CM61 CHRONOTHERM FEATURES PRODUCT SPECIFICATION SHEET

Similar documents
CM702 PROGRAMMABLE THERMOSTAT FEATURES PRODUCT SPECIFICATION SHEET

CM927 WIRELESS PROGRAMMABLE THERMOSTAT FEATURES PRODUCT SPECIFICATION SHEET

DT92 WIRELESS DIGITAL ROOM THERMOSTAT FEATURES PRODUCT SPECIFICATION SHEET

User Manual THR840DUK Digital Thermostat

Drayton Digistat +2RF/+3RF

RDJ10RF/SET. Wireless room temperature controller with 24-hour time switch and LCD. Programmable, for heating systems

CM921 - User Guide. Description. Features. 1 day Wireless Programmable Room Thermostat with LoT technology WHAT IS A PROGRAMMABLE ROOM THERMOSTAT?

Programmable Room Thermostat 7 Day (5-2 Day) Models: / Power Supply: Battery / Mains

Alpha Climatic Programmable Modulating Boiler Energy Manager. Installation and User Instructions

CM927 - User Guide. Description. Features. 7 day Wireless Programmable Room Thermostat with LoT Technology WHAT IS A PROGRAMMABLE ROOM THERMOSTAT?

Drayton Digistat +2RF

Wireless 7 Day Programmable Room Thermostat

Installation Guide. VisionPRO. TH8000 Series. Need Help? This manual covers the following models. System Types

Sensi TM. Wi-Fi Programmable Thermostat MANUAL OPERATION. Version: March Emerson Electric Co. All rights reserved.

COMPUTHERM Q7 Programmable, digital room thermostat. Operating Instructions

Wireless Thermostats 230v and Battery Operated Instruction Manual

SET1E. Installation & User Instructions. Electronic timeswitch for heating & hot water. Certification Mark

TP5000 Si Range Electronic 5/2 day programmable room thermostat Mains, Battery and RF versions Installation and User Instructions

HERZ-Thermal Actuators

Thermostat with display

Installation Guide. Programmable Thermostat TH6220D

TRANSMITTER RECEIVER THESE INSTRUCTIONS APPLY IN THE UK ONLY THESE INSTRUCTIONS ARE TO BE LEFT WITH THE USER OR AT THE APPLIANCE. Digistat Optimiser

PRODUCT PRODUCT CODE TECHNICAL INSTRUCTIONS PAGE

HCE80/HCC80/HCE80R/HCC80R

1F /1/1 Day Programmable. 1F Thermostat Thermostat Configuration Options Heat Pump. Maximum Stages Heat/Cool 2/1

Digital timer thermosatat. isense. Installation and Service Manual AG

Operation Guide 3M-22

FIREDEX Conventional Fire Panels

Installation Guide. LR-HWLV-HVAC TouchPRO Wireless. System Types

RF 1. Contents: Connecting diagram. Detailed information:

ELECTRIC POSITION for electric heat, then confirm with Fan Test below.

its ELECTRIC POSITION for electric heat, or set the units fan control appropriately to ELECTRIC or another appropriate setting.

Install Guide 3M-50. Caution. Caution

RVR Hybrid System Installer Instructions RVR Hybrid System Controller Installation Instructions

AN500T, AN1000, AN1000T, AN1500, AN1500T AN2000, AN2000T

RVL470. Heating Controller. Building Technologies HVAC Products. Series B

ecomax Instructions for use Wall hung room sealed fan assisted condensing boilers For the user

DC1100 & 1400 Energy Controllers. Satchwell DC1100 & DC1400 for energy-efficient temperature control in smaller buildings.

B/S/H/ Error codes and service programmes PH

AIR CONDITIONING SYSTEM 1. FFH SPECIFICATION AIR CONDITIONING SYSTEM RODIUS

TABLE 1: Wiring Terminals. Connect to... 1C 1H 2C 2H 1H1C 2H1C 2H2C 3H2C

How To Control A Thermostat

TICS - Integrated Control Strategy TICS - Total Integrated Control Strategy Mid Range System

APPLICATIONS SPECIFICATIONS CAUTION. Blue Universal Thermostat with Automatic Heat/Cool Changeover Option. Save these instructions for future use!

Installation & User Instructions

ELECTRIC CENTRAL HEATING FLOW BOILER

Installation Guide for Hive Active Heating

Adjustable room thermostat for heating only or cooling only systems

REMOTE CONTROL MANUAL

contents Leading the way in intelligent automation INELS Wireless? Why Click Accessories Complete control

T-100-R Installation Guide

T5000 T000 LCD Digital Fan Coil Thermostat

FAQs. Conserve package. Gateway... 2 Range Extender... 3 Smart Plug... 3 Thermostat... 4 Website... 7 App and Mobile Devices... 7

MAKING MODERN LIVING POSSIBLE. living connect. Installation and User Guide. Danfoss heating

PS42309C INSTRUCTION MANUAL

Mode Switch. Fan Switch Menu button Program button

Install Guide CT100. Caution. Caution ENGLISH. disconnect the power supply before beginning work.

EK908FHL - Thermostat for floor heating

1F Programmable Electronic Digital Heat Pump Thermostat INSTALLATION AND OPERATION INSTRUCTIONS

ABB i-bus KNX Fan Coil Controller FC/S 1.1

evohome Wireless Radiator Zoning Kit Installation & User Guide

Operation 8022C. Customer Support: or Visit our webiste Made In China OFF FAN HEAT COOL AUTO ON

ECL Comfort 110 Application 130. Weather compensated flow temperature control of heating and boiler systems. Instructions

Blue Easy Reader Thermostat 1F95EZ Homeowner s Guide

Electric Flow Boiler

On/off room thermostats range. On/off V30 range. Master/slave PI V200 range. V3000 KNX networked PID range

GETTING STARTED WITH THE MIPOWER MANAGEMENT SYSTEM

RRV934. Multi-controller. Synco living

O. Gas boiler. Gaz 6000 W WBN H-E-N/L-S2400. Operating instructions for the end customer (2014/07) en

OZW30. Central Unit SYNERGYR

Nest Learning Thermostat Installation Guide. Installation step-by-step

Heating Controller. Building Technologies HVAC Products

TC-9102 Series Surface Mount Temperature Controllers

Honeywell CT3500/CT3595 PROGRAMMABLE THERMOSTAT

T7560A,B,C Digital Wall Module

GB/DAS User Instruction

The NEW Greenstar i. intuitive. innovative. improved performance. installation ease

HVAC-32A. Operation Manual. Specifications. Digital Multistage Air Conditioning Controller with inbuilt Outside Air Economy function

Table of Contents. Introduction. Radio Frequency Control. Initial setup Setting the time. Setting the temperature

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CCS. Voltage rating: 115V~60Hz Power rating : 1400W

USER MANUAL WARNING! CONTENTS MODEL 1 SPECIFICATIONS READ ALL INSTRUCTIONS BEFORE PROCEEDING. Non-Programmable Single Stage Heat/Cool Thermostat

TYXIA. * _Rev.1* Installation and User Guide. Wireless receiver. TYXIA RF channel

Smile. The All-In-One Heating Controller

4-Channel Thermometer / Datalogger

Electronic Control Devices The European Product Catalogue 2007

GTEC transfer switch open transition

GSM Alarm System User Manual

BoilerMate SP. benchmark. user instructions A - C L A S S

Overview - Danfoss Link and living software versions

Installation Instructions

TLK 48 MICROPROCESSOR-BASED DIGITAL ELECTRONIC REGULATOR

Electronic Control Devices The European Product Catalogue 2007

Programmable Thermostat MODEL XXX With Dehumidify XXX With Out Dehumidify

ES-LCD User Control SD Card Location

MAKING MODERN LIVING POSSIBLE. living connect. Installation and User Guide. Danfoss Heating Solutions

Laddomat Charging unit

T0118 T2118 T3118. Instruction Manual

T 3 Series VAV Diffusers Analog Diffuser Steel Square Panel Horizontal Pattern Model: T 3 SQ

The Totaline Premier Series of thermostats consists of programmable and non programmable air conditioner, heat pump and thermidistat control.

T6861 Series Large LCD Digital Thermostat 110/220 VAC 2-pipe/4-pipe fan coil control

Transcription:

CM6 CHRONOTHERM PRODUCT SPECIFICATION SHEET The CM6 Chronotherm is designed to provide automatic time and temperature control of heating or cooling systems in villas and apartments. It can be used as part of a system in conjunction with combi boilers, oil- burners and gas fired boilers, circulation pumps, thermal actuators, zone valves and electric heat systems (<8A). The CM6 is designed with the installer in mind and includes a moulded backplate with trunking guides and wiring breakouts to make installation quick and easy. The CM6 display and buttons layout are based on the same simple programming philosophy used on the acclaimed CM4 product. The unit is ideal for consumers who want reliable precise temperature control from a simple to program easy to use product. FEATURES Attractive slim styling makes it ideal for location in any home. 6 daily independent time and temperature level changes let you set 6 time and temperatures pairs to suit your life style. Temporary programmed temperature override to temporarily override the programmed temperature till the next switch point. Holiday button provides energy savings by reducing the temperature for to 99 days when people are on holiday, returning to normal operation (AUTO or MANUAL) on the day of return. EEPROM memory holds the user program indefinitely. OFF mode has an integral fixed frost protection setting at minimum 5 C (installer adjustable) so that pipes in the house will never freeze in winter. 4...30V 8A resistive, 3A inductive SPDT relay provides compatibility with most domestic central heating systems without stocking many different models. Surface or wallbox mounting options, trunking guides and wiring breakouts simplify installation. No installer links or special installer switches on the back of the unit mean no adjustment is required for combi-boilers and most domestic central heating systems. Installer Set-Up Mode allows extra functions to be set at the discretion of the installer to match the consumers applications: Optimisation Pump Exercise Upper / Lower Setpoint Limit Adjust Temperature offset Minimum ON time Cycle rate Heat / Cool Operation Proportional Band Width CM6 has provision for add-on modules to allow the installer to sell additional features during or after the first CM6 installation, giving the installer an additional sale.

CM6 CONTROLS/DISPLAY LAYOUT SPECIFICATIONS Batteries Battery life Battery replacement Switch type Electrical rating Time display Time keeping accuracy Program Time setting resolution : x.5 V IEC LR6 (AA) Alkaline cells : 4 years typical (Duracell MN500) for applications with loads <3A : 3 years typical for electric heat applications (>3A, <8A) : Program retained in EEPROM : SPDT (potential free) : 30 V~, 50...60 Hz, 0.5 A to 8 A resistive 0.5 A to 3 A inductive (0.6 pf) 4 V~, 50...60 Hz, 0.5 A to 8 A resistive 0.5 A to 3 A inductive (0.6 pf) : 4 hour or hour AM/PM format : Typically better than 0 minutes per year : 6 daily time and temperature level changes : Time of day - minute Program - 0 minute steps Sensing element : 00K (@ 5 o C)NTCthermistor Temperature setting range : Program : 5 to 30 o Cin0.5 o Csteps Frost : 5 o C or equal to lower limit (5 o Cto6 o C). Frost protection does not work in cooling mode Temperature control accuracy Room Temperature display range Control form Minimum ON time Cycle rate Wiring : ±0.5 K (nominal) @ 0 o C, 50% load 3K /hour : From 0 o Cto40 o C : P + I (Proportional + Integral) : 0% of cycle time (min one minute), adjustable to to 5 min (see installer set up) : Selectable by application (see installer set up) : Terminal block capable of accepting wiresupto.5mm Wire access : Mains wiring - rear, left or below Low voltage wiring - rear, left or below Dimensions : 30 x 87R(8L) x 9 mm (w x h x d) 30 x 7 x 9 mm (w x h x d) (flap open) Environmental : Operating temperature range 0 to 40 o C Shipping and storage temperature range -0to55 o C Humidity range 0 to 90% rh, noncondensing Approvals : Designed to meet European EN approvals EN60730-(995), EN5504- (997), EN5504- (996)

INSTALLER SET-UP To enter the installer set-up mode : a) Press the OFF button. b) Press and hold INFO i button and press PROG 3,4 together. c) The unit will display the first parameter of installer parameter group category ( from n. to n.5). d) Press TEMP or to change factory setting. The display will flash indicating that a change has been made. e) Press INFO i button to confirm the change. The display will stop flashing. f) Press +or-togotonextparameter. g) Press PROG button to go to Installer parameter group category (from parameter n.6 to parameter n.6). h) To exit installer mode move the slider in MAN or AUTO or OFF position. Installer Set-up Number (Press + or - to change) e.g. = Optimisation Abbreviated Set-Up Description e.g. OP = Optimisation Installer Set-Up Mode Selected In Installer set up we can : Set-up specific applications Enable special features Establish support for Optional Accessories Factory Setting or New Choice Press TEMP or to change e.g. O = Optimisation disabled = Optimisation enabled Specific Applications Setting What do you need to change? Cycle/ Hour Minimum ON time (in minutes) Note : a. To change Cycle/Hour, please go to parameter n. 9 in the installer set-up mode. b. To change Minimum ON Time, please go to parameter n. in the installer set-up mode. Heating Gas Boilers (<30KW) 6 No action required Oil Boiler 3 4. Set Minimum ON Time to 4 minutes.. Set Cycle/Hour to 3. Thermal Actuator Set Cycle/Hour to. Zone valve 6 No action required. Electric heating (for applications <8A). Configure the Chronotherm for electric heating (set parameter n.7 in the installer set up mode to ).. Set Cycle/Hour to. Air conditioning Heat Pump/ Air conditioner. For cooling application only, set the Chronotherm to cooling (set parameter n.6 in the installer set-up mode to 0). For heat/ cool application, set the Chronotherm accordingly to required mode of operation winter = heating summer = cooling by changing parameter n.6 in the installer set-up mode. Explain to the end-user how to implement the change-over. 3 4. Set Minimum ON Time to 4 minutes.. Set Cycle/Hour to 3.

Special Features Description What to do if we wish this feature Optimisation (Variable Start Time) Adaptive Intelligence recovery TM The Chronotherm will adjust the start time in the morning/ afternoon so the desired temperature is reached by the start of the program period e.g. Time 7:00, Temp o C. The Chronotherm will monitor the accuracy of the start up and use this information to modify the calculation for the following day by changing the ramp rate (initial 3 K/hr).The system will restrict the start time to a max of 3 hours. Optimisation will not work in cooling mode. Set parameter. in the installer setup mode to. AM-PM/ 4hr Display Change display format (default 4hr) Set parameter n.3 in the installer set - up mode to. Pump exercise Upper Temperature Limit Lower Temperature Limit Temperature Offset Proportional Band Width When enabled the Pump Exercise will switch the relay on for minute at :00 if the relay has not been switched on since :00 the previous day. While in Holiday mode the Pump Exercise feature, if enabled, will operate. The normal upper temperature limit of 30 o C can be reduced down to o C to save the homeowner energy. Useful if the homeowner rents to tenants. The normal lower temperature limit of 5 o C can be increasedupto6 o C to protect the inhabitants from cold. Useful if the inhabitants include the elderly, children or disabled. If the Chronotherm is located in a hot/cold location and cannot be moved because of wiring then the measured/ displayed temperature can be adjusted by +/- 3 o C. Useful if the homeowner wants the reading to match another appliance temperature display. Can be adjusted up to 3 o C (default is.5 o C) to provide better temperature control (less overshoot). Useful for: a. Well insulated homes with over-sized heating systems b. Air systems with fast response Set parameter n.8 in the installer set - up mode to. Set parameter n. in the installer set -up mode to the desired limit. Set parameter n. in the installer set -up mode to the desired limit. Set parameter n.3 in the installer set -up mode to the desired offset value. Set parameter n.5 in the installer set -up mode to the desired value. Optional Accessories Automatic Time Setting (ATS) Module Description The ATS module picks up a time signal daily from a European transmitter, so you never need to set or adjust the time. What to do if we wish this feature. Fit the ATS module. Set parameter n. 4 in the installer set-up mode to

Parameter Installer Set- Up Number / Abbreviation (Press + or - key to change) Factory Setting Optional Setting Installer Set- Up Category (Press keys PROG or to select) Display Description Display/Setting Description Optimisation :0P 0 Optimisation disabled Optimisation enabled MinimumONTime :0t minuteminimumontime to5 -minutes 3-3 minutes 4-4 minutes 5-5 minutes AM-PM / 4hr Display 3:Cl 0 4 hr clock display hram / PM clock display Accessory Module Type 4:At 0 No accessory module plugged in, - Auto Time Setting Module - Weatherstation Module RESET Time / Temperature Program 5:rP Time / Temperature profile set to factory default Changes to 0 when one of the time/temp profiles are changed 0 Time / Temperature are as programmed To restore the factory profile set to You must now press the PROG key to enter the next section Heat / Cool Operation 6:HC Heating Operation 0 Cooling Operation Electric Heat 7:Eh 0 Applications < 3A Applications 3-8A Pump Exercise 8:PE 0 Pump Exercise Disabled Pump Exercise Enabled Cycle Rate 9:Cr 6 6 cycles per hour (cph) for gas boilers, zone valves and fancoil 3, 9, 3-3 cph 9-9cph - cph Upper Temperature Limit :UL 30 30 C Upper Temp. Limit to 9 C to 9 C adjustment in C steps Lower Temperature Limit :LL 5 5 C Lower Temp. Limit 6 to 6 6 C to 6 C adjustment in C steps Temperature Offset 3:tO 0 No offset -3 to +3-3 C to +3 C adjustment in 0. C steps Pressure Offset (needed for Weatherstation accessory only) 4:PO 0 No offset -99 to +3-99 mbar to +99 mbar adjustment in mbar steps Proportional Band Width 5:Pb.5.5 C Proportional Band.6 to 3.0.6 C to 3.0 C adjustment in 0. C steps Return all Set-Up Features to Factory Settings 6:FS All settings held are the factory defaults. Changes to 0 when one of the parameter values are changed 0 Settings are as modified above To restore the factory profile set to

DIMENSIONS INSTALLATION LOCATION The CM6 Chronotherm is the temperature control element in the heating/cooling system and MUST be located in a position with good air circulation at average room temperature on an inside wall.5 metres above the floor level. Do not position the CM6 Chronotherm near sources of heat (radiators, hot air vents, TV or lights), near doors or windows, or in direct sunlight. MOUNTING The CM6 Chronotherm can be mounted directly on the wall surface or on an electrical wallbox. WIRING The CM6 Chronotherm is designed for fixed wiring only and must be installed in accordance with latest l.e.e. regulations. Ensure the wiring connection to the supply is via a fuse rated at no more than 8 amps and a Class "A" switch (having contact separation of at least 3 mm in all poles). IMPORTANT. The installer must be a trained service engineer. Disconnect the power supply before beginning installation

WIRING ORDERING SPECIFICATION Description Model Logo Literature Spec Sheet -day programmable thermostat T666B008 Honeywell English ENOR 8497 NOTE: The model shown opposite can be ordered as samples to establish the exact customisation requirements. Automatic Time Setting Module Europe Q6667B007 Multi- Language ENOR 850 Honeywell Control Systems Limited Newhouse Industrial Estate Motherwell ML 5SB United Kingdom http://europe.hbc.honeywell.com