWER INTERNATIONAL

Residential/Commercial Gas Condensing High Efficiency Tankless Water Heaters

TANKLESS WATER HEATER INSTALLATION DIAGRAMS

G234X-55 Conventional Gas Boiler

Centauri. Condensing Fire Tube Water Boiler 399 to 1000 MBH

Series GM. Peerless Boilers. Residential/Commercial Gas Boilers

Replacement parts. WM97+ gas-fired water boiler Boiler Manual. OBTAIN PARTS ONLY THROUGH WEIL-McLAIN THE BOILER CONTAINS CERAMIC FIBER MATERIALS

Commercial Gas Water Heater

! WARNING. McDonnell & Miller Installation & Maintenance Instructions MM-217(I) Series 150S and 157S (Snap Switch, All Models except 157S-RB-P)

HOW TO SELECT A LOW VOLUME (L.V ) BOILER

BOILER FEED AND CONDENSATE RECOVERY SYSTEMS Extend the life and efficiency of your boiler system

Guidelines for Preparing for a Temporary Steam Plant

Factory owners must ensure the boiler is:

Hot Water Boilers and Controls Why Condensing Boilers are Different. Presented Oct. 14, 2008 Long Island Chapter, ASHRAE

Some Criteria for Choosing a Steam Boiler for a Microbrewery

with MERCURY FREE 1 HP Relays ! WARNING Before using this product read and understand instructions.

M/MR Modulating Valves TABLE OF CONTENTS DESCRIPTION SPECIFICATIONS. For Atmospheric, Infrared, and Direct Fired Burners

HEAVY DUTY STORAGE GAS

CHAPTER 10 BOILERS, WATER HEATERS AND PRESSURE VESSELS

RESIDENTIAL HEATING OIL SERVICE CONTRACT ANNUAL COST $276.00

Cooling Capacity CFM in. w.c. (125 Pa)

G26 Corp L11 Revised LENNOXOEMPARTS.COM. Service Literature G26 SERIES UNITS

UDSA - UDSBD unit heater

XV80 UPFLOW/HORIZONTAL 2-STAGE, VARIABLE SPEED GAS-FIRED FURNACE

NAVIEN AMERICA INC FITCH AVENUE

2010 Residential Water Heater Replacement Check List

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM

M7RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. High Efficiency / Direct Vent Condensing Downflow Gas Furnace

INSTALLATION & MAINTENANCE MANUAL TURBOPOWER GAS, OIL & GAS/OIL WATER HEATER

LAKE COUNTY ANIMAL SERVICES EXPANSION SECTION 15459

Light Duty Commercial Electric Water Heater

Commercial Gas Water Heaters

Boiler Preparation, Start-Up and Shutdown

Utility Distribution Systems

Your safety and the safety of others are very important.

Evaluating Thermal & Catalytic Oxidation Technology for VOC, HAP & Odor Abatement. John Strey

SENTRA SERIES WATER UNITS. 30 to 300 F Process Temperatures. 1/2 to 7.5 HP Centrifugal Pumps ( GPM) 10 to 34 KW Stainless Steel Heaters

Boiler & Pressure Vessel Inspection discrepancies and failures

Condensing Boiler Efficiency

One Year Warranty. Stock U.S. # of Volts Weight CONN. Height Dia. Watts # GAL. Elements INS. Inches NATURAL GAS* Six Year Warranty

TABLE 1. Rugged cast aluminum alloy casing,celcon waterways with nichrome parts White (unless stainless steel housing)

36G22, 36G23, 36G24 & 36G52 36J22, 36J23, 36J24 & 36J52 DSI and HSI Single Stage Combination Gas Valve

OTF Oil Fired Pool Heater

XV 95. Upflow/ Horizontal Left, Downflow/ Horizontal Right Variable Speed Two Stage Condensing Gas-Fired Furnace PUB. NO.

Boston, Venice, Kodiak. Enviro Wood Fireplace Inserts

Boiler Plan II Table of Contents

GALAXY. High performance gas boilers HOT WATER AND STEAM NATURAL AND L.P. PROPANE GASES

Commercial Boiler Systems and Controls

Buderus. Superior Equipment by Design. Comfortable. Efficient. Intelligent Heating. G315 G515 G615 Cast Iron Commercial Boilers.

INSTALLATION AND OPERATION INSTRUCTIONS - (LOW FLOW MODELS) (Before installation, compare electrical needed for the model of heater selected)

1 DESCRIPTION OF THE APPLIANCE

CITYPLEX TOWERS BOILER INSTALLATION ORU RFP-1138

MODEL FLX PACKAGED BOILER

COMMERCIAL COOKING HOODS, VENTILATION & FIRE SUPPRESSION SYSTEM GUIDELINES AND PROCEDURES

REDFYRE CENTRAL-HEATING COOKER (OIL & GAS FIRED)

Cooling Capacity CFM in. w.c. (125 Pa)

Up To 99% Thermal Efficiency HIGH EFFICIENCY COMMERCIAL BOILERS WITH MODBUS PROTOCOL, CASCADING SEQUENCER AND FRONT-END LOADING CAPABILITY

Cooling Capacity CFM in. w.c. (125 Pa)

REGULATORS 175/153 Series

SPARE PARTS EXPLODED VIEW GAS WALL BOILERS Model. CELTIC RSc b CUENOD. R EN - Edition 02-21/04/2005

Owner Retain this manual in a safe place to provide your serviceman information if it becomes necessary.

BB-18 Black Body High Vacuum System Technical Description

NFPA31FuelOilPiping 1 Revised

Munchkin Heat Exchanger Maintenance

Equivalents & Conversion Factors 406 Capacity Formulas for Steam Loads 407 Formulas for Control Valve Sizing

Routine and Emergency Boiler Operation

CABINET. A Clean Burn Heat Exchanger provides approximately 200% more surface area for capturing combustion heat. You get more heat from less oil.

OIL FURNACES CLASSIC PREMIUM CLASS UPFLOW OIL FURNACES. ROBD- SERIES Heating Capacities 56,000 to 151,200 BTU/HR [16.41 to 44.

INTEC Engineering GmbH Heating Solutions for the Marine Industry

Chicago Stationary Engineer Licensure Examination Information

Steam System Best Practices Condensate System Piping

Pump Specifications 250 Series Submersible Sump / Effluent Pump 2 Solids handling

A GUIDE TO SELECTING YOUR INDUSTRIAL OVEN

Commercial Storage Tanks

DRAFT HOOD OUTLET GS6-30-YORT NG Select - Tall - C3 Technology 28 FIRST HOUR RATING BTU INPUT PER HOUR

Model CFC ClearFire Condensing Boiler

INSTRUCTION MANUAL FOR INDOOR & OUTDOOR RITE POWER BURNER FIRED* BOILERS

SCOTCH MARINE FIRETUBE STEAM BOILER MANUAL 3-Pass & 4-Pass Wetback High & Low Pressures BoHP Gas / Oil / Gas & Oil

Electric & Gas Water Heaters

GTS. New! Plus: PR0DUCT CATALOG. Vapor-logic 4 controller with: and LonTalk. New models GTS-500 and GTS-700. Gas-to-Steam Humidification System

HOT WATER SYSTEMS CONTENTS

Chapter. Flares and Stacks. Flares (FLR) Stacks (STK) G2 ICARUS Corporation, 1998.

SAMPLE TEST QUESTIONS STEAMFITTER/PIPEFITTER - ITA WEBSITE

DESIGNER S GUIDE EFFICIENCY+ BOILER

RECON WATER HEATER INSTALLATION FORM

O p t i m i z i n g E n e r g y M a n a g e m e n t w i t h M o d u l a r O n - D e m a n d S y s t e m s. Jason Smith, LEED A.P.

Boiler Installation and Maintenance Manual

Transcription:

918 W WALNUT ST, DANVILLE, KENTUCKY 40422-0048 PHONE (859) 236-3181 www.sellersmfg.com SPECIFICATION SHEET NO. 8302 IMMERSION FIRED STEAM BOILER GENERAL DESCRIPTION The Sellers immersion fired S-Series steam boiler is a horizontal, single pass, firetube boiler designed to burn natural gas. The unique burner assembly delivers pre-mixed air and gas through multiple nozzles. The air-gas mixture is ignited as it exits each flame retaining nozzle at high velocity The resulting flames are long and small in diameter. The flame from each of these nozzles is directed into a 2" O.D. tube that is completely immersed in liquid. There is a separate tube for each flame with the same amount of heat going into each tube. These small diameter flames burn in the first half of the tube lengths. The Sellers single pass design allows small diameter flames to burn in the first half of the tube lengths providing 50% radiant heating surface. The high percentage of radiant heating surface, the low heat input into each tube, and the even distribution of heat throughout the multiple tubes virtually eliminate thermal stress problems that are common in multiple pass boilers. 20 year pressure vessel warranty absolutely no thermal shock industry s lowest life cycle cost Advantages of the Sellers S-SERIES Twenty Year Non Pro-rated Thermal Shock Warranty (Includes Parts & Labor) Full Modulation with Parallel Positioning Controls Single Source Burner - Boiler Package Five Year Non Pro-rated Burner Warranty Lower Emissions. Less Than 50 PPM NOx Standard (30 PPM NOx Available without FGR) Lowest Life Cycle Maintenance Costs Absolutely No Refractory U.L. Labeled Packaged Boiler NET STACK TEMPERATURE AND EFFICIENCY RATING BOILER HORSEPOWER OPERATING PRESSURE 10 PSI 50 PSI 100 PSI 125 PSI 40 200 289 (83.5%) 345 (82.1%) 384 (81.2%) 399 (80.8%) 250 800 267 (84.0%) 321 (82.7%) 359 (81.8%) 373 (81.4%) When unit is in proper adjustment. Net stack temperature based on 70 degree ambient air temperature. Addition of 30 PPM NOx option will lower efficiencies slightly. SELLERS MANUFACTURING CO., MANUFACTURING STEAM AND HOT WATER BOILERS SINCE 1931.

STEAM BOILER RATINGS, CAPACITIES, WEIGHTS BOILER HORSE POWER HOURLY GAS INPUT (1000BTU) (1) From 212 degrees F. feed water to atmospheric pressure. GROSS HOURLY INPUT (1) SEA LEVEL TO 3000 FEET ALTITUDE WATER CAPACITY (U.S. GAL) WATER CAPACITY (POUNDS) SHIPPING WEIGHT (POUNDS) 100 PSI 150 PSI 40 1,674 1,339 139 1,161 2,680 2,680 50 2,092 1,674 224 1,872 3,260 3,260 60 2,511 2,009 219 1,826 3,360 3,360 70 2,929 2,343 213 1,779 3,450 3,450 80 3,348 2,678 319 2,659 4,250 4,330 100 4,184 3,348 307 2,565 4,470 4,470 125 5,231 4,184 424 3,539 5,590 5,860 150 6,277 5,021 411 3,427 5,820 6,090 175 7,323 5,858 397 3,314 6,050 6,320 200 8,369 6,695 534 4,456 7,450 7,580 250 10,461 8,369 654 5,460 9,520 9,520 300 12,553 10,043 839 7,000 11,520 12,110 350 14,645 11,716 806 6,728 12,060 12,490 400 16,738 13,390 1,015 8,471 12,840 13,780 500 20,922 16,738 1,218 10,162 15,080 15,600 600 25,107 20,085 1,446 12,067 17,390 18,520 700 29,291 23,433 1,698 14,168 19,920 21,310 800 33,475 26,780 1,981 16,535 23,330 24,190 GAS REQUIREMENTS Main and pilot gas pressure regulators are supplied with each boiler. Refer to the chart below for gas pressure requirements. Pressures shown are with the unit running. For pressure above 10 PSI, install a second regulator to reduce the pressure to the standard range. BOILER HORSEPOWER PRESSURE REQUIRED AT GAS TRAIN INLET MIN. (3) STD RANGE MAX. 40-80 8" 12 to 1 PSI 10 PSI 100-150 10" 16 to 1 PSI 10 PSI 175-200 14" 20 to 1 PSI 10 PSI 250 14" 2 to 10 PSI 10 PSI 300-350 14" 1.5 TO 10 PSI 10 PSI 400-800 1 PSI 2 TO 10 PSI 10 PSI (3) Special gas trains required at additional cost. For low NOx application with low gas pressure, consult the factory. ELECTRICAL REQUIREMENTS A single incoming power connection is required to the junction box provided at the hinge of all boilers. Boilers are pre-wired (105 C color coded wire) to numbered terminal strips. Panels include a control transformer to provide 5 Amp., 120 Volt service. Boilers are wired for jobsite supply power characteristics. STACK REQUIREMENTS Design stack to provide.02" to.04" water column draft at flue outlet. Smooth transitions and bends are required. Maximum stack weight on boiler should be 1000 pounds on 40 to 80 HP and 2000 pounds for 100 to 800 HP units. AIR REQUIREMENTS Provide 1/2 square foot of free air inlet area per 1,000,000 BTU input to the burner. Cross ventilation is preferred in lieu of a single opening.

STEAM BOILER DIMENSIONS HORSEPOWER 40 50 60 70 80 100 125 OVERALL DIMENSIONS: LENGTH A 144 143 145 149 149 160 160 WIDTH B 42 42 42 48 48 55 55 BURNER WIDTH C 35 35 35 41 41 47 47 BURNER HEIGHT D 65 65 65 70 70 75 75 SECONDARY AIR CAP HEIGHT DD 6 6 6 6 6 6 BASE: WIDTH E 24 24 24 30 30 36 36 LOCATION F 20 20 20 20 20 26 26 LENGTH FF 60 60 60 60 60 60 60 SHELL: LENGTH H 108 108 108 108 108 114 114 DIAMETER INSIDE J 30 30 30 36 36 42 42 SHELL CONNECTIONS: BLOWDOWN SIZE KK 1.25 1.25 1.25 1.25 1.5 1.5 1.5 BLOWDOWN LOCATION K 16 16 16 16 16 22 22 MANUAL FILL SIZE LL MANUAL FILL LOCATION L FEEDWATER INLET SIZE MM 1.5 1.5 1.5 1.5 1.5 1.5 1.5 FEEDWATER INLET LOCATION M 23 23 23 23 23 23 23 STEAM OUTLET LOCATION NN 82 82 82 82 82 88 88 LOW PRESSURE (15 PSI) BOILERS: STEAM OUTLET SIZE (NOTE 3) N 6f 6f 6f 8f 8f 8f 8f HIGH PRESSURE (150 PSI) BOILERS: STEAM OUTLET SIZE (NOTE 3) N 3 3 3 3 3 4F 4F SURFACE BLOWDOWN SIZE P 1.25 1.25 1.25 1.25 1.25 1.25 1.25 GAS CONNECTIONS: VERTICAL LOCATION (NOTE 10) Q 36 36 36 39 39 42 42 HORIZONTAL LOCATION (NOTE 4) R 20 20 22 24 24 28 28 PILOT BURNER VALVE IPS S 0.75 0.75 0.75 0.75 0.75 0.75 0.75 FLUE CONNECTIONS: FLUE SIZE (NOTES 6 & 9) O 10 10 10 12 12 14 14 FLUE LOCATION T 6.5 6.5 6.5 6.5 6.5 4.75 4.75 FLUE HEIGHT TT 49 49 49 55 55 61 61 INSTALLATION CLEARANCES: COMBUSTION ASSEMBLY SWING U 39 39 40 46 46 53 53 RELIEF DOOR SWING (NOTE 7) V 21.5 21.5 21.5 25.5 25.5 29.5 29.5 TUBE REMOVAL, FRONT (NOTE 8) XX 73 73 73 73 73 66 66 TUBE REMOVAL, REAR (NOTE 8) X 71 71 71 71 71 72 72 RELIEF DOOR ASSEMBLY VV 11 11 11 12 12 13 13 FLUE OUTLET PROJECTION Y 2.25 2.25 BLOWER HORSEPOWER: 2 3 5 5 5 7.5 7.5 See Notes on Last Page.

STEAM BOILER DIMENSIONS HORSEPOWER 150 175 200 250 300 350 400 500 600 700 800 OVERALL DIMENSIONS: LENGTH A 167 167 168 194 197 211 214 215 218 220 228 WIDTH B 61 61 67 67 75 77 83 90 96 102 108 BURNER WIDTH C 56 56 62 62 72 76 82 90 96 102 108 BURNER HEIGHT D 79 79 87 87 90 102 107 111 116 124 129 SECONDARY AIR CAP HEIGHT DD BASE: WIDTH E 42 42 48 48 54 54 57 63 66 72 78 LOCATION F 26 26 26 3 3 3 3 3 3 3 3 LENGTH FF 60 60 60 104 104 104 104 104 104 104 104 SHELL: LENGTH H 114 114 114 140 140 140 140 140 140 140 140 DIAMETER INSIDE J 48 48 54 54 60 60 66 72 78 84 90 SHELL CONNECTIONS: BLOWDOWN SIZE KK 1.5 1.5 2 2 2 2 2 2 2 2 2 BLOWDOWN LOCATION K 22 22 22 34 34 34 34 34 34 34 34 MANUAL FILL SIZE LL 2 2 2 2.5 2.5 2.5 2.5 2.5 2.5 2.5 3 MANUAL FILL LOCATION L 61 61 61 82 82 82 82 82 82 82 82 FEEDWATER INLET SIZE MM 2 2 2 2.5 2.5 2.5 2.5 2.5 2.5 2.5 3 FEEDWATER INLET LOCATION M 23 23 23 28 28 28 28 28 28 28 28 STEAM OUTLET LOCATION NN 88 88 88 111 111 111 111 111 111 111 111 LOW PRESSURE (15 PSI) BOILERS: STEAM OUTLET SIZE (NOTE 3) N 8f 10f 10f 10f 12f 12f 12f 12f 12f 12f 14f HIGH PRESSURE (150 PSI) BOILERS: STEAM OUTLET SIZE (NOTE 3) N 4F 6F 6F 6F 6F 8F 8F 8F 8F 8F 10F SURFACE BLOWDOWN SIZE P 1.25 1.25 1.25 1.25 1.25 1.25 1.25 1.25 1.25 1.25 1.25 GAS CONNECTIONS: VERTICAL LOCATION (NOTE 10) Q 45 45 48 48 48 48 48 48 48 48 48 HORIZONTAL LOCATION (NOTE 4) R 32 32 32 34 34 48 50 50 50 50 56 PILOT BURNER VALVE IPS S 0.75 0.75 0.75 0.75 1 1 1 1 1.25 1.25 1.25 FLUE CONNECTIONS: FLUE SIZE (NOTES 6 & 9) O 16 18 18 20 22 24 26 28 32 34 36 FLUE LOCATION T 3.75 2.75 2.75 5.75 4.5 3.5 2.5 1.5-0.5-1.5-2.5 FLUE HEIGHT TT 67 67 73 73 79 79 85 91 97 103 109 INSTALLATION CLEARANCES: COMBUSTION ASSEMBLY SWING U 62 62 67 67 74 88 90 96 101 106 114 RELIEF DOOR SWING (NOTE 7) V 35.5 35.5 40 40 43 43 46 50 48 50 52 TUBE REMOVAL, FRONT (NOTE 8) XX 66 66 66 88 88 88 88 88 88 88 88 TUBE REMOVAL, REAR (NOTE 8) X 72 72 72 90 90 90 90 90 90 90 90 RELIEF DOOR ASSEMBLY VV 14 14 15 15 16 16 17 18 17 18 18 FLUE OUTLET PROJECTION Y 4.25 6.25 6.25 4.25 8.5 10.5 12.5 14.5 18.5 20.5 22.5 BLOWER HORSEPOWER: 7.5 7.5 10 10 15 15 15 20 20 25 30 See Notes on Last Page.

NOTES 1. Dimensions are accurate for layout but are subject to change. Certified prints are available upon request. 2. Lifting lugs and insulation are not shown on drawing. The manhole, when furnished, is not shown. 3. Openings are threaded unless indicated: f = Class 150 ASA flange. F = Class 300 ASA flange. Threaded couplings project 2 or less. 4. Provide R + 12 clearance from the right side of burner box to the right side wall to open hinged burner. 5. Gas train may change with gas type and pressure. 6. Outside diameter and dimensions are shown. (see note 10) 7. Provide J + 7 clearance from the rear end of the shell to swing the hinged back plate on 200 HP and larger boilers. 8. Tubes may be removed from the front or rear. 9. Dip tube (2" min.) provided on hot water outlet. 10. Flue outlet dimension on 300 HP and larger boilers are inside diameter with angle iron flanged connection. 11. Horizontal gas train dimension will vary based on required gas train components and addition of Low NOx option. Gas train may extend beyond burner manifold dimension C. Model Number Designations PRESSURE SIZE 40-125 HP 150-800 HP 15 PSI 150 PSI MODEL 15C MODEL 15SR MODEL 77C MODEL 105E STANDARD EQUIPMENT FURNISHED Pressure Vessel: 15 PSI ASME stamped with H cloverleaf. 150 PSI ASME stamped with S cloverleaf. Manholes: Standard on 400 HP or larger low pressure boilers and 200 Hp and larger high pressure boilers. Handholes: Five (5) furnished, 3-1/2" x 4-1/2". Energy X-tractors: High temperature stainless steel to provide high efficiency. Installed in each tube. Insulation: 2" fiberglass with double painted steel jacket with precast hardtop walkway. Relief Door: Gravity operated for rear access and safety. Burner Assembly: Hinged to shell including: Fully modulating burner with parallel positioning controls. Individual burner nozzles. Air proving switch. Ignition transformer, spark and flame rods. Gas control trains with dual main shutoff cocks, pilot and main gas pressure regulators, gas volume adjustment and other components as follows: Operating Pressure Control: Controls temperature. High Limit Pressure Control: Manual reset limit control. UL Labeled: Packaged boiler. Low Water Cutoffs: MM157 with pump control switch. MM150-M secondary with manual reset (Probe on 15 PSI). Pressure Gauge: 4-1/2 dial type mounted on pigtail. Lifting lugs: One or more provided on each boiler. Base: Heavy duty structural steel skid. Relief Valve(s): ASME rated for full boiler nozzle output at design pressure rating. Flame observation ports: Two or more provided in combustion chamber to view burners. Control Panel: With motor starter, control transformer with primary and secondary fuses & indicating lights. Siemens LMV5 Microprocessor based burner management system with real time MODBUS communication. 40-50HP 60-100HP 125HP 150-250HP 300-800HP MOTORIZED GAS VALVE 1 1 2 2 2 PROOF OF CLOSURE SWITCH 1 1 1 1 1 PILOT SOLENOID VALVES 1 1 2 2 2 GAS PRESSURE SWITCHES - 2 2 2 2 VENT VALVE - - - - 1

Sellers sellers Manufacturing manufacturing has a Series has a of series Immersion of immersion boiler to boiler fit almost to fit almost any application. any application S-Series Includes all the advantages of the Immersion Boiler with a fully modulating burner package. For use in variable load and 30 PPM NOx applications. M-Series Modulating Immersion Boiler with ultra-low NOx capabilities. For use in sub 9 PPM NOx applications. X-Series On-Off Immersion Boiler package. For use with industrial applications that require full capacity more than 75% of its operating cycle. H-Series Nonferrous, chemical free 15 PSI Immersion steam boiler. For use in humidification and chemical free applications. P-Series Immersion plain tube boiler design offers most versatile fuel uses and simple operation with natural gas, propane and methane fuels. For more information on any of the Sellers Immersion Boiler Series visit www.sellersmfg.com 918 W WALNUT ST, DANVILLE, KENTUCKY 40422-0048 PHONE (859) 236-3181 WWW.SELLERSMFG.COM