FMC Environmental Solutions Peroxygen Talk March 2009 Oxidation Reduction Potentials (ORP)

Similar documents
Ch 20 Electrochemistry: the study of the relationships between electricity and chemical reactions.

MULTIPLE CHOICE. Choose the one alternative that best completes the statement or answers the question.

Chapter 13: Electrochemistry. Electrochemistry. The study of the interchange of chemical and electrical energy.

Discovering Electrochemical Cells

K + Cl - Metal M. Zinc 1.0 M M(NO

Galvanic cell and Nernst equation

CHM1 Review Exam 12. Topics REDOX

Name Electrochemical Cells Practice Exam Date:

1332 CHAPTER 18 Sample Questions

This value, called the ionic product of water, Kw, is related to the equilibrium constant of water

Chem 1721 Brief Notes: Chapter 19

A Potentiometric Analysis of Fluoride Ion in Toothpaste

EXPERIMENT 7 Electrochemical Cells: A Discovery Exercise 1. Introduction. Discussion

2. Write the chemical formula(s) of the product(s) and balance the following spontaneous reactions.

Experiment 9 Electrochemistry I Galvanic Cell

Figure 1. A voltaic cell Cu,Cu 2+ Ag +, Ag. gas is, by convention, assigned a reduction potential of 0.00 V.

Chemistry 122 Mines, Spring 2014

Review: Balancing Redox Reactions. Review: Balancing Redox Reactions

Electrochemistry Worksheet

Summer 2003 CHEMISTRY 115 EXAM 3(A)

The Control of ph and Oxidation Reduction Potential (ORP) in Cooling Tower Applications By Charles T. Johnson, Walchem Corporation

CHAPTER 21 ELECTROCHEMISTRY

Determining Equivalent Weight by Copper Electrolysis

Electrochemistry Voltaic Cells

Building Electrochemical Cells

AP Chemistry CHAPTER 20- Electrochemistry 20.1 Oxidation States

Electrochemistry - ANSWERS

Corrosion of Copper in Water

Instructions Answer all questions in the spaces provided. Do all rough work in this book. Cross through any work you do not want to be marked.

Preliminary Concepts. Preliminary Concepts. Class 8.3 Oxidation/Reduction Reactions and Electrochemistry I. Friday, October 15 Chem 462 T.

ELECTROCHEMICAL CELLS

Sodium and Potassium chlorate synthesis, the complete guide

Galvanic Cells. SCH4U7 Ms. Lorenowicz. Tuesday, December 6, 2011

Biogeochemistry of Wetlands

ph Measurement and Control

EXPERIMENT #9 CORROSION OF METALS

Name AP CHEM / / Collected Essays Chapter 17 Answers

Chapter 12: Oxidation and Reduction.

CELL POTENTIAL, E. Terms Used for Galvanic Cells. Uses of E o Values CELL POTENTIAL, E. Galvanic Cell. Organize halfreactions

Redox and Electrochemistry

AP* Chemistry ELECTROCHEMISTRY

The Electrical Control of Chemical Reactions E3-1

5.111 Principles of Chemical Science

4. Using the data from Handout 5, what is the standard enthalpy of formation of BaO (s)? What does this mean?

Chapter 20. MULTIPLE CHOICE. Choose the one alternative that best completes the statement or answers the question.

ELECTROCHEMICAL CELLS LAB

Galvanic Cells and the Nernst Equation

Useful charge on one mole of electrons: 9.64 x 10 4 coulombs/mol e - = F F is the Faraday constant

LEAD-ACID STORAGE CELL

Electrochemistry. Chapter 18 Electrochemistry and Its Applications. Redox Reactions. Redox Reactions. Redox Reactions

reduction ore = metal oxides metal oxidation

Chemistry 119: Experiment 7. Potentiometric Titration of Ascorbic Acid in Vitamin C Tablets

Chemical Reactions in Water Ron Robertson

5.111 Principles of Chemical Science

PROCEDURE: Part A. Activity Series and Simple Galvanic Cells

REACTIONS OF SOME TRANSITION METAL IONS

Chapter 8: Chemical Equations and Reactions

CHAPTER 13: Electrochemistry and Cell Voltage

white paper reviews why the chlor-alkali process is so damaging to ph electrodes and discusses a sensor design that has

Microbiological and Geochemical Dynamics of the Subsurface: chemical oxidation and bioremediation of organic contaminants. Nora Barbour Sutton

Correlation of Nelson Chemistry Alberta to the Alberta Chemistry Curriculum

THE ELECTROCHEMISTRY OF CORROSION Edited by Gareth Hinds from the original work of J G N Thomas

Electrochemistry. Pre-Lab Assignment. Purpose. Background. Experiment 12

How Sensors Work. How Oxygen, Electrochemical Toxic, and Metal Oxide Semiconductor Sensors Work *

Chapter 17. How are acids different from bases? Acid Physical properties. Base. Explaining the difference in properties of acids and bases

Chem101: General Chemistry Lecture 9 Acids and Bases

o Electrons are written in half reactions but not in net ionic equations. Why? Well, let s see.

EDEXCEL INTERNATIONAL GCSE CHEMISTRY EDEXCEL CERTIFICATE IN CHEMISTRY ANSWERS SECTION C

12. REDOX EQUILIBRIA

HOW TO MAKE STANDARD SOLUTIONS FOR CHEMISTRY

Dissimilar Metal Corrosion

Practical Lesson No 4 TITRATIONS

Chapter 8 - Chemical Equations and Reactions

ACID-BASE TITRATIONS: DETERMINATION OF CARBONATE BY TITRATION WITH HYDROCHLORIC ACID BACKGROUND

Writing and Balancing Chemical Equations

6 Reactions in Aqueous Solutions

Chapter 11. Electrochemistry Oxidation and Reduction Reactions. Oxidation-Reduction Reactions. Oxidation-Reduction Reactions

NET IONIC EQUATIONS. A balanced chemical equation can describe all chemical reactions, an example of such an equation is:

Question Bank Electrolysis

Chemistry 151 Final Exam

Measurement by Ion Selective Electrodes

Lewis Dot Structures of Atoms and Ions

This experiment involves the separation and identification of ions using

OXIDATION-REDUCTION TITRATIONS-Permanganometry

Neutralizing an Acid and a Base

Electrochemistry Revised 04/29/15

UNIT 2 PRACTICE EXAM (Part 1: General Chemistry)

Introduction to electrolysis - electrolytes and non-electrolytes

Chapter 7: Chemical Reactions

Formulae, stoichiometry and the mole concept

Petri Dish Electrolysis Electrolysis Reactions

Standardization of Potassium Permanganate solution with Standard Sodium Oxalate Solution.

REACTIONS OF SOME TRANSITION METAL IONS COBALT

Chapter 1. Introduction of Electrochemical Concepts

Balancing Reaction Equations Oxidation State Reduction-oxidation Reactions

Practical Examples of Galvanic Cells

Stoichiometry Review

Electrochemical Half Cells and Reactions

PN /rev. D December Theory and Practice of ph Measurement

ELECTROCHEMISTRY. Theory and Practice

Transcription:

FMC Environmental Solutions Peroxygen Talk March 2009 Oxidation Reduction Potentials (ORP) In this month s Peroxygen Talk, Frank Sessa, of FMC s Environmental Solutions team, discusses measurement of the Oxidation-Reduction Potential (ORP). Mr. Sessa earned a BS in chemistry and physics from the South Connecticut State University and a master s in electrochemistry from the University of Connecticut. Mr. Sessa has been with FMC for the past ten years and provides expertise in chemical oxidation and aerobic bioremediation. In an aqueous solution where the processes of oxidation and reduction are occurring, one measures the potential to determine if this is an oxidizing or reducing environment. Like ph the ORP represents an intensity factor, it does not characterize the capacity of a system for oxidation or reduction similar to the way ph does not characterize the buffering capacity of a solution. To better understand this measurement we must start at the definition of ORP and progress through its limitation and interferences, as well as, its application in the remediation field. The measurement of Oxidation-Reduction Potential as a tool to assess the site condition for application of bio-remediation is somewhat removed from its original intent and therefore the use of this measurement must be judicious to arrive at an appropriate conclusion. Definition According to the EPA field manual, the Oxidation-Reduction Potential (E h ) is a measure of the equilibrium potential, relative to the standard hydrogen electrode, developed at the interface between a noble metal electrode and an aqueous solution containing electro-active redox species. This definition is similar to those found in instrumental chemistry books, Electrode potentials are defined as cell potentials for a cell consisting of the electrode in question behaving as a cathode and a standard hydrogen electrode acting as the anode. The electrode potential is in fact the potential of an electrochemical cell involving a carefully defined reference electrode. One key takeaway is that measured potentials are in fact relative to a specific reference cell, such as the hydrogen electrode. Half Reaction The half reaction is Ox v + n e - Red (v-n) (reduction reaction) Where v is the valence state of the target species prior to reduction, n is the number of electrons transferred and (v-n) is the reduced species valence state. This is called a half reaction because we are only seeing one half of the oxidation/reduction couple, the

other half reaction is hydrogen oxidation measured at the reference hydrogen electrode. H 2 + 2e - 2H + (oxidation reaction) Hydrogen and Reference and Sensing Electrodes The hydrogen electrode is a reference electrode that has its potential arbitrarily set at 0.0 mv. However, because the hydrogen electrode is difficult to use in the field or laboratory, other electrodes are used as the reference electrode. These electrodes are characterized by having very stable potentials and are highly reproducible. For example two widely used reference electrodes are: Saturated Calomel 0.241 mv (E h ) Hg 2 Cl 2 + 2e - 2Hg + 2Cl - Silver Chloride (1.0 M KCl) 0.222 mv (E h ) AgCl + 2e - Ag(s) + Cl - As a result, the measured value of ORP will vary depending on the reference electrode chosen. Additionally the correct filling solution for the electrolyte in the reference electrode of choice must be used. Knowing which reference electrode is being employed allows it to be related back to the hydrogen electrode reference. The sensing electrode is usually a platinum surface where the Redox reactions occur. In the case of measuring ph, the sensing electrode it is a glass electrode. Like a ph electrode that uses buffer solutions to standardize the instrument, there is a reference solution, ZoBell s (E o = 430 vs. E h at 25 0 C) that is used to standardize ORP instruments. Redox measurements (E h ) on a platinum electrode are valid only in solutions that contain electro-active species present in solution. Measurements should not be carried out without an awareness of the interferences and limitations inherent with ORP method. Organic matter and sulfide may cause contamination of the electrode surface which can cause erratic performance. In addition, hydrogen sulfide can produce a coating on platinum that can interfere with measurement. Platinum single or combination electrodes may yield unstable readings in solutions containing chromium, uranium, vanadium or titanium ions, as well as other ions that are stronger reducing agents than hydrogen.

ORP Measurement As ph is a measure of the hydrogen ion concentration in water or the acidity or alkalinity of a system. ORP is a measure of the overall oxidizing or reducing condition of a system. The ORP measurement is a direct potentiometric measurement of the equilibrium established between ALL oxidizing and reducing reactions in solution and is governed by the Nernst equation E = E o + RT/nF(ln Aox/Ared) E = potential developed at the electrode E o = Constant dependent on reference electrode R = gas constant T = temperature in 0 Kelvin n = number of electrons transferred F = Faraday s constant Aox = activity of oxidized species [directly related to the concentration of oxidized species] Ared = activity of the reduced species [directly related to the concentration of reduced species] The ORP reading should be reported versus the normal hydrogen electrode E h = E obs + E ref Measurement of ORP is made using an electrode pair consisting of an electrode pare consisting of a reference electrode, sensing electrode and a high input impedance meter. As an example, take the redox couple Fe(II) and Fe(III) with the following equation Fe +3 + e - = Fe +2 From the Nernst equation:, where t is the temperature in C, n = 1 for this case. At 25 C, if the ratio of Fe +2 concentration to Fe +3 concentration is a factor of ten, then E = -59.2 mv. If the concentration ratio is a factor of 0.1, then E = 59.2 mv.

Use of ORP readings Bioremediation processes may be monitored indirectly by measuring the Oxidation - Reduction Potential. However this measurement must be accompanied by ph, temperature and oxygen content, electron acceptor/donor concentration and concentration of breakdown products. Some of the biological breakdown reactions as a function of the redox potential are shown below Aerobic Anaerobic O 2 + 4e - + 4H + 2H 2 O 600-400 mv vs. E h - 2NO 3 + 10e - + 12H + N 2 + 6H 2 O 500-200 mv vs. E h MnO 2 + 2e - + 4H + Mn +2 + 2H 2 O 400-200 mv vs. E h Fe(OH) 3 + e - + 3H + Fe +2 + 3H 2 O 300-100 mv vs. E h SO 4 = 0.0 - -150 mv vs. E h + 8e - + 10H + H 2 S + 4H 2 O These equations are for very specific reactions. The E h value is highly dependent on the ph [H + ]. Note that the potential of two of the anaerobic reactions nitrate and manganese dioxide reduction can be within the aerobic potential range. As a result conclusions based on ORP measurement should not be in isolation, and should be supplemented by other measurements to have a meaningful relationship to the processes that are in the environment. However, ORP measurement is useful in assessing the general overall electro-potential state of the environment, indicating the general presence of oxidized or reduced states of metals and salts, thus giving an indication of the potential predominant chemical and biological processes that may be occurring. The Impact of ph ph can have a profound influence on ORP measurements. As an example, a common chemical reaction that takes place during bleaching or disinfection with chlorine is: HOCl + H + + 2e - = Cl - + H2O

In writing out the Nernst equation, [H + ] appears: As a result, electrode potentials specifically can be a function of ph [hydrogen ion concentration]. As a demonstration, an Accumet ORP probe (Cat# 13-620-115) with platinum tip was used to determine ORP and an Accumet Ag/AgCl Reference electrode (Cat# 13-620-53) was used as a reference. The Accumet reference probe was filled with 4M KCl. These electrodes were connected to a Fluke 21III Multimeter to determine voltage from the system. The ORP of distilled water as a function of ph is shown in Table 1. ph Actual ph mv 9 9.05 163.4 10 10.03 83.6 11 10.99 59.2 12 11.99 22.9 Table 1 As ph increases, the measured ORP value decreases. Several users of Klozur Persulfate have remarked that the ORP of a concentrated solution of persulfate and sodium hydroxide (batched in preparation for high ph activated persulfate ISCO field remediation) are more negative after addition of the sodium hydroxide. Table 2 shows the decrease in ORP measurement for a 20 wt% persulfate solution with an increase in ph (measured under the same conditions as Table 1): ph Actual ph mv 9 8.95 685 10 10.01 627 11 10.98 606 12 11.96 575 Table 2 Thus, even in the presence of a highly oxidizing species such as persulfate, the ORP values can be greatly impacted by an increase in ph, and in some instances, negative ORP readings have been reported for NaOH persulfate solutions. This does not mean that persulfate is no longer acting as an oxidizer For a given ph, as long as the potential of the half cell reaction for persulfate is more positive than the corresponding potential of the half cell reaction for the contaminant reaction, persulfate will act as an oxidant, even if the persulfate half cell is negative with respect to the reference electrode. It is

the relative difference of the two half-cell potentials that dictate the oxidation - reduction reactions, instead of the absolute, measured ORP value. Conclusions ORP measurements are an invaluable tool to measuring changes in subsurface chemistry. However, their value is diminished if used in isolation without understanding other groundwater parameters such as ph and metal concentrations. In isolation, and ORP measurement can be misleading. It is best to use ORP change as a tool to look at the impact of chemical and biological changes on groundwater chemistry.