PRODUCT ACCEPTANCE STANDARD FOR CUSTOM LAMINATED GLASS

Similar documents
TECHNICAL BULLETIN TECHNICAL DESCRIPTION DESCRIPTION OVERVIEW PROGRAMS. Data Sheet. Pilkington Toughened Safety Glass

Standard Specification for Flat Glass 1

SPECIFICATION Aluminum Module Frames. Allowed anodization before fabrication for clear frames.

INFORMATION REGARDING GLASS TYPES AND PROPERTIES

Standard Specification for Laminated Architectural Flat Glass 1

Heat-treated Glass. GUARDIAN A Company of Vision PATTERNED GLASS HORTICULTURAL GLASS SUN PERFORMANCE GLASS VISION GLASS SILKSCREENED GLASS THIN GLASS

New Product Announcement

TECHNICAL SPECIFICATION SERIES 8000 PRECAST CONCRETE

IHSS-N1 WELDED HONEYCOMB CORE SPECIFICATION. Generated: Sergiy Papyshev Engineering. Approved: Don Prysi Manufacturing. Approved: Merzuk Ramic Quality

SCENIC VIEW SV 10 SECTION SOLAR CONTROL FILMS

Glass and Building Regulations Impact Safety

March 14, Installation of Bay, Bow and Garden Windows

MOOG. MACHINING SUPPLIER WORKMANSHIP STANDARDS Issue: 1-APRIL- 2007

Window Glass Design 5 According to ASTM E 1300

Handling, Inspecting, Fabricating & Glazing Pilkington Solar-E on Tinted Glass

GENERAL TRADING TERMS (GTT) RMC by EUROSURFACES

Quality Regulations for Profiles

3 Masonry and Manufactured Stone (Interior and Exterior)

EXPANDED POLYSTYRENE (EPS) INSULATION BOARD SPECIFICATIONS

ENGINEERING SPECIFICATION FIBERGRATE MOLDED GRATING. January 24,

Technical Guide for Glass Cutting Section 1 - Two Basic Types of Cutting

General (1) This Section applies to the design and construction of interior and exterior stairs, steps, ramps, railings and guards.

Sun Windows General Information Sun New Construction Window Installation Instructions

SERIES 238 WINDOWS. NOTE: Read instructions completely before attempting any installation.

Code of Standard Practice for Timber Frame Structures

SECTION ALUMINUM FRAMED ENTRANCES and STOREFRONTS. System 402 Flush-Glazed Screw Spline Storefront

Gunite Disc Brake Rotors

Roller Wave Distortion Definition, Causes and a Novel Approach to Accurate, On-line Measurement

GUIDELINES. for oversize and overmass vehicles and loads MAY Government of South Australia. Department for Transport, Energy and Infrastructure

AST M F /GSA TS01 T EST R EPO R T. Rendered to: UNI T E D ST A T ES A L U M INU M

glass & Glazing Products

CERTIFICATE OF APPROVAL No CF 291 SCHOTT UK LIMITED

Calvert USA, Inc. Attic Stairs

September 1, 2003 CONCRETE MANUAL CONCRETE PAVEMENT REHABILITATION

Important Information

ADA POST INSPECTION CHECKLIST. Job No. Route County Location

Traditional Drawing Tools

BENTLEY ELEMENTS COLLECTION LVT

KITCHENS. Tip PAGE 1 FITTING YOUR KITCHEN GUIDE. How to mark out a kitchen. Tools required for installing a kitchen STEP ONE STEP TWO STEP THREE

VC 104+ Rigid Grade / Rigid Grade Imagine VC 104 Rigid Grade Commercial Customised

RAILWAY EQUIPMENT REFLECTORIZATION RULES

BRAKE DRUM AND ROTOR SERVICE INFORMATION

EN Insulating glass units, intended to be used in buildings and construction works

AISI CHEMICAL COMPOSITION LIMITS: Nonresulphurized Carbon Steels

Pyroguard Wired Glass

VCE VET ENGINEERING STUDIES

Figure 1 Wafer with Notch

INTERGOVERNMENTAL STANDARD GOST

Glossary. 1/3 1/3 1/3 - Configuration of a vent-fixed-vent (xox) window in which the vents and fixed panel are equal sizes

1.4 Metallic Impurities Iron must not exceed 150 ppm and copper shall not exceed 6 ppm when tested according to TAPPI T 266.

Installation Instructions

Pilkington Reflite Handling and Processing Guidelines Solar Control

SECTION SECTIONAL OVERHEAD DOORS 521 SERIES ALUMINUM SECTIONAL OVERHEAD DOORS

CERTIFICATE NAME OF PRODUCT MANUFACTURER PRODUCT DESCRIPTION CERTIFICATION PROCEDURE. No VTT C Date of issue , Updated July 1, 2011

Beautifully Traditional

Removing chips is a method for producing plastic threads of small diameters and high batches, which cause frequent failures of thread punches.

Fixed Access Ladders. Table of Contents. 1. Legislative Requirements

SECTION METAL WALL PANELS

TECHNISCHE FICHE - TECHNISCHE FICHE - Chat Board: Classic

Florida Building Code 2004 SECTION 1009 STAIRWAYS AND HANDRAILS

Nanping Weishi LVL Scaffold Plank Brochure

PERFORMANCE GUIDELINES

Crimp Tooling Where Form Meets Function

6 Design of Gates. 6.1 The Sprue Gate


Solid shape molding is not desired in injection molding due to following reasons.

Quality assurance of flex circuits in the SCT barrel hybrid production

Shower Walls and Tub Surrounds

Product Data Sheet PDS050: ArmourFX polished plaster and decorative paint panels

HS-Steel-Classic. Curing chambers for the concrete block industry in a proven steel version

BGA - Ball Grid Array Inspection Workshop. Bob Willis leadfreesoldering.com

DSM 1 (800)

SECTION 1: REQUIREMENTS FOR CERTIFICATES OF COMPLIANCE FOR CLASSES OF RADIATION SOURCES

How to Install Drop Ceiling Panels

Sprinkler Identification Number. Page 1 of 6 MARCH 2014 TFP288. Worldwide Contacts.

SCHOTT PYRANOVA Planline System

Engineering & Design: Coordinate Dimensioning

PRODUCTBLADEN GT ROCKPANEL STRUCTURE

Packaged Terminal Air Conditioner Wall Sleeve Installation

Tundra Series Windows January 2016

Agilent X/P/K281C Adapters

Understanding BS EN 771-3: Aggregate concrete masonry units

Clad Direct Glaze Window Installation Instructions

W1T 1HQ Copied for information to: Nigel Woods & Cem Suleyman Consumer Focus 4 th floor, Artillery House Artillery Row

HDA

INTER PLANT STANDARD STEEL INDUSTRY

SKY-TILE SKY-TILE. Daylight Consultants web: blog: espaciosolar.blogspot.com. Bioclimatic Modular Skylights

Number of Sides Required to Have a Handrail

Technical Regulations

Metal Pressfitting Pipe Systems

Kids Woven - Minimum Construction Standards

GUARDRAIL POST STEEL

Walking and Working Surface Checklist:

Window Installation Instructions

SWIMMING POOL, SPA, & HOT TUB GUIDELINES

F1 in Schools World Finals Technical Regulations WORLD FINALS Technical Regulations

The Layman's Guide to ANSI, CEN, and ISO Bar Code Print Quality Documents

Kempsville Volunteer Rescue Squad. Ambulance Graphics Package

Photographs: Acceptable, Unacceptable, and Unacceptably Repaired Precast Concrete Products

Transcription:

5 Brandwood Street Royal Park SA 5014 Ph: 8447 6444 Fax: 8240 0916 SCOPE PRODUCT ACCEPTANCE STANDARD FOR CUSTOM LAMINATED GLASS 1. STANDARDS COMPLIANCE 2. IDENTIFICATION LABEL 3. PRODUCT RANGE 4. SIZE RANGE 5. MINIMUM CHARGE 6. DIMENSIONAL TOLERANCES 7. SURFACE QUALITY 8. EDGE QUALITY 9. INTERLAYER SNAP BACK / SHRINKAGE / DELAMINATION 10. INTERLAYER BUBBLES 1. STANDARDS COMPLIANCE Chevron Custom Laminated products are supplied in accordance with this Product Acceptance Standard and conform to the following Australian Standards. AS/ NZS 2208 Safety Glazing Materials in Buildings AS/ NZS 2080 Safety Glass for Land Vehicles AS 1288 Glass in Buildings-Selection & Installation AS/ NZS 4667 Quality requirements for cut to size and processed glass A Certificate of Compliance can be supplied on request. 2. IDENTIFICATION LABEL All Chevron Custom Laminated products will be supplied with an appropriate Chevron Glass label. This label verifies manufacture by Chevron Glass, our licence number, glass thickness and conformity to AS/ NZS 2208 or AS/ NZS 2080 standards certification. For example, Individual panels of toughened glass incorporated into a custom laminated product are not stamped. Page 1 of 5

3. PRODUCT RANGE Annealed Laminated Glass Heat Strengthened Laminated Glass Toughened Laminated Glass All toughened substances must have a minimum of 1.52mm interlayer. 4. SIZE RANGE MINIMUM SIZE 100 X 350mm. MAXIMUM SIZE Length 4000mm (Refer to Production). Width depends on laminate size. MAXIMUM WEIGHT 350kg/m 2 per make-up. 5. MINIMUM CHARGE A minimum area charge of 1m 2 per panel applies. 6. DIMENSIONAL TOLERANCES 6.1 SIZE: Length/width (tolerance) for glass < 1200mm Length/width (tolerance) for glass > 1200mm Glass Thickness < 10mm Glass Thickness > 10mm + 2mm + 2mm + 2mm + 3mm Page 2 of 5

6.2 SQUARENESS: Maximum difference in diagonals is 5mm for panels with the largest dimension less than 1200mm, or 10mm maximum if the largest dimension is greater than 1200mm. 6.3 MISALIGNMENT: Edge slip of up to 3mm between glass components is acceptable. 6.4 BOW: Not to exceed 1:300 when glass in standing vertically. Total bow across panel is not to exceed 10mm in depth. 6.5 HOLES: Misalignment of holes is acceptable, provided it does not exceed 4mm. 7. SURFACE QUALITY The glass is to be inspected in transmission (looking through the glass) at a distance of 3 metres at a viewing angle of 90 (perpendicular) to the surface and as normally viewed using daylight without direct sunlight or with a background light suitable for observing imperfections. Scratches, scars, surface marks and imperfections are acceptable if not readily visible from the viewing distance. 7.1 ROLLER WAVE DISTORTION An inherent consequence of the heat treatment process is roller wave which is caused by the heated, slightly softened glass being in continual contact with the oscillating ceramic rollers. This distortion is more noticeable in reflective or dark tinted glasses and if applicable, the direction of roller wave should be specified. Roller wave on heat strengthened and toughened laminated glass not to exceed 0.15mm over 300mm. Edge kink not to exceed 0.25mm in 300mm. Page 3 of 5

8. EDGE QUALITY 8.1 CLEAN CUT Maximum shelling and flanging to be no more than 50% of the total substance thickness and to a maximum of 5mm in from the edge. 8.2 ARRISSED EDGE Chips and shells are acceptable provided they: Extend no greater than 5mm from the edge of the glass. Do not exceed half the glass thickness. Are not vented. 8.3 FLAT SMOOTH / FLAT GROUND EDGE No shells are permitted. Grind marks are permitted but must be of light intensity (not visible at greater than 900mm). Chips and shells are permitted provided they: Extend no greater than 2mm from the edge of the panel. Extend no greater than 2mm into the glass thickness. 8.4 FLAT POLISHED EDGE Finish and arris must be uniform. Chips and shells are not permitted. 8.5 MITRED EDGES As for flat smooth / flat ground (8.3). Vented edges are not permitted. 9. INTERLAYER SNAP BACK / SHRINKAGE / EDGE DELAMINATION Laminated glass within specification may exhibit a measure of delamination. From any edge of the laminate interlayer, snap back, shrinkage or delamination is acceptable if no more than: 6mm for laminates containing 0.76mm interlayer. 10mm for laminates containing 1.14mm and 1.52mm interlayer. Page 4 of 5

10. INTERLAYER BUBBLES Acceptable if not visible from a viewing distance of 3 metres. Bubble/Inclusion Up to 2.5m2 Over 2.5m2 <1.0mm No limit No limit 1.0mm 5.0mm 2 4 Effective: 01/02/14 Replaces: 01/04/11 Page 5 of 5