Directional Seat Valve WSE 3

Similar documents
2/2 and 3/2 Way Size 6 Seat Valves

3/2- and 2/2-way cartridge valve type BVE

Directional seated valves type VP 1

Fluid. Flu. Fluid Fluid. uid Power d Power P. Fluid Power P. Fluid Power. Fluid Power Power. d Power. Directional Cetop Valves DCV 03.

3/2 Solenoid Cartridge Valve, Size 6

SOLENOID VALVES 3-4 WAY

RPE3-04. Functional Description HA /2010. Directional Control Valves Solenoid Operated. Replaces HA /2007

E4E PILOT OPERATED DIRECTIONAL CONTROL VALVE WITH ELECTRIC PROPORTIONAL CONTROL SERIES 51

Chapter 6: Check Valves

Safety for Hydraulics Leak free double check valve, pilot operated, series DERV Cartridge type, two stage

Assisted lift operated 2/2-way solenoid valves Type EV250B

3/2-way Solenoid Valve, direct-acting, NC or NO

Cartridge Valves. Solenoid Valves. Vickers. Screw-in Cartridge Valves. Maximum Pressure 210 bar (3000 psi) Maximum Flow 227 l/min (60 USgpm)

SOLENOID VALVES AND PNEUMATIC VALVES

System 8. ü ( System 8

Pressure relief valves Size 6

Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv)

Unit 24: Applications of Pneumatics and Hydraulics

Fluid Level Gauge Fluid Level Sensor Temperature Switch FSA / FSK / TS

Check Valves. Pilot Operated Check Valves. Vickers. PCGV-6/8, 10 Series; PCG5V-6/8, 20 Series. Typical Section. Features and Benefits

D634-P Series Direct Drive Proportional Valve with Integrated 24 V Electronics ISO 4401 Size 05

Electro-hydraulic pressure switches type DG

type V46, solenoid or pneumatic operated

Electro-pneumatic control valves

3-Way heavy duty flow control, with pressure compensated and solenoid controlled priority flow

4/2-Way Pneumatic Solenoid Valve

Solenoid valves 2/2-way direct-operated Type EV210A

Safety for Hydraulics Leak free check valve, pilot operated, series ERV Cartridge type, two stage

Single sub-base valve

3/2-way pneumatic cartridge solenoid valve

3 Port Solenoid Valve

Chapter 5: Flow Valves

Flow Control Valve. 1 Descriptions. 2 Symbols. Series SRCB Generals. 1.2 Application examples way flow control way flow control

Cable Plug acc. to DIN EN , Form A

2-Way heavy duty flow control, with pressure compensated, solenoid and load sensing controlled priority flow

Load-sensing control block in mono and sandwich plate design

1. General. D 7490/1 2/2-way cartridge valve EM 2.2. Operation pressure p max Flow Q max. = 450 bar = 160 lpm. Cartridge valve (see section 2)

2 WAY (2/2) AND 3 WAY (3/2) BRASS AND STAINLESS STEEL SOLENOID VALVES

Electric Rotary Actuator - On/Off or programmable control actuator

3 WAY (3/2) POPPET VALVES FOR AIR AND VACUUM SERVICE SOLENOID OR AIR ACTUATED BROCHURE N-223

97300 NAMUR series, 3/2 & 5/2 Indirect solenoid actuated spool valve

Solenoid valves Type EVU

Steering unit. Table of contents. Features RE 11872/ Type LAGL. Frame sizes 500 to 1000 Component series 1X Maximum flow 80 l/min

Seat Valves. 1 Description. Series SVH Technical data. 1.2 Performance graphs

D660 Series Servo-Proportional Control Valves with Integrated Electronics ISO 4401 Size 05 to 10

UM/ /2 or 5/3 Solenoid and air pilot actuated soft spool valves

Proportional pressure regulators VPPE

Electrically operated valves Series M-05, 3/2-, 5/2- and 5/3-way G1/8 650 and 750 Nl/min (0.661 and Cv)

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics

UM/ /2 & 5/3 valves, solenoid and pilot actuated ISO , ISO size 1, 2, 3 & 4 Sub-base mounted

OUT. The SF2 series suction filter are designed for reservoir side-wall applications. This completely new design of filter allows the filter

Line rupture protection valves type LB

Pressure Relief. Pressure Relief and Sequence Valves CG2V-6/8, 10 Series; CG5V-6/8, 20 Series. Vickers. Features and Benefits.

3/2-way Mini Solenoid Valve

Directional seated valves Directly actuated, leakagefree for hydraulic systems For the assembly on connection sub-plates

M A N U A L

Position Transducers with Restoring Spring 10, 25, 50, 75, 100 mm TR, TRS Series

SCP ISO. Other advantages: SCP ISO is a series of piston pumps with a fixed displacement for mobile and stationary hydraulics.

3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve

SITEMA PowerStroke. Technical Information TI-P11. 1 Function. 2 Applications. Mould Closing Devices series FSK. Contents

Sensors. Sensors. All Cylinders. Specifications. Features: Features Type REED HALL EFFECT NPN or PNP. Ø8mm - 125mm

Check Valves Valve locator

Sporlan V-Series Ruby Seat Solenoid Valves

Series description: Wilo-Drain TC 40

G1/4 Q8. Standard with biased position

Actuators and Sensors. Products

*Rated to 207 Bar/3000 PSI with Aluminum Body. Denotes New Winner s Circle Product Line. Catalog HY /US

MANTA Piston Distributor for Oil and Fluid Grease

Flow divider (flow distributor), type TQ

The SF2 series are designed for reservoir side-wall mounting applications, suitable for flow rates to 850 l/min and filtration from 25 to 250 micron.

3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve

2.12. page Products for Explosion hazardous Environment

DXPE*J /215 ED. DIRECtIONAL CONtROL VALVE PILOt OPERAtED, WItH OBE AND FEEDBACK. Q max (see performance table) SERIES 30

Pressure reducing valve, direct operated, Type ZDR 6 D

Pressure Relief Valves SPV, SPVF

Radial piston pumps type R and RG

4 Posiflow Proportional Solenoid Valves

Proportional relief valves type AGMZO-TERS, AERS two stage, with integral or remote pressure transducer, ISO 6264 size 10, 20 and 32

Hydraulic Control Solutions

Ball valve C 16 valve ball completely moulded in place, extremely low clearance volume, high k v value

4/4-way servo solenoid directional control valves, directly operated, with electrical position feedback and on-board electronics (OBE)

Direct Operated Regulator for 6.0 MPa (Relieving Type) How to Order. Body size 30 40

RA / Functional description 1/10. 4/3-, 4/2- and 3/2 Directional Control Valves Model WE 6.. /E, Series 6X with wet pin AC or DC solenoids

ISO /2 (VDMA 24563) ISO 02 (18 mm) - ISO 01 (26 mm) Valves

Industrial Valves. Marketing Catalog. Reliable and continuous performance in the world's most demanding and rigorous applications.

How To Use A Flowmeter

VARIABLE DISPLACEMENT AXIAL PISTON PUMPS. For truck applications

DSE5J /112 ED DIRECTIONAL VALVE WITH PROPORTIONAL CONTROL FEEDBACK AND INTEGRATED ELECTRONICS SERIES 10 SUBPLATE MOUNTING ISO (CETOP 05)

Rotary Actuators, NAMUR interface VDI/VDE 3845 & ISO 5211 (ATEX certified) Series ARP

820 NOVA mv THERMOPILE POWER SUPPLY THERMOELECTRIC SAFETY DEVICE SERVO-CONTROLLED PRESSURE REGULATOR SHUT-OFF SOLENOID VALVE.

3753 en /b VE/B - VE/RG Va V riable speed drives

Solenoid Operated Directional Valves

Digital inductive conductivity transmitter

Solenoid Operated Directional Valves

VP23, 3-way proportional pressure control valves Seat valve with μp-driven pressure control

Inrush Apparent power (VA) Flow Characteristics/Weight. Port size Rc. Valve model VS VS VS VS VS

size size

5 Port Pilot Operated Solenoid Valve Rubber Seal. Specifications Fluid Operating pressure range. 2 position single/3 position 2 position double

SQUARE D INDUSTRIAL CONTROL PRODUCTS

DEK-REL- 24/1/SEN. Extract from the online catalog. Order No.:

Transcription:

Directional Seat Valve WSE 3 Up to 500 bar Up to 12 l/min Type WSE 3 E cartridge valve 382

1. DESCRIPTION 1.1. GENERAL According to DIN -ISO 1219 HYDAC WSE 3 directional seat valves are directional valves which open and close one or more flow paths. The opening and closing functions are performed by solenoid operated control elements. These valves are all size 3. 1.2. MODE OF OPERATION HYDAC WSE 3 directional seat valves are ball seat type valves. The control elements are hardened and polished. This means: In the closed position the flow paths are leakage -free and pressure tight. This enables reliable positioning of cylinders and maintenance of pressure over long periods. The valves have a high level of switching safety even after long periods of non -actuation at high pressure. The actuating solenoids of these direct -operated valves are of the wet -pin type. This type of construction has the following advantages: Fully enclosed design Low noise level and long life due to oil -dampened armature impact Good heat dissipation via the oil Solenoid coils can be rotated through 360 and are removable Solenoid coils can be changed and coils of different voltages can be fitted without interruption to the hydraulic system. The solenoids are principally designed for DC operation. For operation with AC supply, the required DC supply is produced by means of bridge rectifier connectors (type W). All seals coming into contact with the operating fluid are in Viton or PTFE as standard. 1.3. TYPE OF CONNECTION HYDAC WSE 3 E directional seat valves are cartridge type valves for mounting onto manifold blocks, housings, cylinders etc. Housings for inline mounting and manifold mounting are available (see brochure Connection Housings for Cartridge Valves no. E 5.252../..). 2. TECHNICAL SPECIFICATIONS 2.1. GENERAL 2.1.1. Designation and symbol 3/2 directional seat valves Symbol C 3/2 directional seat valve, P is closed and leakage free, A to T is open (switching position a). When the solenoid is actuated, P to A is opened and port T is closed and leakage free (switching position b). Flow is only permissible in direction of arrow. Item 1 solenoid coil Item 2 solenoid armature Item 3 solenoid valve housing Item 4 pressure compensating piston Item 5 pressure compensating bore Item 6 closing element Item 7 spring Item 8 plug Item 9 emergency manual override 383

Symbol D 2.1.2. Model code for directional seat valves (also ordering example) WS E 3 E 0 C. X / G 24 -Z5L -N Directional seat valve Type of operation E = solenoid operated A B C D 3/2 directional seat valve; P to A normally open, T closed and leakage free (switching position a). When the solenoid is actuated, port P is closed and leakage free and A to T is open (switching position b). Flow is only permissible in direction of arrow. Dispositif deréglage Ressort Corps Elément obturateur Size Type of connection E = cartridge Additional functions 0 = technical specifications as per this brochure Symbol (see point 2.1.1.) C = 3/2 directional seat valve, P to A normally closed D = 3/2 directional seat valve, P to A normally open Series (determined by manufacturer) Type of voltage for solenoid (see point 2.3.4.) G = DC W = AC, rectifier plug required AC models are not dependent on frequency Nominal voltage for solenoid (see point 2.3.3.) 24 = 24 V DC (standard) 230 = 230 V 50/60 Hz AC (standard) Electrical connection for actuating solenoid no details = DIN 43650 plug without connector Z4 = connector DIN 43650 -AF2 -Pg11 Z5 = large connector Z5L = large connector with light for AC type, connector is automatically supplied with bridge rectifier insert Emergency manual operation (see point 4) no details = no emergency manual operation N = pin type operation NG = thumb pressure operation Standard models Model Code Symbol Stock no. (= order code) Item 1 solenoid coil Item 2 solenoid armature Item 3 solenoid valve housing Item 4 pressure compensating piston Item 5 pressure compensating bore Item 6 closing element Item 7 spring Item 8 plug Item 9 emergency manual override WSE 3 E 0 C.X / G24 -Z4 -N WSE 3 E 0 C.X / W230 -Z4 -N WSE 3 E 0 D.X / G24 -Z4 -N WSE 3 E 0 D.X / W230 -Z4 -N 710 462 710 463 710 464 710 465 384

2.1.3. Type of construction Ball seat valve, direct operated 2.1.4. Type of connection Cartridge valve 2.1.5. Weight WSE 3 E = 0.43 kg 2.1.6. Mounting position Optional, but preferably the solenoid should be fitted pointing upwards to horizontal 2.1.7. Flow direction According to symbol, permissible only in direction of arrow 2.1.8. Materials Valve seats, closing elements and actuating elements: hardened steel 2.1.9. Ambient temperature range Min. - 20 C Max. + 40 C 2.2. HYDRAULIC DETAILS 2.2.1. Operating pressure Nominal pressure P N =500 bar across all ports Pressure across P A T 2.2.2. Pressure fluid Hydraulic fluid to DIN 51524 Parts 1 and 2. For other media, please consult our Sales/Technical Department 2.2.3. Temperature range of fluid Min. - 20 C Max. + 80 C 2.2.4. Viscosity range Min. 10 mm 2 /s Max. 380 mm 2 /s 2.2.5. Flow rate Q max = 12 l/min dependent on pressure Performance graph 2.2.6. Filtration Max. permissible contamination level of operating fluid - at operating pressure up to 350 bar NAS 1638, class 10. We recommend a retention rate of ß 20 100. - at operating pressure up to 500 bar NAS 1638, class 9. We recommend a filter with a minimum retention rate of ß 10 100. The installation filters and regular replacement of elements guarantees correct performance, reduces wear and tear and increases the service life. 2.2.7. Switching overlap Negative; during switching all ports are momentarily interconnected. 2.2.8. Δp -Q Curves Measured at ν = 34 mm 2 /s WSE 3 E Symbol Flow direction Curve C D P A A T P A A T a a b b 2.3. ELECTRICAL DETAILS 2.3.1. Type of operation Solenoid operated by means of pressure -tight, wet -pin single stroke solenoids to VDE 0580. 2.3.2. Switching time (at nominal voltage) Depending on pressure across individual ports and flow rate, switch -on time is approximately 40 ms, switch -off time approximately 45 ms. 2.3.3. Nominal voltage U N Voltages available: Voltage type G: 24 V Voltage type W: 230 V Other voltages in the range 6 to 240 V are available on request. 2.3.4. Type of voltage DC solenoid (code G). For use with AC, the required DC is produced by using a bridge rectifier connector (code W). 2.3.5. Voltage tolerance + 10 % - 5 % 2.3.6. Power consumption P 20 = 26 W 2.3.7. Switch -on time 100% switch -on time = continuous operation. Minimum dimensions for housing of WSE 3 E cartridge valve: 50 x 50 x 30 mm. 2.3.8. Safety type IP 65 to DIN 40050 provided connector is fitted correctly. 2.3.9. Switching frequency 3600 per hour maximum Symbol Curve C...................... 1 D...................... 2 The maximum permissible flow rate must not be exceeded. If necessary, an orifice must be fitted to protect the valve. 385

3. DIMENSIONS WSE 3 4. EMERGENCY MANUAL OPERATION no details = no emergency manual operation connector can be displaced by 4 x 90_ torque Mechanical operation is not possible N = pin type operation after loosening knurled nut, coil can be rotated though 360_ and removed Mechanical override by means of pin. The opening is 5 mm in diameter. The pin is countersunk by 3.5 mm. The operating stroke is 1.5 mm. NG = thumb pressure operation (rubber cap) Installations dimensions for WSE 3 Mechanical operation without tool is possible (thumb pressure) Operating force graph force [dan] pressure (bar) pocket depth pocket depth 5. NOTE The information in this brochure relates to the operating conditions and applications described. For applications or operating conditions not described, please contact the relevant technical department. Subject to technical modifications. 386

NOTE The information in this brochure relates to the operating conditions and applications described. For applications or operating conditions not described, please contact the relevant technical department. Subject to technical modifications. HYDAC Fluidtechnik GmbH Justus-von-Liebig-Str. D-66280 Sulzbach/Saar Tel: 0 68 97 /509-01 Fax: 0 68 97 /509-598 E-Mail: flutec@hydac.com 387