Appendix C Network Cabling

Similar documents
Copper Gigabit Switch Installation Guide

24 PORT. Copper Gigabit Switch Installation Guide. 10/100/1000 Mbps MODEL GS 524 T

Chapter 2 TCP/IP Networking Basics

The Evolution of Copper Cabling Systems from Cat5 to Cat5e to Cat6 Copper Cabling Standards and Technical Aspects

Network Design. Yiannos Mylonas

Appendix B Network, Routing, Firewall, and Basics

5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual

LFH4-M/LFH8-M Mini Fast Hubs. Installation Guide

LevelOne IFE Port PoE + 1-Port TP Industrial Fast Ethernet Switch User Manual

Running 1000BASE-T Gigabit Ethernet over Copper Cabling 30 March 1999 Colin Mick/The Mick Group with Bruce Tolley/3Com and Willem Wery/Intel

Gigabit Switching Ethernet Media Converters - Product User Guide

TCP/IP Networking Basics. NETGEAR, Inc Great America Parkway Santa Clara, CA USA

Presenters Brett Weiss, Gabe Martinez, Brian Kroeger.

ANSI/TIA/EIA A, Commercial Building Telecommunications Cabling Standard.

The Permanent Link in Field Certification Reasons, Advantages, Testing Challenges

Gigabit Ethernet on Copper Cabling Infrastructures

Mixed High-Speed Ethernet Operations over Different Categories of Bundled UTP Cable

Things You Must Know About Gigabit Ethernet 1. Understanding Gigabit Ethernet

Ethernet Patch Cord Wiring

16-Port and 24-Port 10/100 Switches

Enhanced Category 5 Cabling System Engineering for Performance

Planning for 10Gbps Ethernet over UTP Questions to Ask When Planning the Cabling Plant WHITE PAPER

IMMS-CCC. IMMS-CCC Hardwire Central Interface. Installation Instructions

USER MANUAL MODEL 2300M SERIES. OpticLink Ethernet Media Converters (2300M, 2310M, 2311M, & 2312M)

Specification SFTP CAT6 Network Cable 23AWG CU

How to Choose the Right Cable Category

Copper Patch Cords. Impact On Network Performance and Reliability

Quick Installation Guide 24-port PoE switch with 2 copper Gigabit ports and 2 Gigabit SFP ports (af Version 15.4W)

Testing 10 Gb/s Performance of Category 6 and 6A Structured Copper Cabling Systems within the Unified Physical Infrastructure SM (UPI)

Choosing the Cable Infrastructure

Session 2; Cabling Technology in the Data Centre Media Choices; Copper Twisted Pair

MDI/MDIX) FEP-32008T-3

Data Communications Competence Center

Implementing Fast Ethernet

Cisco - Ethernet 100BaseTX and 10BaseT Cables: Guidelines and Specifications

Start Here. Features. Model EN104/EN108/EN116 Ethernet Hub Installation Guide

Smart Switch Series Software Manual

Standards Affecting a Premise T-1 Installation

Installation Effects Upon Alien Crosstalk and Equal Level Far End Crosstalk

Network Cabling Guide

Network Engineers Everywhere:

Digital Systems Ribbon Cables I CMPE 650. Ribbon Cables A ribbon cable is any cable having multiple conductors bound together in a flat, wide strip.

LMR16TC Mini 10BASE-T Repeater. Installation Guide

HP ProCurve High-Speed Transceivers Installation Guide

Full_IG.book Page 1 Monday, January 9, :11 PM. ProSafe 24 Port Gigabit Switch Installation Guide

PROFINET Diagnostics Software and Tools

Model 0400 (800) MODEL 0400 ETHERNET POCKET HUB SPECIFICATIONS (E-TBT-HB-0400) Standards. Physical

Terminating 25-Pair Cable and 4-Pair Cross Connects

The High Cost of a Low-Cost Cable Certification Tester

Chapter 4 Connecting to the Internet through an ISP

1.1 SYSTEM DESCRIPTION.1 Data system includes data outlets and wiring for office and school applications.

IT Cabling Solutions

Accelerating Light. Copper Cabling Solutions. Category 6A

GEU Port Gigabit Switch

Networking 101 (Networking Basics) Presentation to UCHUG - 1/03/07 G. Skalka

USER S MANUAL. Ethernet 10/100 Transceiver Series DL221/DL221A

5-Port Switch 10/100/1000 Mbps Gigabit Ethernet GS105

White Paper: 10 Gigabit Ethernet over Twisted Pair Copper Systems

HIGH SPEED COMMUNICATIONS PLENUM CABLE CATEGORY 5e CMP FEP JACKETED, PVC-FREE UNSHIELDED TWISTED PAIR (UTP)

2-Pair. Managed SHDSL Ethernet Extender. User s Manual

D-Link DES-1024D 24-Port 10/100Mbps Ethernet Switch. Manual

Modular Fast Ethernet Switch

4-Port Switch. 10/100/1000 Mbps Gigabit Ethernet GS104. Installation Guide

Provides one channel for Ethernet over existing

Gigabit eco-friendly Ethernet Switch AT-GS900/8. Installation Guide Rev. A

8-Port PoE Network Switch

Copper to Fiber Stand-Alone Media Converter. Quick Installation Guide

FSW-0505TX/0805TX 5/8 Port SOHO 10/100Mbps NWay Switch FSW-0505TX FSW-0805TX. 5/8 Port SOHO 10/100Mbps NWay Switch. User s Manual. (Revision 1.

LMR8TT Mini 10BASE-T Hub/Repeater

VE02AL / VE05AL / VE02ALR VGA & Stereo Audio CAT5 Extender with Chainable Output

Data Center. Pre-terminated. Patch Panel System. Cabling Systems Simplified. Patch Panels. 10G + Gigabit. Patch Cords. Plug & Play Installation

CAT 5 Cable / RJ 45 Connectors and Making Cables for different connections

Category 6 UTP - Cabling System

HARTING Ethernet Cabling 8-poles Overview

How to Determine the Right Fiber Optic Network Backup Switch For Your Application

Quick Installation Guide. 16-Port 10/100Mbps Fast Ethernet Switch

Category 6 Solutions. 4. Category 6 Solutions. 09/ IN TrueNet Structured Cabling. Introduction Cable Patch Panels... 4.

Requirements for Modular Patch Cords (e.g. RJ45 patch cords for Cat5 and Cat6 cabling systems)

Quick Installation Guide 8-Port 10/100/1000Mbps Green Switch

Gigabit Ethernet Switch 10/100/1000 Mbps GS605 / GS608. Installation Guide

SMARTen 24 STP Patch Panels

SMARTen 24 UTP Patch Panels

FlexPoint T1/E1 Copper to Fiber Line Driver

Provides one channel for Ethernet over existing

Networks. The two main network types are: Peer networks

MICROSENS Media Converter 10/100/1000T to Gigabit Fiber

16-Port and 24-Port 10/100/1000 Gigabit Switches

ATT-TP Ethernet Copper Cable & Ethernet Copper Assembly Specification

IEEE 802.3af 4-Port Power over Ethernet Injector Hub POE-400. User s Manual

Resolution of comments 242 and 267 on Insertion loss measurements of installed fiber cables. Steve Swanson May 5, 2009

NS-205-IP67 5-Port Industrial 10/100 Mbps Ethernet Switch with IP67 Casing

R&Mfreenet Advanced Cat 6 A Unshielded Connection Module

Fast Ethernet and Gigabit Ethernet. Networks: Fast Ethernet 1

INTRODUCTION TO 100BASE-T: FAST (AND FASTER) ETHERNET

LAN Installation Handbook

16-port Gigabit Switch 10/100/1000 Mbps GS116. Installation Guide

Total Solutions Verification

Power Over Ethernet Adapters POE101

PoE+ Extender Switch User's Manual. Rev W

PANDUIT TX6 10GIG SHIELDED COPPER CABLING SYSTEM. Innovative Connectivity Solution for Maximum Performance and Security

Transcription:

Appendix C Network Cabling This appendix provides specifications for cables used with a NETGEAR GS108T Gigabit Smart Switch. Fast Ethernet Cable Guidelines Fast Ethernet uses UTP cable, as specified in the IEEE 802.3u standard for 100BASE-TX. The specification requires Category 5 UTP cable consisting of either two-pair or four-pair twisted, insulated copper conductors bound in a single plastic sheath. Category 5 cable is certified up to 100 MHz bandwidth. 100BASE-TX operation uses one pair of wires for transmission and the other pair for receiving and for collision detection. When installing Category 5 UTP cabling, use the following guidelines to ensure that your cables perform to the following specifications: Certification. Ensure that your Category 5 UTP cable has completed the Underwriters Laboratories (UL) or Electronic Testing Laboratories (ETL) certification process. Termination method. To minimize cross-talk noise, maintain the twist ratio of the cable up to the point of termination; untwist at any RJ-45 plug or patch panel should not exceed 0.5 inch (1.5 cm). Category 5 Cable Category 5 distributed cable that meets ANSI/EIA/TIA-568-A building wiring standards can be a maximum of 328 feet (ft.) or 100 meters (m) in length, divided as follows: 20 ft. (6 m) between the hub and the patch panel (if used) 295 ft. (90 m) from the wiring closet to the wall outlet 10 ft. (3 m) from the wall outlet to the desktop device The patch panel and other connecting hardware must meet the requirements for 100 Mbps operation (Category 5). Only 0.5 inch (1.5 cm) of untwist in the wire pair is allowed at any termination point. Network Cabling C-1

Category 5 Cable Specifications Ensure that the fiber cable is crossed over to guarantee link. Table C-1 lists the electrical requirements of Category 5 UTP cable. Table C-1. Electrical Requirements of Category 5 Cable Specifications Category 5 Cable Requirements Number of pairs Twisted Pair Cables Four Impedance 100 ± 15% Mutual capacitance at 1 KHz Maximum attenuation (db per 100 m, at 20 C) 5.6 nf per 100 m At 4 MHz: 8.2 At 31 MHz: 11.7 At 100 MHz: 22.0 NEXT loss (db minimum) At 16 MHz: 44 At 31 MHz: 39 At 100 MHz: 32 For two devices to communicate, the transmitter of each device must be connected to the receiver of the other device. The crossover function is usually implemented internally as part of the circuitry in the device. Computers and workstation adapter cards are usually media-dependent interface ports, called MDI or uplink ports. Most repeaters and switch ports are configured as media-dependent interfaces with built-in crossover ports, called MDI-X or normal ports. Auto Uplink technology automatically senses which connection, MDI or MDI-X, is needed and makes the right connection. C-2 Network Cabling

Figure C-1 illustrates straight-through twisted-pair cable. Figure C-1 Figure C-2 illustrates crossover twisted-pair cable. Figure C-2 Patch Panels and Cables If you are using patch panels, make sure that they meet the 100BASE-TX requirements. Use Category 5 UTP cable for all patch cables and work area cables to ensure that your UTP patch cable rating meets or exceeds the distribution cable rating. To wire patch panels, you need two Category 5 UTP cables with an RJ-45 plug at each end, as shown in Figure C-3. Network Cabling C-3

Figure C-3 Note: Flat silver satin telephone cable might have the same RJ-45 plug. However, using telephone cable results in excessive collisions, causing the attached port to be partitioned or disconnected from the network. Using 1000BASE-T Gigabit Ethernet over Category 5 Cable When you use the new 1000BASE-T standard, you must consider the limitations of cable installations and the steps necessary to ensure optimum performance. The most important components in your cabling system are patch panel connections, twists of the pairs at connector transition points, the jacket around the twisted-pair cable, bundling of multiple pairs on horizontal runs, and punch down blocks. All of these factors affect the performance of 1000BASE-T technology if not correctly implemented. The following sections are designed to act as a guide to correct cabling for 1000BASE-T. Cabling The 1000BASE-T product is designed to operate over Category 5 cabling. To further enhance operation, the cabling standards have been amended. The latest standard is Category 5e, which defines a higher level of link performance than is available with Category 5 cable. C-4 Network Cabling

If installing new cable, NETGEAR recommends using Category 5e cable, since it costs about the same as Category 5 cable. If using the existing cable, be sure to have the cable plant tested by a professional who can verify that it meets or exceeds either ANSI/EIA/TIA-568-A:1995 or ISO/ IEC 11801:1995 Category 5 specifications. Length The maximum distance limitation between two pieces of equipment is 100 m, as per the original Ethernet specification. The end-to-end link is called the channel. TSB-67 defines the basic link, which is the portion of the link that is part of the building infrastructure. This excludes patch and equipment cords. The maximum basic link length is 295 feet (90 m). Return Loss Return loss measures the amount of reflected signal energy resulting from impedance changes in the cabling link. The nature of 1000BASE-T renders this measurement very important; if too much energy is reflected back onto the receiver, the device does not perform optimally. Unlike 10BASE-T and 100BASE-TX, which use only two of the four pairs of wires within the Category 5 cable, 1000BASE-T uses all four pairs of the twisted pair. Make sure all wires are tested this is important. Factors that affect the return loss are: The number of transition points, as there is a connection through an RJ-45 to another connector, a patch panel, or device at each transition point. Removing the jacket that surrounds the four pairs of twisted cable. NETGEAR strongly recommends that, when RJ-45 connections are made, this is minimized to 1 1/4 inch (32 mm). Untwisting any pair of the twisted-pair cabling. It is important that any untwisting be minimized to 3/8 inch (10 mm) for RJ-45 connections. Cabling or bundling of multiple Category 5 cables. This is regulated by ANSI/EIA/TIA-568A-3. If not correctly implemented, this can adversely affect all cabling settings. Near End Cross Talk Near End Cross Talk (NEXT) is a measure of the signal coupling from one wire to another, within a cable assembly, or among cables within a bundle. NEXT measures the amount of cross-talk disturbance energy that is detected at the near end of the link the end where the transmitter is Network Cabling C-5

located. NEXT measures the amount of energy that is returned to the sender end. The factors that affect NEXT and cross talk are exactly the same as outlined in the Return Loss section. The cross-talk performance is directly related to the quality of the cable installation. Patch Cables When installing your equipment, replace old patch panel cables that do not meet Category 5e specifications. As pointed out in the Near End Cross Talk section, this near end piece of cable is critical for successful operation. RJ-45 Plug and RJ-45 Connectors In a Fast Ethernet network, it is important that all 100BASE-T certified Category 5 cabling use RJ-45 plugs. The RJ-45 plug accepts 4-pair UTP or shielded twisted-pair (STP) 100-ohm cable and connects into the RJ-45 connector. The RJ-45 connector is used to connect stations, hubs, and switches through UTP cable; it supports 10 Mbps, 100 Mbps, or 1000 Mbps data transmission. Figure C-4 shows an RJ-45 plug and RJ-45 connector with built-in LEDs. Figure C-4 Table C-2 lists the pin assignments for the 10/100 Mbps RJ-45 plug and the RJ-45 connector. Table C-2. 10/100 Mbps RJ-45 Plug and RJ-45 Connector Pin Assignments Pin Normal Assignment on Ports 1 to 8 Uplink Assignment on Port 8 1 Input receive data + Output transmit data + 2 Input receive data Output transmit data 3 Output transmit data + Input receive data + C-6 Network Cabling

Table C-2. 10/100 Mbps RJ-45 Plug and RJ-45 Connector Pin Assignments (continued) Pin Normal Assignment on Ports 1 to 8 Uplink Assignment on Port 8 6 Output transmit data Input receive data 4, 5, 7, 8 Internal termination, not used for data transmission Table C-3 lists the pin assignments for the 100/1000 Mbps RJ-45 plug and the RJ-45 connector. Table C-3. 100/1000 Mbps RJ-45 Plug and RJ-45 Connector Pin Assignments Pin Channel Description 1 2 3 6 4 5 7 8 A Rx/Tx data + Rx/Tx data B Rx/Tx data + Rx/Tx data C Rx/Tx data + Rx/Tx data D Rx/Tx data + Rx/Tx data Conclusion For optimum performance of your 1000BASE-T product, it is important to fully qualify your cable installation and ensure that it meets or exceeds ANSI/EIA/TIA-568-A:1995 or ISO/IEC 11801:1995 Category 5 specifications. Install Category 5e cable where possible, including patch panel cables. Minimize transition points, jacket removal, and untwisted lengths. Cable bundles must be correctly installed to meet the requirements in ANSI/EIA/TIA-568A-3. Network Cabling C-7

C-8 Network Cabling