LARGE SCALE AMMONIA STORAGE AND HANDLING DAN WEBB MGR., ENG. & TECH. SVCS. CF INDUSTRIES, INC. LONG GROVE, IL

Similar documents
Open Cycle Refrigeration System

How does solar air conditioning work?

UNIT 2 REFRIGERATION CYCLE

UNDERSTANDING REFRIGERANT TABLES

Chapter 2 P-H Diagram Refrigeration Cycle Analysis & Refrigerant Flow Diagram

How To Clean Water From An Ammonia Refrigeration System

SECTION 5 COMMERCIAL REFRIGERATION UNIT 22 CONDENSERS

Refrigeration Basics 101. By: Eric Nelson

How To Design A Refrigeration System

No. Name Description Main input Data Main Output Data. cooling duty, process in/out temperature, inlet air temperature

COMMERCIAL HVAC CHILLER EQUIPMENT. Air-Cooled Chillers

Equivalents & Conversion Factors 406 Capacity Formulas for Steam Loads 407 Formulas for Control Valve Sizing

Rusty Walker, Corporate Trainer Hill PHOENIX

Optimization of Industrial Refrigeration Plants: Including a Case Study at Stonyfield Farm Yogurt

Compressors Buying Guide

Geothermal Alliance of Illinois. TXVs Theory and Fundamentals John Haug Senior Application Engineer Emerson Climate Technologies - Flow Controls

ARP Food Industry, Portugal

Commercial refrigeration has been in the environmental. Refrigerant. as a. Basics Considerations PART 1:

ABSTRACT. aspects of potential waste heat recovery systems and the economics of installing them at selected survey factories.

COURSE TITLE : REFRIGERATION AND AIR CONDITIONING COURSE CODE : 4029 COURSECATEGORY : A PERIODS/WEEK : 5 PERIODS/SEMESTER : 90 CREDITS : 4 OBJECTIVES

Heat Recovery In Retail Refrigeration

Chapter 3.4: HVAC & Refrigeration System

How To Understand Evaporator

Clean Abundant and Economical Natural Gas

CPX/HT Series. REFRIGERATED AND HIGH TEMPERATURE DRYER 12 to 2400 CFM. High-performance products. Designed for you!

Ground Source Heat Pumps The Fundamentals. Southington, Connecticut John F. Sima III P.E.

Engineering Recommendation on: Accumulators Revised Issued January 10, 1979 Page 1 of 7

Any Service Technician Can Fix It A Good Service Technician Can Figure Out What s Wrong With It.

8. Refrigeration. 4. Liquid. Refrigerant. 4. Liquid Refrigerant. Figure 8.1 Refrigeration system layout (single stage)

It will be available soon as an 8.5 X 11 paperback. For easier navigation through the e book, use the table of contents.

Why and How we Use Capacity Control

COMMERCIAL HVAC EQUIPMENT. Condensers and Cooling Towers

Thermal Coupling Of Cooling and Heating Systems

Watco Companies, L.L.C. NUTC Oil Panel Discussion Terminal Perspective Evanston, IL June 11, 2014 Stefan Loeb SVP Marketing & Strategic Development

Ground-breaking conversion of critical Data Room WaterChiller from R22 to R422D / MO29

MAINTENANCE INSTRUCTIONS. Thermia Robust heat pump

Characteristics of Evaporators

Humidity, Condensation, Clouds, and Fog. Water in the Atmosphere

HVAC and REFRIGERATION

High Pressure Ammonia Systems New Opportunities

Low GWP Replacements for R404A in Commercial Refrigeration Applications

VACUUM REFRIGERATION SYSTEMS

How To Calculate The Performance Of A Refrigerator And Heat Pump

THE PSYCHROMETRIC CHART AND ITS USE

In the compression-refrigeration loop (air conditioning), which is likely to be warmer? 1. Condenser coil 2. Evaporator coil

Scroll Compressor Development for Air-Source Heat Pump Water Heater Applications

Recharge Procedure for Telemark TVP-2000 and TVP-3500

Heat Pipe Selection Revision 12/04/2001

THE HUMIDITY/MOISTURE HANDBOOK

Liquid level measurement using hydrostatic pressure and buoyancy

Condensate Treatment Solutions. CTS Series Eliminator II Oil-Water Separators

Vacuum. How It Relates to Refrigeration And Air Conditioning Service

Appendix C. Minimum Equipment Efficiency Standards

POLICY BULLETIN Tecumseh Compressor Company Compressor Group

CHAPTER 7 THE SECOND LAW OF THERMODYNAMICS. Blank

Refrigeration Installation 101

Chapter 10: Refrigeration Cycles

RS-52 (R428A) RS-52: PHYSICAL PROPERTIES RS-52 R502 Molecular weight Temperature glide o C Boiling point (1 atm)

IMO WORK PROGRAMME OF THE COMMITTEE AND SUBSIDIARY BODIES

That s it, that s what we do: air knife drying. Ray Ralph, President R.E. Morrison Equipment Inc.

Lesson. 11 Vapour Compression Refrigeration Systems: Performance Aspects And Cycle Modifications. Version 1 ME, IIT Kharagpur 1

Contents and Nomenclature

HVAC Systems: Overview

Thermodynamics - Example Problems Problems and Solutions

Compressed Air Systems

OUR PRODUCTS TRH-TRS-TRM-TRV. LIQUID RING VACUUM PUMPS AND COMPRESSORS Capacity up to 2100 ACFM Vacuum to 29 Hg. Our Other Products.

ECONOMICAL OPTIONS FOR RECOVERING NGL / LPG AT LNG RECEIVING TERMINALS

Table Z. Troubleshooting Chart for Air Conditioners. Cause

GEOTHERMAL HEATING AND COOLING INTRODUCTION

Farmowners Equipment Breakdown Coverage. Frequently Asked Questions

A basic introduction to steam

CHAPTER 9: WATER HEATING

Advanced Heat Reclaim Systems. Harrison Horning, PE, CEM Delhaize America - Hannaford

Refrigerated Compressed Air Dryers

Compressed air systems. How to plan, install and operate. Best Practices for Maintenance Management

Increasing the evaporation temperature with the help of an internal heat exchanger

Inverter and programmable controls in heat pump applications

Table V. Troubleshooting Checklist for Refrigeration Systems. Air or non-condensable gas in system. Inlet water warm.

Cooling Systems 2/18/2014. Cooling Water Systems. Jim Lukanich, CWT ChemCal, Inc. Grapevine, TX

Purpose of Refrigeration

CONTENTS. ZVU Engineering a.s., Member of ZVU Group, WASTE HEAT BOILERS Page 2

ALUMINUM. BestPractices Assessment Case Study. Alcoa North American Extrusions Implements Energy Use Assessments at Multiple Facilities.

REFRIGERATION (& HEAT PUMPS)

Air Eliminators and Combination Air Eliminators Strainers

Sheet 5:Chapter 5 5 1C Name four physical quantities that are conserved and two quantities that are not conserved during a process.

Warm medium, T H T T H T L. s Cold medium, T L

How to Choose the Right Air Compressor

Technical Training Associates Presents. Commercial Refrigeration Equipment Servicing Part 1

Ductless Split Air Conditioner

Ingersoll Rand Providing Customer-Driven Air System Solutions for More Than 100 Years

DIRECT STEAM INJECTION HOT WATER SYSTEMS FOR JACKETED HEATING

How To Use A Water Source Heat Pump

The paper addresses the boil-off in the cryogenic industry and details the specifics of it when applied to vehicle LNG tanks.

LG Electronics AE Company, Commercial Air Conditioning

Postharvest Sample Questions

Fuel and Energy Conversion and Equivalence Chart

InvestSmart Business Energy Upgrades Refrigeration Solutions Equipment Catalog 01/01/2015

Refrigeration and Airconditioning Prof. M. Ramgopal Department of Mechanical Engineering Indian Institute of Technology, Kharagpur

Federal Wage System Job Grading Standard for Air Conditioning Equipment Mechanic, Table of Contents

INSTALLATION INSTRUCTIONS Fan Coil Replacement Coil Kit EBX & EBXX

Transcription:

LARGE SCALE AMMONIA STORAGE AND HANDLING DAN WEBB MGR., ENG. & TECH. SVCS. CF INDUSTRIES, INC. LONG GROVE, IL 1

Presentation Overview Why are these facilities needed? Why is refrigeration needed? What are the major components? How is ammonia transported to and from the facilities? What are special challenges and opportunities? 2

Why are these facilities needed? Ammonia is a very concentrated form of nitrogen fertilizer for agricultural crops Shipping demands to local supply centers and farms is short duration and high volume Ammonia is produced continually and must be stored until needed Physical properties of ammonia demand high pressure storage vessels or refrigeration 3

Why is refrigeration needed? A typical facility stores from 15,000 to 60,000 tons of ammonia to meet shipping needs Full pressure, shop fabricated, storage vessels are practical to about 300 tons (you would need 50 to 200 per site) By storing ammonia in a refrigerated state, very large tanks are practical (as high as 17.5 million gallons) 4

Why is refrigeration needed? (cont.) Ammonia, in addition to being a good fertilizer, is a good refrigerant By keeping the stored product temperature low, the pressure stays low By keeping the stored product pressure low, the temperature stays low (-28F at 0 psig.) 5

Major Components 126 to 170 ft. in diameter 60 to 105 ft. high Low Pressure Storage Tank (LPST) 6 to 12 million gallon capacity (15-30,000 tons) usually 1 psig max. internal pressure (~-28F) heat leaks in from environment 6

7

Major Components (cont.) Compressor moves vapor, increases pressure reciprocating, rotary screw, rotary vane, etc 10 to 300 horsepower each (75 to 1200 hp total) compression ratio dependent on type required capacity dependent on inbound type compression causes temperature increase 8

9

Major Components (cont.) can be vertical or horizontal vessel usually designed for 250 psig. provides direct contact cooling removes superheat from vapor vapor out vapor in liquid in liquid out Flash Tank or Intercooler 10

flash tank 11

Major Components (cont.) can be air-cooled, evaporative, or shell-andtube usually designed for 250 psig. removes superheat and latent heat changes vapor to liquid Condensers 12

vapor in water in liquid out evaporative condenser water out 13

Major Components (cont.) liquid in liquid out usually a horizontal vessel usually designed for >= 250 psig. provides liquid seal provides surge capacity Receiver 14

15

Refrigeration in an Ammonia Storage Facility 16

Superheated vapor passes from the storage tank to the 1st stage of compression. Vapor is compressed from less than 1 psig. up to 30-60 psig. 17

Hot vapor from 1st stage compression is cooled in the flash tank in preparation for 2nd stage compression. 18

Vapor near its saturation temperature passes to 2nd stage compression. Vapor is compressed from 30-60 psig up to condensing pressure of 150 to 225 psig. 19

Hot vapor passes to the condenser, where heat is rejected to the environment. 20

Condensed ammonia gravity drains into the receiver. 21

Receiver level control sends liquid to flash tank for an intermediate flash on its way back to the storage tank. 22

Flash tank level control sends liquid, at intermediate pressure, to the storage tank. 23

A flare for burning of ammonia vapor during a refrigeration system interruption and a knockout pot to protect the compressors from damaging liquid entry are also utilized. This completes the holdingrefrigeration system. 24

Ammonia Inbound to a Storage Facility 25

Cold Inbound Refrigerated Barge/Ship Cold inbounding of ammonia is done by pumping directly to the storage tank (250 to 750 tons per hour) Refrigeration 26

Warm inbounding of ammonia can be done by taking the product directly to the storage tank. Warm Inbound Rail Truck Pipeline Refrigeration 27

Instead,warm inbounding of ammonia is usually done by passing the product through the flash tank to increase efficiency. Rate is limited by refrigeration capacity (usually 5-20 tons per hour). Warm Inbound Rail Truck Pipeline Refrigeration 28

A high pressure bullet is typically used to provide surge capacity for warm product inbounding (100 to 300 tons). Warm Inbound Rail Truck Bullet Pipeline Refrigeration 29

Cold Inbound Warm Inbound Refrigerated Barge Rail Truck Pipeline Bullet Refrigeration 30

Ammonia Shipping 31

Rail Truck +40F Low Pressure Storage Tank -28F Natural Gas Cold ammonia must be heated before loading onto trucks or rail cars. 32

Rail Truck Warm Inbound Bullet Warm, high pressure ammonia +40F Low Pressure Storage Tank -28F Natural Gas Warm ammonia from inbound can be loaded directly onto outbound vehicles or mixed with heated product for shipping. Direct transfer saves refrigeration and heating energy if the facility has a bullet. 33

Rail Rack Compressor Building 30,000 ton storage tanks Bullet Truck Loading 34

Challenges and Opportunities Ammonia stinks! (that s good and bad) Storing millions of gallons of ammonia presents environmental, health, and safety concerns. PSM and RMP very much affect this industry. Ammonia handling is very energy intensive and competitive. 35

Challenges and Opportunities (cont.) Energy prices are hitting ammonia manufacturing and handling very hard! Many of the facilities were built in the 60 s and 70 s and need to be upgraded to newer technology. 36

Questions/Comments? 37