EL 12 E3K. EL 24kV B785 ELEKTROTECHNISCHE WERKE FRITZ DRIESCHER & SÖHNE GMBH. Operating Instruction for DRIESCHER - Circuit - breaker panels

Similar documents
ELEKTROTECHNISCHE WERKE FRITZ DRIESCHER & SÖHNE GMBH D MOOSBURG TEL FAX

MEDIUM VOLTAGE CE-BF SWITCHBOARDS. UP TO 40.5 kv. CE - BF - C - en - REV

The following components are common to most cubicles; this example is an ABB HK cubicle.

UniGear ZS1. Medium voltage, arc proof, air insulated switchgear for primary distribution

Unified requirements for systems with voltages above 1 kv up to 15 kv

Voltage Rated operating voltage [kv] Rated power frequency withstand voltage [kv] Rated lightning impulse withstand voltage [kv]

Advantages of Fixed Circuit Breaker Switchgear

NATUS NES / NES-H Draw-out Type Medium Voltage Switchgear Systems. Safe energy distribution that meets the highest industrial requirements

Our brand POWER DYNAMIC PASSION COMMITMENT CREATIVITY. A strong brand for strong products: 8PU Premium. MV Energy

The Intelligent AX1 Switchgear for Medium Voltage

2a. IEM Indoor Metal Clad Medium Voltage Switchgear 15KV a. Section INDOOR METAL CLAD MEDIUM VOLTAGE SWTICHGEAR (Std.

MEDIUM AND HIGH VOLTAGE CAPACITORS, CAPACITOR BANKS AND SYSTEMS

e 2 ALPHA Medium Voltage Switchgear Data Sheet K EN

High-Voltage Compact Switchgear 3AP1 DTC for 145 kv and 245 kv

Sample - No Commercial Use

3.1.1 Full Type Tests & Routine Tests according to Clause 8 2 & Instructions For Installation, Operation & Maintenance

Medium Voltage Products. ZN1 12 kv arc-proof air-insulated switchgear for primary distribution

Product brochure Multi Functional Switchgear PASS M kv Flexible and compact switchgear solutions for windfarms

Type-Tested Power Distribution Board 8PT with Rear Busbars. sivacon

Medium Voltage Switchgear

MEDIUM VOLTAGE SWITCHGEAR CATALOGUE. Code: P2490_xx

FAQs-Main switchboard design criteria

Emirates Aluminium starts up World s first fully integrated power distribution system from ABB

Eaton Safety & Reliability Solutions in the Oil & Gas Industry Electrical

Specification Guide. for RVAC. Direct Replacement. AC Medium Voltage. Circuit Breakers

Modular Systems wind portfolio overview Power Collection and Grid Connection products

ELECTRICAL INSULATION TESTING OF HV EQUIPMENT UP TO 33kV

Nothing s BetterThan the Original MODAN Power Distribution Systems

Medium voltage VCP-W MR2 (integral racking)

Low Voltage Switchboards The Best Technical Solution for Your Ship

ELEKTROTEHNI KO PODJETJE Leskoπkova cesta 12, 1000 Ljubljana, SLOVENIA

LV MCC LOW VOLTAGE SWITCHGEAR MOTOR CONTROL CENTRE PRODUCT GUIDE

Masterpact NW Circuit breakers and switch-disconnectors from 800 to 6300 A

Modular Systems, PPMV, 2014 UniPack-G Glass Fiber Reinforced Polyester Compact Secondary Substation

Masterclad Medium Voltage Passive Arc-Resistant Switchgear

Takfan Machinery and Mould Co Ltd. Plug in Bushing. LV Monoblock. RMU Bushing. 4 Way CT Terminal.

Disconnectors and Earthing Switches 36 kv up to 800 kv

Submit shop drawings for equipment provided under this section Shop drawings shall indicate:

Secondary Unit Substations

FFI. Advances in Medium and Low Voltage Power Distribution ESS Metron Expo and Technical Seminars. Presented By: Greg Pelster & Robert Schmid

THE ADVANTAGES ARE YOURS

Dead Tank Circuit Breaker 72PM40-C Proven reliability through common platforms

DF-DT (G) MEDIUM VOLTAGE SWITCHGEAR THE MODULAR CONCEPT. User Manual. SGC - SwitchGear Company nv - Moorstraat 24 - B-9850 Nevele - Belgium

SWITCHGEAR Section 16. SECTION INCLUDES This Section includes service and distribution switchboards rated 600 V and less.

SIVACON Low Voltage Switchboard

GE Power Controls. MiniFORM Switchboards

SWITCHGEAR SOLUTIONS FOR MISSION CRITICAL APPLICATIONS. Presented by SAI Advanced Power Solutions

Product overview brochure. ABB Medium Voltage Products Our one-stop approach for every medium voltage application

METAL-CLAD AND METAL-ENCLOSED SWITCHGEAR 3.6KV~40.5KV. tgood.com. Energy. Fast.

SF 6 Gas Insulated Switchgear Type SDF for 170 kv

Modan 3000 ADVANCED TECHNOLOGY, INDUSTRIAL GRADE MOTOR CONTROL CENTER. Systems Products and Services. Motor Control Centers Modan 3000

Metal Enclosed Switchgears Metal Clad Switchgears Gas Insulated RMU's

Vacuum Circuit Breaker Type VAD-3

Masterclad 5 15 kv Arc Resistant Metal-Clad Indoor Switchgear

SIVACON The Versatile Low-Voltage Switchboard

Medium voltage products UniSec for Smart Grid Air-insulated medium-voltage secondary distribution switchgear

OUTDOOR DISCONNECTORS A division of ACTOM (Pty) Ltd

How To Build A Germany Power Plant

SHORE POWER. Safely Connecting Ships to Shore SAFETY QUALITY INNOVATION VALUE CUSTOMER SERVICE

Installation, Operation and Maintenance Instructions. Uniflex ABB PTMV

INTERNATIONAL POWER DISTRIBUTION CONGRESS CIDEL ARGENTINA 2002

Spending too much to maintain aging switchgear? Circuit breaker solutions from Square D Services.

Remote Monitoring and REC 501 Control Unit Product Guide

GEK-90214B. GE Lift Truck. User s Guide 144D2933G1 144D2912G1 144D2911G5

HVL 5 38 kv Load Interrupter Switchgear. The Standard for Performance, Protection and Dependability

Low Voltage Disconnect Switches. NFPA79 and UL508A Industrial Machinery Operating Handle Requirements White Paper

SPECIFICATIONS FOR TENDER NO: PSNR/SCP/VKS/E 1635 ANNEXURE I TECHNICAL SPECIFICATIONS FOR LIGHTING HIGH MAST

Siemens AG Power Transmission and Distribution Medium Voltage Division Mozartstr. 31c Erlangen Germany.

High-Voltage Circuit-Breakers 3AP1/ kv up to 550 kv. Power Transmission and Distribution

MODEL HSR-007 Direct Drive Rolling Steel

UNIVERSITY OF WASHINGTON Facilities Services Design Guide. Electrical. Switchboards. Basis of Design. Design Evaluation

Enhancing Personnel Safety with Arc Resistant Equipment

Electrical Shore Connections / Cold Ironing

Medium Voltage Distribution FLUVAC. Vacuum Circuit Breaker Up to 24 kv 630 A 21 ka. Operation Maintenance Instructions.

Safe and secure distribution of medium voltage with AX1

SUBJECT: How to wire a motor starter Number: AN-MC-004 Date Issued: 2/08/2005 Revision: Original

P System Cubicles. Certified for more safety

What will MV switchgear look like in the future? by Jean-Marc Biasse

PPS-PPQ-BT-PIAS RESIN INSULATORS FOR OIL INSULATED ELECTRICAL MACHINES

Instructions for Installation, Operation and Maintenance of 24kV Type W-VAC Vacuum Circuit Breaker

IZM ACB/Circuit-breakers. Robust safety. Extract from Main Catalogue HPL2010 IZM26 Circuit-breakers IN26 Switch-disconnectors

RENEWABLE ENERGY SUBSTATIONS SOLAR PHOTOVOLTAIC AND WIND POWER. tgood.com. Energy. Fast.

Maintenance Report MEDIUM VOLTAGE POWER STATION 500SC / 630SC / 800SC / 900SC / SC / SC / 1250SC / 1600SC / 1800SC / 2000SC

Products and solutions for lifting systems

Franco Vecchiato, SAM LPBS Regional Manager New SACE Emax 2 From Circuit-breaker to Power Manager

SENTRON Switching and Protection Devices Air Circuit Breakers

NO-FROST CUSTOMER SUPPORT INFORMATION INFORMATION ON THE NO-FROST TECHNOLOGY WHITE GOODS

TOYOTA STARTING SYSTEMS. General

Safe and reliable distribution network ABB portfolio for medium-voltage indoor applications

ABB turnkey stations ULTRA-MVC-S 770 to 3110 kw

V1504 Vertical Platform Lift OWNER S MANUAL

Hyperlinks are Inactive

WE-350 Series ¼ Turn Electric Actuator

Installation Instructions

FIRE ALARM SYSTEM. A. Shop drawings shall be submitted as follows: 1. Manufacturer's published literature. for aspproval.

Section 9: Power Distribution Equipment Bill Brown, P.E., Square D Engineering Services

Switchboard system. NorLine 800

INDOOR MEDIUM VOLTAGE SWITCHGEAR - UP TO 24kV. A division of ACTOM Pty Ltd

Permissible ambient temperature Operation Storage, transport

Dead Tank Outdoor Vacuum Circuit Breaker, Type VOX

Transcription:

EL Operating Instruction for DRIESCHER - Circuit - breaker panels EK for fixed mounting type WL withdrawable design type WEL withdrawable type in - or - compartment design EK, EK B785 EL kv ELEKTROTECHNISCHE WERKE FRITZ DRIESCHER & SÖHNE GMBH D-8566 MOOSBURG TEL. +9 87 6 6 8-0 FAX +9 87 6 68 7 http://www.driescher.com infoservice@driescher.de

Operating Instruction Withdrawable Design Type WEL All switching activities, including the traversing of the circuit breaker into disconnected position, should be carried out with the front door closed so as to ensure maximum operator safety. It will be possible within a very short period of time to withdraw the circuit breaker for service and maintenance purposes. For this, either a service truck (page ) or an auxiliary truck (page 5). Both are equipped with a docking facility and are hence stable, adjustable for height, and operator-friendly. The service truck (page ) also has a hydraulic device to lift and to lower the circuitbreaker. 5 6 7 8 9 0 Picture: Withdrawable design circuit-breaker panel Operation. The circuit-breaker can be moved into the operating position and into the connecting position either electrically by means of a control unit or manually by means of a hand crank.. For actuating the circuit-breaker (electrically or manually), the energy-storage mechanism must be charged. Immediately after the control line has been placed, the energystorage mechanism will wind up again into position.. Through the inspection window, the condition of the energy-storage mechanism 7 (charged / not charged) and the switching position 6 ( = closed / 0 = opend) can be seen.. All switching operations can be manually actuated, e.g. in case of failure of supply voltage: Picture : Withdrawable design circuit-breaker panel with open panel door It is possible to close and open the circuit-breaker with the mounted auxiliary operating device 8, but the last switching has to be an opening operation. The energy-storage mechanism can be charged by means of a hand crank on the manual winding mechanism 9. The circuit-breaker can be manually removed and inserted by means of the hand crank. The circuit-breaker can only be removed and inserted in the opened condition! 5. The position of the circuit-breaker (inserted = / removed = 0) is shown 0. 6. If desired, the earthing switch can be interlocked with the circuit-breaker and can be operated electrically or manually by means of an rotary handle.

Instructions for Use Service Truck 5 5 6 Type WEL: Circuit-breaker section, in withdrawable-unit design, with a lateral view of the service truck Withdrawal and Insertion of the Circuit-Breaker. Change-over from remote to local control.. Open circuit-breaker.. Withdrawal switchgear truck (disconnected position).. Close earthing switch. 5. Insert insulating plate 5 (not necessary in case of - or - compartment design!). 6. Open door. 7. Pull plug, and bring into position. 8. Bring up service truck (pumping motion 6 ), until insertion and docking above the interlocking device is possible. 9. Let service truck, through lowering (rotary lever 5) latch home into interlocking device. 0. Draw out switch until interlocking device on service truck latches home.. Bring up service truck (pumping motion, 6 ), and move it away.. On inserting, bring up service truck above interlocking hooks, and dock.. On lowering the service truck, it should be ensured that the interlocking hooks lock wit hin the section. If docking is carried out properly, it will be possible to insert the circuitbreaker, through releasing the interlocking device, as far as it will go into the section.. Connect control line, and latch. Immediately after the control line has been placed, the energystorage mechanism 7 will wind up again into position. 5. Close door, remove insulating plate 5, and open earthing switch. 6. Now the circuit-breaker may be put back into operation, through local or remote control.

Operating Instruction Fixed mounting Type WL All switching activities, including the traversing of the circuit breaker into disconnected position, should be carried out with the front door closed so as to ensure maximum operator safety. It will be possible within a very short period of time to withdraw the circuit breaker for service and maintenance purposes by means of an auxiliary truck. The service truck (page ) cannot be used for this type WL. The auxiliary truck is equipped with a docking facility and is hence stable, adjustable for height, and operator-friendly. 5 6 7 8 9 0 Picture : Circuit-breaker panel type WL Picture : Circuit-breaker panel type WL with open front door Operation. The circuit-breaker can be switched to ON or OFF position 0 locally (manual) or by means of remote control unit.. For actuating the circuit-breaker the energy-storage mechanism must be charged. After the connection to the voltage supply through the control line, and after each operation the energy-storage mechanism is charged through the motor drive.. Through the inspection window, the condition of the energy-storage mechanism 9 (charged / not charged) and the switching position 8 ( = closed / 0 = opend) can be seen.. The energy-storage mechanism can be charged manually by means of a hand crank on the manual winding mechanism in case of failure of supply voltage. 5. Switch disconnector 6 and earthing switch can also be operated electrically or manually by means of an actuating crank. Attention! Switch disconnector, earthing switch and circuit breaker can be interlocked all together on desire. Therefore, a faulty operation is practically impossible.

Operating Instruction for auxiliary truck Picture 5: Connection of the auxiliary truck to the interlocking 5 6 Withdrawal and Insertion of the Circuit-Breaker. Change-over from remote to local control.. Open circuit-breaker 0.. Open switch-disconnector 6.. Close earthing switch. 5. Insert insulating plate 5 (not necessary in case of - or - compartment design!). 6. Open door. 7. Pull plug, and bring into position. 8. Remove interlocking rope of the switch-disconnector at the indicated place. 9. Dock the auxiliary truck. Push the interlocking hooks into the openings until an interlocking of the levers 6 is possible through turning about 90 to the inside. 0. After removing the fixing screws 7 draw the circuit-breaker on the auxiliary truck.. Interlocking through turning the handles 6 about 90 to the outside, at the same time the circuit-breaker is fixed through the support 5 on the auxiliary truck.. Drive away auxiliary truck. Picture 6: Interlocking of the auxiliary truck to the circuit-breaker panel type WL.When inserting the circuit-breaker dock the auxiliary truck and push the interlocking hooks into the openings until an interlocking through turning of the handles 5 about 90 to the inside is possible..push circuit-breaker from the auxiliary truck into the panel and secure with fixing screws 7. 5. Connect control line, and latch. Immediately after the control line has been placed, the energystorage mechanism will wind up again into position. 6.Fix interlocking rope at the indicated place. 7.Close door, remove insulating plate 5, open earthing switch and close switch-disconnector 6. 8.Now the circuit-breaker may be put back into operation, through local or remote control. 5

Operating Instruction - or -compartment design Type EK or Type EK All switching operations as well as the moving of the circuit-breaker into the connecting position are done behind the closed front door and are only possible under certain requirements to guarantee the highest possible protection of persons. The circuit-breaker can be removed for service and maintenance purposes in a very short time. For this, either a service truck (page ) or an auxiliary truck (page 5) can be used. Both are equipped with a docking facility and are hence stable, adjustable for height, and operator-friendly. The service truck (page ) also has a hydraulic device to lift and to lower the circuit-breaker. The operation for the withdrawable design with - or -chamber compartment is except point 5 identical to type EL (page ). For type EK and EK no insulating plate is inserted, because the compartment is effected automatically through closing and opening metal shutter in front of the contacts (point 5 on page is inapplicable). 6 7 8 9 0 Picture 7: Circuit-breaker panel type EK with chamber compartment Picture 8: Open circuit-breaker panel type EK with chamber compartment without circuit-breaker 6

Operating Instruction - or -compartment design Type EK or Type EK Busbar chamber Circuit-breaker chamber Partition chamber of cable feeder Automatically opening and closing metal shutter Low-voltage compartment or secondary device module Type EK: -compartment with circuit-breaker in OFF position Type EK: -compartment with service truck, circuit-breaker in operating position Operation (for page 6, EK and EK). The circuit-breaker can be moved into the operating position and into the connecting position either electrically by means of a control unit or manually by means of a hand crank.. For actuating the circuit-breaker (electrically or manually), the energy-storage mechanism must be charged. Immediately after the control line has been placed, the energystorage mechanism will wind up again into position.. Through the inspection window, the condition of the energy-storage mechanism 7 (charged / not charged) and the switching position 6 ( = closed / 0 = opend) can be seen.. All switching operations can be manually actuated, e.g. in case of failure of supply voltage: It is possible to close and open the circuit-breaker with the mounted auxiliary operating device 8, but the last switching has to be an opening operation. The energy-storage mechanism can be charged by means of a hand crank on the manual winding mechanism 9. The circuit-breaker can be manually removed and inserted by means of the hand crank. The circuit-breaker can only be removed and inserted in the opened condition! 5. The position of the circuit-breaker (inserted = / removed = 0) is shown 0. 6. If desired, the earthing switch can be interlocked with the circuit-breaker and can be operated electrically or manually by means of an rotary handle. When removing the circuit-breaker by means of auxiliary or service truck please pay attention to pages and 5! 7

Our range of products includes: Medium-voltage systems Single-bus and duplicate-bus switchgear Non-withdrawable, withdrawable, and truck-type units Compact switchgear assemblies Customer-specific models Industrial systems Medium-voltage switchgear Indoor switches, disconnectors, and earthing switches (single and triple pole) Indoor circuit breakers (low oil content and vacuum) Outdoor switches (low oil content and vacuum) Railway switches for power supply and catenary High-voltage high-breaking-capacity fuses Customer-specific models Low-voltage systems Open-framework design Enclosed break devices (up to 6.00 A) Cable and fixed-station distribution cabinets Low-voltage switchgear Switch disconnectors Switch and fuse blocks Low-voltage high-breaking-capacity fuses Compact sub-station Concrete construction Container construction Driving gear Hand-operated and motor-operated mechanisms Indoor and outdoor driving gear Accessories For medium and low voltages For station equipment Insulators (0.5 kv - 8.5 kv) Plastic and glass-reinforced plastic screening Service Maintenance and Service of all switches and switchgears Training courses and seminars Thermography; Live-line working Dimensions, weights, diagrams and descriptions in this brochure are non-binding. Subject to change without notice. switching electricity safely Printed on chlorine free bleached paper. For nature s sake. ELEKTROTECHNISCHE WERKE FRITZ DRIESCHER & SÖHNE GMBH http://www.driescher.com infoservice@driescher.de Order No. -80085-0