Variable speed drives Altivar 61

Similar documents
GE Energy Industrial Solutions. New. AF-6 Series Drives. Built-in features Built-in simplicity. GE imagination at work

Variable Speed Drives

Easy to connect - Easy to configure Easy to install

The HVAC SOLUTION DELIVERING POWER...SAVING ENERGY

NXL Series Inverters. HVAC Inverters made simple

Altivar 212 Drive. Selection Guide. Make the most of your energy SM

Number 1 in efficiency

VARIABLE FREQUENCY DRIVES Revised 4/30/ Mechanical Systems

ABB PSPS Erich Steinmann; Generator control-2013

Products and solutions for lifting systems

ABB general machinery drives. User s manual ACS355 drives

Permissible ambient temperature Operation Storage, transport

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs

vacon 100 x & vacon 20 x decentralized ac drives

Electronics Ltd. Presenting. Power, Intelligence... with a sense of feeling

40.3. Control Relays and Timers

Variable speed drives

INDUSTRIAL AUTOMATION EQUIPMENT EDITION

AC Drive Solutions. We Engineer Uptime

... Electronic Softstarter...

BT300 HVAC Drives Conventional Bypass (C-Bypass) Options

ABB machinery drives. User s manual ACS355 drives

HVAC DRIVE H300 HVAC Drive for Building Automation

Specifying a Variable Frequency Drive s

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

SmartVFD HVAC and BYPASS

DC UPS. RTB.e A. IMB.e/ITB.e kva. E2001.e/E3001.e kva. Input voltage: 110/125/220 Vdc. 115/120/230 Vac, 1-phase (IMB.

vacon 100 hvac for indoor climate control

BIG SAVINGS FOR A LOT MORE APPLICATIONS

Products and solutions for pumping, irrigation and piping

32VFD Variable Frequency Drives for Centrifugal Chillers

PUMP CONTROL. AC Variable Speed Drive PUMP CONTROL. Energy efficient pumping with. 0.75kW 250kW / 1HP 350HP V Single & 3 Phase Input

Optimize your simple machines... Modicon M218 Selection Guide

CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE. General purpose single phase thyristors and solid state relays Product data.

Phone: Fax: Web: info@clrwtr.com

CompactLogix Power Supplies Specifications

MLC TM Maximum Productivity and Versatility for Control without Compromise!

Low voltage AC drives. ABB industrial drives ACS800, single drives 0.55 to 5600 kw Catalog

Variable speed drives

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

AC Variable Speed Drive. Powerful Performance. Advanced motor control. 0.75kW 250kW / 1HP 350HP V Single & 3 Phase Input

Bulletin 150 SMC Flex Smart Motor Controller Specifications

vacon compact ac drives creating perfect harmony


Thyristor-controlled power supplies and battery chargers

HVAC BUILDING SERVICES

Process Alarm Solutions

Square D Model 6 Motor Control Centers

Technical Description. Transistor D.C. Chopper Controller Type GS 24 S

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

3466 Building Energy Management Training Systems

Telemecanique Drives Solutions. from BPX. Edition 2. The brochure from BPX with everything you need to know about Telemecanique Variable Speed Drives

vacon 100 hvac premium ac drive for indoor climate control

Quick Connect. quick - simple - efficient.

MC Series Drives. Flexible, simple, rugged, robust! Phone: Fax: Web: info@actechdrives.

CPU systron S S S 250c. systron S S S 250c. CPUs to the process modules. Stand-alone PLC

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

HVAC03C2 HVAC61C2 HVAC03C5 HVAC61C5 NXL HVAC INVERTERS

Preset Counter signo 721

LIFT CONTROL SYSTEMS CATALOGUE 2007

vacon compact ac drives creating perfect harmony

Using installed Fieldbus Wiring to carry Ethernet Communications

Remote Monitoring and REC 501 Control Unit Product Guide

Analog Servo Drive 25A8

Easily connect your switchboards to facility management solutions

Climasys Thermal Management System. Schneider Electric Universal Enclosures 2009

EFC Frequency converters

Silvertel. Ag Features. 2 Description. Power-over-Ethernet Plus Module. IEEE802.3at and IEEE802.3af compliant. Maximum 30W output power

TX OPEN RS232/485 module

PRODUCT PROFILE FEATURES

Thermistor motor protection

VLT Series 3500 Adjustable Frequency Drive Instruction Manual

Product Information Fire alarm panel 8000 C

Photovoltaic Solar Energy Unit EESFB

Installation manual. Generator Paralleling Controller GPC multi-line C

Frequency Converter Fv

SmartPro 230V 1000VA 900W Line-Interactive Sine Wave UPS, SNMP, Webcard, 2U Rack/Tower, USB, DB9 Serial

Features. Display. Measurements. Intelligent. Accuracy. Models. Installation DEIF A/S. Multi-instrument D

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start * see variants. Applications.

PSR The compact range Description

Digital input modules

Transformerless UPS systems and the 9900 By: John Steele, EIT Engineering Manager

Foxboro Evo Process Automation System

How To Use The Vacon 0 Machinery

Siemens AG 2011 SINAMICS V60. The perfect solution for basic servo applications. Brochure May 2011 SINAMICS. Answers for industry.

TLK 48 MICROPROCESSOR-BASED DIGITAL ELECTRONIC REGULATOR

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:

SECTION VARIABLE FREQUENCY DRIVES

mecotron Safety relay ESTOP-2 For emergency stop monitoring

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC A - M8 connector

Electronic Control Devices The European Product Catalogue 2007

Application/Connection Examples

ABB central inverters PVS to 1000 kw

ABB drives. Automation solutions Drives, PLC, motion, motors and safety

Voltage Regulator SPAU 341 C. Product Guide

Temperature & Humidity SMS Alert Controller

4.0 UPS dedicated to ICT for unmatched energy savings

Power Meter Series 700

ACS-30-EU-EMDR-10-MOD

Transcription:

Variable speed drives Altivar 61 Technical Description for Altivar Engineered Drives For 3-phase asynchronous motors from 90 up to 2400 kw

Table of content: 1. General Description:... 3 2. Standards:... 3 3. Basic offer includes:... 3 4. Control inputs:... 4 5. Control outputs:... 4 6. Communication:... 4 7. Standard functions:... 4 8. Protection functions:... 4 9. Options:... 5 10. Technical Data 400V range:... 6 400V / 90kW... 6 400V / 110kW... 7 400V / 132kW... 8 400V / 160kW... 9 400V / 220kW... 10 400V / 250kW... 11 400V / 315kW... 12 400V / 400kW... 13 400V / 500kW... 14 400V / 630kW... 15 400V / 630kW... 16 400V / 710kW... 17 400V / 900kW... 18 400V / 1100kW... 19 400V / 1300kW... 20 400V / 1400kW... 21 11. Technical Data 500V range:... 22 500V / 90kW... 22 500V / 110kW... 23 500V / 132kW... 24 500V / 160kW... 25 500V / 200kW... 26 500V / 250kW... 27 500V / 315kW... 28 500V / 400kW... 29 500V / 500kW... 30 500V / 630kW... 31 500V / 630kW... 32 500V / 800kW... 33 500V / 900kW... 34 500V / 1100kW... 35 500V / 1300kW... 36 500V / 1500kW... 37 500V / 1800kW... 38 12. Technical Data 690V range:... 39 690V / 110kW... 39 690V / 132kW... 40 690V / 160kW... 41 690V / 200kW... 42 690V / 250kW... 43 690V / 315kW... 44 690V / 400kW... 45 690V / 500kW... 46 690V / 630kW... 47 690V / 800kW... 48 690V / 800kW... 49 690V / 1000kW... 50 690V / 1200kW... 51 690V / 1500kW... 52 690V / 1800kW... 53 690V / 2100kW... 54 690V / 2400kW... 55 Schneider Electric - Altivar 61 - Technical Description for Altivar Engineered Drives Page 2 of 55

1. General Description: The Altivar ATV61EX concept offers customized ready-to-connect cubicles based on a modular assembly system that enables them to be optimally adapted to the individual plant conditions. Altivar 61 engineered drives can be supplied ready-assembled in an IP 23 or IP 54 floor-standing enclosure to facilitate installation and setup and, in particular, to ensure optimum ventilation. The modular assembly system provides for a number of options that can be selected as required. These include extensions to the line income and motor outlet, various control and protection options as well as cubicle heating, lighting and additional terminals for motor standstill heating or external motor fans. 2. Standards: Altivar 61 drives have been developed to conform to the strictest international standards and the recommendations relating to electrical industrial control devices (IEC, EN), in particular: IEC/EN 61800-5-1, low voltage IEC/EN 61800-3 (conducted and radiated EMC immunity and emissions). EMC Immunity IEC/EN 61800-3, environments 1 and 2 IEC/EN 61000-4-2 level 3 IEC/EN 61000-4-3 level 3 IEC/EN 61000-4-4 level 4 IEC/EN 61000-4-5 level 3 IEC/EN 61000-4-6 level 3 Conducted and radiated EMC emissions for drives IEC/EN 61800-3 CE Marking The drives have e marking in accordance with the European directives on low voltage (2006/95/EC) and EMC (89/336/EEC). Protection degree IEC/EN 61800-5-1, IEC/EN 60529 Environmental conditions IEC 60721-3-3 class 3C2 and 3S2 3. Basic offer includes: Standardised cubicle dimensions based on SAREL S6000 series a choice of three different protection degrees - IP23 for standard environment conditions - IP54 with filter fans for increased demand to protection against environmental influences - IP54 with separate air flow filterless construction to cool the power losses of the inverter, only a small filterblower needed for the control losses - IP55 liquid cooled with completely encapsulated cubicle for roughest environment Power modules mounted on rails Generous space for power cable connection Tested and approved cooling system Swing frame for further control option Graphical keypad mounted in cubicle door Reactor to reduce the current harmonics EMC filter for 2 nd environment Superfast fuses Load break switch Braking transistor up to 220 kw Customer specific documentation Schneider Electric - Altivar 61 - Technical Description for Altivar Engineered Drives Page 3 of 55

4. Control inputs: 5 programmable logic input 24 V DC, compatible with level 1 PLC, 1 logic input, switch-configurable as a logic input or as an input for PTC probes 1 input for the Power Removal safety function according to EN 954-1 / ISO 13849-1 and/or for thermal protection of the ATEX motor in applications in explosive atmospheres 1 bipolar differential analog input ± 10 V DC 1 software-configurable voltage or current analog input 5. Control outputs: 1 software-configurable voltage or current analog output or logic output 1 x relay logic output, 1 x "N/C" contact and 1 x "N/O" contact with common point 1 x relay logic output, 1 x "N/O" contact 6. Communication: It includes Modbus and CANopen communication protocols as standard. One RJ45 Modbus terminal port is located on the drive front panel. This is for connecting: The remote graphic display terminal A Magelis industrial HMI terminal The PowerSuite software workshop One RJ45 Modbus network port is located on the drive's control terminals. It is assigned to control and signalling by a PLC or by another type of controller. It can also be used to connect a graphic display terminal or the PowerSuite software workshop. 7. Standard functions: Energy saving ratio, 2 or 5 point quadratic ratio Automatic catching a spinning load with speed detection Adaptation of current limiting according to speed Noise and resonance suppression by means of the switching frequency, which is adjustable up to 8 khz (for 400V) during operation, by modulating the switching frequency and by the frequency jump. Preset speeds Integrated PID regulator with preset PID references and automatic/manual ("Auto/Man.") mode Electricity and service hours meter Fluid absence detection, zero flow and limited flow detection Sleep function, wake-up function Customer settings with display of physical measurements: bar, I/s, C, etc. 8. Protection functions: Motor and drive thermal protection, PTC thermal probe management Protection against overloads and overcurrents in continuous operation Machine mechanical protection via jump frequency function, output phase rotation. Protection of the installation by means of underload, overload and zero flow detection Protection via management of multiple faults and configurable alarms Schneider Electric - Altivar 61 - Technical Description for Altivar Engineered Drives Page 4 of 55

9. Options: Card with logic I/O featuring: 1 relay logic output ( NC/NO contact) 4 x 24 V DC positive or negative logic inputs 2 x 24 V DC positive or negative logic open collector outputs 1 input for PTC probes Card with extended I/O featuring: 1 differential current analog input 0...20 ma 1 software-configurable voltage (0...10 V c) or current (0...20 ma) analog input 2 software-configurable voltage (± 10 V, 0...10 V c) or current (0...20 ma) analog outputs 1 relay logic output ( NC/NO contact) 4 x 24 V DC positive or negative logic inputs 2 x 24 V DC positive or negative logic open collector outputs 1 input for PTC probes 1 frequency control input Multi-pump card which consists of: 10 logic inputs, 2 of which can be used for 2 counters 2 analog inputs 6 logic outputs 2 analog outputs A master port for the CANopen machine bus Communication cards for industrial applications: Modbus TCP Fipio Modbus/Uni-Telway: This card provides access to additional functions, which complement those of the integrated ports (Modbus ASCII and 4-wire RS 485) Modbus Plus Ethernet/IP DeviceNet PROFIBUS DP INTERBUS CC-link Communication cards for building applications (HVAC): LONWORKS METASYS N2 APOGEE FLN BACnet Circuit breaker Line contactor Motor choke Output sine filter Braking unit from 250 kw and above Mains current and mains voltage display Cable entry from above Control voltage transformer 230 V AC Power supply unit for buffer voltage 24 V DC Emergency-off / emergency-stop PTC thermistor relay Pt 100 sensor unit Air condition Cubicle plinth 200 mm Adaptor for 115 V AC logic inputs Encoder interface cards Multi-pump and Controller Inside programmable cards Power supply circuit for motor heater Power supply circuit for external fan Enclosure lighting Enclosure heater Key switch (Local/Remote) Isolating handle for switch Schneider Electric - Altivar 61 - Technical Description for Altivar Engineered Drives Page 5 of 55

10. Technical Data 400V range: 400V / 90kW Altivar 61 ATV61EXC2D90N4 frequency inverter in cubicle design IP23 (compact version) 90 kw Continuous output current: 179 A approx. 2155x600x600 mm Altivar 61 ATV61EXC5D90N4 frequency inverter in cubicle design IP54 (compact version) 90 kw Continuous output current: 179 A approx. 2260x600x600 mm Altivar 61 ATV61EXS5D90N4 frequency inverter in cubicle design IP54 (separate airflow) 90 kw Continuous output current: 179 A approx. 2355x600x600 mm Schneider Electric - Altivar 61 - Technical Description for Altivar Engineered Drives Page 6 of 55

400V / 110kW Altivar 61 ATV61EXC2C11N4 frequency inverter in cubicle design IP23 (compact version) 110 kw Continuous output current: 215 A approx. 2155x600x600 mm Altivar 61 ATV61EXC5C11N4 frequency inverter in cubicle design IP54 (compact version) 110 kw Continuous output current: 215 A approx. 2260x600x600 mm Altivar 61 ATV61EXS5C11N4 frequency inverter in cubicle design IP54 (separate airflow) 110 kw Continuous output current: 215 A approx. 2355x600x600 mm Schneider Electric - Altivar 61 - Technical Description for Altivar Engineered Drives Page 7 of 55

400V / 132kW Altivar 61 ATV61EXC2C13N4 frequency inverter in cubicle design IP23 (compact version) 132 kw Continuous output current: 259 A approx. 2155x600x600 mm Altivar 61 ATV61EXC5C13N4 frequency inverter in cubicle design IP54 (compact version) 132 kw Continuous output current: 259 A approx. 2260x600x600 mm Altivar 61 ATV61EXS5C13N4 frequency inverter in cubicle design IP54 (separate airflow) 132 kw Continuous output current: 259 A approx. 2355x600x600 mm Schneider Electric - Altivar 61 - Technical Description for Altivar Engineered Drives Page 8 of 55

400V / 160kW Altivar 61 ATV61EXC2C16N4 frequency inverter in cubicle design IP23 (compact version) 160 kw Continuous output current: 314 A approx. 2155x600x600 mm Altivar 61 ATV61EXC5C16N4 frequency inverter in cubicle design IP54 (compact version) 160 kw Continuous output current: 314 A approx. 2260x600x600 mm Altivar 61 ATV61EXS5C16N4 frequency inverter in cubicle design IP54 (separate airflow) 160 kw Continuous output current: 314 A approx. 2355x600x600 mm Schneider Electric - Altivar 61 - Technical Description for Altivar Engineered Drives Page 9 of 55

400V / 220kW Altivar 61 ATV61EXC2C22N4 frequency inverter in cubicle design IP23 (compact version) 220 kw Continuous output current: 427 A approx. 2155x600x600 mm Altivar 61 ATV61EXC5C22N4 frequency inverter in cubicle design IP54 (compact version) 220 kw Continuous output current: 427 A approx. 2260x600x600 mm Altivar 61 ATV61EXS5C22N4 frequency inverter in cubicle design IP54 (separate airflow) 220 kw Continuous output current: 427 A approx. 2355x600x600 mm Schneider Electric - Altivar 61 - Technical Description for Altivar Engineered Drives Page 10 of 55

400V / 250kW Altivar 61 ATV61EXC2C25N4 frequency inverter in cubicle design IP23 (compact version) 250 kw Continuous output current: 481 A approx. 2155x800x600 mm Altivar 61 ATV61EXC5C25N4 frequency inverter in cubicle design IP54 (compact version) 250 kw Continuous output current: 481 A approx. 2260x800x600 mm Altivar 61 ATV61EXS5C25N4 frequency inverter in cubicle design IP54 (separate airflow) 250 kw Continuous output current: 481 A approx. 2355x800x600 mm Schneider Electric - Altivar 61 - Technical Description for Altivar Engineered Drives Page 11 of 55

400V / 315kW Altivar 61 ATV61EXC2C31N4 frequency inverter in cubicle design IP23 (compact version) 315 kw Continuous output current: 616 A approx. 2155x800x600 mm Altivar 61 ATV61EXC5C31N4 frequency inverter in cubicle design IP54 (compact version) 315 kw Continuous output current: 616 A approx. 2260x800x600 mm Altivar 61 ATV61EXS5C31N4 frequency inverter in cubicle design IP54 (separate airflow) 315 kw Continuous output current: 616 A approx. 2355x800x600 mm Schneider Electric - Altivar 61 - Technical Description for Altivar Engineered Drives Page 12 of 55

400V / 400kW Altivar 61 ATV61EXC2C40N4 frequency inverter in cubicle design IP23 (compact version) 400 kw Continuous output current: 759 A approx. 2155x1000x600 mm Altivar 61 ATV61EXC5C40N4 frequency inverter in cubicle design IP54 (compact version) 400 kw Continuous output current: 759 A approx. 2260x1000x600 mm Altivar 61 ATV61EXS5C40N4 frequency inverter in cubicle design IP54 (separate airflow) 400 kw Continuous output current: 759 A approx. 2355x1400x600 mm Schneider Electric - Altivar 61 - Technical Description for Altivar Engineered Drives Page 13 of 55

400V / 500kW Altivar 61 ATV61EXC2C50N4 frequency inverter in cubicle design IP23 (compact version) 500 kw Continuous output current: 941 A approx. 2155x1000x600 mm Altivar 61 ATV61EXC5C50N4 frequency inverter in cubicle design IP54 (compact version) 500 kw Continuous output current: 941 A approx. 2260x1000x600 mm Altivar 61 ATV61EXS5C50N4 frequency inverter in cubicle design IP54 (separate airflow) 500 kw Continuous output current: 941 A approx. 2355x1400x600 mm Schneider Electric - Altivar 61 - Technical Description for Altivar Engineered Drives Page 14 of 55

400V / 630kW Altivar 61 ATV61EXC2C63N4 frequency inverter in cubicle design IP23 (compact version) 630 kw Continuous output current: 1188 A approx. 2155x1200x600 mm Altivar 61 ATV61EXC5C63N4 frequency inverter in cubicle design IP54 (compact version) 630 kw Continuous output current: 1188 A approx. 2260x1200x600 mm Altivar 61 ATV61EXS5C63N4 frequency inverter in cubicle design IP54 (separate airflow) 630 kw Continuous output current: 1188 A approx. 2355x1600x600 mm Schneider Electric - Altivar 61 - Technical Description for Altivar Engineered Drives Page 15 of 55

400V / 630kW Altivar 61 ATV61EXA2C63N4 frequency inverter in cubicle design IP23 (air cooled version) 630 kw Continuous output current: 1100 A approx. 2000x1800x600 mm Altivar 61 ATV61EXA5C63N4 frequency inverter in cubicle design IP54 (air cooled version) 630 kw Continuous output current: 1100 A approx. 2000x1800x600 mm Altivar 61 ATV61EXL5C63N4 frequency inverter in cubicle design IP55 (liquid cooled version) 630 kw Continuous output current: 1100 A approx. 2000x1800x600 mm Schneider Electric - Altivar 61 - Technical Description for Altivar Engineered Drives Page 16 of 55

400V / 710kW Altivar 61 ATV61EXA2C71N4 frequency inverter in cubicle design IP23 (air cooled version) 710 kw Continuous output current: 1230 A approx. 2000x1800x600 mm Altivar 61 ATV61EXA5C71N4 frequency inverter in cubicle design IP54 (air cooled version) 710 kw Continuous output current: 1230 A approx. 2000x1800x600 mm Altivar 61 ATV61EXL5C71N4 frequency inverter in cubicle design IP55 (liquid cooled version) 710 kw Continuous output current: 1230 A approx. 2000x1800x600 mm Schneider Electric - Altivar 61 - Technical Description for Altivar Engineered Drives Page 17 of 55

400V / 900kW Altivar 61 ATV61EXA2C90N4 frequency inverter in cubicle design IP23 (air cooled version) 900 kw Continuous output current: 1580 A Altivar 61 ATV61EXA5C90N4 frequency inverter in cubicle design IP54 (air cooled version) 900 kw Continuous output current: 1580 A Altivar 61 ATV61EXL5C90N4 frequency inverter in cubicle design IP55 (liquid cooled version) 900 kw Continuous output current: 1580 A Schneider Electric - Altivar 61 - Technical Description for Altivar Engineered Drives Page 18 of 55

400V / 1100kW Altivar 61 ATV61EXA2M11N4 frequency inverter in cubicle design IP23 (air cooled version) 1100 kw Continuous output current: 1860 A Altivar 61 ATV61EXA5M11N4 frequency inverter in cubicle design IP54 (air cooled version) 1100 kw Continuous output current: 1860 A Altivar 61 ATV61EXL5M11N4 frequency inverter in cubicle design IP55 (liquid cooled version) 1100 kw Continuous output current: 1860 A Schneider Electric - Altivar 61 - Technical Description for Altivar Engineered Drives Page 19 of 55

400V / 1300kW Altivar 61 ATV61EXA2M13N4 frequency inverter in cubicle design IP23 (air cooled version) 1300 kw Continuous output current: 2200 A Altivar 61 ATV61EXA5M13N4 frequency inverter in cubicle design IP54 (air cooled version) 1300 kw Continuous output current: 2200 A Altivar 61 ATV61EXL5M13N4 frequency inverter in cubicle design IP55 (liquid cooled version) 1300 kw Continuous output current: 2200 A Schneider Electric - Altivar 61 - Technical Description for Altivar Engineered Drives Page 20 of 55

400V / 1400kW Altivar 61 ATV61EXA2M14N4 frequency inverter in cubicle design IP23 (air cooled version) 1400 kw Continuous output current: 2430 A Altivar 61 ATV61EXA5M14N4 frequency inverter in cubicle design IP54 (air cooled version) 1400 kw Continuous output current: 2430 A Altivar 61 ATV61EXL5M14N4 frequency inverter in cubicle design IP55 (liquid cooled version) 1400 kw Continuous output current: 2430 A Schneider Electric - Altivar 61 - Technical Description for Altivar Engineered Drives Page 21 of 55

11. Technical Data 500V range: 500V / 90kW Altivar 61 ATV61EXC2D90N frequency inverter in cubicle design IP23 (compact version) 90 kw Continuous output current: 136 A approx. 2155x600x600 mm Altivar 61 ATV61EXC5D90N frequency inverter in cubicle design IP54 (compact version) 90 kw Continuous output current: 136 A approx. 2260x600x600 mm Altivar 61 ATV61EXS5D90N frequency inverter in cubicle design IP54 (separate airflow) 90 kw Continuous output current: 136 A approx. 2355x1000x600 mm Schneider Electric - Altivar 61 - Technical Description for Altivar Engineered Drives Page 22 of 55

500V / 110kW Altivar 61 ATV61EXC2C11N frequency inverter in cubicle design IP23 (compact version) 110 kw Continuous output current: 165 A approx. 2155x600x600 mm Altivar 61 ATV61EXC5C11N frequency inverter in cubicle design IP54 (compact version) 110 kw Continuous output current: 165 A approx. 2260x600x600 mm Altivar 61 ATV61EXS5C11N frequency inverter in cubicle design IP54 (separate airflow) 110 kw Continuous output current: 165 A approx. 2355x1000x600 mm Schneider Electric - Altivar 61 - Technical Description for Altivar Engineered Drives Page 23 of 55

500V / 132kW Altivar 61 ATV61EXC2C13N frequency inverter in cubicle design IP23 (compact version) 132 kw Continuous output current: 200 A approx. 2155x600x600 mm Altivar 61 ATV61EXC5C13N frequency inverter in cubicle design IP54 (compact version) 132 kw Continuous output current: 200 A approx. 2260x600x600 mm Altivar 61 ATV61EXS5C13N frequency inverter in cubicle design IP54 (separate airflow) 132 kw Continuous output current: 200 A approx. 2355x1000x600 mm Schneider Electric - Altivar 61 - Technical Description for Altivar Engineered Drives Page 24 of 55

500V / 160kW Altivar 61 ATV61EXC2C16N frequency inverter in cubicle design IP23 (compact version) 160 kw Continuous output current: 240 A approx. 2155x600x600 mm Altivar 61 ATV61EXC5C16N frequency inverter in cubicle design IP54 (compact version) 160 kw Continuous output current: 240 A approx. 2260x600x600 mm Altivar 61 ATV61EXS5C16N frequency inverter in cubicle design IP54 (separate airflow) 160 kw Continuous output current: 240 A approx. 2355x1000x600 mm Schneider Electric - Altivar 61 - Technical Description for Altivar Engineered Drives Page 25 of 55

500V / 200kW Altivar 61 ATV61EXC2C20N frequency inverter in cubicle design IP23 (compact version) 200 kw Continuous output current: 312 A approx. 2155x800x600 mm Altivar 61 ATV61EXC5C20N frequency inverter in cubicle design IP54 (compact version) 200 kw Continuous output current: 312 A approx. 2260x800x600 mm Altivar 61 ATV61EXS5C20N frequency inverter in cubicle design IP54 (separate airflow) 200 kw Continuous output current: 312 A approx. 2355x1200x600 mm Schneider Electric - Altivar 61 - Technical Description for Altivar Engineered Drives Page 26 of 55

500V / 250kW Altivar 61 ATV61EXC2C25N frequency inverter in cubicle design IP23 (compact version) 250 kw Continuous output current: 390 A approx. 2155x800x600 mm Altivar 61 ATV61EXC5C25N frequency inverter in cubicle design IP54 (compact version) 250 kw Continuous output current: 390 A approx. 2260x800x600 mm Altivar 61 ATV61EXS5C25N frequency inverter in cubicle design IP54 (separate airflow) 250 kw Continuous output current: 390 A approx. 2355x1200x600 mm Schneider Electric - Altivar 61 - Technical Description for Altivar Engineered Drives Page 27 of 55

500V / 315kW Altivar 61 ATV61EXC2C31N frequency inverter in cubicle design IP23 (compact version) 315 kw Continuous output current: 462 A approx. 2155x800x600 mm Altivar 61 ATV61EXC5C31N frequency inverter in cubicle design IP54 (compact version) 315 kw Continuous output current: 462 A approx. 2260x800x600 mm Altivar 61 ATV61EXS5C31N frequency inverter in cubicle design IP54 (separate airflow) 315 kw Continuous output current: 462 A approx. 2355x1200x600 mm Schneider Electric - Altivar 61 - Technical Description for Altivar Engineered Drives Page 28 of 55

500V / 400kW Altivar 61 ATV61EXC2C40N frequency inverter in cubicle design IP23 (compact version) 400 kw Continuous output current: 590 A approx. 2155x1200x600 mm Altivar 61 ATV61EXC5C40N frequency inverter in cubicle design IP54 (compact version) 400 kw Continuous output current: 590 A approx. 2260x1200x600 mm Altivar 61 ATV61EXS5C40N frequency inverter in cubicle design IP54 (separate airflow) 400 kw Continuous output current: 590 A approx. 2355x1600x600 mm Schneider Electric - Altivar 61 - Technical Description for Altivar Engineered Drives Page 29 of 55

500V / 500kW Altivar 61 ATV61EXC2C50N frequency inverter in cubicle design IP23 (compact version) 500 kw Continuous output current: 740 A approx. 2155x1200x600 mm Altivar 61 ATV61EXC5C50N frequency inverter in cubicle design IP54 (compact version) 500 kw Continuous output current: 740 A approx. 2260x1200x600 mm Altivar 61 ATV61EXS5C50N frequency inverter in cubicle design IP54 (separate airflow) 500 kw Continuous output current: 740 A approx. 2355x1600x600 mm Schneider Electric - Altivar 61 - Technical Description for Altivar Engineered Drives Page 30 of 55

500V / 630kW Altivar 61 ATV61EXC2C63N frequency inverter in cubicle design IP23 (compact version) 630 kw Continuous output current: 900 A approx. 2155x1200x600 mm Altivar 61 ATV61EXC5C63N frequency inverter in cubicle design IP54 (compact version) 630 kw Continuous output current: 900 A approx. 2260x1200x600 mm Altivar 61 ATV61EXS5C63N frequency inverter in cubicle design IP54 (separate airflow) 630 kw Continuous output current: 900 A approx. 2355x1600x600 mm Schneider Electric - Altivar 61 - Technical Description for Altivar Engineered Drives Page 31 of 55

500V / 630kW Altivar 61 ATV61EXA2C63N frequency inverter in cubicle design IP23 (air cooled version) 630 kw Continuous output current: 920 A approx. 2000x1800x600 mm Altivar 61 ATV61EXA5C63N frequency inverter in cubicle design IP54 (air cooled version) 630 kw Continuous output current: 920 A approx. 2000x1800x600 mm Altivar 61 ATV61EXL5C63N frequency inverter in cubicle design IP55 (liquid cooled version) 630 kw Continuous output current: 920 A approx. 2000x1800x600 mm Schneider Electric - Altivar 61 - Technical Description for Altivar Engineered Drives Page 32 of 55

500V / 800kW Altivar 61 ATV61EXA2C80N frequency inverter in cubicle design IP23 (air cooled version) 800 kw Continuous output current: 1100 A approx. 2000x1800x600 mm Altivar 61 ATV61EXA5C80N frequency inverter in cubicle design IP54 (air cooled version) 800 kw Continuous output current: 1100 A approx. 2000x1800x600 mm Altivar 61 ATV61EXL5C80N frequency inverter in cubicle design IP55 (liquid cooled version) 800 kw Continuous output current: 1100 A approx. 2000x1800x600 mm Schneider Electric - Altivar 61 - Technical Description for Altivar Engineered Drives Page 33 of 55

500V / 900kW Altivar 61 ATV61EXA2C90N frequency inverter in cubicle design IP23 (air cooled version) 900 kw Continuous output current: 1230 A approx. 2000x1800x600 mm Altivar 61 ATV61EXA5C90N frequency inverter in cubicle design IP54 (air cooled version) 900 kw Continuous output current: 1230 A approx. 2000x1800x600 mm Altivar 61 ATV61EXL5C90N frequency inverter in cubicle design IP55 (liquid cooled version) 900 kw Continuous output current: 1230 A approx. 2000x1800x600 mm Schneider Electric - Altivar 61 - Technical Description for Altivar Engineered Drives Page 34 of 55

500V / 1100kW Altivar 61 ATV61EXA2M11N frequency inverter in cubicle design IP23 (air cooled version) 1100 kw Continuous output current: 1580 A Altivar 61 ATV61EXA5M11N frequency inverter in cubicle design IP54 (air cooled version) 1100 kw Continuous output current: 1580 A Altivar 61 ATV61EXL5M11N frequency inverter in cubicle design IP55 (liquid cooled version) 1100 kw Continuous output current: 1580 A Schneider Electric - Altivar 61 - Technical Description for Altivar Engineered Drives Page 35 of 55

500V / 1300kW Altivar 61 ATV61EXA2M13N frequency inverter in cubicle design IP23 (air cooled version) 1300 kw Continuous output current: 1860 A Altivar 61 ATV61EXA5M13N frequency inverter in cubicle design IP54 (air cooled version) 1300 kw Continuous output current: 1860 A Altivar 61 ATV61EXL5M13N frequency inverter in cubicle design IP55 (liquid cooled version) 1300 kw Continuous output current: 1860 A Schneider Electric - Altivar 61 - Technical Description for Altivar Engineered Drives Page 36 of 55

500V / 1500kW Altivar 61 ATV61EXA2M15N frequency inverter in cubicle design IP23 (air cooled version) 1500 kw Continuous output current: 2140 A Altivar 61 ATV61EXA5M15N frequency inverter in cubicle design IP54 (air cooled version) 1500 kw Continuous output current: 2140 A Altivar 61 ATV61EXL5M15N frequency inverter in cubicle design IP55 (liquid cooled version) 1500 kw Continuous output current: 2140 A Schneider Electric - Altivar 61 - Technical Description for Altivar Engineered Drives Page 37 of 55

500V / 1800kW Altivar 61 ATV61EXA2M18N frequency inverter in cubicle design IP23 (air cooled version) 1800 kw Continuous output current: 2430 A Altivar 61 ATV61EXA5M18N frequency inverter in cubicle design IP54 (air cooled version) 1800 kw Continuous output current: 2430 A Altivar 61 ATV61EXL5M18N frequency inverter in cubicle design IP55 (liquid cooled version) 1800 kw Continuous output current: 2430 A Schneider Electric - Altivar 61 - Technical Description for Altivar Engineered Drives Page 38 of 55

12. Technical Data 690V range: 690V / 110kW Altivar 61 ATV61EXC2C11Y frequency inverter in cubicle design IP23 (compact version) 110 kw Continuous output current: 125 A approx. 2155x600x600 mm Altivar 61 ATV61EXC5C11Y frequency inverter in cubicle design IP54 (compact version) 110 kw Continuous output current: 125 A approx. 2260x600x600 mm Altivar 61 ATV61EXS5C11Y frequency inverter in cubicle design IP54 (separate airflow) 110 kw Continuous output current: 125 A approx. 2355x1000x600 mm Schneider Electric - Altivar 61 - Technical Description for Altivar Engineered Drives Page 39 of 55

690V / 132kW Altivar 61 ATV61EXC2C13Y frequency inverter in cubicle design IP23 (compact version) 132 kw Continuous output current: 150 A approx. 2155x600x600 mm Altivar 61 ATV61EXC5C13Y frequency inverter in cubicle design IP54 (compact version) 132 kw Continuous output current: 150 A approx. 2260x600x600 mm Altivar 61 ATV61EXS5C13Y frequency inverter in cubicle design IP54 (separate airflow) 132 kw Continuous output current: 150 A approx. 2355x1000x600 mm Schneider Electric - Altivar 61 - Technical Description for Altivar Engineered Drives Page 40 of 55

690V / 160kW Altivar 61 ATV61EXC2C16Y frequency inverter in cubicle design IP23 (compact version) 160 kw Continuous output current: 180 A approx. 2155x600x600 mm Altivar 61 ATV61EXC5C16Y frequency inverter in cubicle design IP54 (compact version) 160 kw Continuous output current: 180 A approx. 2260x600x600 mm Altivar 61 ATV61EXS5C16Y frequency inverter in cubicle design IP54 (separate airflow) 160 kw Continuous output current: 180 A approx. 2355x1000x600 mm Schneider Electric - Altivar 61 - Technical Description for Altivar Engineered Drives Page 41 of 55

690V / 200kW Altivar 61 ATV61EXC2C20Y frequency inverter in cubicle design IP23 (compact version) 200 kw Continuous output current: 220 A approx. 2155x600x600 mm Altivar 61 ATV61EXC5C20Y frequency inverter in cubicle design IP54 (compact version) 200 kw Continuous output current: 220 A approx. 2260x600x600 mm Altivar 61 ATV61EXS5C20Y frequency inverter in cubicle design IP54 (separate airflow) 200 kw Continuous output current: 220 A approx. 2355x1000x600 mm Schneider Electric - Altivar 61 - Technical Description for Altivar Engineered Drives Page 42 of 55

690V / 250kW Altivar 61 ATV61EXC2C25Y frequency inverter in cubicle design IP23 (compact version) 250 kw Continuous output current: 290 A approx. 2155x800x600 mm Altivar 61 ATV61EXC5C25Y frequency inverter in cubicle design IP54 (compact version) 250 kw Continuous output current: 290 A approx. 2260x800x600 mm Altivar 61 ATV61EXS5C25Y frequency inverter in cubicle design IP54 (separate airflow) 250 kw Continuous output current: 290 A approx. 2355x1200x600 mm Schneider Electric - Altivar 61 - Technical Description for Altivar Engineered Drives Page 43 of 55

690V / 315kW Altivar 61 ATV61EXC2C31Y frequency inverter in cubicle design IP23 (compact version) 315 kw Continuous output current: 355 A approx. 2155x800x600 mm Altivar 61 ATV61EXC5C31Y frequency inverter in cubicle design IP54 (compact version) 315 kw Continuous output current: 355 A approx. 2260x800x600 mm Altivar 61 ATV61EXS5C31Y frequency inverter in cubicle design IP54 (separate airflow) 315 kw Continuous output current: 355 A approx. 2355x1200x600 mm Schneider Electric - Altivar 61 - Technical Description for Altivar Engineered Drives Page 44 of 55

690V / 400kW Altivar 61 ATV61EXC2C40Y frequency inverter in cubicle design IP23 (compact version) 400 kw Continuous output current: 420 A approx. 2155x800x600 mm Altivar 61 ATV61EXC5C40Y frequency inverter in cubicle design IP54 (compact version) 400 kw Continuous output current: 420 A approx. 2260x800x600 mm Altivar 61 ATV61EXS5C40Y frequency inverter in cubicle design IP54 (separate airflow) 400 kw Continuous output current: 420 A approx. 2355x1200x600 mm Schneider Electric - Altivar 61 - Technical Description for Altivar Engineered Drives Page 45 of 55

690V / 500kW Altivar 61 ATV61EXC2C50Y frequency inverter in cubicle design IP23 (compact version) 500 kw Continuous output current: 543 A approx. 2155x1200x600 mm Altivar 61 ATV61EXC5C50Y frequency inverter in cubicle design IP54 (compact version) 500 kw Continuous output current: 543 A approx. 2260x1200x600 mm Altivar 61 ATV61EXS5C50Y frequency inverter in cubicle design IP54 (separate airflow) 500 kw Continuous output current: 543 A approx. 2355x1600x600 mm Schneider Electric - Altivar 61 - Technical Description for Altivar Engineered Drives Page 46 of 55

690V / 630kW Altivar 61 ATV61EXC2C63Y frequency inverter in cubicle design IP23 (compact version) 630 kw Continuous output current: 675 A approx. 2155x1200x600 mm Altivar 61 ATV61EXC5C63Y frequency inverter in cubicle design IP54 (compact version) 630 kw Continuous output current: 675 A approx. 2260x1200x600 mm Altivar 61 ATV61EXS5C63Y frequency inverter in cubicle design IP54 (separate airflow) 630 kw Continuous output current: 675 A approx. 2355x1600x600 mm Schneider Electric - Altivar 61 - Technical Description for Altivar Engineered Drives Page 47 of 55

690V / 800kW Altivar 61 ATV61EXC2C80Y frequency inverter in cubicle design IP23 (compact version) 800 kw Continuous output current: 840 A approx. 2155x1200x600 mm Altivar 61 ATV61EXC5C80Y frequency inverter in cubicle design IP54 (compact version) 800 kw Continuous output current: 840 A approx. 2260x1200x600 mm Altivar 61 ATV61EXS5C80Y frequency inverter in cubicle design IP54 (separate airflow) 800 kw Continuous output current: 840 A approx. 2355x1600x600 mm Schneider Electric - Altivar 61 - Technical Description for Altivar Engineered Drives Page 48 of 55

690V / 800kW Altivar 61 ATV61EXA2C80Y frequency inverter in cubicle design IP23 (air cooled version) 800 kw Continuous output current: 840 A approx. 2000x1800x600 mm Altivar 61 ATV61EXA5C80Y frequency inverter in cubicle design IP54 (air cooled version) 800 kw Continuous output current: 840 A approx. 2000x1800x600 mm Altivar 61 ATV61EXL5C80Y frequency inverter in cubicle design IP55 (liquid cooled version) 800 kw Continuous output current: 840 A approx. 2000x1800x600 mm Schneider Electric - Altivar 61 - Technical Description for Altivar Engineered Drives Page 49 of 55

690V / 1000kW Altivar 61 ATV61EXA2M10Y frequency inverter in cubicle design IP23 (air cooled version) 1000 kw Continuous output current: 1050 A approx. 2000x1800x600 mm Altivar 61 ATV61EXA5M10Y frequency inverter in cubicle design IP54 (air cooled version) 1000 kw Continuous output current: 1050 A approx. 2000x1800x600 mm Altivar 61 ATV61EXL5M10Y frequency inverter in cubicle design IP55 (liquid cooled version) 1000 kw Continuous output current: 1050 A approx. 2000x1800x600 mm Schneider Electric - Altivar 61 - Technical Description for Altivar Engineered Drives Page 50 of 55

690V / 1200kW Altivar 61 ATV61EXA2M12Y frequency inverter in cubicle design IP23 (air cooled version) 1200 kw Continuous output current: 1230 A approx. 2000x1800x600 mm Altivar 61 ATV61EXA5M12Y frequency inverter in cubicle design IP54 (air cooled version) 1200 kw Continuous output current: 1230 A approx. 2000x1800x600 mm Altivar 61 ATV61EXL5M12Y frequency inverter in cubicle design IP55 (liquid cooled version) 1200 kw Continuous output current: 1230 A approx. 2000x1800x600 mm Schneider Electric - Altivar 61 - Technical Description for Altivar Engineered Drives Page 51 of 55

690V / 1500kW Altivar 61 ATV61EXA2M15Y frequency inverter in cubicle design IP23 (air cooled version) 1500 kw Continuous output current: 1580 A Altivar 61 ATV61EXA5M15Y frequency inverter in cubicle design IP54 (air cooled version) 1500 kw Continuous output current: 1580 A Altivar 61 ATV61EXL5M15Y frequency inverter in cubicle design IP55 (liquid cooled version) 1500 kw Continuous output current: 1580 A Schneider Electric - Altivar 61 - Technical Description for Altivar Engineered Drives Page 52 of 55

690V / 1800kW Altivar 61 ATV61EXA2M18Y frequency inverter in cubicle design IP23 (air cooled version) 1800 kw Continuous output current: 1860 A Altivar 61 ATV61EXA5M18Y frequency inverter in cubicle design IP54 (air cooled version) 1800 kw Continuous output current: 1860 A Altivar 61 ATV61EXL5M18Y frequency inverter in cubicle design IP55 (liquid cooled version) 1800 kw Continuous output current: 1860 A Schneider Electric - Altivar 61 - Technical Description for Altivar Engineered Drives Page 53 of 55

690V / 2100kW Altivar 61 ATV61EXA2M21Y frequency inverter in cubicle design IP23 (air cooled version) 2100 kw Continuous output current: 2140 A Altivar 61 ATV61EXA5M21Y frequency inverter in cubicle design IP54 (air cooled version) 2100 kw Continuous output current: 2140 A Altivar 61 ATV61EXL5M21Y frequency inverter in cubicle design IP55 (liquid cooled version) 2100 kw Continuous output current: 2140 A Schneider Electric - Altivar 61 - Technical Description for Altivar Engineered Drives Page 54 of 55

690V / 2400kW Altivar 61 ATV61EXA2M24Y frequency inverter in cubicle design IP23 (air cooled version) 2400 kw Continuous output current: 2430 A Altivar 61 ATV61EXA5M24Y frequency inverter in cubicle design IP54 (air cooled version) 2400 kw Continuous output current: 2430 A Altivar 61 ATV61EXL5M24Y frequency inverter in cubicle design IP55 (liquid cooled version) 2400 kw Continuous output current: 2430 A Schneider Electric - Altivar 61 - Technical Description for Altivar Engineered Drives Page 55 of 55