REVERSE OSMOSIS WATER TREATMENT

Similar documents
AQUAPRO INDUSTRIAL CO.,LTD. Reverse Osmosis Parts Introduction

Water Treatment and Reverse Osmosis Systems

Electrodeionization (EDI)

Medical Air Systems: Scroll

4 Stage Barracuda RO/DI Instruction & Owner s Manual

Thermo Scientific Barnstead TII Pure Water Systems. Pure water. Pure research. Total confidence.

RO Reverse Osmosis equipments

Wastewater Reuse. Typical treated wastewater is:

BOILER FEED AND CONDENSATE RECOVERY SYSTEMS Extend the life and efficiency of your boiler system

ECOAZUR BLUEWATER WATER PURIFICATION PLANTS

EMERGENCY VAPOR SCRUBBER SYSTEMS

Design of Purified Water and Water For Injection Systems. Hugh Hodkinson Engineers Ireland Chemical & Process Division

Well Water Iron Removal Using Quantum DMI-65 Granular Filter Media

Portable Swimming Pool Reverse Osmosis Systems

A meaningful, cost-effective solution for polishing reverse osmosis permeate

SECTION 13XXX DISPERSAL PUMP STATION (4x4 DiPS)

Troubleshooting Your RO

Cal Water 1961 Petra Lane, Placentia, CA (800) CAL-WATER (800) FAX: (714)

How To Clean Up A Reactor Water Cleanup

Stenner Pump Chlorinator Installation & Start Up Guide

Cartridge Filter Application Notes

1. Conductivity < 15 micro ohms/cm 2. ph of 6.0 to Nonvolatile TOC content < 1.0 ppm

Culligan Exchange Tank Deionization Service

Alfa Laval PureBallast 3.1

TECHNICAL BROCHURE B5-33GB 5GB, 7GB, 10GB, 18GB, 25GB, 33GB HIGH PRESSURE MULTI-STAGE BOOSTER PUMP

SECTION 13XXX CONTROL DESCRIPTION (DICP Models NC, 412, 622, 826, 1030)

Differentiation Summary. Revolutionizing Water Clean-Up Opportunities

Watts Pure Water Systems

Centro-Matic Automatic Lubrication Systems System Controls

D. Open hydronic systems, including [condenser] [fluid-cooler spray] water, shall have the following water qualities:

RO / NF Cleaning Guidelines

FILTRATION SOLUTIONS PhARmAceUTIcAL manufacturing FILTRATION SPecIALISTS

Basics of Reverse Osmosis

SENTRA SERIES WATER UNITS. 30 to 300 F Process Temperatures. 1/2 to 7.5 HP Centrifugal Pumps ( GPM) 10 to 34 KW Stainless Steel Heaters

SIOUX HYBRID WATER HEATER

Reverse Osmosis (RO) Drinking Water System. Product Manual

Page 1 of 6 FACILITY PLANNER NAME ADDRESS ZIP PROJECT LOCATION

LABORATORY PRODUCT GUIDE

Recommended Product Specifications Fuel Day Tank System Tramont UTRS Fuel Day Tank

The Breather Box. High Performance Grade-D Breathing Air Filtration system. BB50-cO

Direct Water purification system Pure & ultrapure water directly from tap water

MC4-50 Feeding System

DIESEL & JET FUEL FILTRATION EQUIPMENT. Applications:

Some Criteria for Choosing a Steam Boiler for a Microbrewery

Pall Aria AP Series Packaged Water Treatment Systems

Simply complete the enclosed Warranty Form with contact details, or us with your details and date of purchase.

Nine Industrial Scale V SEPs. Feed Tank V SEP. Feed Pumps (Three) Concentrate. Tank. V SEP Treatment System

Mobile CIP Systems. Conceptualized, Designed, Engineered and Manufactured by: Gamajet Cleaning Systems: The Tank Cleaning Experts

Sanitary Type Electronic Flow Switches

FAMILY PROTECTION FROM WATERBORNE DISEASES

DIESEL FUEL CONDITIONING

Innovation and Progress in Water Treatment Technology

HUMIDIFICATION SYSTEMS: A COST AND EFFICIENCY COMPARISON

Kompressoren. Adsorption Dryer AD

Sterile ReadyToProcess Hollow Fiber Cartridges Instructions for Use

CoolTop. A unique water cooled air-conditioning unit for server room cooling from the top AC-TOPx-CW-240/60

Automatic Self-Cleaning Strainers

Chemical Decontamination and Fluid Handling Services

SECTION 11 drinking Water Systems

Bacteria Control Troubleshooting Guide for Automated Watering Systems

HR Heated HB Blower. Smart Solutions for Drying Compressed Air. Dual Tower Heat Reactivated Desiccant Air Dryer

PRICE LIST Brutto incl.moms Januar 2011

HYDROSTATIC TEST PUMPS

Design & Construction Standards, Revised January

PACKAGE TERTIARY FILTER SYSTEM SPECIFICATIONS MODELS TF-2-6-C THROUGH TF-2-35-C

Heating Water by Direct Steam Injection

PVS 185, 600, 1200, 1800, 2700 Series Portable Purification Systems

RECON WATER HEATER INSTALLATION FORM

Water Equipment Technologies. Advanced Membrane Technologies for Solving Worldwide Water Problems

Advantage System Elix The Best in Pure Water

Power consumption (kw)

Water for Injection (WFI) and Pure Steam Production in a Lean Manufacturing Environment. Larry Zanko Project Manager STERIS Corporation

Complete. Water Solutions. for Rural India

Stanadyne Fuel Manager Diesel Fuel Filter/Water Separator System. User s Guide

HYDRYER TYPE P Heat Regenerative Dryers ISO 9001 CERTIFIED

7. TECHNICAL ASPECTS OF DESALINATION PLANT

High Vacuum Transformer Oil Purification Systems (HVTOPS) & Dielectric Oil Purification Systems (DOPS)

MEMCOR membranes for drinking water applications. Water Technologies

INSTALLATION, OPERATION AND MAINTENANCE MANUAL

Guidelines for Preparing for a Temporary Steam Plant

Hollow Fiber Cleaning and Storage Procedure

Reuse of Alternative Water Sources for Cooling Tower Systems Two Case Studies Using Non-Traditional Water Sources

Axial and Mixed Flow Pumps for Large Volume Pumping

Laboratory & Scientific Line. Bulk Steam Sterilizers. Since

GE Oil & Gas. Texsteam * Pumps: precise chemical injection pumping

Maxi Pressurisation Units (Maxi, Maxi Plus & HP)

Electronic Flow Switches

*.ppt 11/2/ :48 PM 1

Ion Exchange Softening

A Guide to Trouble-Free Cooling Towers

SIMPLE... AFFORDABLE... ENERGY EFFICIENT... LOW MAINTENANCE...

Drinking water for Gaza Elaboration concept 2

In-Line Electronic Flow Switches

TECHNICAL BROCHURE BAQUABII. * Available up to 100 GPM systems. Aquavar ABII VARIABLE SPEED CONSTANT PRESSURE SYSTEMS

Marina Bay on Boston Harbor Water-treatment system by OilTrap Environmental

WANJET. Sprayers. Wanjet sprayers has been produced since 1978.

When it Rains it Stores tm

POLARIS AIR COMPRESSOR SERIES. engineering. excellence. stellar. performance. A World Leader for Centrifugal Compressors

TECHNICAL SPECIFICATIONS

OPERATING AND MAINTENANCE MANUAL

Transcription:

REVERSE OSMOSIS WATER TREATMENT LTF 2, LTF 3 and LTF 4 SERIES RO SYSTEMS 14,400 TO 252,000 GALLONS PER DAY AND LARGER Lakeside Water for Affordable Pure Water Technology 1 P a g e

Packaged Reverse Osmosis Systems for Brackish Water Lakeside Water incorporates the latest technology and high quality components in manufacturing a complete line of systems to treat all your applications. Our pre-engineered and custom designed systems purify water by reducing dissolved minerals, particles, organics and other contaminants in your water up to 98%. Membrane technology is used to separate the feed water into two streams. One stream of water is the high purity water (permeate) and typically flows into an atmospheric tank for the future use. The other water stream produced is called the reject or concentrate stream and carries the impurities to the drain. Lakeside s waste water reuse system reduces your disposal costs. Sequence Of Operation If the level float switch located inside the atmospheric product tank is calling for water, the standard programmable controller will signal to OPEN the automatic feed valve and pressurize the pump suction. It then signals to START the high pressure pump (HPP) pumping high pressure water through the membranes. This is where the two streams of water are separated. The Permeate water is sent to the atmospheric tank, where a high level float switch detects a full tank signal and shuts down the high pressure pump. A post low pressure membrane flush rinses water to drain. The concentrate water is discharged to a floor drain. The two streams must be adjusted properly to maintain the manufactures operating guidelines to produce high purity water. The re-pressurization pump skid delivers the permeate water from the storage tank to the end-user locations. A recirculation loop is typically utilized on atmospheric tank applications to provide constant pressure to service. Pre-Treatment -Typically, a reverse osmosis system requires pre-treatment of the water supply to prevent hardness, iron fouling or chlorine destruction of the membranes. Our team of engineers have years of experience and can design a chemical feed or equipment pre-treatment package to meet your application requirements. 2 P a g e

Pre-Treatment Options: Multi- Media filters reduce the turbidity down to 10 microns. The lower the SDI number, the better protection of the membranes. Carbon filtration is designed to provide membrane protection by removing the free chlorine and organics that cause membrane destruction and fouling. Water Softeners protect the membranes by removing all hardness, preventing scaling that reduces: membrane life, water quality, water volume production and equipment down time. OR Chemical feed systems that inject chemicals for ph, anti scaling and de-chlorination into the feed water for membrane protection. Quality Control Lakeside s team of engineers take pride in designing performance systems. Our engineers program, test, verify operation and release each system for shipment. Lakeside s high level of quality control ensures a happy and satisfied customer. Your success is our Top Priority! Lakeside s Standard Microprocessor Controller on the 4 systems displays the operating status and conductivity. Monitors / Controls: high pressure pump, inlet solenoid, automatic flush valve, low and high pressure switches, RO storage tank level switches (1 or 2), operating hours, pre-treat lockout and water temperature. The economical controller features LCD with easy touch key pad and user friendly programmable flush modes. Electrical specifications: 120/240 vac, 50-60 hz, 25 watts. 8 x 6 x 4 NEMA 4X. Allen Bradley PLC is standard on the 8 systems. By simply programming the parameters on the 6 HMI EZ Touch color screen, the Reverse Osmosis system is fully automatic. The HMI displays the operating status and conductivity while monitoring and controlling: flow meters, flush times, high pressure pump, inlet solenoid, automatic flush valve, low and high pressure switch, RO storage tank level switches (1 or 2) and operating hours. Racked instrumentation includes: inlet, suction, pump, permeate and reject pressure gauges. The pre-treatment is coordinated, controlled and monitored by the PLC and can be programmed to your specifications. NEMA 4X with 120/240 VAC, 50-60 HZ. Ethernet port for data export is included. 3 P a g e

Standard Features: Ultra-Low Pressure Membranes reduce power consumption by 30% and provide high rejection rates FRP membrane vessel housings 4 systems use polypropylene cartridge filter vessels and 304 stainless steel for 8 systems with 1 micron filters-high protection Stainless Steel multistage centrifugal high pressure pump and piping Skid mounted permeate and reject throttling valves with flow meters Racked & labeled liquid filled pressure gauge package 4 systems Include in-line rotameters 8 systems include Signet paddle wheel flow sensors Low and High Pressure switch protection PLC Automated Permeate Flush on 8 systems protects the membranes from impurities ensuring longer life High efficiency motor (TEFC), 208-230/460VAC, 3 phase, IEC motor starter and disconnect on system Skid mounted construction on a welded epoxy coated steel frame provides the ultimate corrosion resistance Fiberglass option available System Options: Multi-media and/or carbon filtration, water softener treatment, chemical feed water treatment Optional I/O Expander: Permeate divert or remote alarm relay, auxiliary relay, tank low switch Temp gauge, ph, ORP and conductivity sensors Product water diversion RO pressurized and atmospheric storage tanks Re-pressurization pump skids and controls Membrane clean in place (CIP) Skid mounted or portable roller skid (CIP) UV sterilization and sub-micron filtration Deionization polishing systems deliver high quality water up 18 Meg-ohm Pre-Engineered products, custom controls, programming and engineered systems available *Reverse Osmosis Systems require a membrane flush every 24 hours (minimum) to reduce bio-growth and fouling. 4 P a g e

Optional Post Treatment Equipment: Degasifies, chemical feed injection systems, and UV sterilizers are provided to assure the product water is within specifications. Deionizers polish the RO product water to produce up to 18 meg-ohm/cm water. LTF 2 Specifications: Model Capacity (GPD) Motor Typical Max HP Connections (in.) Feed Product Reject Dimensions L x W x H (in.) Ship Wt. (lbs.) LTF2-14400 12,540 14,040 5 1.5 1 1 135 x 38 x 70 870 LTF2-19200 16,700 18,690 7.5 1.5 1 1 135 x 38 x 70 950 LTF2-24000 20,900 23,370 7.5 1.5 1 1 135 x 38 x 70 1030 LTF2-28,800 25,000 28,040 10 1.5 1.5 1 135 x 38 x 70 1170 LTF 3 Specifications: Model Capacity (GPD) Motor Typical Max HP Connections (in.) Feed Product Reject Dimensions L x W x H (in.) Ship Wt. (lbs.) LTF3 42,000 35,040 41,600 10 2 1.5 1 145 x 36 x 80 1940 LTF3 63,000 52,560 62,400 15 2 1.5 1 145 x 36 x 80 2490 LTF3 84,000 70,080 83,220 15 2 2 1.5 145 x 36 x 80 3095 LTF3 105,000 87,600 104,020 20 2.5 2 1.5 145 x 50 x 80 3440 LTF3 126,000 105,100 124,800 25 2.5 2.5 1.5 145 x 50 x 80 3865 5 P a g e

LTF 4 Specifications: Model Capacity (GPD) Motor Typical Max HP Connections (in.) Feed Product Reject Dimensions L x W x H (in.) Ship Wt. (lbs.) LTF4 112,000 93,400 110,900 25 2.5 2 1.5 192 x 50 x 80 3905 LTF4 140,000 116,800 138,700 30 3 2.5 2.5 192 x 50 x 80 4260 LTF4 168,000 140,160 166,440 30 3 2.5 2.5 192 x 50 x 80 5000 LTF4 210,000 175,200 208,100 40 4 3 3 272 x 50 x 80 5800 LTF4 252,000 210,240 250,000 40 4 3 3 272 x 50 x 80 6300 1). Total system capacity is after 3 years of operation at standard conditions with 55F. or warmer feed water. Maximum capacity requires ideal operating conditions and high area membranes. 2). Standard operating conditions are 1000 ppm TDS softened feed water, SDI less than 3.0, 7- to 80% conversion, 50 psi. Inlet. 3). Detailed specifications, drawings and computer projections are available on request. 4).Standard power is 460 VAC, 30, 60 Hz. 6 P a g e