Wood Burning Safety Guide
|
|
|
- Leo Hines
- 9 years ago
- Views:
Transcription
1 Wood Burning Safety Guide
2 CONTENTS Burning Wood Safely...5 Chimney and Stovepipe Cleaning...8 Chimneys for Wood Stoves...1 Cleaning System...8 Clearances...5 Creosote...8 Disposal of Ashes...8 Draft...2 Factory-Built Chimney Units...4 Fire Extinguishers...8 Floor Protection...7 Flue...2 Masonry Chimneys...3 Multiple Connections...8 Selecting a Stove...1 Smoke Detectors...8 Smoky Fires...4 Stovepipes...7 Page
3 INTRODUCTION Many northern New England households use wood as their primary or supplementary source of heat. Because the area is forested, wood is likely to continue to play an important role in meeting a share of our energy needs. Wood furnaces and stoves have numerous safety concerns not normally associated with gas and oil-fired heat sources. If these special concerns are not accounted for, the risk of fire increases dramatically. This article is a general guide to woodburning. MMG Insurance Company makes no warranties or representations whatsoever, either expressed or implied, as to its accuracy or completeness, nor do we assume or accept any liability for the use of, or damages resulting from the use of, any information contained in this guide. While installation specifications in this guide have been taken from national sources, safety codes and standards are being revised. In your area, a building permit may be required to install woodburning stoves. We urge you to check with local governmental bodies for specific installation and inspection requirements. i
4 This article is designed to help make our policyholder a better woodburner. It explains: what to look for in a stove and chimney, the ins and outs of the fuel that goes into the woodstove and what is required to install, operate and maintain a woodstove safely and efficiently. No matter how you look at wood heat, the one thing that everyone can agree upon is that heating with wood is NOT automatic! The efficiency, safety, cleanliness and level of pollution associated with wood heat depends heavily on the person who burns the wood. SELECTING A STOVE Be sure your solid fuel burning appliance is made of sturdy, suitable material, such as cast iron or steel. Look for stoves listed by Underwriters Laboratories (UL) or other recognized laboratories. Before deciding which appliance is best for you, you must determine what size appliance will work best in your home. When it comes to woodburning, bigger is definitely not better. Here s why: For wood heat to work properly, the appliance should work at or near its maximum efficiency. That means the appliance must contain a good, hot fire. If the appliance is too large for the space it must heat, it will have to be damped down. That means the fire will smolder rather than burn and that will increase creosote and smoky fires. (For additional information on sizing your woodstove, contact your dealer or equipment manufacturer.) If you purchase a used solid fuel burning appliance, check it carefully for cracks or other defects. The legs, hinges, gates and draft louvers also should be checked carefully. If you live in a Mobile Home be sure your woodstove is a (UL) approved stove specifically designed for use in such a dwelling. CHIMNEYS FOR WOOD STOVES All woodburning appliances need a tight, well designed and constructed chimney to maximize efficiency and to minimize the danger of unwanted fire. Most homeowners who add a woodburning appliance will also have to add a chimney. This guide explains some basic chimney requirements and provides basic information on the construction of the two general types, masonry and factorybuilt. The chimney serves two major functions for the operation of a solid fuel burning appliance. It provides a draft (a vacuum which draws oxygen needed for combustion into the stove.) It also discharges the products of combustion outside the living area. Some of the heat from the appliance 1
5 and occasional sparks are also discharged through the chimney. For this reason, chimneys must be carefully constructed and well maintained. Draft is caused primarily by the natural rising of warm air - smoke - up the chimney. In general, the taller the chimney, the greater the draft. A warm chimney will provide greater draft than a cool chimney because a warm chimney does not cool the rising smoke. This is why stoves generally perform better after they have been in use long enough to warm the chimney. For the same reason, chimneys which are located within the house generally produce better draft than those located outside the house. Outside air currents can affect draft if they swirl around obstructions and blow down the chimney rather than across the outlet. Eddy currents of air that affect draft are most often caused by wind blowing across nearby parts of the building roof or trees. For this reason, certain clearances have been established to lessen the problem. A chimney must extend at least three feet above a roof and at least two feet above a roof ridge or any raised part of a roof within 10 feet. Any chimney more than 10 feet from the roof ridge must be 2 feet above the distance 10 feet from the roof line. See Figure 3 for an illustration of these clearances. Sometimes getting enough vertical clearance to prevent eddy currents from affecting chimney draft is impossible. This may be because of unusual heights of nearby trees. A hood or chimney cap can sometimes be used to prevent eddies from interfering with draft. Caps and hoods also minimize rain as well as birds or other animals entry into the chimney during periods of non-use. FLUE The opening in the chimney through which smoke passes is called the flue. Smoke moves up the flue in a swirling pattern. Round flues are more efficient than square or rectangular ones because they offer little obstruction to the natural flow of smoke. For best performance, the inner surface of flues should be as smooth as possible. 2
6 One frequently asked question about chimneys for wood stoves is, Can a solid fuel burning appliance be connected to an existing flue that serves another appliance? National Fire Protection Association (NFPA) recommended standards prohibit connecting a solid fuel burning appliance to a chimney flue serving another appliance burning dissimilar fuels unless listed for such connection. This requirement has been incorporated into most building codes and insurance regulations. NFPA recommends that each appliance be connected to a separate flue. This reduces interference between units and increases the efficiency of each appliance. MASONRY CHIMNEYS Many chimneys in new and existing homes are constructed of non-combustible masonry material. This may be brick, chimney block or stone. Masonry chimneys must be constructed on a concrete footing to support the chimney without settling. Chimney footings must extend below normal frost depth and rest on undisturbed or well compacted soil. Masonry chimneys should be lined with vitrified fire clay tile (flue tile) or other listed lining material (see NFPA 211). This tile is designed to withstand rapid fluctuations in temperature without cracking and has a smooth surface that is easily cleaned. Flue tiles are cemented together with refractory mortar, which is struck smooth on the inside. There should be a minimum of 1/2-inch and maximum 4-inch space between the outside of the flue tile and the surrounding masonry to reduce heat loss through the chimney and allow for thermal expansion. Relining of masonry chimneys is acceptable as long as listed products are installed according to their listing. Brick walls for chimneys must be at least four inches thick. Chimney block may also be used. The block must be 4-inch solid masonry or 6-inch hollow masonry with the cells fully filled with mortar. In both cases, the block must be waterproofed. Masonry units should be laid with cement mortar. A chimney may contain more than one flue, however, they should be separated by nominal 4- inch thick solid masonry. Interior masonry chimneys must be separated from combustible material by at least two inches on all sides. This means that framing and other combustible material in walls, floors, ceilings, and roofs must stop at least two inches from the chimney. Connection of the smoke pipe to a masonry chimney is made through the use of 5/8" thick, round fire clay or 24-gauge galvanized steel units called thimbles. These are installed horizontally into the chimney wall. Thimbles must not extend into the chimney beyond the inner surface of the flue liner (see figure 4.) Soot and creosote will accumulate on the inner surface of flues. A tight-fitting cleanout door must be installed at the base of the chimney to assist in cleaning. 3
7 Chimney Installation Guidelines 1. Support the chimney on a properly designed foundation. 2. Do not change the size or shape of the chimney within six inches above or below the roof joists or rafters, where the chimney passes through the roof or any other combustible construction. 3. Install ferrous metal frames and doors in cleanout openings. Doors should be able to be shut tightly when not in use. 4. Make sure a two-inch space exists between the chimney and surrounding combustible building materials. Firestops of 24-gauge sheet metal spanning this space must be installed at each ceiling and floor. 5. Line the chimney with fire clay, or with an equivalent flue lining. 6. To ensure a proper draft, make sure the chimney rises at least three feet above the highest point where it passes through the roof, and at least two feet higher than any portion of the building within 10 feet of the chimney. 7. Smoke-test the chimney to discover any leaks. 8. If your home has a fireplace, make sure the hearth extension is made of non-combustible material beneath the hearth. Make sure there is no combustible material within six inches of the sides or fireplace opening. FACTORY-BUILT CHIMNEY UNITS Factory-built chimneys used for wood stoves must bear the Underwriters Laboratories (UL) listed label, (Note: Underwriters Laboratories of Canada listings may apply) and be designed as all fuel chimney units. UL listed vents commonly used for oil or gas-fired heaters are not suitable for use with wood stoves. There are two UL listings which must be noted. UL 103 and UL 103 HT. The 103 HT chimney is required with stoves that operate with the loading door closed. Freestanding fireplaces and heaters that operate with the door open can be connected to chimneys with the UL 103 listing. Open door heaters burn cleaner, create little creosote and, therefore, less potential of a chimney fire. Airtight wood stoves with closed doors produce a smoldering fire, and create heavy creosote with much higher potential of chimney fire, thereby requiring the UL 103 HT (high temperature) factory-built chimney. Factory-built chimneys are available in several sizes, and a variety of accessories are available to accommodate different types of installation. There generally is a required 2-inch clearance between these units and combustible material. Manufacturers installation requirements must be adhered to. SMOKY FIRES Sometimes even properly constructed and operated stove-chimney combinations result in smoky fires. Bird nests, fallen bricks and a variety of other objects have all been found in chimneys. Any object which restricts the smooth flow of exhaust gases can cause smoky fires. Occasionally, smoking can be caused by: a. Unusual wind direction resulting in abnormal eddy currents. If this is a persistent problem, extending the chimney height or adding a cap may help. 4
8 b. Burning green or wet wood or tool cool a fire can prevent the chimney from warming up and developing a full draft. BURNING WOOD SAFELY According to the Consumer Product Safety Commission, wood stoves and other types of fixed heaters cause more than 30,000 residential fires in the United States every year. The wood stove user must pay close attention to SAFETY -- SAFETY at the time of installation, SAFETY when it comes to operating the woodstove, SAFETY in disposing of the ashes and SAFETY in maintaining the appliance, the stove pipe and the chimney. Any solid-fuel appliance that is professionally installed, and all appliances installed in public buildings, must meet strict standards established by each state. These standards should be followed by homeowners who install their own appliances, whether they burn wood, wood pellets or coal. (Refer to NFPA 211 and NFPA 90B Warm Air Heating Systems.) To order, call NFPA at CLEARANCES Take particular care to provide enough clearance for your woodburning device. The amount of clearance needed will depend to some degree on the type of device you are installing -- whether it is a radiant device or a circulating device. These clearances may vary and therefore Maine Mutual Fire Insurance Company requires the completion of our Supplemental Heating Questionnaire MMG-77 (12-95). Radiant heaters have no air space -- the single wall encloses the firebox. Heat radiates into the room via infrared waves directly from the walls of the device. The infrared waves carry heat directly into nearby combustible materials, changing their composition and lowering the temperature at which they can spontaneously combust. Because of these factors, more clearance is needed. Extreme care needs to be taken to keep radiant appliances from combustible materials -- materials such as magazine racks, furniture, drapes, paneling and even the wood box. Plaster and sheet rock walls are considered combustible because of the wooden studs behind the walls. Heating surfaces of radiant stoves should be at least 36 inches from any combustible material. The MINIMUM clearance should be observed no matter what the stove s exterior material -- when considering clearances, there is virtually no difference between cast iron or heavy steel. There is a way to move your woodburning appliance or stovepipe closer to a combustible surface: You may use wall or ceiling protectors. These protectors mount on the wall or ceiling and reflect heat away from combustibles. The protectors have mounts or spacers, that hold them one 5
9 inch away from the wall or ceiling and allow air to pass between the wall or ceiling surface and the surface of the protectors. Besides the spacers that can be purchased, metal washers, thin tubing, electrical insulators and masonry wall ties may be used. Protectors should be mounted so as to leave a one-inch space between the bottom of the protector and the floor. Wall protectors are made of a variety of materials, 24-gauge or thicker sheet metal or 3 1/2- inch masonry wall can be used. See Table 1. Table 1 Minimum clearance allowed when installing protectors between woodstoves or stovepipes and combustible ceilings or walls. Type of protection distance allowed Stovepipe from from protected ceiling from protected wall Connectors 1) 3 1 2" masonry wall - no ventilation NA 24" 12" 2) 1 2" non-combustible insulation board over 1" glass fiber or mineral wool batts - no ventilation 24" 18" 12" 3) Minimum 24-gauge metal, 1" ventilated space 18" 12" 9" 4) 3 1 2" masonry wall, 1" ventilated space NA 12" 6" 5) Listed prefabricated systems Per manufacturer s specs Note: When using wall clearance reduction systems, no clearance is to be less than 12 inches. This applies to listed and unlisted appliances, unless stated by the manufacturer. 6
10 FLOOR PROTECTION All combustible floors must be protected. The amount of protection depends upon the length of the appliance s legs. The floor protection should extend at least 18 inches in all directions from the stove (see Table 2). Table 2 Floor clearances (For listed and unlisted appliances) Length of stove leg Less than 2 inches Floor clearance and protection Fire resistant floor (non-combustible) 2-6 inches Combustible floor protected by 4" of hollow masonry, laid to provide circulation through the masonry layer, covered by 24-gauge sheet metal. Over 6 inches Combustible floor protected by 2" thick masonry, placed over a sheet of 24-gauge sheet metal. STOVEPIPES Of the 30,000 residential wood appliance fires, about 10 percent start in the vicinity of the stovepipe -- the part that connects the appliance with the chimney. Stovepipes should be made of steel no thinner than 24-gauge. No part of the stovepipe should be closer than 18 inches to any combustible material. The ceiling should be considered combustible material. The distance may be reduced as outlined in Table 1. In new construction, each combustion appliance must have its own flue. A stovepipe should not be connected to a flue serving a fireplace or oil furnace -- each should have its own flue. 1. Use a UL approved metal or fireclay thimble to pass a stovepipe through a non-combustible wall and into the chimney. Attach the thimble to the masonry with refractory cement. The thimble should extend to the inner surface of the chimney liner, but not beyond. The stovepipe should end flush with the inner end of the thimble. 2. Use stovepipe that has a diameter as large as the flue collar where the pipe joins the stove. Stovepipe Installation Guidelines at the thimble or point of entry to the chimney. 5. Horizontal runs should be no longer than 75 percent of the vertical chimney height above the thimble where the connector pipe enters the chimney. 6. Overlap at least 2 inches of stovepipe at the joints with the crimped end pointed down to prevent creosote leaks. Secure the joint with three sheet metal screws. 3. Stovepipe should be as straight as possible. No more than two bends should be used. Additional bends may cause creosote to collect in the stovepipe or chimney,and that may block the flow of flue gas, thereby increasing the risk of fire. 4. Install the stovepipe with a rise of a quarter-inch for each foot of pipe in a horizontal run. The highest point should be 7. Be sure the stovepipe fits snugly, including connections with the stove and thimble. The pipe must not stick into the chimney flue itself because this would hamper the draft. 8. Never pass a stovepipe through a roof, ceiling, closet or concealed area. 7
11 MULTIPLE CONNECTIONS If a woodburning appliance is attached to a flue already serving a fireplace, sparks may enter the house through the fireplace opening. In the event of a chimney fire, the fireplace opening may deliver large amounts of air to the fire and obstruct attempts to extinguish it. A similar problem may be encountered if the flue services an oil furnace, since air may enter the chimney through the furnace s barometric damper. A woodburning appliance may also lessen the efficiency of an oil furnace on the same flue because of changes in the flue s draft characteristics. NFPA recommends that each appliance be connected to a separate flue. FIRE EXTINGUISHERS AND SMOKE DETECTORS A multi-purpose ABC dry chemical fire extinguisher should be installed for each woodstove. The extinguisher should be located near the stove and be easy to reach. All homes should have at least one smoke detector on each living space level, whether the home is heated with wood or not. The detectors should be mounted on the ceiling or on the wall within 12 inches of the ceiling. In homes equipped with woodburning appliances, the detectors should be mounted between the woodburning device and the home s bedrooms. Don t forget to test the smoke detectors regularly. DISPOSAL OF ASHES Store ashes in a non-combustible metal container with a tight-fitting lid. The closed container should be placed on a non-combustible floor or on the ground, well away from all combustible materials, awaiting final disposal. CHIMNEY AND STOVEPIPE CLEANING If every woodstove worked perfectly, if every stick of firewood was completely seasoned, and if every woodstove owner knew everything there was to know about efficient woodstove operation, we wouldn t hear very much about creosote. Of course, that isn t the case. Creosote is a fact of life for the wood burner, and knowing how to deal with it is an essential part of the wood burning process. What is creosote? It is a dark brown or black substance that is formed by the incomplete combustion of wood. It is most likely to form when dense smoke makes contact with a cool chimney surface. It may be a tar-like substance, although at times, it is more watery. It can collect in most any part of your woodburning system. People used to think creosote was more apt to form as a result of using green firewood or by burning softwoods rather than hardwoods. But research has shown us that creosote is more a result of HOW you burn, rather than WHAT you burn. Good seasoned hardwood will still form large 8
12 amounts of creosote if it is burned in a damped-down stove. Unseasoned, green firewood will produce large amounts of creosote, but that seems to be more a function of the water that must be driven out of the wood before it can burn at a high enough temperature to prevent creosote production. The temperature of the chimney also plays an important part in creosote production. That s why outside chimneys and long runs of stovepipe are more apt to host creosote formation -- they tend to be colder than inside chimneys or short runs of stovepipe. All woodburning systems require some form of regular cleaning. Creosote should be removed when it reaches a thickness of quarter-inch or more. At the very least, chimneys and stovepipes should be cleaned once a year. Many people do this annual job in the spring, before there is too much rain and snow. Rain and snow can mix with the creosote, forming caustic substances. It can also smooth out the creosote, making it much harder to remove. Here are some of the things you will need to do: You can clean your chimney from inside the house if your chimney has a cleanout door or if the chimney is connected to a fireplace. Otherwise, you will have to clean it from outside the house. If you clean the chimney from inside the house, close off the bottom of the chimney or the fireplace, and make sure to cover the surrounding area with dust covers -- it can be a very messy job! If you are working on a chimney that is attached to a fireplace, don t forget to clean the shelf above the damper. This is a very likely spot for the accumulation of creosote. There are a number of brushes and other cleaning devices available for chimney cleaning. Buy brushes that fit the shape of your chimney. If you have a masonry chimney, use a steel brush. Flat wire bristles are better at removing hard creosote than round bristles. If you have a stainless steel or factory-built chimney, use a plastic brush -- metal brushes can scour the metal of the chimney, causing more rapid deterioration of the chimney by the caustic elements in the wood smoke. 9
13 Besides brushes, various types of metal and plastic scrapers are also available for removing stubborn creosote. All of these implements are available at hardware stores or stove shops. Experiment to find the type that works best for you. Some brushes are equipped with loops at both ends so ropes can be attached. With this implement, one person on the roof can pull the brush up while another person in the house can pull the brush down. Others have a loop for the attachment of a weight that will pull the brush down the chimney. Still others have connectors for the attachment of extension rods. If the creosote buildup is minimal, one pass through the chimney may be enough. If the creosote is heavier or harder, you may have to scrub one area until it is clean before moving on to another section. Some components of creosote are carcinogenic, so always wear protective clothing and a dust mask. Disassemble the stovepipe and take it outside to clean. You may have to purchase brushes and other implements that are shaped differently from the ones you purchased for the stove. Scrape and scrub the inside of the stovepipe in the same manner you used on the chimney. Don t forget to clean the inside of the stove, too! Creosote can collect in areas of the stove just as it collects in the stovepipe and chimney. Because of the inherent risks in solid fuel burning appliances, it is important to take the precautions of continuous maintenance and use the appliance in strict accordance with manufacturer s guidelines. References: National Fire Protection Association Department of Economic and Community Development (Maine) National Association of Mutual Insurance Companies Insurance Information Institute 10
woodburning stoves installation and procedures
woodburning stoves installation and procedures REVISED AUGUST, 2006 CONFORMS TO NFPA 211-2006 Legal Disclaimer The information contained herein is not intended to be used as a guide for installation or
Wood Heat The Safe Way
Wood Heat The Safe Way A general guide to the safe and efficient installation and operation of wood heating appliances. Prepared by Farm Bureau Insurance in collaboration with Lansing Community College
Table of Contents Interior Exterior
Legal Disclaimer The information contained herein is not intended to be used as a guide for installation or operation of any solid or liquid fuel heating device. Use of this information is at your own
CHIMNEYS AND FIREPLACES
CHAPTER 10 CHIMNEYS AND FIREPLACES > > Pursuant to ORS 215.730, if a single-family dwelling located on forest-zoned lands has a chimney or chimneys, each chimney shall have a spark arrester. SECTION R1001
WOOD HEAT TECHNIQUES TACTICS & TIPS
HOME ENERGY GUIDE WOOD HEAT TECHNIQUES TACTICS & TIPS Minnesota Department of Commerce Energy Information Center Wood is a widely used heating fuel: approximately a third of all Minnesota homes use wood
Fire Damage. To Help Prevent. a Guide
a Guide To Help Prevent Fire Damage Fire damage in your home can be costly and emotionally devastating. The damage caused by the flames and smoke can destroy a lifetime of memories in a matter of minutes.
780 CMR 60.00 CHIMNEYS, FIREPLACES AND SOLID FUEL-BURNING APPLIANCES
780 CMR 60.00 CHIMNEYS, FIREPLACES AND SOLID FUEL-BURNING APPLIANCES 780 CMR 6001 MASONRY CHIMNEYS 6001.1 General. Masonry chimneys shall be constructed, anchored, supported and reinforced as required
Troubleshooting Draft Problems in Chimneys
Troubleshooting Draft s in Chimneys Draft is the difference in pressure between the inside of the chimney and inside of the house. This is affected mostly (though not completely; see info on fans for example)
COMMERCIAL COOKING HOODS, VENTILATION & FIRE SUPPRESSION SYSTEM GUIDELINES AND PROCEDURES
COMMERCIAL COOKING HOODS, VENTILATION & FIRE SUPPRESSION SYSTEM GUIDELINES AND PROCEDURES These guidelines are to be used for ALL commercial cooking hoods, ventilation systems and related fire suppression
Installation Instructions
Installation Instructions Pedestal Models FS 500 LE FS 800 LE Insert Models IS 500 LE IS 800 LE Pecan Engineering Pty Ltd 13 Acorn Road Dry Creek South Australia 5094 Email [email protected] Phone:
CHAPTER 14 BUILDING CODE
CHAPTER 14 BUILDING CODE 14.01 ADOPTED STANDARDS 14.02 BUILDING INSPECTOR 14.03 BUILDING PERMIT REQUIRED 14.04 BUILDING INSPECTIONS 14.05 NEW METHODS AND MATERIALS 14.06 CITY NOT LIABLE 14.07 ROOM HEATERS,
RESIDENTIAL ROOFING & RE-ROOFING, ROOF VENTILATION AND ROOF SHEATHING REQUIREMENTS MICHIGAN RESIDENTIAL CODE 2000
RESIDENTIAL ROOFING & RE-ROOFING, ROOF VENTILATION AND ROOF SHEATHING REQUIREMENTS MICHIGAN RESIDENTIAL CODE 2000 SECTION R905 REQUIREMENTS FOR ROOF COVERINGS R905.1 Roof covering application. Roof coverings
RESIDENTIAL PLUMBING ALTERATIONS PERMIT REQUIREMENTS
RESIDENTIAL PLUMBING ALTERATIONS PERMIT REQUIREMENTS The following guidelines are intended to assist with the permit acquisition process with regard to Plumbing Alterations. Not all information, or additional
CHAPTER 5 WATER HEATERS
PlumbingCode06_ch05 5/29/06 8:12 AM Page 1 CHAPTER 5 WATER HEATERS Water heaters are only a small portion of a plumbing system, but they are important, and they can be dangerous. Many plumbers take water
THREE. Heating and Cooling
THREE Heating and Cooling 17 Condensation Drain Line The line that drains condensed moisture away from your heating and/or cooling unit needs periodic maintenance. If your unit is located in the attic,
Chimneys in Thatched Properties
Chimneys in Thatched Properties Compliance with Building Regulations when installing or repairing a chimney or re-thatching a roof that abuts a chimney The increasing problem of thatch fires Over the last
INSTALLATION AND OPERATIONS GUIDE FOR GRAND CANYON GAS LOG SYSTEMS
INSTALLATION AND OPERATIONS GUIDE FOR GRAND CANYON GAS LOG SYSTEMS Installation and service must be provided by a qualified installer, service agency or gas supplier Grand Canyon Gas Logs, logs are made
heating 3 & cooling heating and cooling 2010 PulteGroup, Inc. All Rights Reserved.
3 & cooling 17 heating 2010 PulteGroup, Inc. All Rights Reserved. condensation The line that drains condensed moisture away from your heating and/or cooling unit needs periodic maintenance. Air conditioning
FARMERS MUTUAL INSURANCE COMPANY UNDERWRITING GUIDELINES HOMEOWNER PROGRAM
UNDERWRITING GUIDELINES HOMEOWNER PROGRAM The following guidelines should be considered when offering insurance for certain types of risks. When evaluating the acceptability of a risk, the company underwriter
CROWN BOILER COMPANY BWF SERIES BOILER CATEGORY I VENT KIT INSTALLATION AND OPERATING INSTRUCTIONS
CROWN BOILER COMPANY BWF SERIES BOILER CATEGORY I VENT KIT INSTALLATION AND OPERATING INSTRUCTIONS WARNING Improper installation, adjustment, alteration, service, or maintenance of this product can cause
CARE DURING CONSTRUCTION OF HOUSE:
In addition, your heater is equipped with a sliding shut off damper with a wooden handle, as well as a by-pass channel with a pivoting weighted handle. OWNER MANUAL ALBIECORE HEATER OPERATING AND MAINTENANCE
GROWTH MANAGEMENT DEPARTMENT 201 SE 3 rd ST, (Second Floor), Ocala, FL 34471 (352) 629-8421; FAX: (352) 629-8264
BUILDING CODE GUIDELINE FOR MECHANICAL INSPECTIONS Building Code compliance is the obligation of design professionals and/or contractors. Plan Review and Inspection Guidelines are intended to be used by
Installation Instructions. Connector between an appliance to the Type B-Vent system. Single- and Double-Wall. DuraConnect
Installation Instructions Connector between an appliance to the Type B-Vent system. Single- and Double-Wall. DuraConnect A MAJOR CAUSE OF VENT RELATED FIRES IS FAILURE TO MAINTAIN REQUIRED CLEARANCES (AIR
Chapter 3 Pre-Installation, Foundations and Piers
Chapter 3 Pre-Installation, Foundations and Piers 3-1 Pre-Installation Establishes the minimum requirements for the siting, design, materials, access, and installation of manufactured dwellings, accessory
The Homeowner s Guide To CHIMNEYS, FIREPLACES AND WOODSTOVES
1 The Homeowner s Guide To CHIMNEYS, FIREPLACES AND WOODSTOVES Written By: JIM BREWER & ASHLEY ELDRIDGE 2 COPYRIGHT 1990 2003 By: James P. Brewer and Ashley H. Eldridge United States Copyright Office Registration
PRE-ASSEMBLED INSTALLATION INSTRUCTIONS FOR PACB SERIES COAL FIRED OVENS
PRE-ASSEMBLED INSTALLATION INSTRUCTIONS FOR PACB SERIES COAL FIRED OVENS OVENS MANUFACTURED BY: EARTHSTONE OVENS-6717 SAN FERNANDO RD GLENDALE CA 91201 TELEPHONE: 800-840-4915 818-553-1134 FAX: 818-553-1133
Boston, Venice, Kodiak. Enviro Wood Fireplace Inserts
Boston, Venice, Kodiak Enviro Wood Fireplace Inserts Why buy an Enviro Wood Insert? Up to 84.7% Efficiency - EPA approved and up to 84.7% efficiency - Enviro makes highly efficient wood inserts to help
(This report is endorsed) Industrivej 20, 9900 Frederikshavn, Danmark
Spectrum Laboratories Ltd is accredited by International Accreditation New Zealand (formerly Telarc). The tests reported herein have been performed in accordance with the terms of our accreditation. This
2010 Residential Water Heater Replacement Check List
2010 Residential Water Heater Replacement Check List The intent of this check list is to provide installers a general reference for the enforcement of code requirements in the Greater San Diego Area. This
BATHROOM HEATER. User's Manual. Page 2...A515 Page 9...A716
BATHROOM HEATER User's Manual Page 2...A515 Page 9...A716 BATHROOM HEATER User's Manual A515 SAVE THESE INSTRUCTIONS AND READ ALL INSTRUCTIONS BEFORE USING THE HEATER. Dear customers, Thank you for selecting
FREESTANDING CLEAN AIR WOODBURNER
Please read this booklet and keep for future reference for the safe installation of your: FREESTANDING CLEAN AIR WOODBURNER This fire conforms with Ecan Requirements All installations must be in accordance
HOW MUCH FUEL DOES A GAS STOVE CONSUME AND HOW MUCH DOES IT COST TO OPERATE?
WHAT IS A BTU? The standard energy measurement is the BTU (British Thermal Unit). Each BTU unit is determined by the amount of thermal energy required to raise the temperature of one pound of water by
Home Inspection Report
4949 Brownsboro Rd Suite 293 Louisville, KY 40223 (502) 414-1440 [email protected] Inspected By: William Carter, HI-1956 Home Inspection Report Prepared For: Edward Cullen Property Address:
Best Basement Water Management Practices
Best Basement Water Management Practices Guide written by Patrick Sluss Sluss Construction (330) 224 5394 When a home owner is faced with a leaking basement there is a way to correct the problem and a
Boiler Plan II Table of Contents
Cover Page Table Of Contents Introduction Parts List Additional Materials Assembly instructions Drawings 1-15 Boiler Plan II Table of Contents Introduction This will be a very rewarding project, if you
This handout is a guide only and does not contain all of the requirements of the Minnesota State Building Code or city ordinances.
Basement Finishing Guide Community Development Department Building Inspections Division 5200 85 th Avenue North / Brooklyn Park, MN 55443 Phone: (763) 488-6379 / Fax: (763) 493-8171 6/15 www.brooklynpark.org
2. What building projects are exempted? (permit not required)
BUILDING AND SAFETY DEPARTMENT 1. What building projects require a permit? Following is a list of projects that require building permits based on Appendix chapter 1 of the California Building Code and
Across America. Wood & Coal Brochure
Across America Wood & Coal Brochure Rev. Sep. 2011 Bay Series... A series of well built high heat performers featuring decorative side windows and full view glass door with airwash system to help keep
Building Condition Assessment Report
Building Condition Assessment Report Asset C3c - Oak Terrace Cottage 121 Address Riverview Lands, 2601 Lougheed Highway, Coquitlam, BC. V5C 4J2 Construction Year Size (Gross Floor Area) 1920. 2,553 Sq.Ft.
19 Ellis Park Road, Toronto
19 Ellis Park Road, Toronto Inspection Report September 9, 2015 19 Ellis Park Road, Toronto Inspection Report Overall Condition: This is a solidly built older double-brick home that is in fairly original
B. DEFINITIONS LINING OLD CHIMNEYS A. INTRODUCTION C. REASONS FOR LINING
LINING OLD CHIMNEYS A. INTRODUCTION The most appealing focal point in any room must be the fireplace. Be it an open fire, closed stove or roomheater, the leaping flames and glowing coals are the real heart
Spray Booth Guideline
Department of Development Service 135 North D Street, Perris CA. 92570 Phone: (951) 443-1029 Fax: (951) 943-3293 PURPOSE The intent of this guideline is to provide the information necessary to ensure that
The growing popularity of Gas Fireplaces has created a demand for an ever increasing array of styles and sizes to fit every decor and budget.
Consumer Information Guide to Gas Fireplaces A Gas Fireplace gives you all the ambiance, warmth and comfort of a traditional wood-burning fireplace. They are convenient, easy to use and cost effective.
Decree of the Ministry of the Environment on fire safety of ventilation systems
THE NATIONAL BUILDING CODE OF FINLAND MINISTRY OF THE ENVIRONMENT Housing and Building Department Decree of the Ministry of the Environment on fire safety of ventilation systems Adopted in Helsinki, 18
Crawford Inspection Services C.C.B. # 76914 www.crawfordinspections.com
Crawford Inspection Services C.C.B. # 76914 www.crawfordinspections.com Portland Area PO Box 665 West Linn, OR 97068 Ph: (503) 650-6957 Salem Area 5434 River Rd. N; #192 Keizer, OR 97303 Ph: (503) 362-5809
Subpart 1. Installation. All plumbing systems must be. installed and tested according to this chapter and chapter 4715,
4658.4500 PLUMBING SYSTEMS; NEW CONSTRUCTION. Subpart 1. Installation. All plumbing systems must be installed and tested according to this chapter and chapter 4715, the Minnesota Plumbing Code. Subp. 2.
Contents. Who is Premier Guarantee? Your Structural Warranty. What to look out for in your New Home. Running in your New Home. DIY and Maintenance
Homeowners Handbook Contents Who is Premier Guarantee? Your Structural Warranty What to look out for in your New Home Running in your New Home DIY and Maintenance Structural Warranty Cover This booklet
If you are a web registered user of ArlingontPermits.com you may also request an inspection at:
TECHNICAL BULLETIN Community Development & Planning, Building Inspections TOPIC: Permits & Inspections for Roofing Replacement Effective November 1, 2011 Revised This Technical Bulletin will provide contractors
Figure 22: Typical Individual Venting. Figure 21: Single Water Heater Venting
ING THE WATER HEATER The purpose of venting a gas or oil-fired water heater is to completely remove all products of combustion and to vent gasses to the outside air without condensation in the vent or
Ravelli Camino Insert Wood Pellet Burning Heater. Wood Pellet Fire Installation Specifications. Safety testing of the
Ravelli Camino Insert Wood Pellet Burning Heater Fire shown installed with a non-combustible floor - no hearth required Ravelli Camino Insert Wood Pellet Fire Installation Specifications Safety testing
SPECIFICATION & INSTALLATION GUIDE FOR MASPORT LE4000 PROVINCIAL INSERT FIRE, NEW ZEALAND MODEL
SPECIFICATION & INSTALLATION GUIDE FOR MASPORT LE4000 PROVINCIAL INSERT FIRE, NEW ZEALAND MODEL Manufactured in New Zealand by: GLEN DIMPLEX AUSTRALASIA LIMITED PO Box 58-473 Botany Auckland 2163 Ph: 0800
HVAC Code Requirements
one and two family dwellings? Answer: SECTION 2001: GENERAL 2001.1 Air supply. Fuel-burning equipment shall be provided with a supply of air for fuel combustion, draft hood dilution and ventilation of
The Savannah Steel Series Wood Burning Stoves and Inserts
The Savannah Steel Series Wood Burning Stoves and Inserts The Savannah Steel Series Wood Burning Stoves The wood burning steel stove adds warmth and elegance to any décor. Designed with the latest wood
Masonry Heaters: Planning Guide for Architects, Home Designers and Builders. By Alex Chernov, a Certified Heater Builder. www.stovemaster.
Masonry Heaters: Planning Guide for Architects, Home Designers and Builders. By Alex Chernov, a Certified Heater Builder. www.stovemaster.com 2008 Legal notice: This Planning Guide serves informational
DRYER VENTING SPECIFICATIONS DRYER SAFETY
DRYER VENTING SPECIFICATIONS Table of Contents DRYER SAFETY...1 INSTALLATION REQUIREMENTS...4 Venting Requirements...5 DRYER INSPECTION AND CLEANING...7 Frequency of Exhaust System Cleaning...7 Inspecting
Basement Moisture Problems
Foundations Foundation Purpose The purpose of a foundation is to distribute the weight of a structure securely into the ground. Engineering data regarding soil, rock and water conditions are used to design
Static Electricity. A Health and Safety Guideline for Your Workplace. What Are Some Sources of Static Electricity? What is Static Electricity?
A Health and Safety Guideline for Your Workplace What is static electricity? What causes it? How is it hazardous? And, most importantly, how can it be controlled? All of these questions will be answered
Foundation Experts, LLC Specializes in Foundation Repair and Waterproofing
1 Most basements show some signs of leaking and cracking. Through the years, problems with water, poor soils, grading, drainage and possible settling affect the integrity of a basement. Being able to recognize
TFL CUSTOM FIREPLACES WITH MASONRY BRICK LININGS. standard INSTALLATION SPECIFICATION INTO TIMBER FRAMING
6.CW.1A TFL CUSTOM FIREPLACES WITH MASONRY BRICK LININGS wood or gas standard INSTALLATION SPECIFICATION INTO TIMBER FRAMING The Fireplace Ltd is able to design and fabricate custom brick open masonry
LAYING BLOCK AND BRICK
LAYING BLOCK AND BRICK Products highlighted in this section: SAKRETE Type N Mortar Mix SAKRETE Type S Mortar Mix Brick And Block Laying Basics The first step in building a brick or block wall is to construct
Boiler and Burner Cleaning and Servicing Specifications
Boiler and Burner Cleaning and Servicing Specifications The Town of Groton of Public Works Department is requesting bids to provide manufacturers recommended maintenance, repairs and emergency service
37101 Newark Boulevard, Newark, CA 94560-3796 510-578-4261 Fax 510-578-4307 e-mail: [email protected]
Reroofing Projects CITY OF NEWARK, CALIFORNIA BUILDING INPECTION DIVIION 37101 Newark Boulevard, Newark, CA 94560-3796 510-578-4261 Fax 510-578-4307 e-mail: [email protected] Revised July
Final inspections are completed by site visit only. Access to fenced yards shall be planned.
ROOFING RESIDENTIAL BUILDING INSPECTIONS DEPARTMENT www.ci.blaine.mn.us This handout is intended only as a guide and is based in part on the 2015 Minnesota State Building Code, Blaine City ordinances,
BOROUGH OF NATIONAL PARK APPLICATION FOR A CERTIFICATE OF OCCUPANCY FOR CHANGE OF OCCUPANCY ADDRESS OF PROPERTY FOR INSPECTION CURRENT OWNER
BOROUGH OF NATIONAL PARK APPLICATION FOR A CERTIFICATE OF OCCUPANCY FOR CHANGE OF OCCUPANCY ADDRESS OF PROPERTY FOR INSPECTION # BLOCK LOT VACANT YES NO CURRENT OWNER NAME ADDRESS TELEPHONE # PROSPECTIVE
How to Reduce Your Exposure to Chemicals at Home, Work, and Play
How to Reduce Your Exposure to Chemicals at Home, Work, and Play You come into contact with chemicals every day. This is called chemical exposure. Although some chemical exposures are safe, others are
KITCHEN AND BATH REMODELING BUILDING PERMIT REQUIREMENTS
St. Louis County Department of Public Works Division of Code Enforcement KITCHEN AND BATH REMODELING BUILDING PERMIT REQUIREMENTS This guideline is intended to provide the homeowner/contractor with the
Report for. Dick and Jane Homeowner. 1234 Lovers Lane, Houston, Texas 77000
Report for Dick and Jane Homeowner 1234 Lovers Lane, Houston, Texas 77000 March 17, 2004 I NI NP R Inspection Item I. STRUCTURAL SYSTEMS o o o A. Foundations (If all crawl space areas are not inspected,
Gas Stoves. H15-10 Direct Vent Gas Stove. Model H15-NG10 H15-LP10. Approved Venting Systems
H15-10 Direct Vent Gas Stove Model H15-NG10 H15-LP10 Fuel Type Natural Gas Propane Minimum Supply Pressure 5.0 W.C. (1.25 kpa) 12.0 W.C. (3.00 kpa) Manifold Pressure - High 3.8 W.C. (0.95 kpa) 11 W.C.
This brochure is a guide on how to use your wood heater to maximise the heat obtained from your wood and reduce woodsmoke pollution.
This brochure is a guide on how to use your wood heater to maximise the heat obtained from your wood and reduce woodsmoke pollution. The facts are clear Many Australian households use woodheaters and open
ECHO System for Basements
ECHO System for Basements Homeowners looking for more space are all too familiar with the cold, damp and dingy basement. Now, the Enclosure Conditioned Housing (ECHO) System TM, winner of the Ottawa-Carleton
Facts About Home Cooling
Facts About Home Cooling Energy Savings When keeping cool means air conditioning, keeping comfortable can often be expensive. Especially since air conditioning can add up to over 11% of your bill. But
RESIDENTIAL MASONRY A BEST PRACTICES GUIDE
RESIDENTIAL MASONRY A BEST PRACTICES GUIDE Build With Brick Build With Boral CONTENTS BRICK :01 MASONRY CEMENT :03 MASONRY SAND :04 WALL TIES :05 STEEL LINTELS :07 DRAINAGE WALL SYSTEM :09 FLASHING :11
Installation Instructions for Alarm Module Kit A043F059
Instruction Sheet 07-2013 Installation Instructions for Alarm Module Kit A043F059 1 Introduction The information contained within is based on information available at the time of going to print. In line
Name Of Occupancy Date. Yes No Describe
FIRE PREVENTION INSPECTION CHECKLIST For Class A Occupancy (For Assembly Buildings, Bars, Restaurants, Gyms, Churches, Arenas, Theatres or wherever people gather) Name Of Occupancy Date Physical Address
A TO Z HOME INSPECTIONS PROFESSIONAL HOME INSPECTION SERVICES FOR HOME BUYERS AND SELLERS
A TO Z HOME INSPECTIONS PROFESSIONAL HOME INSPECTION SERVICES FOR HOME BUYERS AND SELLERS Insurance Inspection Report 1234 Main Street Tallahassee, Florida Report Prepared For: Charles Smith Report Prepared
NCMA TEK CONCRETE MASONRY FOUNDATION WALL DETAILS. TEK 5-3A Details (2003)
NCMA TEK National Concrete Masonry Association an information series from the national authority on concrete masonry technology CONCRETE MASONRY FOUNDATION WALL DETAILS TEK 5-3A Details (2003) Keywords:
Self-Home Inspection Checklist
To be used as a first home visit for note taking. Visit www.homeinspectiondirect.com for more tips and information about buying a home and hiring a home inspector. This form in no way replaces a professional
solutions & tips six Wise Energy Guide Building envelope solutions and simple tips AIR SEALING
Wise Energy Guide solutions & tips 32 AIR SEALING Is your house leaking money? six Building envelope solutions and simple tips If your home is like most, the greatest amount of heat loss is from air leakage;
Guidelines for Earthquake Bracing of Residential Water Heaters
Guidelines for Earthquake Bracing of Residential Water Heaters Department of General Services Division of the State Architect 1102 Q Street, Suite 5100 Sacramento, CA 95814 Phone: (916) 324-7099 Fax: (916)
Chimney systems ICOPAL WULKAN C/CI/C-eko/CI-eko
INSTALLATION MANUAL Chimney systems ICOPAL WULKAN C/CI/C-eko/CI-eko Ventilated Notified entity Building Technical and Research Institute Prague notification no. 1020 This instruction refers to double-layer
Guidelines for Earthquake Bracing Residential Water Heaters
Guidelines for Earthquake Bracing Residential Water Heaters Department of General Services Division of the State Architect In accordance with the Health and Safety Code Section 19215, the Division of the
presents Cooking With Fire Fixed Fire Suppression & Exhaust Systems for Cooking Environments Monday, 17 June, 13
presents Cooking With Fire Fixed Fire Suppression & Exhaust Systems for Cooking Environments Who is the AFSA? Safe and Secure Alberta Fire Safety Association Fire industry members working together to improve
How To Build A Basement House
Single Family Basement Finish Purpose of Guide The purpose of this guide is to assist you in the permit process for your project. This handout is intended as a basic plan submittal under the 2009 International
Elevating Your House. Introduction CHAPTER 5
CHAPTER 5 Elevating Your House Introduction One of the most common retrofitting methods is elevating a house to a required or desired Flood Protection Elevation (FPE). When a house is properly elevated,
FOUNDATION INSULATING SYSTEM, INCLUDING WATERPROOFING AND DAMP PROOFING
FOUNDATION INSULATING SYSTEM, INCLUDING WATERPROOFING AND DAMP PROOFING insulation installed on foundation walls must be separated from the building interior with a code approved thermal barrier. Foam
Arapahoe County Residential Water Heater Installation and Inspection Guide
Arapahoe County Residential Water Heater Installation and Inspection Guide The attached handout is designed to be a general permit submittal and inspection guide covering most installation instances, however
Protecting Your Home From Hurricane Wind Damage
T H E W I N D Protecting Your Home From Hurricane Wind Damage During a hurricane, homes may be damaged or destroyed by high winds and high waves. Debris can break windows and doors, allowing high winds
Controlling moisture. For your home. Bellevue, WA 98009-9734. Puget Sound Energy. pse.com/myrebates. P.O. Box 97034 1210 02/14
Controlling moisture For your home 1210 02/14 Puget Sound Energy P.O. Box 97034 Bellevue, WA 98009-9734 pse.com/myrebates Control the moisture in your home In this guide 3 Control the moisture in your
Residential Roofing Guide
Residential Roofing Guide TABLE OF CONTENTS Building Detail and Accessories...... 1 Panel Introduction and Handling...... 2 Cutting and Trimming.... 3 Roof Preparation..... 3 Roof Slope..... 3 Re-roofing...
www.citiesinspection.com October 5, 2015 Dear Client,
www.citiesinspection.com October 5, 2015 Dear Client, On 9/14/2015, Cities Inspection Service, Inc. completed a building inspection of the property located at 123 Oak Street, Someplace, Minnesota for you.
LIFE SAFETY UPDATE. FULL SPRINKLERING OF ALL NURSING FACILITIES ADDITIONAL CLARIFICATIONS Prepared by Eric Rosenbaum, P.E. Hughes Associates, Inc.
LIFE SAFETY UPDATE FULL SPRINKLERING OF ALL NURSING FACILITIES ADDITIONAL CLARIFICATIONS Prepared by Eric Rosenbaum, P.E. Hughes Associates, Inc. The purpose of this update is as follows: Remind all state
Firefighter Review. Instructor Guide
Firefighter Review Instructor Guide Session Reference: 3 Topic: Attack Line Handling Level of Instruction: Time Required: Three Hours Materials: Two Fully Equipped Pumpers Structure for Use in Advancing
CITY OF WHITE BEAR LAKE BUILDING INSPECTION DEPARTMENT 4701 Highway 61 White Bear Lake, MN 55110 Fax: 651-429-8503. Re-Roofing: Asphalt Shingles
CITY OF WHITE BEAR LAKE BUILDING INSPECTION DEPARTMENT 4701 Highway 61 White Bear Lake, MN 55110 Fax: 651-429-8503 Re-Roofing: Asphalt Shingles This is a summary of the standard requirements based on the
Excerpts from the Canadian National Building Code (NBC)
Excerpts from the Canadian National Building Code (NBC) Reproduced here with Permission of the Copyright Owner, the National Research Council of Canada, Institute for Research in Construction. For more
Regulatory Services. Asbestos in the Home. What is asbestos?
Regulatory Services Asbestos in the Home What is asbestos? Asbestos is a natural silicate mineral consisting of fibres. The fibres are strong, durable, and resistant to heat, long, thin and flexible. There