AGP PELLET STOVE & INSERT

Similar documents
STOVES & INSERTS PELLET. PELLET STOVES & INSERTS. woo

Boston, Venice, Kodiak. Enviro Wood Fireplace Inserts

Across America. Wood & Coal Brochure

The Savannah Steel Series Wood Burning Stoves and Inserts

Installation Instructions

Wood Burning Stoves & Inserts

GAS STOVES woo GAS STOVES

Gas Stoves. H15-10 Direct Vent Gas Stove. Model H15-NG10 H15-LP10. Approved Venting Systems

PRE-ASSEMBLED INSTALLATION INSTRUCTIONS FOR PACB SERIES COAL FIRED OVENS

GNOME PELLET E.I. Pellet Heater Owner's Manual Installation and Operating Instructions. Please read this entire manual before installation.

High efficiency, cast-iron gas boiler

(This report is endorsed) Industrivej 20, 9900 Frederikshavn, Danmark

Ravelli Camino Insert Wood Pellet Burning Heater. Wood Pellet Fire Installation Specifications. Safety testing of the

Fireplace Xtrordinair Electric Fireplace Inserts

HOW MUCH FUEL DOES A GAS STOVE CONSUME AND HOW MUCH DOES IT COST TO OPERATE?

A new range of clean burning multifuel stoves

BIOHOUSING Seminar Success stories of biomass heating in small scale

The growing popularity of Gas Fireplaces has created a demand for an ever increasing array of styles and sizes to fit every decor and budget.

SPECIFICATION & INSTALLATION GUIDE FOR MASPORT LE4000 PROVINCIAL INSERT FIRE, NEW ZEALAND MODEL

COMMERCIAL COOKING HOODS, VENTILATION & FIRE SUPPRESSION SYSTEM GUIDELINES AND PROCEDURES

Bath Planning Guidelines With Access Standards

EVOLUTION PELLET STOVE

Residential/Commercial Gas Condensing High Efficiency Tankless Water Heaters

Commercial Gas Water Heaters

EF3 Freestanding, Fireplace Insert, and Built-In Heater OWNER S & TECHNICAL MANUAL

INSTALLATION AND OPERATION MANUAL

ASX7-4-IOM-7 J

PART 6: VENTING, COMBUSTION AIR & CONDENSATE REMOVAL

Gas Unit Heaters Duct Furnaces Horizontal - 60 HZ Form No. LF (10/2011) LF24 Standard

$ Blower Kit Rear Heat Shield Kit $ Spark Screen Kit $ Outside Air Kit $59.

FREESTANDING CLEAN AIR WOODBURNER

THIS BOOK CONTAINS IMPORTANT INFORMATION. PLEASE KEEP IT IN A SAFE PLACE FOR FUTURE REFERENCE.

CROWN BOILER COMPANY BWF SERIES BOILER CATEGORY I VENT KIT INSTALLATION AND OPERATING INSTRUCTIONS

INSTALLATION AND OPERATIONS GUIDE FOR GRAND CANYON GAS LOG SYSTEMS

SWIMMING POOL, SPA, & HOT TUB GUIDELINES

ELECTRIC I FIRES. CW036_Electric_brochure_art.indd 1

Handcrafted with passion

Gas-Fired, Residential Storage Type Water Heaters

AVR Pellet Control Board Installation/Service Instructions

One Year Warranty. Stock U.S. # of Volts Weight CONN. Height Dia. Watts # GAL. Elements INS. Inches NATURAL GAS* Six Year Warranty

Commercial Gas Furnace Upflow

Subpart 1. Installation. All plumbing systems must be. installed and tested according to this chapter and chapter 4715,

Figure 22: Typical Individual Venting. Figure 21: Single Water Heater Venting

556/586 NEW NEW. One step closer to the fire.


CHIMNEYS AND FIREPLACES

TFL CUSTOM FIREPLACES WITH MASONRY BRICK LININGS. standard INSTALLATION SPECIFICATION INTO TIMBER FRAMING

Gas Meter Clearances and Service Installation Requirements

USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR

B u y e r s Guide Natural Gas Hearth Pro d u c t s

Troubleshooting Draft Problems in Chimneys

780 CMR CHIMNEYS, FIREPLACES AND SOLID FUEL-BURNING APPLIANCES

Originators of the Flexible Water Tube design

Gas Fireplaces FEATURING

HEAT WAVE DUCT KIT KIT #

NOTE! READ INSTRUCTIONS FULLY BEFORE INSTALLING OR OPERATING.

HEAVY DUTY STORAGE GAS

M7RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. High Efficiency / Direct Vent Condensing Downflow Gas Furnace

WOOD HEAT TECHNIQUES TACTICS & TIPS

King/Ashley Pellet Stove

DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS

Wood Burning Safety Guide

SRP Pricelist 2015 Including VAT. Stoves for every home

Gas Meter Clearances and Service Installation Requirements

BUILDING INSPECTORS INSPECTION FORM FOR CHILD CARE CENTERS

Arapahoe County Residential Water Heater Installation and Inspection Guide

Frequently Asked Questions. Air Top Diesel Heaters. 2000STC, Evo 40 & Evo 55

Excerpts from the Canadian National Building Code (NBC)

IMPORTANT SAFETY INSTRUCTIONS WARNING READ AND SAVE THESE OPERATING AND SAFETY INSTRUCTIONS BEFORE USING THIS HEATER.

Convection Ovens. BX Classic. Models BX4 / FG 189C, BX / FG 158C, BX10 / FG 180C. Operator's Manual

King / Princess BLAZE KING. King / Princess. Free Standing Wood Stoves.

This handout is a guide only and does not contain all of the requirements of the Minnesota State Building Code or city ordinances.

Series GM. Peerless Boilers. Residential/Commercial Gas Boilers

INSERTS GAS FIREPLACE. GAS FIREPLACE INSERTS

Cooling Capacity CFM in. w.c. (125 Pa)

REQUIREMENT 5. Light Switches, Electrical Outlets, Thermostats, and Other Environmental Controls in Accessible Locations

DRYER VENTING SPECIFICATIONS DRYER SAFETY

MAJESTIC. OUTDOOR / INDOOR WOOD FIREPLACES Model: ODSR36A OWNERS INSTALLATION & OPERATING INSTRUCTIONS. KEEP THESE INSTRUCTIONS FOR FUTURE REFERANCE.

Ceramic Glass Electric Galley Ranges

HIGH QUALITY COMPONENTS

American Fireglass Outdoor Fire pit kit information. General instructions/warnings for outdoor gas pan and burner systems

the stainless steel water-heater for your woodstove USER S MANUAL

CHAPTER 5 WATER HEATERS

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM

IMPORTANT INSTRUCTIONS & OPERATING MANUAL. Houston 50 Inch Electric Wall Mounted Fireplace Black / White

TECHNICAL GUIDE 95.5% SINGLE STAGE GAS-FIRED RESIDENTIAL MULTI-POSITION GAS FURNACES MODELS: TG9S DESCRIPTION FEATURES

Residential Deck Safety, Construction, and Repair

Wood Pellet Stove 101

flueless gas fires & stoves

Model (E.P.A. Phase II Approved)

Hardwood vs. Softwood

Assembly Instructions MDM Products Party Tent

DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS

CORNER FRIDGE REFRIGERATION UNIT INSTALLATION AND OPERATION INSTRUCTIONS

Exhaust Calculation Booklet

AZB 800. Vertical Flue Gas Ducting Ø60/100mm

FOXAIR 60/50 ALL MODELS

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CCS. Voltage rating: 115V~60Hz Power rating : 1400W

ELECTRIC CENTRAL HEATING FLOW BOILER

High Efficiency Copper Finned Tube Boilers 750,000-2,000,000 BTU/HR

Transcription:

AGP PELLET STOVE & INSERT

EPA Ceritfied Only 0.66 Grams/Hour

Easy to operate...easy to live with...easy to own! Why do we call it the AGP? The Avalon AGP freestanding stove and insert offer all the benefits of wood heating plus fuel that is clean, compact and easy to use. The pellets are made from all-natural wood by-products that are safe for the environment and are a renewable resource. The AGP appliances are designed to efficiently burn ALL GRADES of wood pellets to produce a quick, convenient heat. You can operate these pellet appliances with either a simple manual process, the wall thermostat to maintain your desired room temperature, or the remote control to program the room temperature and shut-off time. The AGP freestanding stove and insert are both EPA Certified and extremely clean burning. Emissions:* Stove - 0.67 Grams/Hr. and Insert - 0.66 Grams/Hr. Efficiency:** 78% *Emissions number was achieved using the EPA method 5-G and 28A. **Both AGP appliances were not tested for efficiency. The 78% value is a default efficiency applied by the EPA to non-catalytic pellet heaters. The AGP appliances are designed to be efficient home heaters. Both the stove and insert can heat from 800 to 2,000 square feet. The AGP stove features a huge 80 pound hopper capacity that when fully loaded with the burn rate set to low, you can expect up to 57 hours of continuous heat without refueling. The AGP insert has the ability to fit into virtually any fireplace opening, big or small. It features an adjustable hopper that allows the hopper capacity to be maximized, based on the size of the firebox. 40-70 pounds of pellets can be loaded into the hopper, depending on the adjusted size. With a full hopper and low burn rate, experience up to 28-50 hours of continuous heat without having to reload your hopper. The AGP stove and insert use high grades of 304 and 309 stainless steel in areas of the firebox where the combustion intensifies at its highest. Even the firebacks are made from stainless steel, not ceramic or aluminum. The AGP appliances are engineered with quality throughout for excellent daily performance and long-life reliability, and they are backed by our Real World Seven Year Warranty. Easy to live with! Just fill the hopper and walk away almost. With any pellet appliance there are things you need to do in order to keep them running. By cleaning your pellet stove or insert you will burn less pellets and get the maximum heat output, saving you money. The Avalon AGP appliances do most of the basic maintenance for you. Monthly and annual maintenance is simple and requires no special tools. The complete system can be cleaned in a matter of minutes. State-of-the-art control panel Your pellet appliance operation is controlled by an easy to understand control board. 6 Seven control functions and features: 1. Start Button Starts the appliance 2. Stop Button Stops the appliance 3. Heat Control Adjusts the heat output from low to high. 1.4 lbs 5 lbs per hour 4. Fan Control* Adjusts the room air fan to move air through the appliance and into the home. 5. Thermostat Allows the appliance to be controlled by a remote thermostat. 6. LED Light Illuminates panel for easy reading of controls 7. System Fuse Easy access to replace fuse if needed 2 5 1 3 4 *You can make it even easier by combining the heat and fan functions to operate together. Simply turn the fan control all the way to the left until the BLUE Auto Fan light illuminates. Watch the AGP Homeowner s Video. 7

AGP Pellet Stove EPA Certified Only 0.67 Grams/Hour Optional Stainless Steel Side Panels The AGP appliances offer optional lightly brushed Stainless Steel Side Panels - an easy way to customize the look of your AGP stove or insert in just minutes!

AGP Stove & Insert Features Horizontal Rotary Disc (HRD) HRD feed system features case hardened cutting blade to cut through the toughest pellets! Stainless Steel Burn Platform The heart of the AGP system is the Horizontal Rotary Disc (HRD). Its purpose is twofold; (1) It controls the amount of fuel that leaves the hopper and enters the auger. (2) No direct path between the burning fuel, the auger and the hopper, eliminating any chance there is of burn back. The Horizontal auger moves the fuel from the drop zone to the inclined platform. By being horizontal it offers two distinct advantages; Watch a video on how the HRD feed system works! (1) Along with the pellets it moves the pellet fines onto the burn platform to be burned instead of causing a potential maintenance issue - more heat, less waste (2) Less stress on auger motor - longer life with years of smooth, quiet operation Burn Platform This is where intense combustion occurs. The burn platform is made of long-life high-grade 309 stainless steel and is 3/16 thick. The inclined floor of the burn platform is at a 14 degree angle and is self-tuned to burn the fuel completely and still maintain its self-cleaning benefit. As new fuel enters the platform, ash and particulate matter is pushed into the ashpan for easy removal as routine maintenance dictates. Because these units are self-cleaning, you are rarely required to remove any unburned clinkers. A burn platform clean-out tool is provided if you ever need to clean the platform surface. Optional Thermostat and Remote The AGP appliances feature GreenSmart technology allows you to automatically adjust the flame and heat output by up to 72%. This feature is designed to give you the ability to operate your pellet stove or insert with multiple thermostat systems. Air Tube Scraper Tool Easy To Maintain Hopper Capacity Stove 80 lbs. Insert (adjustable) 40 to 70 lbs. Heating Capacity* 800 to 2,000 Sq. Ft. Remote Control Wall Thermostat The GreenSmart thermostat system allows you to customize the control board to adjust the heat output once the room reaches a desired setting. You can select from 3 different pre-set sequences to use less fuel and reduce heat swings for a more balanced heat output. The best part is it s just the push of two buttons to accomplish this and can be set by your installer or if you prefer, you can do it yourself. The instructions are easy to understand and can be found in the Owner s Manual and Home Owner s DVD. Burn Times* On Low Stove Up to 57 Hrs. Insert up to 50 Hrs. Turn Down Ratio* Btu/Hour Range* Burn Rate Per Hour* Glass Area 72% Low -11,480 1.4 lbs. on Low 321 Sq. In. High - 41,000 5 lbs. on High * HEATING CAPACITY may vary depending on the degree of home insulation, floor plan and ambient temperature zone of the area in which you live. BTU/Hour range, Turn down ratio and burn times will vary with the quality, size and brand of pellets used.

AGP Stove & Insert Features 1. 80 lbs. Capacity Hopper (Stove only) 2. Horizontal Rotary Disk (HRD) Feed with Case Hardened, Replaceable Shear Blade 3. NEW Drive Motor for HRD - 45% stronger motor to slice through the toughest pellets, quietly and efficiently! 4. Pellet Holding Chamber 5. Fire Chamber 6. Primary Fuel Feed Auger 7. Drive Motor for Auger 8. Stainless Steel Burn Platform 9. Ash Pan 10. Combustion Fan 11. Negative Pressure Flow Switch 12. Outside Combustion Air 13. Combustion Air Restrictor 14a. Air Wash (Bottom) 14b. Air Wash (Top) 15. Ceramic Door Glass 16. External Heat Exchange Tubes 17. 3 Exhaust 18. Easy to Understand Controls 19. Stainless Steel Firebox Liners 3 (77mm) Dia. Exhaust (centered on appliance) 3 1/2 (89mm) 16 1/2 (420mm) 1 3/4 (45mm) Dia. Air Intake 42 1/4 (1074mm) 25 1/4 (642mm) 33 (839mm) 17 1/2 (445mm) 1 3/4 (77mm) Dia. Air Intake 3 (77mm) 7 1/4 (185mm) 24 1/4 (616mm) 5 3/4 (147mm)

AGP Stove Installation Use these illustrations as a guide only. For complete installation instructions please refer to your Avalon Dealer or go to the AGP Pellet product page at www.avalonfirestyles.com. NOTE: Improper installation of your pellet appliance or failure to operate it in accordance to the guidelines detailed in the Owner s Manual may negate your warranty and endanger your home and family. Minimum Clearances To Combustible Walls Stove clearances measured from top of stove. Connector clearances measured from exhaust vent. Straight Wall Through The Wall Installation Interior Vertical Vent Installation 2 Min. 50.8mm Floor Protection The pellet stove must be installed on a non-combustible surface protector extending the full width and depth of the heater and extending 6 (153mm) in front and 2 (51mm) to each side and under the rear exhaust Tee. Hearth protection must be a minimum.018 thick (26 gauge). Corner Through The Wall Installation 45 Elbow 45 Floor Protection Interior Vertical Vent Installation Tee 2 Min. 50.8mm Alcove Requirements When installed in an alcove with a ceiling height less than 7 ft (2.134 M). Minimum Height is 60 with 6 side and 3 rear clearance to wall Minimum Width is 36-9/16 with min. clearance of 3 for horiz. venting. Maximum Depth is 48 with minimum clearance of 2 from pipe for vertical venting. Child Safety If you have small children or even pets, we highly recommend you consider purchasing a safety screen or guard to prevent the possibility of burns resulting from accidental contact with the hot surfaces of the stove. Ask your Avalon dealer for their recommendations on safety options for your particular installation. Stove and Insert Testing Listed Pelletized Solid Fuel Burning Appliance. Also for use in mobile homes. Certified for the US and Canada. Conforms to ASTM E1509-04, Room Heater Pellet Burning Type (UM) 84 HUD; Certified to ULC S627. Tested and listed for mobile homes in accordance with OAR 814-23-900 through 814-23-909. Tested and Listed by Intertek ASTM E1509-4.

AGP Insert Installation Dimensions and Minimum Fireplace Clearances Use these illustrations as a guide only. For complete installation instructions please refer to your Avalon Dealer or go to the AGP Pellet Insert product page at www.avalonfirestyles.com. NOTE: Improper installation of your pellet appliance or failure to operate it in accordance to the guidelines detailed in the Owner s Manual may negate your warranty and endanger your home and family. 33-1/4-845mm 3 Exhaust 1-3/4 Intake 14-1/4 362mm 8-3/8 213mm 11-1/2-293mm 8-3/8-213mm Min. to Mantle 36-915mm 10 254mm 42-1067mm 24-3/4 629mm Min. Sidewall 9-229mm Min. 21 534mm Min. 21-3/4 553mm 30-1/2 775mm 26 661mm Adjustable Hopper 21 to 24 534mm to 610mm Minimum 16-407mm Minimum 36-3/4-934mm Min. 33-14 845mm Min. 14-1/4 362mm Floor Protection The pellet insert must be installed on a non-combustible surface. A non-combustible hearth must extend 6 to the front and sides of the firebox opening. Hearth protection must be a minimum.018 thick (26 gauge). Pellet Venting Avalon has partnered with Duravent Mfg. to offer two great cost effective venting options specifically designed for the AGP insert. Ask your Avalon Dealer for details. Child Safety If you have small children or even pets, we highly recommend you consider purchasing a safety screen or guard to prevent the possibility of burns resulting from accidental contact with the hot surfaces of the insert. Ask your Avalon dealer for their recommendations on safety options for the AGP insert your particular installation. 3 AGP Pellet Insert Masonry Liner Kit Part # 98900052 4 AGP Pellet Insert Masonry Liner Kit Part # 98900053 See the wide range of Avalon products at: www.avalonfirestyles.com We reserve the right to improve or change our products at any time without prior notification. Please refer to the Owner s Manual for complete installation requirements. Photos and illustrations are for descriptive purposes only. All rights reserve Copyright 2015/11 T. I. #98800719