Dew-Point Measurement Solutions



Similar documents
Relative Humidity Sensors, Transmitters and Calibration Products Relative Humidity Measurement and Calibration

Rense Product Range. Customized Humidity Solutions. Rense Product Range

EASIDEW PORTABLE HYGROMETER INSTALLATION, OPERATION AND MAINTENANCE MANUAL

Liquidew EExd Moisture in Liquids Analyzer

Condumax II Hydrocarbon Dew-Point Analyzer

Micro Motion 3098 Gas Specific Gravity Meter

The Breather Box. High Performance Grade-D Breathing Air Filtration system. BB50-cO

Models SFP33 & SFP32 Pressure Transmitters

DM70 Hand-Held Dewpoint Meter for Spot-Checking Applications

S300 Series Dust Monitors

Humidity and Dew-Point Calibration

Plastic tube flowmeters Series PT/PS

How To Use A Ds340 (Dsp)

How is Dew Point Measured Reliably?

FCI M180 Series: Custom Engineered Flow and Level Sensors for OEM Applications

Application Requirement

EuroFID Total Hydrocarbon Analyzer. Precise Determination of Total Hydrocarbons in Air for Corrosive as well as Condensing Gases

Ventostat Wall Mount. Telaire Wall Mount CO 2. , Humidity and Temperature Transmitters. GE Measurement & Control. Features:

MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter

The PACE5000 Modular Pressure Controller/Indicator

Process Instrumentation

AT500 Magnetostrictive Level Transmitter. Compact magnetostrictive liquid level transmitter for direct insertion K-TEK Products

Pro Dry Heatless dessiccant compressed air dryers

Continuous Monitoring of Flue and Combustible or Hazardous Gases and Vapors

A beginner s guide to humidity measurement

FLARE MONITORS FLARE MONITOR (FM) PILOT MONITOR (PM) FLAME INTENSITY (FI)

Kompressoren. Adsorption Dryer AD

G8 GALILEO. Innovation with Integrity. High-End Melt-extraction Analyzer. Inert Gas Method

Environmental Equipment, Inc. IMR 5000 Continuous Flue Gas Monitoring System IMR 5000

Adsorption air dryers ADS 1 215

Mobrey Ultrasonic. MSP900SH Level and MSP900FH Flow Transmitters. Product Data Sheet February 2015 IP2032, Rev BA

713 Open Channel Flowmeter and Transmitter. All-in-one package for open channel flow measurement.

Engineered Solutions

Instruction Manual. T3111 T3111L T3111P T3111Ex

USB-500/600 Series Low-Cost Data Loggers and Accessories

USB-500 Series Stand-Alone, Low-Cost Data Loggers

Flow switches Series AD/VH

COMBIMASS. Technical Data COMBIMASS eco-bio +

Certified according to DIN EN ISO 9001 Technical Datasheet TRICOR Series Mass Flow Meters

OXIGENO DISUELTO. Dissolved Oxygen. Install & forget. Sistema autolimpiable. Autoclean system

Medical Air Systems: Scroll

Fundamentals of Mass Flow Control

450TOC Analyzer. Portable, Real-time, Continuous Total Organic Carbon Measurement. 450TOC Analyzer

Online Infrared Flue Gas Analyzer Gasboard 3000

How To Use An Irius Pid Detector

Tadahiro Yasuda. Introduction. Overview of Criterion D200. Feature Article

Flow Monitoring System

Externally Heated Desiccant Compressed Air Dryers PNEUMATIC PRODUCTS. PHD Series. pneumaticproducts-spx.com

Technical data sheet TDS0070

Trace Gas Exchange Measurements with Standard Infrared Analyzers

CPX/HT Series. REFRIGERATED AND HIGH TEMPERATURE DRYER 12 to 2400 CFM. High-performance products. Designed for you!

LeakFilm. Protecting your high-tech assets with innovative, user-friendly technology for liquid leak detection

Displays. Cathode Ray Tube. Semiconductor Elements. Basic applications. Oscilloscope TV Old monitors. 2009, Associate Professor PhD. T.

Typical Aluminum GFM Mass Flow Meter

Atlas Copco. On-site Industrial Gases Nitrogen & Oxygen Generators

Dew Point Tester. Instruction Manual. CVS Regular Chiller Model A-2. CVS Regular Chiller Model A-2

OEM Optical Competences. Solutions for Optical OEM Applications in Liquid Analysis.

The NEW Advanced Range of Portable Temperature Calibrators PROVISIONAL. Portable Dry Blocks, Liquid Baths and Multi-functional Heat Sources

FMA 3100/3100ST/3300/3300ST Series Thermal Mass Flow Sensors and Meters

Regards from the Team at Rheology Solutions.

Certified according to DIN EN ISO 9001 Technical Datasheet KVO Series Vortex Flow Meter

INTA Renewable Energy Area activities

FGM 160 ATEX EC type examination certificate

SEISMIC VELOCITY TRANSDUCER T1-40

Precision Humidity Measurement for Pharmaceutical Fluid Bed Tablet Coating

Air Pollution Control Division. Technical Services Program

Pressure Dew Point Probe / Application Information

DrägerSensor EC Electrochemical Sensors Sensor for Fixed Gas Detectors

Validation of process gas systems

nvision Reference Recorder

ThermoSorb Desiccant Dryers

For Multi-Parameter Meters see mvx

Advanced Solutions for Gas Monitoring

Lockout Specification BW Clip Maintenance-free single gas detector

The photoionization detector (PID) utilizes ultraviolet

Triple Waveband Infra-Red Flame Detection

ORGANIC SAMPLE PREPARATION

Reliability Accuracy Performance

USB-500 Series Low-Cost Data Loggers and Accessories

Electronic Flow Switches

Explosion proof enclosures

CONTAMINATION CONTROL FOR ELECTRONIC AND SEMICONDUCTOR APPLICATIONS

ETC TWO STAGE ELECTRONIC TEMPERATURE CONTROL

2/ These vacuum switches are used in measuring ranges between -1 and 0 bar.

LANCOM4 PORTABLE FLUE GAS MONITORING. NO NO2 NOx CO2 H2S SO2 CxHy. CO low CO high O 2 QUALITY CUSTOMER SOLUTIONS

Traceable Moisture Measurements by Means of Residual Water Detection

Thermal flow sensors TA10-ZG8c and TA10-ZG9c for exact and stable, long-term measuring of lower flow velocities (Laminar Flow)

Title: Standard Operating Procedure for Thermo-Miran SapphIRe portable gas analyzer

WEATHER STATION FOR SOLAR FARM MONITORING

PRODUCT REVIEW. Flowmeters and Controllers. Vacuum Instrumentation

Isolating Barriers for our sensors A5S1 in Ex-areas Series D461

MATHESON REFINERY PROGRAM for Specialty Gas Supply. Experience the MATHESON Commitment to Supply Chain Excellence

The Ambient Air Monitoring System

Contamination Control and Environmental Monitoring Systems

This paper describes Digital Equipment Corporation Semiconductor Division s

Kompressoren. Compressed Air Filters PF/DF/MF/SF/AF

Mass Flow Meters & Controllers

Transcription:

Dew-Point Measurement Solutions www.michell.com

Dew-Point Measurement Solutions Special Features No downtime Michell Instruments offers a unique sensor exchange programme, which means that you will never need to be without fast and accurate humidity measurement. Speed Ceramic Sensors yield the fastest response time. Resilience Ceramic Sensors are very robust and offer excellent corrosion resistance as well as being highly resistant to sudden pressure changes. Safety Michell s Impedance range offers intrinsically safe versions of each instrument. Low Cost Michell s Easidew range of hygrometers is one of the most affordable on the market. Calibration All Michell s instruments are supplied complete with calibration certificates traceable to national standards, to ensure accurate and stable measurements. Background to Michell Instruments Michell Instruments is the global leader in moisture and humidity measurement solutions. With over 30 years of experience, Michell Instruments designs and manufactures a wide range of transmitters, instruments and system solutions capable of measuring trace moisture, humidity, dew point and oxygen in a vast range of applications and industries ranging from compressed air dryers, power generation, process, natural gas, pharmaceutical, plastics and many more. With a fast growing international subsidiary and distribution network, Michell Instruments provides cost effective measurement solutions for the most demanding applications around the world. Applications Air Dryers Aerospace Environmental Chambers Food/Beverage Processes Power Generation Chemical Natural Gas Metallurgy/Heat Treating Pure Gases Petrochemical Metrology Laboratories Automotive Pharmaceutical Drying Processes Plastics Semiconductor Fabs Fuel Cells and many more Michell uses four key dew-point measurement technologies in their products: Impedance method using a ceramic tile which delivers unrivalled speed of response and robustness. Chilled mirror method which has been incorporated into advanced, precision instruments for industrial and laboratory use. Dark spot technology, which was developed in partnership with Shell, to offer a world-class solution for the measurement of hydrocarbon dew point. Quartz crystal technology for a high-precision, fast responding moisture measurement with self-calibration. 2012 Michell Instruments

Sensor Technology All Michell dew-point transmitters use the Advanced Ceramic Moisture Sensor. The operation of this sensor depends on the dielectric property of water molecules absorbing onto an active porous insulating layer sandwiched between two layers of conductive material deposited on a ceramic substrate. Water has a very high dielectric compared to the dielectric of the active layer and the background of the carrier gas so it can be detected easily. The active layer is very thin less than one micron and the porous top conductor that allows water molecules to penetrate into the active layer is less than 0.1 micron thick. This allows the sensor to respond very rapidly to changes in the moisture surrounding it both when moisture decreases (drying) and increases in the sensor environment. Permeable Gold film Hygroscopic Mono-layer Base Electrode Ceramic Substrate Moisture Molecules Michell ceramic sensor tile layers 2012 Michell Instruments

Transmitters Fast response time (T90 in 4 min) High accuracy (±1 C available ) Unique Michell calibration exchange programme no downtime Linear 0-20 and output Multiple ranges within the total range of -100 to +20 C (-120 to -40 C for Pura) Work in pressures from vacuum to 45 MPa (450 Barg) FM, CSA and ATEX certified Small and easy to install Semiconductor industry surface preparation (Pura) On-line Hygrometers C, dew point & ppm, moisture content User configurable alarms and outputs Analog and digital outputs 4 or 5-Digit red sunlight readable display For additional specifications, request a specific data sheet Sampling Systems Sample filtration to avoid contamination and ensure reliable measurements Flow Control IP66 enclosures Pressure or atmospheric dew point www.michell.com

Easidew Transmitter dew-point transmitter Easidew On-Line Dew-point measurement and display instrument Easidew TX I.S. ATEX certified dew-point transmitter Easidew PRO I.S ATEX certified dew-point transmitter Easidew Sampler Self-contained sampling block with filter Connection Alarms Display Ingress Protection ATEX Certification Connection Certification Connection Pressure Flow Rate Gas Connections Filter ±2 C dew point 12-28 VDC 2 user configurable set points 4 digit red LED IP65 (front panel) 85-265 VAC, 24 VDC ±2 C dew point Ex II 1 G Ex ia IIC T4 12-28 VDC ±1 C dew point ATEX Ex II 1 G Ex ia IIC T4 FM I.S. I 1 ABCD T4 (Ta = +60 C) CSA IS Class 1 Div 1 Groups ABCD T4 12-28 VDC 0-1 MPa (0-10 Barg) 1-5 l/min Quick Connect for 6 mm OD PTFE Tube 99.95 % retention of 0.3 microns Pura Trace moisture measurement transmitter with integral sampling block Cermet II On-Line Hygrometer with multiple units of measurement -120 to -40 C dew point ±1 to ±4 C (range dependant) or RS485 Pressure Rating 10-9 torr to 240 Barg Flow Rate 1-5 l/min Parameters C / F dew point, ppm, g/m 3 Alarms Up to 4 user configurable set points Display 5 digit red LED 85-265 VAC, 24 VDC ES10 Simple sampling systems for Easidew instruments Dew Point Pressure Flow Rate Filtration Ingress Protection -60 to +40 C dew point 0-1 MPa (0-10 Barg) 1-10 l/min Particulate or coalescing Up to IP66 www.michell.com

Michell Instruments operates in the following markets: Compressed Air Dryers Pharmaceutical Standards Laboratories and Metrology Semiconductors Natural Gas and Petrochemicals Industrial and Pure Gas Production Power Generation Other Product s Portable Instruments Michell s range of easy-to-operate portable instruments provides fast, accurate and stable measurement of dew point, relative humidity and moisture concentration. They are designed to satisfy the most demanding industrial conditions, and are unique in the market for giving repeatedly fast response to low dew points. Chilled Mirror Instruments Chilled Mirror is a fundamental measuring technology offering the user exceptionally accurate, reliable and repeatable measurements from trace moisture to high humidity. Michell offers a range of instruments based on a rugged sensor design that is equally suitable for installation in demanding process environments or for use as an accurate reference instrument in a National Standards Laboratory. Process Analyzers Michell s range of analyzers is specifically designed to provide reliable online measurement in process applications such as dedicated water and hydrocarbon dew-point determination in natural gas. Three sensing technologies are used: the Ceramic Impedance sensor for measurements in gas and liquid phase; Quartz Crystal Microbalance for trace moisture in process gases and the Dark Spot Chilled Mirror for hydrocarbon dew point. Calibration Instruments Michell has a wide offering of calibration equipment for the verification of trace moisture, dew point and relative humidity sensors. A modular concept means that Michell s engineers can build a customised calibration solution that meets your exact needs. Components may include air compressor and dryer; low range or high range humidity generator; simple sensor housing or environmentally controlled test chamber and finally, verification using a traceable Michell Chilled Mirror Hygrometer. Oxygen Analyzers Michell brings you the very latest technologies in oxygen measurement, designed to give years of reliable and accurate service in laboratory, process and flue gas applications. From instruments featuring a unique sealed reference zirconia sensor to a transmitter with the latest generation thermo-paramagnetic oxygen technology, all Michell oxygen analyzers are available in a range of different configurations. Relative Humidity Instruments Michell s own RH sensing technology provides excellent resolution, longterm stability and speed of response. We offer a wide range of humidity and temperature measuring sensors and instruments, including relative humidity transmitters, humidity and temperature transmitters as well as handheld indicators. The humidity generator range includes the most stable humidity generator on the market. Michell Instruments 48 Lancaster Way Business Park, Ely, Cambridgeshire, CB6 3NW Tel: +44 (0) 1353 658000, Fax: +44 (0) 1353 658199, Email: uk.info@michell.com, Web: www.michell.com/uk Michell Instruments adopts a continuous development programme which sometimes necessitates specification changes without notice. Issue no: Dew Point Transmitters_97139_V5_UK_0112 2012 Michell Instruments