GARAGE MAIN FLOOR PLAN

Similar documents
Custom 30 x 20-8 Garage Plan Plan #g233 By SDS-CAD Specialized Design Systems

POST AND FRAME STRUCTURES (Pole Barns)

Additions and Alterations

Mark Cramer Inspection Services, Inc.

Fig. 2 WALL-TO-WALL PANEL CONNECTIONS CORNER WALL CONNECTION

1/2" CDX PLY W/ 6"/ 6"/ 12" 2x ROOF 16"OC W/ R-30 BATT. INSUL. (COMMON NAILS)

Superform Products Ltd.

4. ANCHOR BOLTS AND STRAPS a. ½" anchor bolts shall be embedded 7" into concrete a maximum of 6' on center and 12" from corners and ends of plates.

Free 12 x 8 Shed Plan With Illustrations, Blueprints & Step By Step Details

SUPER SHED. Indoor shelter for your outdoor tools.

HURRICANE MITIGATION RETROFITS FOR EXISTING SITE-BUILT SINGLE FAMILY RESIDENTIAL STRUCTURES

Chapter 6 ROOF-CEILING SYSTEMS

STANDARD OPEN PATIO COVER

Page & Turnbull imagining change in historic environments through design, research, and technology

8/18/14. Introduction to. Framing. Terminology and Concepts

PDmB, Inc. Definitions

COMMONLY USED RESIDENTIAL BUILDING CODES

This handout is a guide only and does not contain all of the requirements of the Minnesota State Building Code or city ordinances.

Best Barns USA Assembly Book

RESIDENTIAL PLUMBING ALTERATIONS PERMIT REQUIREMENTS

March 14, Installation of Bay, Bow and Garden Windows

RESIDENTIAL ROOFING & RE-ROOFING, ROOF VENTILATION AND ROOF SHEATHING REQUIREMENTS MICHIGAN RESIDENTIAL CODE 2000

Pre-Drywall Inspection Report

TYPICAL PATIO COVERS 111

CONSTRUCTION DETAILS & LOAD DESIGN CHARTS

Residential Deck Safety, Construction, and Repair

Asphalt Shingle Application Requirements

NCMA TEK CONCRETE MASONRY FOUNDATION WALL DETAILS. TEK 5-3A Details (2003)

RESIDENTIAL FOUNDATION GUIDELINE Johnson County, KS

CLIENT. Inspection Report. 271 Front St. Alert Bay, B.C. Island Building Inspections V ANCOUVER I SLAND B. C.

Final inspections are completed by site visit only. Access to fenced yards shall be planned.

Section A Roof Truss

Whitley Manufacturing Co., Inc. 201 W. First Street S. Whitley, IN Phone (260) Sales Fax (260)

Residential Building Inspection Policies

Patio Covers / Carports

How to secure your property after a disaster

The better way to build TM. Installation Manual. FOUNDATION SIPs & FROST WALLS SIPs

Attached/Detached Patio Cover/Carport

1. Concrete: T W L / 27 = Concrete C.Y. Multiply Feet Thickness x Feet Width x Feet Length / 27 = Cubic Yards.

Basic Requirements for Residential Plan Review _

Formwork for Concrete

This handout is a guide only and does not contain all of the requirements of the Minnesota State Building Code or city ordinances.

DEFAULT HEAT LOSS COEFFICIENTS

NAVAJO COUNTY ADDENDA & ADDITIONS TO THE INTERNATIONAL BUILDING CODES. Public Works/Planning & Zoning Building & Safety AMENDED ( )

ISO Types 1-6: Construction Code Descriptions

Residential Decks. Planning and Development Services Department

INSTALLATION OF A BAY WINDOW

Pole Building Estimate Number: /2/2010 NORTH SIDE-EAVE SIDE 2 ELEVATION

Excerpts from the Canadian National Building Code (NBC)

Building Construction. Lightweight construction. Conventional Construction

PANELIZED HOME INSTALLATION GUIDELINE

REQUIREMENTS FOR SUBMITTING PLANS FOR NEW CONSTRUCTION

GreenGuard Housewrap Installation Guide

ROOF CONSTRUCTION Roof Styles Gable Roof Hip Roof Gambrel Roof

Building Construction. Structural Systems 1. Load-bearing wall construction 2. Skeleton framing 3. Combination of the two

Uncovered Decks & Porches

Chapter 36 - STRAW BALE CONSTRUCTION SECTION PURPOSE. SECTION SCOPE. SECTION DEFINITIONS.

HfHMD uses LP SmartSide siding and trim.

PANEL CONCEPTS LLLP.

AMERICAN GOTHIC PLAYHOUSE

STRUCTURAL CONCEPT FOR LIGHT GAUGE STEEL FRAME SYSTEM

2014 FLORIDA BUILDING CODE

The better way to build TM. Installation Manual. EXTERIOR WALL SIPs

INFORMATION BULLETIN NO.

Estimated Cost of Repair

CHAPTER 6 CONSTRUCTION TYPES

Carroll County Bureau of Permits and Inspection Residential Code Compliance Guidelines

A0 SHEET 1 OF LOCUST STREET FRANKFORT, KANSAS FRANKFORT, KANSAS ROOF REPAIR OF THE 400 LOCUST STREET

ROOFING APPLICATION STANDARD (RAS) No. 150 PRESCRIPTIVE BUR REQUIREMENTS

NRG 75 CRF NRG GREENBOARD WALL SYSTEM

INFORMATION BULLETIN NO.

CITY OF BERKELEY BUILDING PERMIT DETAILED CHECKLIST

CALIFORNIA BUILDING CODE

Footing and Temporary Power Inspection

Certification: Building Plans Examiner. Exam ID: B3

Engineered Wood Foundations

609 West Rock Road, Radford,VA / (fax) RECOMMENDED ATTACHMENTS & CONNECTION DETAILS

How To Repair A Boat Landing Deck With A Boat Bed

1997 Uniform Administrative Code Amendment for Earthen Material and Straw Bale Structures Tucson/Pima County, Arizona

Georgia Association of Home Inspectors

Typical Finished Basement Details

Building Information Packet

Sample Drawing Package for One and Two Family Dwelling Applications

Chapter 3 Pre-Installation, Foundations and Piers


DENVER MODEL 30 X 30 SPECIFICATIONS

TABLE OF CONTENTS. Roof Decks 172 B, BA, BV Deck N, NA Deck. Form Decks FD,.6 FDV Deck 1.0 FD, 1.0 FDV Deck 1.5 FD Deck 2.0 FD Deck 3.

CITY OF SELMA, TEXAS Inspection Checklist: Commercial

Detached accessory structures that contain no conditioned floor area are exempt.

Residential Foundations and Basements

Chapter 3 FOUNDATIONS AND FOUNDATION WALLS

6 RETROFITTING POST & PIER HOUSES

How To Make A House Safe

Envelope INSULATION BATT (2) Avoid Using Batt Insulation With Metal Framing. Pressure or Friction Fit

The Cabin Shell Series

Building Department John Fiedler Construction Official Ext SAMPLE GUIDE FOR 1&2 FAMILY DWELLING BASEMENTS Rev

ONE-STOP S PERMIT INFORMATION PACKAGE FOR RESIDENTIAL PROJECTS

PART 1 GENERAL 1.1 SECTION INCLUDES

Protecting Your Home from Wind Damage

THE DOW CHEMICAL COMPANY Issued: August 1, LARKIN CENTER 1605 JOSEPH DRIVE MIDLAND MICHIGAN (989)

Transcription:

12'-0" BUILDING CONTRACTOR/HOME OWNER TO REVIEW AND VERIFY ALL DIMENSIONS, SPECS, AND CONNECTIONS BEFORE CONSTRUCTION BEGINS. GARAGE TO BE BUILT AS PER IRC, UBC OR CURRENT LOCAL CODE To the best of my knowledge these plans are drawn to comply with owner's and/ or builder's specifications and any changes made on them after prints are made will be done at the owner's and / or builder's expence and responsibility. The contractor shall verify all dimensions and enclosed drawing. SDSCAD is not liable for errors once construction has begun. While every affort has been made in the preparation of this plan to avoid mistakes, the maker can not guarantee against human error. The contractor of the job must check all dimensions and other details prior to construction and be solely responsible thereafter. All calculations and member sizing should be verified for your building by a certified building official. 20'-0" 3'-6" 3'-0" 7'-0" 3'-0" 3'-6" 3068 WP Roll up Steel Door 6066 3'-0" 6'-0" 3'-0" 3'-6" 3'-0" 7'-0" 3'-0" 3'-6" 20'-0" P O Box 374 Mendon, Utah - www.sdscad.com - 43-73-1614 - John@hplans.us #G441 12' X 20' X 8', Workshop Garage By 12'-0" Page 1 Page 2 Page 3 Page 4 Page Page 6 Title Main Floor Plan Elevation Views Foundation Plan & Pictorials Framing and Details Detail Page Materials List 30 year dimensional shingles and horizontal siding over structural panel. Nailing schedule is 6" on ends 12" on centers 6d nails. Trusses are engineered trusses 24" o.c. framing is 2" x 4" on 16" centers. 8' ceiling height. SCALE 1/4"=1' GARAGE MAIN FLOOR PLAN @COPYRIGHT SDSCAD 1

REAR ELEVATION LEFT ELEVATION P O Box 374 Mendon, Utah - www.sdscad.com - 43-73-1614 - John@hplans.us FC 8'-0" 2'-" 10'-9" 4 /12 PITCH ENGINEERED TRUSS METAL ROING 8' Tall 2 x 4 Walls FF 4" 2'-0" DEPTH PER CODE Grade Finish to match Cottage Lap siding with 7" exposure Trim with pine boards Paint to match SCALE 1/4"=1' FRONT ELEVATION RIGHT ELEVATION 2 @COPYRIGHT SDSCAD

P O Box 374 Mendon, Utah - www.sdscad.com - 43-73-1614 - John@hplans.us 12'-0" 20'-0" FOUNDATION PLAN SCALE 1/4"=1' PICTORIAL VIEWS Concrete: 1. All slabs are to be 4" concrete over 4" gravel unless otherwise noted on the plans. 2. Concrete to be ACI 301-66, Type II cement, 200 psi at 28 days, " maximum slump. 3. If required reinforcing to be ASTM A61-Bars with Fy=60 ksi lamp 30 diameter minimum at splices or weld per ACI Std. 4. Concrete design based on Fc 2000 psf, Fc 200 psi for quality only.. Anchor bolts shall be A-307 embedded 7" minimum into concrete or masonry grout. 6. All footings minimum 24" below final grade 7. Sloped 1" per 10' to door Thickened edge slab 12" x 24" 3 @COPYRIGHT SDSCAD

General framing: (Douglas Fir) GARAGE RO PRE-ENGINEERED TRUSSES AS SUPPLIED BY TRUSS MANUFACTURER 24" o.c. 8' Tall 2 x 4 Walls Back Wall 1. Minimum header sizes shall be according to the following table unless otherwise noted. Header sizes (single story construction) 2'-0" to 4'-0" Span 2-2x4's 4' + to 6'-0" Span 2-2x6's 6' + to 8'-0" Span 2-2x8's 8' + to 10'-0" Span 2-2x10's 10' + to 12'-0" Span 2-2x12's or as noted on plan 2. Brace all exterior walls and cross-stud partitions at each end of building and at least every 2' of length by one of the following: a. Simpson WB 126 wall bracing with 3-16d nails at each end and 1-8d nails at each stud. b. Plywood sheathing of a minimum thickness of 7/16 inch. 3. Fire stopping: a. Fireblock stud spaces over 10' in height, furred spaces, soffits, drop ceilings, cove ceilings, stair stringers at top and bottom of run, bearing walls and ceiling joist lines, etc. Firestopping shall consist of 2" nominal lumber. b. Firestop openings around vents, pipes, ducts, chimneys, and fireplaces at ceiling and floor levels with approved noncombustible materials. 4. CDX plywood is not approved where exposed to weather, i.e., roof overhangs.. Exterior wall framing to be 2"x4" studs at 16" o.c. Interior wall, framing at non-bearing walls to be 2"x4" studs at 24" o.c. and at bearing walls 2"x4" studs at 16" o.c. with double top plate. 6. Shear wall to be 7/16" Sheathing, see detail. 7. All stress grade lumber shall comply with WCLA specs and bear approval stamp on all pieces in place. 8. Framing lumber shall be Douglas Fir construction grade Fb 140 or better unless otherwise noted. 9. Nailing to be per current U.B.C. unless otherwise noted. 10. All bearing partitions shall have double top plates. 11. Structural glued laminated timbers to be stamped by an approved agency. 12. Use redwood or pressure treated sole plates at all exterior walls. P O Box 374 Mendon, Utah - www.sdscad.com - 43-73-1614 - John@hplans.us Roof Framing: Cross Section Front Wall 1. Fascia to be 2"x Douglas Fir. 2. For soffit size see details. 3. For spans and dimensions refer to floor plans. 4. Trusses are to be an approved truss design from the truss manufacture's engineer.. Use Simpson H-1 hurricane anchors at each truss or rafter to wall connection. 6. Solid blocking required between joists, rafters, and trusses over all bearing walls. Such blocking shall be 1 ½" minimum thickness and full depth of joists, rafters, or trusses. 7. Minimum header sizes shall be according to the header size table unless otherwise noted. 8. Basis of design roof live/snow load of 37 psf, and roof dead load of 1 psf. 9. Plywood roof decking to be Min ½" thick, 24/0, CDX or /8 wafer. WALL FRAMING SECTIONS SCALE 1/8"=1' 4 @COPYRIGHT SDSCAD

SINGLE POUR CORNER INSTALLATION HPAHD straps for all () Alternate Braced Wall Panels See additional detail for all () Braced Wall Panels TYPICAL ALTERNATE BRACED WALL PANEL () GRADE 2 % MIN. SLOPE 6" MIN. THICKNESS CONCRETE WALL CORNER DISTANCE FROM EDGE STRAP TO CORNER Simpson Strong-Tie HPAHD 8" o o @32" MAX. SPACING. BOLTS SHALL BE EMBEDDED 7" MIN. 4" CONC. SLAB Footing and concrete wall option Bottom of footing to be a min of 12" below grade or as required by local code NOTE: TYPICAL DETAILS FOR CONSTRUCTION TO MEET BUILDING REQUIREMENTS. GARAGES TO BE BUILT AS PER LOCAL CODE REQUIREMENTS 4" COMPACTED GRAVEL 1/2" ANCHOR BOLT 32" O.C. ASPHALT SHINGLES OVER 30# FELT 7/16" SHEATHING SIMPSON H1 TRUSS CLIP 1 x 6 FASCIA CDX PLYWOOD SHEAR WALL INSTALLED W/ LONG DIMENSION ACROSS STUDS. STAGGER VERTICAL JOINTS PANEL SHEATHING USED AS CORNER BRACING W/ LONG DIMENSION PARALLEL TO STUDS SIDING MATERIAL STRUCTURAL PANEL CAN ACT AS SIDING IF EXTERIOR GRADE PRE-ENGINEERED TRUSSES @ 24" O.C. 2 x STUD @ 16" O.C. LEAVE 1/4" GAP @ EDGES & 1/8" GAP @ ENDS UNLESS OTHERWISE REC- OMMENDED BY MANUFACTURER WALL FRAMING 10d NAILS @ 6" O.C. AT EDGES & SEAMS AND 10d NAILS @ 12" O.C. IN FIELD U.N.O. ON SHEAR WALL SCHEDULE TYPICAL BRACED WALL PANEL () 12 4 12" Min P O Box 374 Mendon, Utah - www.sdscad.com - 43-73-1614 - John@hplans.us 4" CONCRETE SLAB 7/16" MIN STRUCTURAL SHEATHING VAPOR BARRIER 4" GRAVEL BASE 6" MIN. GRADE 12" X 18" DEEP CONT. CONCRETE THICKENED EDGE SLAB 2 x MUDSILL 1/2" x 10" ANCHOR BOLT EMBEDDED 7" INTO CONC. 4" CONC. SLAB OVER 4" GRAVEL SLOPE TO OUTSIDE Monolithic slab foundation option GARAGE TYPICAL SECTION DETAILS @COPYRIGHT SDSCAD

@COPYRIGHT SDSCAD Computer generated materials list from the computer model a great place to start with your material requirements. General GN1 1 96 high wall Siding-4 63 0 ft GN2 1 heated ceiling area 240.00 0.00 sq ft GN3 1 heated floor area 240.00 0.00 sq ft GN4 2 22 13/16 high wall Siding-4 22 0 ft Foundation FO1 1 240 sq ft concrete slab 2.96 0.00 cu yd FO2 1 240 sq ft steel mesh for slab 240.00 0.00 sq ft FO3 1 1/2x6" foam sill seal 64 0 ft FO4 1 foundation bolts 12 0 FO 1 16x20"h concrete footing 4.83 0.00 cu yd FO6 1 no. 4 rebar (footing) 121 0 ft Framing F1 1 2x4-16ft+ fir plate 198 0 ft F2 1 2x4"-91 1/2" fir stud 1 0 F3 1 2x4-16ft+ fir stud stock 104 0 ft F4 1 2x12-16ft+ header - lumber 27 0 ft F 1 2x4"-2 3/4" fir stud 0 F6 1 2x11-16ft+ header - lumber 13 0 ft F7 2 2x4-16ft+ fir plate 47 0 ft F8 2 2x4-16ft+ fir stud stock 28 0 ft Siding S1 1 7" wide Siding Wood White 1037 0 ft S2 1 house wrap 19.00 0.00 sq ft S3 2 7" wide Siding Wood White 49 0 ft Ext Trim EX1 0 4" thick - concrete grey 7.41 0.00 cu yd EX2 1 1x4-16ft+ exterior sill 11 0 ft EX3 1 1x4-16ft+ ext. window casing 32 0 ft EX4 1 1x4-16ft+ garage door casing 20 0 ft EX 1 in garage door jamb 20 0 ft EX6 1 1x-36" door threshold 1 0 EX7 1 1x4-16ft+ ext. door casing 17 0 ft EX8 1 in ext. door jamb 17 0 ft Roofing R1 1 16" roof truss 11 0 R2 1 2x8"-16'+ ridge board - lumber 22 0 ft R3 1 2x7"-22' rafters - lumber 2 0 R4 1 2x7"-16'+ rafters - lumber 30 0 ft R 1 2x4"-16'+ rafters - lumber 23 0 ft R6 1 ridge cap 22 0 ft R7 1 Roofing Corrugated Metal 32.00 0.00 sq ft R8 1 4x8' sheets roof sheathing 11 0 R9 1 2x8" gable fascia 30 0 ft R10 1 2x8" eave fascia 44 0 ft R11 1 metal drip edge 74 0 ft Insulation IN1 1 12x24x48" batts ceiling insulation 30 0 IN2 1 12x16x48" batts floor insulation 4 0 Wall Brd WB1 1 4'x8'x1/2" Sheet Sheetrock 16 0 WB2 1 Color Bone White 219.00 0.00 sq ft WB3 1 4'x8'x3/4" Sheet Sheetrock 7 0 WB4 2 4'x8'x1/2" Sheet Sheetrock 1 0 Windows W1 1 36x38 double hung 3 0 W2 2 14x6 14x6 Horiz 2 0 Doors D1 1 72x78 garage 2-Panel Garge Door 1 0 D2 1 handle: Lever (decorative) 1 0 D3 1 handle: Exterior Handle (ext.) 1 0 D4 1 lock: Dead Bolt (interior) 1 0 D 1 lock: Dead Bolt (exterior) 1 0 D6 1 hinge: hidden 3 0 D7 1 36x80x1 3/4R ext. 6-Panel - color white 1 0 Int Trim T1 1 1x4-16ft+ window apron 11 0 ft T2 1 1x4-16ft+ sill 11 0 ft T3 1 1x4-16ft+ interior casing 49 0 ft Electrical E1 1 wall mount Duplex 0 E2 1 wall mount Caged Lantern 3 0 E3 1 wall mount Single Pole 2 0 E4 1 wall mount Duplex (weatherproof) - color light gra 1 0 E 1 ceiling mount Half Dome Light - lighting grey 2 0 Total: REVISIONS P O Box 374 Mendon, Utah - www.sdscad.com - 43-73-1614 - John@hplans.us