QUICK START MANUAL FOR. IDEC - MODBUS Converter

Similar documents
User Manual Revision English

User Manual Revision English

IntesisBox KNX Modbus RTU master

Telephone- and leased line modem for industrial applications TD-36

IntesisBox Modbus Server Fidelio IP

DVPPF02-H2. PROFIBUS DP Slave Communication Module Application Manual

User Manual Revision English Converter / Adapter Ethernet to RS232 / RS485 (Order Code: HD HD M HD HD M)

ZC-24DO CANopen I/O Module: 24 Digital Outputs

Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2

ModBus Server - KNX. Gateway for integration of KNX equipment into Modbus (RTU and TCP) control systems.

IntesisBox KNX Modbus TCP master

IntesisBox ASCII Server - LON

PCS0100en Persy Control Services B.V. Netherlands

Modbus Server SAMSUNG Air Conditioners

User Manual Revision English

Universal Serial Bus (USB) to DH-485 Interface Converter

PLC training panel (Twido version)

ADACSNET USB Control Module

1 Serial RS232 to Ethernet Adapter Installation Guide

Rack mounted telephone- and leased line modem for industrial applications

IntesisBox Modbus Server SAMSUNG Air Conditioners

Application/Connection Examples

Omron I/O Driver (Series 2) Programmable Serial Interface Card

Options for ABB drives, converters and inverters. User s manual FDPI-02 diagnostics and panel interface

User Manual Revision English

Application Note: Modbus/RS485 Wiring for Conext Core XC Series Inverters

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC A - M8 connector

TX OPEN RS232/485 module

IntesisBox KNX - LON

USB-to-Data Highway Plus Cable

NC-12 Modbus Application

The Answer to the 14 Most Frequently Asked Modbus Questions

User Manual Revision English

IntesisBox KNX LG Air Conditioning

SEC 4100 SYSTEM MONITOR Programmable Serial Interface Card Series 2

Technical Note A007 Modbus Gateway Vantage Pro2 25/09/2009 Rev. A 1 de 7

ENET-710. ENET Ethernet Module ENET-710 JAN / 06 FOUNDATION

TCP/IP MODULE CA-ETHR-A INSTALLATION MANUAL

User Manual Revision English

CMC-DN01 DeviceNet Slave Communication Card Operation Manual

User Manual Revision English

OPT SERIAL TO FIBER OPTIC CONVERTER

ABB Drives. User s Manual. Pulse Encoder Interface Module RTAC-01

Bluetooth HC-06 with serial port module Easy guide

Industrial RS-232/ RS-422/ RS-485 over Ethernet Media Converter

INTELLIGENT CONTROL MODULE SA-2000-II HARDWARE MANUAL. Access Technologies International, Inc.

BIT COMMANDER. Serial RS232 / RS485 to Ethernet Converter

CMC-PD01 PROFIBUS DP Slave Communication Card Operation Manual

L5354 ControlNet Communications Interface

MicroTech II McQuay Maverick II Rooftop Unit Controller BACnet Communication Module (MS/TP)

MDM192 MULTI-DROPS DIGITAL MODEM FOR PRIVATE LINE. USER GUIDE Document reference :

User Manual Revision English

EDI Distributor Control Interface Wiring and Setup Instructions

IntesisBox. KNX SAMSUNG Air Conditioning. Gateway for integration of Samsung air conditioners into KNX control systems. RS485.

INTMOD485-LH Protocol Converter

1. SAFETY INFORMATION

Advanced Data Capture and Control Systems

User Manual Revision English

User Manual Revision English

Bluetooth UART/RS232 Module

User Manual IC-485AI

EGCP-3 LS Revision L. Explanation of Software Changes Made for the EGCP-3 LS Control. Application Note 51294

User Manual Revision English

Installation manual. Generator Paralleling Controller GPC multi-line C

ELCOMPONENT LTD. User Manual

User Manual Revision English

Programming Flash Microcontrollers through the Controller Area Network (CAN) Interface

DAM Series DAM124 4DIN+8AI+4DO Module Model No.:DAM124 WebSite:

Moxa TCC-100/100I User s Guide

Bluetooth to Serial Adapter

Waveguide Access Point WGA631. Product Guide

How to read this guide

EGCP-3 MC Revision H Software Revision F. Explanation of Software Changes Made for the EGCP-3 MC Control. Application Note 51298

Mini-HDMI Series MINIATURE MULTIMODE FIBER OPTIC HDMI TRANSMISSION SYSTEM

User Manual Revision English

Series AMEPR30-AZ up to 2.5A AC-DC / DC-DC LED Driver / Converter

CAUTION! THE 7I29 USES VOLTAGE AND POWER LEVELS THAT REPRESENT A HAZARD TO LIFE AND LIMB.

with Electronic Assistant

MLC TM Maximum Productivity and Versatility for Control without Compromise!

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

CAT AVR V2.3. Instruction Manual. Voltage regulator for generators. March 2008

User Manual Revision English

s!nus-elektrotechnikai bt. Industrial IT & Automation

PCMCIA 1 Port RS EDITION OCTOBER 1999

GV-Data Capture V3 Series User's Manual

Programming and Using the Courier V.Everything Modem for Remote Operation of DDF6000

PowerLogic Sub Meter Display (SMD and SMDOPN)

IntesisBox Modbus Server - Mitsubishi Electric G50

Install the DeviceNet Module using the following procedure:

Flarm LED indicator. Version 1.1

Temp-485-Pt100. A temperature sensor (Pt100 or Pt1000) communicating over the RS-485 bus with a simple communication protocol

How To Operate Loader On A Microsoft Powerbook 2.5 (Powerbook) With A Powerbee 2.2 (Powerbee) And Powerbee 3.5 Powerbee (Powerbore) (Powerboard) (Operating

PRO370D 65A Mbus MID DIN rail three phase four wire energy meter. User manual Version 1.03

Congratulations! Thank you!

L Firmware And FPGA Configuration Upgrade

Whale 3. User Manual and Installation Guide. DC Servo drive. Contents. 1. Safety, policy and warranty Safety notes Policy Warranty.

Kvaser Mini PCI Express User s Guide

DUAL%CHANNEL BROADBAND%LINEAR%AMPLIFIER Model&A800D

ATS Communication Overview

RIGtalk. Revision 5. Owner s Manual 2012.

Transcription:

QUICK START MANUAL FOR IDEC - MODBUS Converter 1

Preliminary Thank you for purchasing Idec-Modbus Converter product from IDEC. Idec- Modbus Converter Product is versatile protocol converter / Data sharer with Windows based configuration Software. This manual will help you to safely install, configure and operate Idec-Modbus Converter Products. All the safety warnings and precautions must be followed to ensure proper unit performance and personal safety. Warnings used in this manual: DANGER Danger Warnings are used to indicate situations, locations and conditions that can cause serious injury or death. CAUTION Caution Warnings are used to indicate situations and conditions that can cause operator injury and/or unit damage IMPORTANT Idec-Modbus Converter Series Products are intended to be protocol converters / Data sharer device, to work with PLCs, Inverters or any device having serial port with any protocol. Which actually allows sharing data between different devices with different or similar communication protocols. Also it can take control actions on request of device being connected. It is assumed that the user is well acquainted with the PLCs / Inverters / Controllers being used. Any mechanical or electrical modification to this unit will void all warranties. We hope that you find this manual informative. If additional information or technical assistance is needed please contact: IDEC Corporation 75 Elko Drive, Sunnyvale, CA 94089 Tel : 1-800-262-4332 Fax :1-800-635-6246 Web : www.idec.com 2

Manual Revisions: If you contact us in reference to this manual, please include the following revision number Name : Idec-Modbus Converter Operation Manual Revision : QMAN\GWY\1001\Rev0 3

Table of Contents Preliminary... Contents... i ii 1.0 Introduction... 1-1 1.1 Purpose of this manual... 1-1 1.2 Introduction to Idec-Modbus Converter... 1-1 1.3 Idec-Modbus Converter Specifications... 1-2 2.0 Hardware... 2-1 2.1 Mounting... 2-1 2.2 Power Requirements... 2-2 2.3 Communication Ports... 2-3 3.0 Getting Started... 3-1 3.1 Introduction... 3-1 3.2 Project Devices, Reg. Address and Blocks. 3-1 3.3 Device Communications... 3-2 4.0 Understanding Idec-Modbus Converter Features 4.1 Repeat Cycle... 4-1 4.2 Control Word... 4-3 4.3 Error Indication Bit... 4-5 4.4 Selectable Baud rate... 4-7 4.5 LEDs for Communication Status 4-8 5.0 Configuration Software... 5-1 6.0 How Do I Start?... 6-1 4

Introduction In this chapter.... Purpose of this Manual Introduction to Idec-Modbus Converter Idec-Modbus Converter Specifications 5

1.1 Purpose of this Manual The intention of this Operation Manual is to provide a guide for Safe installation, Configuration and operation of Idec-Modbus Converter series models. Read this operation manual thoroughly before installing and operating Idec-Modbus Converter. This document is based on information available at the time of its publication. While efforts have been made to be accurate, the information in this document may not cover all the details or variations in hardware or software. Features described herein may not be present in all hardware. IDEC reserves the right to update information in this publication without prior notice. 1.2 Introduction to Idec-Modbus Converter Idec-Modbus Converter Series protocol converters provide interface between different devices having different or same communication protocol. Idec-Modbus Converter communicates with your PLCs / Inverters / Controllers using RS-232 or RS485 serial communication. This unit takes power from PLC on their PLC port. Configuration of Idec-Modbus Converter : Each Idec-Modbus Converter has to be configured using Windows based configuration Software before connecting it to the PLC. 6

Normal Operation: IDEC Side MODBUS Side I I Connect correct Idec-Modbus Converter to PLC cables on both communication ports and your Idec-Modbus Converter is running. 7

Application: IDEC PLC Modbus slave Devices in multidropping mode. A B Modbus slave Node 1 Modbus slave Node 2 Modbus slave Node 3 Modbus slave Node 31 8

1.3 Idec-Modbus Converter Specifications Power Supply : 24 VDC +/- 5 % (50 ma MAX.) No Fuse inside. 5 VDC +/- 5 % FROM PLC (75 ma MAX.) Communication : Two ports as follows: Com 1: RS 232C For configuration and PLC communication Com 2: RS 485 For Modbus PLC communication Indications : IDEC STATUS LED MODBUS Temperature : Operating: 0 to 60 C Storage: - 40 to 90 C Humidity : 10% to 90% (Non condensing) Immunity to ESD : Level 3 as per IEC1000-4-2 Immunity to Transients : Level 3 as per IEC1000-4-4 Radiated Susceptibility : Level 3 as per IEC1000-4-3 Emissions : EN550 CISPR A Dimensions : 97mm(W) X 15.mm (H) X 42mm(D) (DIN RAIL mounting) 9

Hardware In This Chapter... Mounting, Panel Cutouts Power Requirements Communication ports 10

2.1 Mounting

2.2 Power Requirements Idec-Modbus Converter is DC powered. Power is supplied from the PLC port cable and the supply voltage range is +5VDC + 5%. Make sure to check PLC power before connecting cable to Idec-Modbus Converter. Please note that, Idec-Modbus Converter is not Fused internally. Fuse should be connected from outside wherever required. All the Idec-Modbus products are housed in a molded ABS plastic case which eliminates any electrical shock hazard. Hence Safety Earth is not required to be connected to the chassis of the unit. The DC ground is not directly coupled to Earth ground internally. The unit is designed to operate properly whether or not the DC ground is connected to the Earth ground. We do recommend, however, that if the DC ground has to be connected to the Earth ground, the Earth connection should be made to a central star point as poor site earths can introduce noise into a system. Do not power Idec-Modbus and inductive loads with the same power supply even though there is enough immunity in the Idec-Modbus to withstand the transients present on these lines. Avoid using power supplies with large capacitive outputs, which may cause problems if power is cycled within a short time period. If wiring is to be exposed to lightening or surges, use appropriate surge suppression devices. Keep AC, high energy and rapidly switching DC wiring separate from signal wires. Connecting high voltages or AC power mains to the DC input will make Idec-Modbus unusable and may create an electrical shock hazard to personnel. Such a failure or shock could result in serious personal injury, loss of life and/or equipment damage. DC voltage sources should provide proper isolation from main AC power and similar hazards.

2.3 Communication ports Each Idec-Modbus Converter unit has two communication ports. Description of each is given in following topics. Com port1: This port is RS232C port and is used for configuration of Idec-Modbus Converter. Same port can be used for PLC communication after proper configuration. This port is used to download the firmware, Drivers and / or Project in to the Idec-Modbus Converter unit. As the same port is used for PLC communication, when Idec-Modbus Converter is communicating with a PC for programming, PLC operations are suspended. Pin description of this Port is given below: 9 5 Signal Ground Dir / Open Collector Out Receive / Data in (RS232C) Transmit / Data out (RS232C) 6 1 Com port2: +5 VDC In from PLC This port is RS232C or RS485 (2 wire) depending upon ordering information and is used for PLC communication.

[II] For Idec-Modbus Converter i) RS232C 3 2 1 SIGNAL GROUND RD SD ii) RS485 3 2 1 SIGNAL GROUND B A

Getting Started In this chapter... Introduction Project Devices, Register Address and Blocks, Device communication

3.1 Introduction Idec-Modbus Converter is a Protocol Converter / Data sharer for devices like PLCs, inverters, Controllers. Idec-Modbus Converter has two serial ports that connect with two different devices. These devices share data between themselves through Idec-Modbus Converter. Idec-Modbus Converter communicates with a device to get the information required by the device connected on the other port. The device that requires data is called Destination Device and the device that provides data is call Source Device. Information could be the value of a PLC register or the status of a PLC coil or Command from Source Device to Destination Device. Data flow through Idec- Modbus Converter, which is controlled by the project, can be unidirectional as well as bi-directional. 3.2 Project PLCs, Register Address, Blocks, Microsoft Windows based configuration software, Idec-Modbus Converter Setup, helps user to configure Idec-Modbus Converter unit. `Configuration' means making the Idec-Modbus Converter unit work as per the system requirements. For example, Idec-Modbus Converter can be configured to transfer data between two devices by execution of blocks. The complete configuration for a unit is termed as `Project'. Project comprises of device names, Register addresses, Conditions for block execution etc. Each register in a device memory has a unique address and this address can be directly used in Idec-Modbus Converter project. Each action to be taken by Idec-Modbus Converter, which is configured in a Project, is known as a Block. Block may contain information like, copy number of Words, Bits etc from Source device to Destination device. After the Project is defined, Drivers for defined devices and Project should be downloaded. Idec-Modbus Converter now communicates with the connected devices and transfers data between them. 3.3 Device communication Idec-Modbus Converter can communicate with any device without any change in the Idec-Modbus Converter hardware. To communicate with a device, Idec- Modbus Converter needs: 1. Communication Drivers for the devices

2. Idec-Modbus Converter IBM PC communication cable for Configuration 3. Idec-Modbus Converter - device communication cables 1. Communication Drivers for the devices: Each device has a pre-defined protocol for communication. Communication driver varies from device to device. Idec-Modbus Converter requires two drivers for communication, as two devices are connected for data sharing. These Communication Drivers are downloaded in to Idec-Modbus Converter. These drivers enable Idec-Modbus Converter to talk with devices. 2. Idec-Modbus Converter IBM PC communication cable for Configuration: For Idec-Modbus Converter to communicate properly with external Device, It should be configure for that device as per system requirement. For downloading Configuration/project, drivers, etc., Idec-Modbus Converter needs on Configuration cable (IBM Cable). Pin-outs for that cable are as follows. DB9 (Male) DB9 (Female) for IBM-PC +5 VDC 2--------------------------------------------------2 3--------------------------------------------------3 5--------------------------------------------------5 6 -- +5 VDC 3. Idec-Modbus Converter - device Communication Cable: Proper Idec-Modbus Converter - device cable is required for error free communication with any device.

Idec-Modbus Converter Features In this chapter... Repeat Cycle Control Word Error Indication Bit Selectable Baud rate LEDs for Communication Status

4.1 Repeat Cycle User can control Block execution by using Repeat Cycle. Priority of Block execution is decided by means of Repeat Cycle. Range for Repeat Cycle is 1-99. Repeat Cycle = 1 Highest priority Repeat Cycle =99 Lowest priority Normally, Blocks are executes in step by step fashion. Eg. If 5 Blocks are defined a in project with Repeat cycle = 1, then Idec-Modbus Converter executes blocks in following fashion. Block execution starts with Block#01, then Block#02, Block#5 and again Block#01 Block#01 Block#02 Block#03 Block#04 Block#05 Execution of all the Blocks from Block#01 to Block#05 is treated as one cycle. In above example 1. If Repeat Cycle =1 for every block except Block#04 which has Repeat Cycle =03 All the Blocks will be executed once after power-up. Block#04 will be skipped for next 2 cycles. Repeat Cycle 1 means Block will be skipped for 0 cycle means No skipping. Repeat Cycle 2 means Block will be skipped for 1 cycles. Repeat Cycle 3 means Block will be skipped for 2 cycles.

4.2 Control Word This is explained below. 1. In first cycle all blocks will be executed. Block#01,02,03,04,05 2. In 2nd cycle only 4 blocks will be executed.block#01,02,03,05 3. In 3rd cycle only 4 blocks will be executed. Block#01,02,03,,05 4. In 4th cycle all blocks will be executed. Block#01,02,03,04,05 5. In 5 th cycle only 4 blocks will be executed.block#01,02,03,05 6. In 6th cycle only 4 blocks will be executed. Block#01,02,03,,05 7. In 7th cycle all blocks will be executed. Block#01,02,03,04,05 Another way of controlling Block execution is use of Control Word. This feature is extremely useful for small applications where less than 17 blocks are required. Control Word can be enable or disable while configuration of Idec-Modbus Converter using Configuration Software. Normally Control Word is disable. It can enable just by clicking on check box in setup software. Control Word can be chosen from any of the Device connected. When Control Word is disable Block execution is totally control by Repeat Cycle. But Repeat Cycle can only decides priority. Blocks, which are more important for process has to be, assigned high priority and those, which are less important for process has to be, assigned low priority. When Control Word is enable Block execution is controlled using discrete bits of that word, Bit0 in control word controls execution of Block 1 Bit1 in control word controls execution of Block 2 Bit2 in control word controls execution of Block 3 Bit3 in control word controls execution of Block 4 Bit4 in control word controls execution of Block 5....

Bit15 in control word controls execution of Block 16 Bit = OFF will stop execution of block Bit = ON will enable execution of block This feature allows user to execute block in Idec-Modbus Converter whenever required, from outside. This avoids unnecessary execution of block and results in improvement of speed. 4.3 Error Indication Bit This feature enables user to detect communication break, wire faults, Device power fail etc. at both ends of Idec-Modbus Converter. This is physical bit present in external device connected to Idec-Modbus Converter. Fault at com1 end is reported to com2 Device and fault at com2 end is reported to com1 Device by setting the bit in external device (Idec-Modbus Converter sets this bit when error occurs). Error indication bit can be enable or disable while configuration of Idec-Modbus Converter using Configuration Software. Normally Error indication bit is disable. It can enable just by clicking on check box in setup software. Error indication bit can be enabled or disable in any of the Device connected to Idec-Modbus Converter. Normally this bit is OFF, in case of abnormality in communication. This bit is set to ON by Idec-Modbus Converter, so that external device can know the problem. This useful to operator to take necessary action and avoid production losses. 4.4 Selectable Communication Parameters Normally Idec-Modbus Converter communicates with external devices with there default Communication Parameters. Selectable Communication Parameters for Communication Ports is very useful feature in Idec-Modbus Converter, which allows user to change Baud rate, no. of stop bits, Parity etc. at any time without downloading Driver for that particular Device. Once you downloaded the driver for the external Device, you can change Communication Parameter, just by selecting new communication parameters and downloading the same project. 4.5 LEDs for Communication Status Idec-Modbus Converter has 3 LEDs on topside, which are useful for user to see communication status and Idec-Modbus Converter mode.

IDEC LED Blinking of this LED indicates Communication is happening with IDEC Device. If IDEC LED is not blinking then it indicates that, IDEC Device is not responding, no power to IDEC Device or Communication Cable Fault. This may also happen in case of invalid baud rate or Communication Parameters. OK LED When Configuration Cable is connected, and power is applied to Idec-Modbus Converter, this led will blink at fast rate, indicates that Idec-Modbus Converter is ready for configuration. When proper PLC-Idec-Modbus Converter Cable is connected and power is applied to Idec-Modbus Converter, and if external Device is not responding or power is not applied to external Device or Communication cable is faulty, then this LED will blink at slow rate. This LED will light on steady, when proper communication happens between Idec-Modbus Converter and external Device. MODBUS LED Slow blinking of this LED indicates Idec-Modbus Converter is trying to Communicate with MODBUS Device and device is not responding, no power to MODBUS Device or Communication Cable Fault. This may also happen in case of invalid baud rate or Communication Parameters. Fast blinking indicates that, Communication is happening with MODBUS Device.

Configuration Software Each Idec-Modbus Converter has to be configured using Windows based configuration Software before connecting it to the PLC. Configuration includes. 1. Create a new project Select protocols both communication ports of Idec-Modbus Converter. Create a blocks for data to be shared. Set Communication Parameters. Set Control Word. Set Error Indication Bit, etc. 2. Downloading. Download Project Download new firmware if required (For upgradation ) Download new drivers (For different protocols) If Devices to be connected to IDEC-MODBUS CONVERTER are specified while ordering, Downloading firmware and drivers is not needed. Firmware & drivers are already downloaded while shipment. 3. Upload Project. Existing project in the Idec-Modbus Converter module can be seen. 4. Upload System Data. This option enable user to see versions and status of firmware, drivers, and boot block. How Do I Start? User should follow the given sequence to configure and use any Idec-Modbus Converter unit. 1. Install IDEC-MODBUS CONVERTER Setup Software. 2. Create Idec-Modbus Converter Project. 3. Connect IBM cable and power. 4. Download project in Idec-Modbus Converter unit. 5. Now connect correct cables between external devices(plcs, inverters etc.) and Idec-Modbus Converter.