F2400 FOM II Series Fiber Optic Modem Technical Manual



Similar documents
FOSTCDR. Industrial Serial to Multimode Fiber Optic Converter PRODUCT INFORMATION B&B ELECTRONICS. Specifications Serial Technology

INSTRUCTION MANUAL T1 TO RS422 INTERFACE

M7250P. PoE Powered. Gigabit Ethernet Media Converter 1000BASE-TX TO 1000BASE-SX/LX. Installation Guide

FOMi-E3, FOMi-T3 E3, T3, and HSSI Manageable Fiber Optic Modems

Perle 10/100 Ethernet Media Converters

2-Pair HDSL1 Adtran Fiber Optic Link System

RLH Single Channel T1 Fiber Link Card System

FlexPoint T1/E1 Copper to Fiber Line Driver

Perle Protocol Transparent Media Converter Modules

Perle Fast Fiber to Fiber. Media Converters

Perle Gigabit Fiber to Fiber Media Converters

SOLUTIONS FOR AN EVOLVING WORLD. T1/E1 and C Fiber Service Units

USER S MANUAL. Ethernet 10/100 Transceiver Series DL221/DL221A

Chapter 4 T1 Interface Card

USER MANUAL MODEL 2300M SERIES. OpticLink Ethernet Media Converters (2300M, 2310M, 2311M, & 2312M)

VCL-MX Version 6 DXC 80 T1, 120Mbps Digital Access Cross Connect Switch. System Guide. VCL-MX Version 6 - T1 120Mbps Voice & Data Multiplexer

Loop-V4300 MINI DACS E1/ T1 CONVERTER

Installation Guide for GigaBit Fiber Port Aggregator Tap with SFP Monitor Ports

OPT SERIAL TO FIBER OPTIC CONVERTER

T1 Backhaul Connectivity Solution All Products :: Application Note

USER GUIDE. 2 Channel POTS Mux DIN Fiber Link System. Introduction SYSTEM INSTALLATION INFORMATION. The leader in rugged fiber optic technology.

MCR1900 Media Converter 19-Slot Chassis

Megaplex-2100/2104 Modules ML-1/2E1/T1, MLF-1/2E1/T1

INTRODUCTION TO MEDIA CONVERSION

DataSMART 554 & 558 T1/FT1 Plug-in DSU/CSUs Page 1 of 8. T1/FT1 Single-port Plug-in DSU/CSUs

Loop-IP6702 TDMoEthernet

T-Extender E-Extender

USER MANUAL. MODEL 1194 Single Mode Fiber Modem With Four Fixed E1/T1 Interfaces. An ISO-9001 Certified Company

Fiber Optic Selector Guide for Analog & Digital Data Links, Contact Closures & Multiplexers

RLH 2 Wire Digital Phone Fiber Link Card System

Instruction Manual RT-94845SL RR-94845SL Forty-Eight Channel Video Multiplexer With Bi-directional Ethernet Data

Gigabit Ethernet Copper-to-Fiber Converters

Single Port Gigabit Ethernet Media Converter Board (P/N xxx) User s Manual And Troubleshooting Guide

T1 Networking Made Easy

Perle 10/100/1000 Ethernet Media Converter Module

Industrial RS-232/ RS-422/ RS-485 over Ethernet Media Converter

BLACK BOX. T1/E1 Link Extenders OCTOBER 2007 MT195A-T1 MT196A-E1

Optimux-34, Optimux-25

Advantium 2 Plus Alarm

5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual

DXC Family. Multiservice Access Node FEATURES

LTR Series Uninterruptible Power Systems 700 VA KVA. General Specification

Rack mounted telephone- and leased line modem for industrial applications

FOM-5A, 6A. Asynchronous Fiber Optic Modem

TDMoEthernet. Description

KOM200. Industrial Serial to Fiber Media Converter. User s Manual

NT1 Type 400. NT1 Type 400 Standalone L1 NT1 Type 400 Circuit Pack USER MANUAL

Operation and Installation Manual

Loop-O9310 4E1 or 4T1 Fiber Optical Mux

Optimux-134, Optimux-125

Loop-IP6700 TDMoEthernet

Optimux-45, Optimux-45L Multiplexers for 21E1/28T1 over Fiber or T3

Installation Guide for. 10/100 to Triple-speed Port Aggregator. Model TPA-CU Doc. PUBTPACUU Rev. 1, 12/08. In-Line

T1/E1 twister MAN MAN MAN. Installation & User Guide

USER MANUAL. MODEL 1082/F idsl Modem with G.703 Interface. An ISO-9001 Certified Company SALES OFFICE (301) TECHNICAL SUPPORT (301)

BIS Automation Engine

User Manual IC-485AI

Loop-IP6700 TDMoEthernet

Loop-O9310 4E1 or 4T1 Fiber Optical Mux

HARTING econ 3000 Introduction and features

Mini-HDMI Series MINIATURE MULTIMODE FIBER OPTIC HDMI TRANSMISSION SYSTEM

Optimux-134, Optimux-125

Loop-O9310 4E1 or 4T1 Fiber Optical Mux

Media Converters & Chassis

RC001-4/RC002-4 (REV.B) 4-slot rack mounted chassis User manual

TNE1500-P and TNE1500-S Single Line T1 Network Extender Provider and Subscriber

Setting Up and Testing the MAX Hardware

24-Port Channelized E1/T1 Line Card Overview

LDG DTS-4/4R Desktop Coaxial Switch / Remote

EM316T1E1-XY. Features

RICi-E1, RICi-T1 Fast Ethernet over E1/T1 Intelligent Converters

FIBER OPTIC APPLICATION IN A PROFIBUS NETWORK

Media Converters & Chassis

ECR Shelf System Installation Guide Centralized Rack Mount Call Recording

Cable Specifications. T3 Trunk Cabling APPENDIX

ABB RTU560A Series CMU & Modules

Cisco T1 Layer 1 Troubleshooting

DigiPoints Volume 1. Student Workbook. Module 4 Bandwidth Management

Westell IDR9186SB Intelligent High-Density T1 Office Repeater

EZmoto V2. Product description Rev. 6 10/01/2014. EZmoto V2 Product description Rev.6 10/01/2014

User Guide. HDMI Active Cable Extender. DVI-7370c

TCP/IP MODULE CA-ETHR-A INSTALLATION MANUAL

NC-12 Modbus Application

CNC File Transfer Box. Connecting the CNC File Transfer. CNC Transfer Program

WaveReady CFM. Optical Link Monitoring System: Continuous Fiber Monitor

MODEL 5010 DUAL CHANNEL SMOKE/FIRE DETECTION MODULE

Serial Media Converters

T-BERD 107A. T-Carrier Analyzer

BLACK BOX Scalable matrix KVM switch supports up to 1024 ports with fiber or copper cable.

Total Access SHDSL T1/E1 Line Terminating Unit Installation and Maintenance Practice

SECTION VIDEO SURVEILLANCE SYSTEMS INFRASTRUCTURE

MICROSENS Media Converter 10/100/1000T to Gigabit Fiber

ENET-710. ENET Ethernet Module ENET-710 JAN / 06 FOUNDATION

Gigabit Switching Ethernet Media Converters - Product User Guide

Stand Alone POTS Fiber Optic System. P31372 Station (Subscriber) Unit P31379 Remote (Exchanger) Unit. Description & Installation

TrueAlarm Fire Alarm Systems

2X1 DVI Switch (DS-21R) 4X1 DVI Switch (DS-41R) USER MANUAL. DTronics Inc.

TCB-2 Auto Answer Coupler Product Manual

8-port 10/100Base-TX +2-port 100Base-FX Switch. User s Guide

Transcription:

F2400 FOM II Series Fiber Optic Modem Technical Manual T1 Revision B Copyright April 2003 VERSITRON, Inc. 83 Albe Drive / Suite C Newark, DE 19702 www.versitron.com A030430283T

PROPRIETARY DATA All data in this manual is proprietary and may not be disclosed, used or duplicated, for procurement or manufacturing purposes, without prior written permission by VERSITRON, Inc. WARRANTY All VERSITRON products purchased after January 2001 are warranted against defects in materials and workmanship for the lifetime of the product. Purchases made prior to January 2001 are warranted for a period of one year from date of delivery. VERSITRON reserves the right to repair or, at our option, replace parts which during normal usage prove to be defective during the warranty period provided that: 1. You call VERSITRON at 302-894-0699 or 800-537-2296 and obtain a Return Maintenance Authorization (RMA) Number. Please reference your RMA number on the outside of the shipping box. 2. Shipping charges are pre-paid. No other warranty is expressed or implied and we are not liable for consequential damages. For repairs outside of the warranty period, the same procedure must be followed. ii www.versitron.com

TABLE OF CONTENTS PARAGRAPH TITLE PAGE SECTION 1: DESCRIPTION OF EQUIPMENT 1.1 INTRODUCTION...1 1.2 DESCRIPTION OF EQUIPMENT...1 1.2.1 Functional Characteristics...1 1.2.2 Physical Characteristics...1 1.3 SPECIFICATIONS...3 SECTION 2: INSTALLATION 2.1 GENERAL...4 2.2 SITE SELECTION AND MOUNTING...4 2.3 POWER REQUIREMENTS...4 2.4 SWITCH SETTINGS...4 2.5 OUTPUT CONNECTIONS...6 2.6 LOOPBACK...6 2.6.1 Fiber/Copper Loopback...6 2.6.2 Interface Loopback...6 2.7 INITIAL CHECKOUT PROCEDURE...7 SECTION 3: OPERATION 3.1 INTRODUCTION...8 3.2 STATUS INDICATORS AND ALARM CIRCUITS...8 3.3 OPERATING CONTROLS...8 SECTION 4: THEORY OF OPERATION 4.1 INTRODUCTION...9 SECTION 5: MAINTENANCE AND TROUBLESHOOTING 5.1 INTRODUCTION...10 5.2 FAULT ISOLATION...10 iii www.versitron.com

LIST OF ILLUSTRATIONS FIGURE TITLE PAGE 1. OVERALL VIEW, F2400 FIBER OPTIC MODEM...2 2. MODEL F2400 CIRCUIT DETAIL SHOWING SWITCH LOCATIONS...5 LIST OF TABLES TABLE TITLE PAGE 1. ENCLOSURES / CHASSIS...2 2. SWITCH SETTINGS...5 3. SWITCH SETTINGS VS. COPPER INTERFACE CABLE LENGTH...6 4. NON-OPERATIONAL INDICATORS...10 iv www.versitron.com

SECTION 1 DESCRIPTION OF EQUIPMENT 1.1 INTRODUCTION This manual provides information on the installation and operation of the Model F2400 FOM II Series T1 Fiber Optic Modem. Section 1 contains a general description of the equipment. Section 2 contains installation instructions. Section 3 contains operating instructions. Section 4 provides the theory of operation. Section 5 contains maintenance and troubleshooting information. Model Part Number Number Description F2402 30283-02 T1 fiber modem, duplex or simplex, 850nm MM LED, ST, 3km F2404 30283-04 T1 fiber modem, duplex or simplex, 1300nm MM LED, ST, 15km F2405 30283-05 T1 fiber modem, duplex or simplex, 1300nm SM LED, ST, 30km 1.2 DESCRIPTION OF EQUIPMENT 1.2.1 Functional Characteristics F2400 modems operate as point-to-point converters for copper-to-fiber T1-standard interface extenders. F2400 modems transmit over fiber optic cable up to 3km (1.85mi/9,800ft) with multimode 850nm LEDs, up to 15km (9.3mi/49,000ft) for multimode 1300nm LEDs or up to 30km (18.5mi/98,000ft) for single mode 1300nm LEDs. The fiber optic circuit (two F2400 modems connected by fiber cable) has data rates and electrical signal characteristics that conform to ANSI T1.403, AT&T Pub. TR54016 and TR62411 standards. Electrical signals on copper cable are converted to fiber optic signals by the F2400 modem, and AMI or B8ZS data protocols are decoded. 1.2.2 Physical Characteristics F2400 modems measure 7.0W x 0.84H x 11.6L in. (17.8 x 21. X 28.9 cm) and are designed for mounting in a variety of VERSITRON enclosures. Table 1 lists dimensions of enclosures and chassis. Standalone options include single card enclosures (HF-1) and dual card enclosures (HF-2). 19 rack mount options include 2-slot chassis (HF-2SS) and 20-slot chassis (HF-20). Each F2400 modem installed in a HF-1, HF-2 or HF-2SS requires a power adapter Model PSAC08 (US) or PSAC09 (European) providing 12 VDC, 1A with a one-pin connector for electrical input on the back of the card. There is a female DB15 connector for the digital interface and two ST connectors for the fiber optic interface, also on the back of the card. F2400 modems installed in a HF-20 require a Model AC150W Power Supply / System Monitor. Each AC150W installed into the chassis requires two slots. Two AC150W supplies are recommended for power redundancy. F2400 Modems have six LED indicators on the front panel: power on (PWR), alarm (ALM), transmit data present (TXD), receive data present (RXD), bipolar violation (BPV), and loopback mode indicator (LOOP). No audible alarm is available. 1 www.versitron.com

FIGURE 1. OVERALL VIEW, F2400 FIBER OPTIC MODEMS Model # (Part #) HF-1 (19052) HF-2 *² (19053) HF-2SS *² (19629) HF-20 (19032) Dimensions Description Power Supply Required*¹ 7.1" W x 1.3" H x 11.6" L Single Card Standalone Enclosure 7.1" W x 2.3" H x 11.6" L Dual Card Standalone Enclosure 19" W x 1.7" H x 13.8" L 2-Slot Rack Mount Chassis 19" W x 7.1" H x 11.6" L 20-Slot Rack Mount Chassis *¹ Note: US Model - PSAC08; European Model - PSAC09 *² Note: One Power Supply per Modem required. TABLE 1. ENCLOSURES / CHASSIS PSAC08 PSAC09 (LTWPD1210PLX) (LTWPD1210EPL) PSAC08 PSAC09 (LTWPD1210PLX) (LTWPD1210EPL) PSAC08 PSAC09 (LTWPD1210PLX) (LTWPD1210EPL) AC150W (19320-03) 2 www.versitron.com

1.3 SPECIFICATIONS Protocol: Synchronous Data Rate: (N x 64 Kbps) 1.544 Mbps. Operation: Full duplex or simplex. Optical Interface: ST connectors. Digital Interface: Signal levels conform to ANSI T1.403, AT&T Pub. TR54016 and TR62411 standards. Electrical Interface: Female DB15. Dimensions: 7.0" wide x 0.84" high x 11.6" deep (17.8 x 2.1 x 28.9 cm). Weight: 16.0 oz. (0.45 kg). Power Requirements: 120 VAC, 1.4 Watts, with optional DC wall transformer (VERSITRON Model PSAC08, providing 12 VDC, 1 A, US; VERSITRON Model PSAC09, European). Environment: 0 to +50 C (32 to +122 F) operating temperature; up to 95% relative humidity (noncondensing); up to 10,000 feet altitude; storage temperature -40 to +70 C. Model F2402 F2404 F2405 Wavelength Multimode 850nm Multimode 1300nm Single Mode 1300nm Link Budget* 26 ± 1 db 29 ± 1 db 30 ± 1 db Operating Range 3km / 1.85mi / 9,800ft 15km / 9.3mi / 49,000ft 30km / 18.5mi / 98,000ft Fiber Optic Cable 50/125,62.5/125,100/140 50/125, 62.5/125, 100/140 8/125, 9/125,10/125 *Note: Multimode tests were performed on 62.5/125 µm fiber optic cable. Single Mode tests were performed on 10/125 µm fiber optic cable. Format ESF D4 (Extended Super Frame) (Super Frame) AMI Yes Yes B8ZS Yes Yes 3 www.versitron.com

SECTION 2 INSTALLATION 2.1 GENERAL This section contains detailed information on the installation and initial checkout of the F2400 modems. Paragraph 2.2 contains general information on site selection and rack mounting. Paragraphs 2.3 through 2.6 contain detailed instructions for connecting the modems to your system and selecting the different options. Paragraph 2.7 contains initial checkout procedures. 2.2 SITE SELECTION AND MOUNTING F2400 modems are designed to connect directly to the serial port (DB15F Connector) of PBX or multiplexer equipment with a cable (customer supplied). Mounting options include standalone single card (HF- 1) or dual card (HF-2) enclosures and 2-slot (HF-2SS) or 20-slot (HF-20) rack mount chassis. 2.3 POWER REQUIREMENTS F2400 modems operate from an AC power source or a DC power source with a DC voltage of +12 VDC, 1A. The power supplies used when installed in a HF-1, HF-2, or HF-2SS are VERSITRON Model PSAC08 (US) or Model PSAC09 (European) providing 12 VDC, 1A. Connect the power transformer to the F2400 unit before inserting its plug into an AC power source. No special tools are required. DC power may be used instead of an AC transformer, if available. This requires a 2.5 mm socket with positive on the center and common on the concentric, and providing +12 VDC at 1A When installed in a HF-20, the AC150W Power Supply / System Monitor is used to supply power for all FOM II series circuit cards installed into the chassis. The AC150W requires two slots in a HF-20. For power redundancy, two AC150W units are recommended. 2.4 SWITCH SETTINGS F2400 modems have one 8-position switch onboard the circuit card. This switch is located near the DB15 connector, as shown in Figure 2. The switch is labeled "SW3" on the circuit card, and is positioned such that the "ON" setting of each of the 8 switch positions is towards the front panel of the circuit card. The settings of the 8 switch positions are as specified in Tables 2 and 3. Position 1 on the switch, RCODE, is used to set the protocol for the data received on the T1 link. Position 8, TCODE, likewise is used to set the protocol for the data transmitted on the T1 link. Both of these may be set for AMI or B8ZS protocols. These switches must be set properly prior to operation, and if the encoder or decoder settings do not agree with the input data, the unit may not function properly. Two loopback settings may be changed using switch positions 6 and 7. Position 6, RLOOP, allows for loopback of the copper interface, and Position 7, LLOOP, permits the loopback of the fiber interface. The local loopback is controlled from the front panel of the F2400 while in operation. Position 2 is not used, and Positions 3-5 are set on the basis of the cable length of the copper interface. 4 www.versitron.com

R13 R6 R14 Q1 R23 C3 U4 RX R15 Q4 U5 C7 C11 TX R16 Q5 C8 C2 C1 Y1 1 J5 C4 R17 Q6 VR1 1 U2 1 F1 P1 TP7 TP8 TP9 TP10 C14 R3 R1 C5 S Q2 D R5 R22 Q3 R18 SW1 JP1 P D C10 TP1 R8 TP2 TP3 TP4 TP5 R7 TP6 JP3 JP2 R11 R21 R12 Y2 U1 U3 R2 C9 C12 R10 JP4 R9 C15 C6 RN1 1 ON R4 SW3 8 7 6 5 4 3 2 1 GND F2 F3 FGND CR1 R20 1 9 R19 J3 J4 8 15 VERSITRON MADE IN USA L1 C13 JP6 T1 T2 JP5 SW3 O N 1 2 3 4 5 6 7 8 O F F FIGURE 2. CIRCUIT DETAIL SHOWING SWITCH LOCATION SWITCH 3 NAME FUNCTION ON FUNCTION OFF POSITION 1 RCODE AMI B8ZS POSITION 2 NOT USED N/A N/A POSITION 3 LEN 0 POSITION 4 LEN 1 Cable Length Settings: See Table 3. POSITION 5 LEN 2 POSITION 6 RLOOP Remote Loop ON Remote Loop OFF POSITION 7 LLOOP Local Loop ON Local Loop OFF POSITION 8 TCODE AMI B8ZS 2.4 SWITCH SETTINGS (Cont.) TABLE 2. SWITCH SETTINGS Positions 3, 4 and 5 of the switch are set based on the length of cable used for the copper interface to the F2400 modem. As shown in Table 3, the modem may be configured to handle cable lengths up to 655 feet. The five-partition selection meets T1 DSX-1 cross-connect standards ANSI T1.102 and AT&T CB-119 requirements when using #22 ABAM cable. Two additional options are available for T1 Network Interface applications. There are six jumpers on the F2400. None of the other jumpers should be changed from the positions set in the factory. They are used for test and diagnostic purposes only and are not to be reset by the user. 5 www.versitron.com

POSITION 3 (LEN 0) POSITION 4 (LEN 1) POSITION 5 (LEN 2) CABLE LENGTH ON ON OFF < 133 FT OFF OFF ON 133-266 FT ON OFF ON 266-399 FT OFF ON ON 399-533 FT ON ON ON 533-655 FT OFF ON OFF FCC PART 68 ON ON OFF ECSAT1C1.2 APPLICATION DSX-1 ABAM (AT&T 600B OR 600C) NETWORK INTERFACE TABLE 3. SWITCH SETTINGS VS. COPPER INTERFACE CABLE LENGTH 2.5 OUTPUT CONNECTIONS F2400 modems use a standard 15-pin D sub miniature connector (female) for the electrical signal interface. Only four of the pins are used, however. Receive data is input on Pins 1 and 9 and transmit data is output on Pins 3 and 11. 2.6 LOOPBACK F2400 modems have two loopback features. The first Loopback feature allows the user to test the fiber optic circuitry of the local unit, the fiber optic circuitry of the remote unit, the copper circuitry of the local unit, and the copper circuitry of the remote unit. The second Loopback feature loops the interface circuitry only. 2.6.1 Fiber/Copper Loopback The fiber optic inputs and outputs of the F2400 modems are connected to a multiplexer. When the front panel loopback switch (LB) is switched ON, the multiplexer control bit is set high and fiber optic input data is looped to the output and back to the source. The copper signals entering through the interface circuitry are encoded and decoded by the multiplexer and likewise looped back to their source. If both the fiber and copper input and output signals match, then the optical and interface circuitry of both units is operating properly. 2.6.2 Interface Loopback As listed in Table 2, RLOOP and LLOOP, switch positions 6 and 7, are used to loop the bipolar data signals at the interface. This allows for testing of the copper and fiber inputs and outputs between connected devices without going through the copper-to-fiber conversion circuitry. 6 www.versitron.com

2.7 INITIAL CHECKOUT PROCEDURE F2400 modems contain no power on/off switch. Once the unit is properly installed and power is applied it is considered fully operational. The power indicator (PWR) should remain on as long as power is supplied to the unit. Upon initial power up, with no signal connections made, the PWR, alarm (ALM) and bipolar violation (BPV) LED indicators should be on. When signal connections are properly made, the transmit data (TXD) and receive data (RXD) LED indicators should be on and the ALM and BPV LEDs should go off. Before beginning system operation the following items should be checked to verify proper installation: 1. Verify that the power plug is seated fully into the F2400 or seated firmly in the rack mount enclosure. 2. Verify that the fiber optic cable is crossed transmit to receive from unit one to unit two. 3. Verify that the ALM and BPV LEDs go out when the signals are applied to the F2400. 4. Verify that the LOOP LED comes on and goes out with the LB switch on the front panel. 5. Verify the switch settings are correct for the circuit configuration. If a malfunction is detected during the initial checkout procedure, refer to Chapter 5 for information on isolating the malfunction in the unit. 7 www.versitron.com

SECTION 3 OPERATION 3.1 INTRODUCTION This chapter contains a description of the operating controls and indicators associated with the F2400 modems. Since the modem is designed for continuous and uninterrupted operation, there are no operating requirements. Once powered up, it should remain in service as long as required. 3.2 STATUS INDICATORS AND ALARM CIRCUITS There are six LED indicators on the F2400: power (PWR), alarm (ALM), transmit data (TXD), receive data (RXD), bipolar violation (BPV), and loopback (LOOP). No audible alarm is available. The F2400 modems contain a standard FOM II alarm circuit to monitor the optical connection and power supplies. The ALM LED is activated when no signal is present at the fiber optic interface. When AMI signals are decoded, bipolar violation circuitry checks the signal. The BPV LED is activated when a violation is detected and remains on until turned off by the RESET switch on the front panel. 3.3 OPERATING CONTROLS The only operating controls associated with the F2400 modems are two front panel switches. The LB switch is used to enable the loopback capability of the circuit. This is described in Section 2.6 and is normally only used for diagnostic purposes when initializing or reconfiguring the system using the F2400. The reset pushbutton switch is only used if a bipolar violation occurs. The switch settings onboard the circuit card are described in Tables 2 and 3 in Section 2.4 and are set prior to first using the modem. Further changes are not required unless the system requirements change. 8 www.versitron.com

SECTION 4 THEORY OF OPERATION 4.1 INTRODUCTION F2400 modems provide a transparent, synchronous path for T1-standard signals. By converting to fiber optic signaling, a distance of 3km (1.85mi/9,800ft) for 850nm multimode LEDs, 15km (9.3mi/49,000ft) for 1300nm multimode LEDs, or 30km (18.5mi/98,000ft) for 1300nm single mode LEDs may be traversed without the need for a repeater or amplifier. In addition, the use of fiber optic cable as the transmission medium provides EMI/RFI protection and data security. In the F2400 transmitter circuitry, the data is received via Pins 1 and 9 of the DB15 connector. The signal is decoded for AMI or B8ZS protocol, and then Manchester encoded (which embeds a clock signal) with a Field Programmable Gate Array (FPGA). Next the signal is converted into an optical signal. The optical signal transmitter then sends the signal out onto the fiber optic cable. Through the receiver circuitry of the F2400 the same process occurs in reverse. First the optical signal is received and converted back to an electrical signal. The FPGA decodes the Manchester data and clock signals. The data signal is then encoded for the AMI or B8ZS protocol and output to Pins 3 and 11 of the DB15 electrical signal interface. To the multiplexer or PBX terminal equipment connected to the F2400 pair, the transition from copper to fiber and back is transparent. 9 www.versitron.com

SECTION 5 MAINTENANCE AND TROUBLESHOOTING 5.1 INTRODUCTION This chapter contains general information designed to isolate a malfunction in the F2400 modems to a replaceable unit. These units are not equipped with redundancy. Therefore, a failure in one of these units would interrupt service. 5.2 FAULT ISOLATION The steps in Table 4 should be taken to check a non-operating modem. Contact VERSITRON Customer Service for additional diagnostic assistance or to arrange for repair as necessary. STATUS INDICATOR PROBABLE CAUSE CORRECTIVE ACTION POWER (PWR) LED is off. ALARM (ALM) LED is on. DATA (TXD, RXD) LEDs are off or not responding as expected. BPV LED continuously on. No AC power. Blown Fuse. Other power supply circuit problem. Incorrect optical signal level received at receiver input. Switches in wrong position. No input on the electrical interface connector. Switches in wrong position. Inverted input on the electrical interface connector. Check that both ends of the Transformer are connected. Replace with 800 ma, 5 x 20 mm Slo-Blo fuse. Contact VERSITRON Customer Service for assistance. 1. Check that fiber optic cable is properly connected to RX connector. 2. Check that the remote unit power is on and the RX fiber on one end is connected to the TX fiber on the other end. 3. Measure the optical levels on both ends (if possible) in order to check the optical link. 4. Contact VERSITRON Customer Service for assistance. Check that the switch is set for the correct electrical interface protocol. Check that the interface connector is connected securely. Check that the switch is set for the correct AMI or B8ZS protocol. Check that the interface connector is wired correctly. TABLE 4. NON-OPERATIONAL INDICATORS 10 www.versitron.com