1 Reverse Osmosis Parts Introduction
2 Reverse Osmosis Flow Chart AQUAPRO INDUSTRIAL CO.,LTD Triple Membrane WATER IMPROVER WATER IMPROVER 2
3 Reverse Osmosis Electrical Diagram AC-220V Power (2.0 point) (W) (B) (R) White Black Red GROUNDING Blue Brown ON/ OFF SWITCH Green Black MEMBER W A T E R QUALITY A S S O C I A T I O N Control Box PUMP FLUSH SOURCE FULL POWER R MANUAL WATER FLUSHING CONTROL Green Blue Blue Full water switch TO FLOATING / H.P. SWITCH Yellow Yellow 2T T3 T O C Red Red Black YELLOW/GREEN A2 MC 95 Flushing Solenoid Valve : Red 1 3 BROWN BLUE Magnetic Switch : Green ( A2, 95) Low Pressure Switch : Yellow Electrical Pressure valve INLET DUAL T.D.S. WATER ON/OFF OUTLET RO PUMP U1 W2 Red 2T1 T.D.S. TEST BAR INLET WATER T.D.S. TEST BAR PURIFIED WATER V1 U2 W1 V2 Black 6T3 RO Pump internal wiring 3
4 Reverse Osmosis Specification Filter Housing with Cartridges 20" Filter Housing 20" Cartridge: Sediment 5, 1micron Carbon Block Carbon Block Vertical Pump Type: 3HP 4HP 5.5HP Actuator Shutting down while Low pressure switch sends out signal. 1". Solenoid Valve Flushing while control box sends out flushing signal GPD: 1/2" GPD: 1/2" GPD: 1/2" GPD: 3/4" 10000GPD: 3/4" 4
5 RO Membrane & RO Housing (A) RO Membrane Housing (B) RO Membrane: 1.Specification of Membrane (1) Max. Operation Pressure: 300PSI O (2) Max. Operation Temperature: 45 C (3) Turbidity (NTU): <1 (4) Chlorine: 0.1PPM (5) PH Range: 2~11 (6) Flow Rate: 10GPM (7) Max. S.D.I. Index: 5 (8) Salt Rejection Rate: 96% 2.Application Data For System Design: (1) Max. Operation Pressure: 190~220PSI O (2) Max. Operation Temperature: 45 C (3) Turbidity (N.T.U.): <1 (4) Chlorine: <0.1PPM (5) PH Range: 4~11 (6) System Inlet Water pressure: 3.5KG+/- 15% (7) Max. S.D.I. Index: 4 (8) Salt Rejection Rate: 96% (9) Product Water Generate: 25% O (C) Testing Environment: 25 C/pH=8 (1) NaCl: 2000 PPM (2) Operating Pressure: 225PSI (3) Recovery Rate: 15% 600PSI` AQUAPRO INDUSTRIAL CO.,LTD Reverse Osmosis Specification Water Inlet pressure Gauge 2 0~15 KG/CM Oil-Filled Pressure Gauge 2 *Not allow to operate under 1.5KG/CM * RO Inlet Water Pressure Gauge 2 0~35KG/CM (30bar)Oil-Filled Pressure Gauge, set the pressure between 150~180PSI to get the maximum performance. Pressure Regulator Adjust Clockwise to boost RO operating pressure, Counterclockwise to Lower operating pressure. Gate Valve Only for vertical pump using. 5
6 Flow Meter AQUAPRO INDUSTRIAL CO.,LTD Reverse Osmosis Specification 0.2~2GPM 0.5~5GPM 1.0~10GPM 2.0~20GPM Microprocessor Controller Electromagnetic Switch 1HP FOR 1/2 HORSE POWER MOTOR (Single Phase) 3HP FOR 1 HORSE POWER MOTOR (Single Phase) 5HP FOR 3 HORSE POWER MOTOR (Single Phase) 7.5HP FOR 4 OR 5 HORSE POWER MOTOR (Three Phase) Model: MC-2---Six lights microprocessorized automatic flush controller. Power: 230VAC, 50/60Hz, or 24VDC Function: Controller processing steps: (1) Automatically flush for 1 minute and 30 seconds when the machine starts its first time. (2) Water-generating detection: Automatically flush for 1 minute and 30 seconds after the accumulated time reaches 12 hours. (3) Input water detection: It will not start control system (stop pump/solenoid valve) if the low pressure switch delays for 5 seconds (out of source water). (4) Output water detection: When production water is full, Full water lamp is on and stop pump/solenoid valve. Configurations: Water-generating Water-input Full-water Power Pump Flush Sorce Full INDICATION OF EACH LAMP: PUMP: Water-generating, will be on when pump is generating. FLUSH: Auto flush function, will be on when it is flushing automatically. SOURCE: Water-input, will be on when it is short of water. FULL: Full-water, will be on when water tank if full. POWER: Will be always on. MANUAL: Manual flush function, will be on when flushing by manual. WRING INSTRUCTION: 1. Low Pressure Switch- YELLOW with AMP connector 2. Floating/Pressure Switch-BLUE with AMP male connector 3. Flushing Valve-RED with AMP connector 4. Booster Pump-GREEN/BLACK With AMP connector 5. Inlet Valve-GREEN/BLACK With AMP connector 6 Manual
7 Reverse Osmosis Installation Reminder 1. Make sure the voltage and phase of the system you order, never use wrong setting. 2. Check the pure/concentration water are piping right. 3. The power line core should large enough (not less than 3.5 mm) 4. Be ware do not let brine flow through the system while water softener is backwashing. 5. Make sure the water softener's In/Out are connected correct. 6. Measure feed water pressure with a water pressure gauge. Feed water pressure is preferably to be 35 psi and the minimum is 26 psi. If lower than 26 psi, it should install a booster pump at the feed water location. 7. Check prefilters every week to make sure the water supply. 8. If the equipment comes with Ultraviolet Device, make sure you have a steady Power supply in protection of the U.V. Lamp. Replacement of Filter Cartridges The replacement of filter cartridges depends greatly on the quality and condition of the water in local area where the reverse osmosis system is placed. Please follow the instructions below to ensure good performance of the system. 1. It is most recommended to replace the filter cartridges every three months. 2. After a while's usage, check regularly Reverse Osmosis Panel's Inlet Water Water Pressure Gauge. If its water pressure is 15% lower than the feed water Pressure, it is recommended to replace the filter cartridges. E.g. If the feed water pressure is 2bar (35psi), and the Inlet Water Gauge's Index is 1.7bar (29psi), it is recommended to replace the filter cartridges. 7
8 Reverse Osmosis Setup Suggestion 1. If possible, install the active carbon filter and water softener to ensure the incoming water quality. 2. Water softener should regenerate the resin by adding salt to its salt tank. Do it regularly. 3. If not install the water softener, lower the pure/concentration water ratio by adjusting the pressure adjust needle valve(ro Needle Valve). 4. Change pure/concentration water ratio, you should always notice the motor operating pressure, adjust it from the PROCON bypass to ensure the motor is running at the best condition If your water incoming pressure lower than 1 kg/cm, remember to add a pump in front of the system. 6. The lines left on side of autoflushing timer are used for level control or high pressure switch (If you are using a pressurize storage device). 7. Please use Hardness Tester (5B) to know your water hardness. Make sure the water softener is working fine. 8. Please use the Chlorine Tester to detect the active carbon's working condition, change active carbon when necessary. 9. Cleaning R.O. membrane when the product rate declined 10% or pressure drop up 15%, the following figure tell you how: a. Take pure water pipe (O) out and put it into drain. b. Put concentration water pipe (P) into cleaning solution (Q). c. Start pump (Notice: Make sure to release the air gather in pipes). d. Close (M) valve, open (N) valve, let cleaning solution suck into R.O. system. e. Adjust needle valve (Pressure adjusting valve) to the maximum level. And let it run for 30 minutes. After 30 minutes, adjust pressure to 60 psi, run for another 30 minutes. f. Put concentration water pipe back to the drain, adjust pressure to maximum level, flush for 1 minute and it's done. Note: Using the right cleaning solution to clean different types of scale, the cleaning solution O PH should range from 3 to 10 at temperature of 35 C. 8
9 ROUTE FOR ACTUATOR F M T O C INPUT OPEN CLOSED 9
10 Reminder 1. INLET PIPING SIZE (1) 1500~2000GPD, 1Membrane Inlet Piping: 3/4" ~ 1" (2) 3000~4000GPD, 2 Membranes, 1HP Motor, Procon Pump Inlet Piping: 3/4" ~ 1" (3) 3000~4000GPD, 2 Membranes, 3HP, Grundfos Pump Inlet Piping: 1" (4) 6000~14000GPD, 4 ~ 8 Membranes Inlet Piping: 1" ~ 1-1/4" 2. INSTALLATION OF AN ADDITIONAL PUMP The inlet water pressure must be at least 1.5kg / cm2. When inlet water pressure is under 1.5kg/cm2, equip the system with an additional pump to increase the inlet water pressure. The selection of the additional pump must be based on actual Situations. 10
4 Stage Barracuda RO/DI Instruction & Owner s Manual
4 Stage Barracuda RO/DI Instruction & Owner s Manual 7208 Aloma Ave Suite 600 Winter Park, FL 32792 Phone 407-599-2123 Fax 407-599-2124 www.aquariumwaterfilters.com www.aquafx.net 7208 Aloma Ave Suite
FILLING AND PURGING THE SYSTEM
FILLING INSTRUCTIONS FOR WATER HEATER OR CONDENSING BOILER (City Water) Safety tip: Before beginning, turn off power to boiler and circulator. FILLING AND PURGING Step 1: Close Return Manifold Isolation
Overheating limit control
Pahlén electric heater Maxi Heat with digital control is a compact and effective heater for swimming pools. It consists of a glassfibre reinforced polypropylene tank containing resistance-type heating
Watts Pure Water Systems
Watts Pure Water Systems WM-120-PT Installation and Operation Manual Premier Water Systems Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before
Stenner Pump Chlorinator Installation & Start Up Guide
Clean Water Made Easy www.cleanwaterstore.com Stenner Pump Chlorinator Installation & Start Up Guide Thank you for purchasing a Clean Water System! With proper installation and a little routine maintenance
Iron Air Charge 2510-SXT Installation & Start-Up Guide
Iron Air Charge 2510-SXT Installation & Start-Up Guide Thank you for purchasing a Clean Water System! With proper installation and a little routine maintenance your system will be providing iron free water
Thermo Scientific Barnstead TII Pure Water Systems. Pure water. Pure research. Total confidence.
Thermo Scientific Barnstead TII Pure Water Systems Pure water. Pure research. Total confidence. Thermo Scientific Barnstead TII Pure Water Systems Ideal for any daily application needs for pure water,
Simply complete the enclosed Warranty Form with contact details, or email us with your details and date of purchase.
INSTALLATION & SERVICE GUIDE 4 STAGE UNDERSINK REVERSE OSMOSIS WITH SERVICE MODE Congratulations on your purchase of the most advanced Reverse Osmosis Water Purification system available. Part of our commitment
LABORATORY PRODUCT GUIDE
LABORATORY PRODUCT GUIDE THE NEXT GENERATION OF LABORATORY WATER PURIFICATION SYSTEMS PURITE WATER PURIFICATION SYSTEMS Purite specialises in the design, development and manufacture of advanced, high performance
ACCUMULATOR INSTALLATION
7001-7 ACCUMULATOR INSTALLATION BRAKE ACCUMULATORS I 308L93 Rae 7-59710 Issued 6-93 Printed in U.S.A 7001-8 Removal ACCUMULATOR VALVE 1. Park the machine on a level surface and lower the. loader bucket
PRICE LIST Brutto incl.moms Januar 2011
PRICE LIST Brutto incl.moms Januar 2011 Rev. 1 2011 SELMAR Technologies S.r.l. Reverse Osmosis Watermakers PROGRESS - Thermal circuit breaker - Salinity meter SEL-MC40 15 360 18A-12V (9A-24V) 64 x 25 x
Well Water Iron Removal Using Quantum DMI-65 Granular Filter Media
Well Water Iron Removal Using Quantum DMI-65 Granular Filter Media ASME Research Committee Power Plant and Environmental Chemistry Overland Park, Kansas April 2-4, 2007 Prepared by: W. H. Stroman Primary
Drinking water for Gaza Elaboration concept 2
Herontwerp 2014 Drinking water for Gaza Elaboration concept 2 Docent: Hassanpur Golriz, D. (Damon) Student: Roger Sylverstre Yapo (Group 4) Content 1) Reverse osmosis description --------------------------------------------------------------------------
Fleck 4650. Service Manual INSTALLATION AND START-UP PROCEDURE TABLE OF CONTENTS JOB SPECIFICATION SHEET
Fleck 4650 Service Manual TABLE OF CONTENTS JOB SPECIFICATION SHEET...1 INSTALLATION AND START-UP PROCEDURE...1 CONTROL VALVE DRIVE ASSEMBLY...2 CONTROL DRIVE ASSEMBLY FOR CLOCK...3 BYPASS VALVE ASSEMBLY...4
Oildyne. 165 Series Hydraulic Power Units. Pressures to 241 bar (3500 psi) Flows to 5.4 lpm (1.4 gpm)
Oildyne Hydraulic Power Units Pressures to 241 bar (3500 psi) Flows to 5.4 lpm (1.4 gpm) 11 Power Unit Features We are pleased to introduce our new power units. The power units let you put more power where
LG Air Conditioning Multi F(DX) Fault Codes Sheet. Multi Split Units
Multi Split Units If there is a fault on any LG Multi unit, an Error mark is indicated on the display window of the indoor unit, wired-remote controller, and LED s of outdoor unit control board. A two
Water Treatment and Reverse Osmosis Systems
Water 2012 Treatment Pure Aqua, and Inc. Reverse All Rights Osmosis Reserved. ystems Worldwide Experience uperior Technology About the Company Pure Aqua is a company with a strong philosophy and drive
Model 5600 & 5600 Econominder
Service Manual IMPORTANT: Fill in pertinent information on page 3 for future reference. Table of Contents Job Specification Sheet...................................................................................
Model 5600SE Downflow
Service Manual IMPORTANT: Fill in pertinent information on page 3 for future reference. Table of Contents Job Specification Sheet...................................................................................
Centro-Matic Automatic Lubrication Systems System Controls
Selecting the right controls for your automated lubrication system is one of the last steps in the design process. Several different models may be chosen to control power-operated pumps, depending on the
A meaningful, cost-effective solution for polishing reverse osmosis permeate
A meaningful, cost-effective solution for polishing reverse osmosis permeate Electrodeionization or EDI, is a continuous and chemicalfree process of removing ionized and ionizable species from the feed
TECHNICAL SERVICE DEPARTMENT Technical Service Bulletin 1-800-432-8373. Tankless Electric (RTE) Troubleshooting
Sequence of Operations 1 Power supply and field wiring block 2 Energy Cut Off (ECO) 3 Water flow plunger and cold inlet 4 Magnetic flow switch 5 Water temperature thermistor 6 Control panel and circuit
Example. Fluid Power. Circuits
Example Fluid Power Circuits To Enhance Symbol Reading Skills To Work On Circuit Reading Skills With Answers HI LO Pump Circuit 18 A1 B1 17 16 15 13 Set 14 2,000 PSI PG2 Set 500 PSI 12 11 7 8 10 PG1 9
Model 5600 & 5600 Econominder
Model 5600 & 5600 Econominder Service Manual IMPORTANT: Fill in pertinent information on page 3 for future reference. Table of Contents Job Specification Sheet.........................................................................
RiOs 3, 5, 8 Water Purification Systems
RiOs 3, 5, 8 Water Purification Systems Reliable and affordable pure water solutions Merck Millipore is a division of Reliable and affordable pure water solutions Your water purification needs Reliable,
Please keep these operating instructions in a safe place.
Please keep these operating instructions in a safe place. Dear Customer: Check this product for visible damage immediately upon receipt. Inform the shipper if there is any shipping damage. Note that damage
1. Conductivity < 15 micro ohms/cm 2. ph of 6.0 to 9.0 3. Nonvolatile TOC content < 1.0 ppm
PART 1: GENERAL 1.01 Purpose: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The responsibility of the engineer is
R22. K Control. Indoor Unit. Nomenclature. Compatibility PL H 3 G K H B. Unit style Heat Pump Horse Power
R22. K Control. Indoor Unit. Nomenclature. PL H 3 G K H B Compatibility Unit style Heat Pump Horse Power Control Boost Heaters R22. K Control. Outdoor Unit. Nomenclature. PU H 3 Y K A Compatibility Outdoor
with MERCURY FREE 1 HP Relays ! WARNING Before using this product read and understand instructions.
B Installation & Maintenance Instructions MM-414 Series 150E and 157E Low Water Cut-Off/Pump Controllers For Steam Boilers and Other Level Control Applications A Typical Applications: Primary or secondary
RO Reverse Osmosis equipments
RO SYSTEMS RO Reverse Osmosis equipments A range of Reverse Osmosis equipment designed to provide the highest performances with flow rates demand from 50 to 1000 l/h. Every component of the equipment is
ELECTRIC CENTRAL HEATING FLOW BOILER
ELECTRIC CENTRAL HEATING FLOW BOILER EKCO.T Used product can t be treated as general communal waste. Disassembled appliance has to be delivered to the collection point of electrical and electronic equipment
Energy Recovery Device isave 21-40
Data sheet Energy Recovery Device isave 21-40 Lenntech [email protected] Tel. +31-152-610-900 www.lenntech.com Fax. +31-152-616-289 Table of Contents 1. General information....3 2. Benefits...3 3. Technical
DOW Ultrafiltration. Case History. High Turbidity and Temperature Fluctuation No Obstacle for DOW Ultrafiltration
Case History High Turbidity and Temperature Fluctuation No Obstacle for Site Information Location: HeBei, China Capacity: 12 m 3 /h (5283 gpm) Purpose: Pretreat sea water prior to RO system Time in Operation:
LG Air Conditioning - Universal Split Fault Codes Sheet. Universal Split Systems
Universal Split Systems If there is a fault on any LG Universal unit, a two digit number will appear on the remote controllers led display. If the unit does not have a remote controller the fault will
How To Replace A Reverse Osmosis Water Tank
ALL MODELS REVERSE OSMOSIS WITH NONAIRGAP FAUCET 1. Read all instructions carefully before starting installation. 2. Find the cold water line beneath your sink. The cold water is typically on the right.
Troubleshooting Salt Generators
Troubleshooting Salt Generators NOTE Turn off power to unit prior to attempting service or repair. Problems and Corrective Action Problem Possible Cause Corrective Action Low or no chlorine. Low stabilizer
WHOLESALE DIRECT INC. 5620 WEST 65TH STREET
Auto Pump V 200 100 0 100 Max Rating Vehicle mount compressor ensures truck air brake system is properly pressurized for immediate dispatch from station Pressure switch regulated operation automatically
Master Programming Manual for TotalCare, CareSoft Elite, CareSoft Pro, Ion Pro and CareClear Pro Models
Master Programming Manual for TotalCare, CareSoft Elite, CareSoft Pro, Ion Pro and CareClear Pro Models Effective December 2014 Button appearance and position may be different than actual valve. Cycle
OPERATING AND MAINTENANCE MANUAL
OPERATING AND MAINTENANCE MANUAL AUTOMATIC SCREEN FILTER FMA SERIE 5000 Sistemas de Filtrado y Tratamiento de Fluidos S.A. Pol. Industrial La Armentera Parc. 86 INDEX INTRODUCTION...3 TECHNICAL CHARACTERISTICS...5
VOYAGER 570G. 744A Sprayer Control
VOYAGER 570G 744A Sprayer Control U S E R M A N U A L U S E R M A N U A L Table of Contents CHAPTER 1 - INTRODUCTION...1 SYSTEM CONFIGURATIONS...1 KIT CONTENTS...3 CONTROL HOUSING ASSEMBLY...5 CHAPTER
Direct Water purification system Pure & ultrapure water directly from tap water
Milli-Q Direct Water purification system Pure & ultrapure water directly from tap water ADVANCING LIFE SCIENCE TOGETHER Research. Development. Production. Pure & ultrapure water from a single water system
Service and support. Did you know? Table of Contents. Less weight, lower fuel costs, higher speeds. Fresh water wash downs
Sea Recovery - The trusted source for fresh water Enjoy the Benefits of a Sea Recovery Watermaker... Sea Recovery has manufactured the most innovative and intuitive watermakers for the past 30 years. By
Compressor Service & Maintenance Manual
Compressor Service & Maintenance Manual C Series COMPRESSOR (D)C1103 (D)C1203 (D)C2106 (D)C2206 (D)C3210 Copyright 2006 DCI. All Rights Reserved. 92311, Rev. C, 08/13 1 C1000 Series Service & Maintenance
Owner s Manual. 5600 / 5600 Econominder
5600 / 5600 Econominder Owner s Manual For questions or in case of emergency, please call your local service technician (preferably the one who installed the system). Product Features, Benefits, & Job
MBA-MM-1040/10/13/1665 MULTI MEDIA FILTERS
MASTER Water Conditioning Corp. www.masterwater.com Installation and Operation Manual MBA-MM-1040/10/13/1665 MULTI MEDIA FILTERS with the 263/742 Logix Control Valve June 2010 Table of Contents Page No.
MASTER. Water Conditioning Corp. MP-MBA-15T-30T using the 255/762 Logix Control Valve. Installation and Operation Manual. www.masterwater.
MASTER Water Conditioning Corp. www.masterwater.com Installation and Operation Manual MP-MBA-15T-30T using the 255/762 Logix Control Valve July 2006 Table of Contents Page No. Topic Description 1 Model
EcoSoft Water Softener. General Installation Guide
EcoSoft Water Softener General Installation Guide Planning Our Softener Installation Please observe any local or national regulations concerning the installation of your water softener. Check that there
THE RO+UV Water Purifier USER MANUAL
THE RO+UV Water Purifier USER MANUAL Contact us : Toll Free Number: 1800-2-585858 Email: [email protected] Visit: www.tataswach.com 1 Table of Content: Sr.No Content Page No 1 Welcome Note 1
PWC-500/1000/1010/1500
SERVICE MANUAL for by Vertex Model PWC-500/1000/1010/1500 P/N man-7008 Table of Contents Introduction Cooler Set-up Remove Top Cover Remove/Replace Float Remove/Replace Hot Tank Faucet Repair Hot Tank
DIESEL & JET FUEL FILTRATION EQUIPMENT. Applications:
E X T E N D I N G Y O U R E N E R G Y DIESEL & JET FUEL FILTRATION EQUIPMENT Applications: Back-Up Diesel Generators Gas Turbines Fueling Terminals for Trucks & Buses Marine Mining Railroad Agriculture
Cartridge Filter Application Notes
Industrial Water Purification (800) CAL-WATER Cal Water 1961 Petra Lane Placentia, CA 92870 FAX: (714) 792-0794 Web Page / Email: www.cal-water.com Cartridge Filter Application Notes Cal Water offers a
Pro Logic Version 4.10. Diagnostics Manual
Pro Logic Version 4.10 Diagnostics Manual Turbo Cell & Control Electronics 2009 Hayward Industries Table of Contents Important safety instructions Pg. 1 No Cell Power 1 & No Cell Power 2 Pg. 2 No Cell
Automatic Self-Cleaning Strainers
Applications Water and Liquid service Power Industry Cooling water Pulp & Paper Removing fibers Process Equipment Protect equipment Metal & Mining Quenching, blast furnace cooling Automatic Self-Cleaning
3-Way heavy duty flow control, with pressure compensated and solenoid controlled priority flow
1/6 RE 18309-3/06.10 Replaces: RE 18309-3/04.10 3-Way heavy duty flow control, with pressure compensated and solenoid controlled priority flow A-VRFC3C-VEI-VS 0M.43.20.80 - Y - Z Description The flow control
Designed for multi-injector endurance testing, the
Designed for multi-injector endurance testing, the ETB Test Bench can optionally provide shot-to-shot mass measurement. The injectors are precisely subject to variable controls and hydraulic pressures
SALES SPECIFICATION. SC7640 Auto/Manual High Resolution Sputter Coater
SALES SPECIFICATION SC7640 Auto/Manual High Resolution Sputter Coater Document Number SS-SC7640 Issue 1 (01/02) Disclaimer The components and packages described in this document are mutually compatible
Kompressoren. Adsorption Dryer AD
Kompressoren Adsorption Dryer AD Adsorption Drying: why? Modern industries require compressed air that is increasingly filtered with low dew point and condensate. Today, the equipment is more sophisticated
OPL BASIC. Dosing System for Professional Laundry machines. Contents
OPL BASIC Dosing System for Professional Laundry machines Contents 1 Getting Started. Page 2 2 Installation. Page 4 3 Set Up & Operation. Page 8 4 Maintenance & Accessories. Page 10 5 Troubleshooting Page
TECHNICAL SPECIFICATIONS
Project: WATER TREATMENT FACILITY RO+EDI TECHNICAL SPECIFICATIONS February 2008 Guam Power Authority Taiwan Electrical and Mechanical Engineering Services, Inc. D:\G&J tech\island Choice\GPA\4-11-08 bid
PROGRAMMABLE LOGIC CONTROL
PROGRAMMABLE LOGIC CONTROL James Vernon: control systems principles.co.uk ABSTRACT: This is one of a series of white papers on systems modelling, analysis and control, prepared by Control Systems Principles.co.uk
PLC Control Unit for a CSM-C Steam Compact Clean Steam Generator
3.635.5275.251 IM-P486-19 CH Issue 2 PLC Control Unit for a CSM-C Steam Compact Clean Steam Generator Installation, Start-up and Operation Manual 1. Safety information 2. General product information 3.
What Is Membrane Performance Normalization?
What Is Membrane Performance Normalization? The majority of Reverse Osmosis (RO) systems normally will operate under fairly steady conditions over long periods of time if operating parameters remain constant.
Automation & Sanitization REPLACEMENT PARTS
& Sanitization PROLOGIC GLX-PCB-PRO Main PCB, ProLogic GLX-PL-LOC-P-4 Display, Local, ProLogic, P-4 GLX-PL-LOC-PS4 Display, Local, ProLogic, PS-4 GLX-PL-LOC-PS8 Display, Local, ProLogic, PS-8 GLX-PL-LOC-PS16
AUTOMATIC TRANSFER SWITCH CONTROL UNIT OPERATOR S MANUAL
ATS-220 AUTOMATIC TRANSFER SWITCH CONTROL UNIT OPERATOR S MANUAL For Use in 208 to 240 Volts Single and 3 Phase ATS Systems With 110Volt AC or DC Control Motors and selenoids 4501 NW 27 ave Miami FL 33142
Medical Air Systems: Scroll
GENERAL The Chemetron skid mount scroll medical air system is designed to provide medical breathing air for hospital and medical institutions. This system meets NFPA 99 requirements for Level 1 breathing
Watts Family of water quality improvement products and equipment for whole house water treatment.
WATER QUALITY & CONDITIONING PRODUCTS Arsenic Iron Taste odors chlorine Hardness Turbidity Acid Water Taste odors chlorine sediment Watts Family of water quality improvement products and equipment for
Valve Proving System VPS 504 Series S06 (120 VAC) Series S05 (24 VDC)
Valve Proving System VPS 504 Series S06 (120 VAC) Series S05 (24 VDC) VPS 504 S06 (120 VAC) is: CSA Certified File # 1637485 CSA Requirement No. 4-01 (USA) Technical Information Letter R-15 (Canada) UL
SECTION 11 drinking Water Systems
SECTION 11 drinking Water Systems WaTEr QualITy PrOduCTS Catalog 10 Watts product specifications in U.S. customary units and metric are approximate and are provided for reference only. Watts reserves the
DIESEL FUEL CONDITIONING
COD FILTRATION DIESEL FUEL CONDITIONING REMOVE WATER & PARTICLES TO EXTEND FUEL INJECTOR LIFE & INCREASE COMBUSTION ENGINE FUEL EFFICIENCY Remove free water to saturation point with high single pass efficiency
SERVICE MANUAL SPLIT SYSTEM ROOM AIR CONDITIONER SHARP CORPORATION SHARP CORPORATION CONTENTS
SERVICE MANUAL SPLIT SYSTEM ROOM AIR CONDITIONER INDOOR UNIT AH-129 AH-MP14 OUTDOOR UNIT AU-129 AU-MP14 CONTENTS SPECIFICATIONS...2 EXTERNAL DIMENSIONS...4 WIRING DIAGRAMS...5 ELECTRICAL PARTS...6 MICROCOMPUTER
GEBCO (PTY) LTD - Netafim Product List - 1st August 2011
AQUANET PLUS & ITEC CONTROLLERS Globe - Solenoid, Manual Override and Mechanical Throttle Aquanet Valve - DC 20 mm BSP Valve (Solenoid Valve) 34500-001000 Aquanet Valve - DC 25 mm BSP Valve (Solenoid Valve)
Maxi Pressurisation Units (Maxi, Maxi Plus & HP)
Maxi Pressurisation Units (Maxi, Maxi Plus & HP) Installation and Maintenance Instructions Contents 1 Dimensions 3 1.1 Installation 4 1.1 Mains/boosted cold water inlet 4 1.2 Connection to the system 5
TECHNICAL SPECIFICATION FOR PROJECTION WELDING MACHINE (Qty. 2 Nos.)
TECHNICAL SPECIFICATION FOR PROJECTION WELDING MACHINE (Qty. 2 Nos.) 1. Requirement: Two (02) Nos. DC Type, 3 phase, 3 wire Projection Welding Machine is required for welding of ventilation M.S. / Stainless
POOL SUNSHINE IONIZER MODELS SPD, SPD2 AND SPS INSTALLATION INSTRUCTIONS
Sunshine Pool Products, LLC Manufacturer of Quality Pool & Spa Products 902 W 2010 S, Syracuse, Utah 84075 USA Voice: 801-825-4523 Website: www.sunshinepool.com Email: [email protected] POOL SUNSHINE
Electrodeionization (EDI)
Electrodeionization (EDI) Fact Sheet Cal Water Industrial Water Purification (800) CAL-WATER EDI is a continuous electro-chemical process of water purification where ion specific membranes, mixed bed resin,
12 Volt 30 Amp Digital Solar Charge Controller
12 Volt 30 Amp Digital Solar Charge Controller User s Manual WARNING Read carefully and understand all INSTRUCTIONS before operating. Failure to follow the safety rules and other basic safety precautions
SECURITY SYSTEM ADP-CAN
INSTALLATION INSTRUCTION SECURITY SYSTEM ADP-CAN Introduction Motorcar security system ADP-CAN is for motorcars provided with CAN net. It is for the work with the motorcar factory security systems or remote
Calor de Hogar. Av Tecnológico 735, PB. San Salvador Tizatlalli. Metepec, 52172, Edo de México. Teléfono (722) 216 3330 (55) 1163 6038
Calor de Hogar Av Tecnológico 735, PB San Salvador Tizatlalli Metepec, 52172, Edo de México Teléfono (722) 216 3330 (55) 1163 6038 www.calordehogar.com servicio@calordehogar. com [email protected]
INSTALLATION GUIDE. Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930
INSTALLATION GUIDE Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930 Card Reader and Controller Model 3.5 with KIM Swipe Reader Table of Contents 1. Features..................................
MASTER. Water Conditioning Corp. MBA-10/13 FILTERS with the 253/742 Logix Control Valve. Installation and Operation Manual. www.masterwater.
MASTER Water Conditioning Corp. www.masterwater.com Installation and Operation Manual MBA-10/13 FILTERS with the 253/742 Logix Control Valve June 2010 Table of Contents Page No. Topic Description 1 Model
CW-5000/ 5200,1'8675,$/ &+,//(5 86(5 0$18$/
CW-5000/ 5200 Contents Cautions ---------------------------------------------------------------- 3 Parts introduction --------------------------------------------------- 4 Installation ------------------------------------------------------------
Telefon (+45) 43 43 82 00 Telefax (+45) 43 43 74 75 [email protected] www.uni-valve.com. Installation and operating manual
Uni-Valve A /S VENTILER & INSTRUMENTER Telefon (+45) 43 43 82 00 Telefax (+45) 43 43 74 75 [email protected] www.uni-valve.com UNI-EL Electric actuator Installation and operating manual Remote position
REGULINE 600VA / 1000VA REGULATOR USER MANUAL
REGULINE 600VA / 1000VA REGULATOR USER MANUAL TUNÇMATİK REGULINE SERIES AUTOMATIC VOLTAGE REGULATOR Models: REGULINE 600VA / REGULINE 1000VA Principle of Operation Automatic Voltage Regulators regulate
HERZ-Thermal Actuators
HERZ-Thermal Actuators Data Sheet 7708-7990, Issue 1011 Dimensions in mm 1 7710 00 1 7710 01 1 7711 18 1 7710 80 1 7710 81 1 7711 80 1 7711 81 1 7990 00 1 7980 00 1 7708 11 1 7708 10 1 7708 23 1 7709 01
OWNER S MANUAL. Deluxe Demand Water Softeners MODEL NOS. 625.348570 625.348590
OWNER S MANUAL MODEL NOS. 625.348570 625.348590 Caution: Read and Follow All Safety Rules and Operating Instructions Before First Use of This Product. If you have questions when installing, operating or
OS 3030. Instruction Manual. Electronic Controllers for Reverse Osmosis Plants. Software version 0004 2.00
OS 3030 Electronic Controllers for Reverse Osmosis Plants Instruction Manual Software version 0004 2.00 Contents Functional Description...1 PRODUCTION phase...1 Standby phase...1 Rinse after production
ECOAZUR BLUEWATER WATER PURIFICATION PLANTS
ECOAZUR BLUEWATER WATER PURIFICATION PLANTS CONTACT EcoAzur Calle 11a #492 x 60 y 62 Tel: +52-999-920-1972 Col. Residencial Pensiones Email: [email protected] C.P. 97217 Merida, Yucatan, Mexico Website:
Portable Swimming Pool Reverse Osmosis Systems
Portable Swimming Pool Reverse Osmosis Systems C. Brent Cluff, Ph.D. Clean Water Products A standard practice for pool owners is to periodically drain the swimming pool to reduce calcium and magnesium
CDS TROUBLESHOOTING SECTION I. VACUUM. 1.0. Weak vacuum at wand. Gauge reads normal (10hg to 14hg)
CDS TROUBLESHOOTING SECTION I. VACUUM 1.0. Weak vacuum at wand. Gauge reads normal (10hg to 14hg) 1.1. Clogged hoses or wand tube. Disconnect hoses and carefully check for an obstruction. 1.2. Excessive
! WARNING. McDonnell & Miller Installation & Maintenance Instructions MM-217(I) Series 150S and 157S (Snap Switch, All Models except 157S-RB-P)
Series 150S and 157S (Snap Switch, All Models except 157S-RB-P) Low Water Cut-Off/Pump Controllers For Steam Boilers and Other Level Control Applications McDonnell & Miller Installation & Maintenance Instructions
INSTRUCTIONS MANUAL PROLINE PLUS PROLINE PLUS PUMP
INSTRUCTIONS MANUAL PROLINE PLUS PROLINE PLUS PUMP Proline Plus PUMP Proline Plus ECOLOGICAL Control system for lower water consumption. MANUAL FLUSHING VALVE Manual valve for the washing of the membrane.
Testomat AW101 Water Hardness Monitor. A unique water hardness monitoring system with superior performance
Data sheet DS/AW00 EN Rev. D Testomat AW0 Water Hardness Monitor A unique water hardness monitoring system with superior performance Automatic on-line monitoring of residual/total water hardness ideal
Power consumption (kw)
OS Series Series description LIT OS systems are applied to wastewater disinfection. The models of this series were developed on base of high-efficiency low-pressure amalgam lamps and have all components
DC Motor control Reversing
January 2013 DC Motor control Reversing and a "Rotor" which is the rotating part. Basically there are three types of DC Motor available: - Brushed Motor - Brushless Motor - Stepper Motor DC motors Electrical
Autotrol 460i and 460TC Control System
Autotrol 460i and 460TC Control System Installation and Operation Instructions www.pentairaqua.com Contents 460i Electronic Demand System...2 Special Features 460i...2 California Proposition 65 Warning...2
Aqua Rite & Aqua Rite XL Diagnostics Manual
Aqua Rite & Aqua Rite XL Diagnostics Manual Turbo Cell & Control Electronics Software Revision 1.58 Copyright 2011 Hayward Industries Inc. Leave Blank- Inside Front Cover Table of Contents Important safety
Troubleshooting Your RO
Troubleshooting Your RO Summary: There can be many reasons why a RO system suffers a loss in performance, and is unable to produce the proper quantity and/or quality of permeate water. Similar to a doctor
Operating Manual. Rotary Drum Filter. Technology You Can Afford. Quality You Can Trust. Model: KC10 KC15 KC30 KC60
Technology You Can Afford. Quality You Can Trust. Operating Manual Rotary Drum Filter Model: KC10 KC15 KC30 KC60 Koi-Collection Indonesia Tel./Fax: +62-21-82433766 Jl. Raya Parpostel 96 www.koi-collection.com
10/20 COMBINATION UNIT
MASTER Water Conditioning Corp. www.masterwater.com Installation and Operation Manual 10/20 COMBINATION UNIT with the 255/742 Logix Control Valve With Vortech October 2006 Table of Contents Page No. Topic
User s Manual Before using the inverter, you need to read and save the safety instructions.
User s Manual Before using the inverter, you need to read and save the safety instructions. STI SERIES (STI200, STI300, STI500, STI700, STI1000) Power Frequency Pure Sine Wave Inverter The information