BT300 HVAC Drives Conventional Bypass (C-Bypass) Options

Similar documents
BT300 HVAC Drives Conventional Bypass (C-Bypass) Options

CONSTRUCTION STANDARDS DIVISION 23 HEATING VENTILATING AND AIR CONDITIONING

The HVAC SOLUTION DELIVERING POWER...SAVING ENERGY

32VFD Variable Frequency Drives for Centrifugal Chillers

VARIABLE FREQUENCY DRIVES Revised 4/30/ Mechanical Systems

SUBJECT: How to wire a motor starter Number: AN-MC-004 Date Issued: 2/08/2005 Revision: Original

Bulletin 150 Smart Motor Controllers SMC-3 Smart Motor Controller

PowerFlex 700 and 700H Packaged Drives. Technical Data

SECTION VARIABLE FREQUENCY DRIVES

Number 1 in efficiency

vacon 100 hvac premium ac drive for indoor climate control

HVAC DRIVE H300 HVAC Drive for Building Automation

CAT ATC POWER BREAKER & POWER CASE SWITCH AUTOMATIC TRANSFER SWITCH

vacon 100 hvac for indoor climate control

SmartVFD Frame 4 Wiring Diagrams and Dimensional Drawings

How To Use The Vacon 0 Machinery

Re-defining the utility-scale inverter

2011 Industrial Catalog. DRIVES, PAC, PLCs. Industrial Catalog

MTE SERIES RLW. World REACTORS USER MANUAL PART NO. INSTR 030 REL MTE Corporation

SmartVFD HVAC and BYPASS

LTR Series Uninterruptible Power Systems 700 VA KVA. General Specification

Contents. Clean Control Center Harmonic Correction Unit. Selection Dimensions Specifications. Description

HVAC03C2 HVAC61C2 HVAC03C5 HVAC61C5 NXL HVAC INVERTERS

GTEC transfer switch open transition

Product Bulletin. ABB drives for HVAC applications ACH550, 1 to 550 Hp

Limited Service Fire Pump Controllers Features

Product Description Full Voltage Starting Electric Fire Pump Controllers FTA1000

XFE. The cost effective starter for all AC induction motors from 4A 2800A The choice for small to medium industrial applications

Z1000 HVAC Drive. 3 HP to 500 HP Fan and Pump Applications. Specifications

Permissible ambient temperature Operation Storage, transport

Electronic overload relay EF65, EF96 and EF146

Electric Vehicle Charging Station Products EVoReel Charge Cable Management Solutions

Vilter motor starter solutions The NEW industry standard in motor starter packages

vacon x series rugged drives for the real world

ABB general machinery drives. User s manual ACS355 drives

Easy Multifunctional Safe

Variable speed drives

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

MCC Ratings. Voltage Rating

How To Operate A Gec Transfer Switch Open Transition Amp Power Supply

Variable Speed Drives

SED2 Variable Frequency Drives Startup, Operation, and Maintenance Manual

Thyristor-controlled power supplies and battery chargers

THERMAL MANAGEMENT SOLUTIONS

Products and solutions for lifting systems

Bussmann. All-In-One Module. Bussmann Power Module Switch. How to configure Part Numbers: Step 1: Select Switch Amperage 1

Variable Speed Drives

Electronic overload relay EF19 and EF45

Catalog January. Heavy industrial power applications Motor contactors and starters

Bimetallic Overload Relay Specifications

ACH550 BCR/BDR/VCR/VDR E-Clipse Bypass Drives. User s Manual. ACH550 E-Clipse Bypass User s Manual 2-1

Eaton s E-Series protective relay family

PSR The compact range Description

AuCom s IMS2 soft starters are a total motor starting solution, combining highlevel functionality with ease of use:

Manual motor starter MS116

Bulletin 150 SMC Flex Smart Motor Controller Specifications

REVIEWED BY CAPITAL PROJECTS MANAGER (DAN REDDY) GENERAL MANAGER EQUIPMENT ENGINEERING & ASSET MANAGEMENT (HAMILTON NXUMALO)

Product Description Primary Resistance Starting Electric Fire Pump Controllers FTA1500

CENTERLINE Motor Control Centers Bulletin 2100 Smoke Detector Unit

Application/Connection Examples

Specifying a Variable Frequency Drive s

Medium Voltage Motor Control Assemblies

Arc Terminator Active Arc-Resistant Switchgear

650W Single Output Power Supply 15V 24V. 27V 48V Rated Current. 0 ~ 100A 0 ~ 50A 0 ~ 40A 0 ~ 27A 0 ~ 24A 0 ~ 13.6A Rated Power

Power Supplies 3. SDN-P DIN Rail Series

Automatic Transfer Switch Controller

MICROSENS. Central 48 V DC Power Supplies for PoE-Components. Description. Features

ABB machinery drives. User s manual ACS355 drives

Industrial Tower Uninterruptible Power Supply Specifications Bulletin Numbers 1609-P

MAJORSINE Power Inverter

Fractional to 2 HP DC Drives for Both Non-Regenerative and Regenerative Applications

1000W Single Output Power Supply 15V 24V. Protection type: Total Power limit, Latch-style (Recovery after reset AC power ON or inhibit)

MC Series Drives. Flexible, simple, rugged, robust! Phone: Fax: Web: info@actechdrives.

WYE-DELTA AND SOLID STATE STARTER APPLICATION GUIDE

Product Description Digital Solid State Starting Electric Fire Pump Controllers FTA1930

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC A - M8 connector

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

Uninterruptible Power Supply

Product Description Full Voltage Starting Electric Fire Pump Controllers FTA1000

8146/5 Series Breaker Panelboards

Model: DC-A2IO Advanced HVAC Controller

TR1 Series VFD. Variable Frequency Drives TR1-SLB005-EN

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

ABB low voltage drives ACS550, Hp Technical Catalog

Electronic Control Devices The European Product Catalogue 2007

Diesel Engine Driven Generators Page 1 of 6

SmartOnline V 5kVA 4.5kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 4U Rack/Tower, USB, DB9 Serial

NetScanner System. Toronto: , Montreal: , Toll Free: ,

Technical Instructions Document No P25 ET September 28, ET 141 High Limit Control Thermostat. Description.

SECTION STATIC UNINTERRUPTIBLE POWER SUPPLY SYSTEM

Square D Model 6 Motor Control Centers

Transfer switch BTPC open, closed or delayed transition

Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2

Circuit Breakers. Next Generation of Protection Capabilities

Electronic Control Devices The European Product Catalogue 2007

Products and solutions for pumping, irrigation and piping

PRODUCT GUIDE. SL Medium Voltage IEC Vacuum Contactors

LC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A V AC coil

ISIO 200. Binary Input/Output (I/O) Terminal with IEC Interface

Arc Flash Avoidance and its Application to Overhead Traveling Cranes

Transcription:

BT300 HVAC Drives Conventional Bypass (C-Bypass) Options Description The BT300 Conventional Bypass is a companion package for the family of BT300 HVAC Drives. For information on the family of BT300 HVAC Drives, see the BT300 HVAC Drives Submittal Sheet (154-126) and BT300 HVAC Drives Technical Specification Sheet (149-711). BT300 C-Bypass Features Bypass Start-up Wizard Diagnostic board with test points Control logic short circuit protection 100,000 AIC short circuit rating Country of Origin (COO) USA IBC 2012 Seismic Certified Compact design Bypass Power Features 2-Contactor: Output and Bypass Overload protection in bypass mode Electrically and mechanically interlocked Drive Isolation Drive Service Switch allows the drive to be disconnected from power during troubleshooting without disrupting bypass operation. Optional 3-Contactor (Drive Input) Contactors electrically interlocked. Drive test function Complete electrical isolation of drive Input Device Fused disconnect Circuit breaker (optional) All doors are interlocked and can be secured with a padlock. 5% Input Impedance Internal reactors lower harmonics that the drive produces. BT300 C-Bypass requires no additional input reactors Reactor Options Line reactor (in NEMA 1 enclosure) supplied separately. Load reactor (in NEMA 1 enclosure) supplied separately. Bypass Control Features Enable Input Generally used for safety tie-ins; the motor will not operate the drive or bypass when open. Common Remote Start/Stop Common remote start/stop can be used in both drive and bypass mode. Essential Services Mode Typically used for smoke purge; the motor goes to bypass regardless of the selected mode. No call to stop will have an effect, including open safety or stop commands. Only turning the power off or opening this contact will stop the motor. Bypass Door Mounted Control Devices Drive-Off-Bypass selector Bypass pilot light Drive Test on/off selector (with third Contactor)

BT300 HVAC Drives With C-Bypass Options Product Numbers Example Product Numbers B T E - 0 0 1 X 2 - F 0 1 2 B T C - 0 0 7 5 4 - B 0 1 3 L Bypass Models BTC Conventional BTE Electronic HP 1,1.5, 2, 3, 5, 7.5, 10, 15 20, 25, 30, 40, 50, 60,75 NOTE: 208V only up to 40 HP X=no fract HP, 5=1/2 HP Voltage 2 208 to 240 4 380 to 480 Disconnect F Fused Disconnect B Circuit Breaker NEMA 01 UL Type 1 Type 3 3 contactors (input, output and bypass) (for C Bypass only) 2 2 contactors (output, bypass) w/ service switch Options L Lon card installed NOTE: Table 1. NEMA 1 C-Bypass Approximate Weights. Frame Weight lb (kg) FS4 50 (23) FS5 69 (31) FS6 112 (51) FS7 187 (85) Exact weight will be affected by actual horsepower/voltage and selected power options. Typical Specifications BT300 Bypass Options shall send the motor to bypass mode based on an easily accessible door-mounted selector or based on the drive s programmable relay. A bypass pilot light shall provide indication of the bypass mode. The bypass mode shall provide overload protection. Contactors shall be electrically and mechanically interlocked. An essential services mode shall send the motor to bypass regardless of the selected mode. Table 2. C-Bypass Frame Sizes and Power Ranges per NEC Motor Tables. Current Ratings Frame Size HP kw 208 230 480 208 230 480 1 0.75 4.6 4.2 N/A N/A 1.5 1.1 6.6 6 3 2 1.5 7.5 6.8 3.4 FS4 3 2.2 10.6 9.6 4.8 FS4 5 4 16.7 15.2 7.6 7.5 5.5 24.2 22 11 FS5 10 7.5 30.8 28 14 15 11 46.2 42 21 FS5 FS6 20 15 59.4 54 27 25 18.5 74.8 68 34 30 22 88 80 40 FS7 FS6 40 30 114 104 52 50 37 65 60 45 N/A 77 N/A FS7 75 55 96 NOTE: Drives are current (amperage) rated devices. Verify that the listed ratings are > the motor full load current rating. Page 2 of 8

BT300 HVAC Drives With C-Bypass Options Submittal Sheet Dimensions Figure 1. NEMA 1 C-Bypass Dimensions in Inches (cm). Page 3 of 8

BT300 HVAC Drives With C-Bypass Options Wiring Diagrams Figure 2. C-Bypass Control Logic. Page 4 of 8

BT300 HVAC Drives With C-Bypass Options Submittal Sheet Wiring Diagrams, Continued Figure 3. Power Wiring. Page 5 of 8

BT300 HVAC Drives With C-Bypass Options Wiring Diagrams, Continued Figure 4. C-Bypass Controller Board Digital Inputs and Outputs. Page 6 of 8

BT300 HVAC Drives With C-Bypass Options Submittal Sheet Specifications Table 3. C-Bypass Specifications. Description Input Voltage (3-phase) 208V, 3 AC±10%. 1 hp to 40 hp (3.9 amps to 105 amps) 480V, 3 AC ±10%. 1 hp to 75 hp (2.1 amps to 105 amps) Standard Bypass I/O Analog Inputs Analog Output 2: Voltage or current (up to 10 Vdc, 0/4 to 20 ma) 1: Selectable voltage or current Digital Inputs All Digital Inputs are fully programmable. Defaults are configured as follows: Remote start input Remote safety 1 Essential services Overload trigger Relay/Digital Outputs Inputs require a contact closure capable of providing a low impedance path at currents less than 20 ma. All Relay/Digital Outputs are fully programmable. Defaults are configured as follows: VFD fault Programmable output Drive Run Bypass select Each relay has a maximum rating of 2A at 120 Vac. Short Circuit Withstand Rating 100,000 AIC Temperature Ambient Operating:14 F (-10 C) no frost to 104 F (40 C) without de-rating and 131 F (55 C) with de-rating Storage: 40 F to 158 F ( 40 C to 70 C) Relative Humidity 0 to 95% RHJ, non-condensing, non-corrosive Air Quality Chemical Vapors Mechanical Particles IEC 60068-2-60 IEC 60721-3-3, unit in operation, class 3C3 IEC 60721-3-3, unit in operation, class 3S2 Altitude 100% load capacity (no de-rating) up to 3,280 ft (1,000 m) 1% de-rating for each 328 ft (100 m) above 3,28 ft (1,000 m) Maximum altitude 14,763 ft (4,500 m) Vibration IEC 61800-5-1 and IEC 60068-2-6 Seismic 2012 International Building Code (IBC) Shock IEC 61800-5-1 and IEC 60068-2-27 Enclosure UL Type 1 Agency Approvals UL 508C Auxiliary Input Voltage 24 Vdc Auxiliary Output Voltage Serial Interface Embedded Resident Protocols Protection features 24 Vdc at 50 ma maximum RS485 and Ethernet Modbus RTU, Modbus TCP: BACnet MSTP, BACnet IP; N2 All in either Drive or Electronic Bypass Under-voltage trip limit, Over-voltage trip limit, Ground fault protection, Mains supervision; Motor phase supervision; Over-current protection; Unit over-temperature protection; Motor overload protection; Motor stall protection; Motor underload protection; Short-circuit protection of +24V and +10V reference voltages. Page 7 of 8

BT300 HVAC Drives With C-Bypass Options Table 4. Order Worksheet. Item Qty. Designation Part Number Description Information in this publication is based on current specifications. The company reserves the right to make changes in specifications and models as design improvements are introduced. Product or company names mentioned herein may be the trademarks of their respective owners. 2014 Building Technologies Division 1000 Deerfield Parkway Buffalo Grove, IL 60089 USA + 1 847-215-1000 www.buildingtechnologies.siemens.com/bt/us Your feedback is important to us. If you have comments about this document, please send them to sbt_technical.editor.us.sbt@siemens.com. Printed in the USA Page 8 of 8