New Product Announcement
|
|
|
- Bertram Robinson
- 9 years ago
- Views:
Transcription
1
2 New Product Announcement Tristar Glass is now the exclusive provider of Schott PYRAN Platinum Fire- and Safety-Rated Glass-Ceramics for Arkansas, Oklahoma, and Texas. Tristar is giving our select network of glaziers immediate access to cutting-edge, UL-certified, fire-rated glass in 3 options: monolithic, filmed, and laminated. Outlined in this brochure are the reasons Schott s PYRAN Platinum fire- and safety-rated glass-ceramics are the best choice for your fire-protective glazing project. Clearest Glass-Ceramic available no yellow or orange tint No wires means no danger and no unsightly lines In-Stock and Ready-To-Go; no more long lead times and cross-country freight and boxing fees UL certified and passes required hose stream test PYRAN Platinum F and L pass ANSI Z97.1 and CPCS 16CFR1201 (Cat I and II) impact testing and are approved for hazardous areas Cradle-to-cradle (C2C) Silver Certified meaning good for the environment and qualifies for LEED credits Can be used to construct insulated glazing units Simplified Ordering Process By answering a few basic questions your Tristar Glass sales representative will have all the necessary information to quote your fire-rated glass project: 1. Determine glass quantities and sizes 2. Determine if any of the glass is in a door or side-lite application, or if it can be annealed 3. Determine the appropriate fire rating requirement 1120 Main Parkway Catoosa, OK tristarglass.com fax toll free fax
3 PYRAN Platinum Glass Options By stocking all three of Schott s PYRAN Platinum glass products, Tristar gives you the flexibility to find the right fire-rated glass type that adequately meets the required fire standards of your project while minimizing the impact to your wallet. Below is a short outline of the three available products and their most common uses. Monolithic PYRAN Platinum monolithic fire-protection rated glazing material is 3/16 (5mm) thick and weighs 2.5 lbs/ft2. It is intended for use in non-impact, non-safety-rated locations such as transoms and windows with fire-rating requirements up to 90 minutes. Maximum sheet sizes: Approximately 43 x 77 Impact rating: None Filmed PYRAN Platinum F fire-protection rated and impact safety-rated glazing material is 3/16 (5mm) thick and weighs just 2.5 lbs/ft2. It has a surface applied safety film and is intended for use in safety-rated locations such as door lites, transoms or sidelites, and windows with fire-rating requirements up to 90 minutes (180 minutes in doors). Maximum Sheet size: Approximately 43 x77. Impact rating: ANSI Z97.1 and CPSC 16CFR1201 (Cat. I and II) Laminated PYRAN Platinum L fire-protection rated and impact safety-rated glazing material is 3/8 (9mm) thick and weighs just 4.0 lbs/ft2. It is intended for use in safety-rated locations such as door lites, transoms or sidelites, and windows with fire-rating requirements up to 90 minutes (180 minutes in doors). Maximum Sheet size: Approximately 43 x77. Impact rating: ANSI Z97.1 and CPSC 16CFR1201 (Cat. I and II) STC Rating: Approximately 36 db MONOLITHIC FILMED LAMINATED
4 BENEFITS Acquaint Yourself with some of PYRAN Platinum s benefits and learn first hand why Schott s fire rated glass products are the best in the world. In Stock and Ready-to-Go Our ready-to-go stock of PYRAN Platinum fire-rated glass means no more long lead-times and cross-country freight fees. Get the glass you want, when you need it delivered on the same trucks you see every day. Clearly Defined Safety Schott PYRAN Platinum fire-rated glass-ceramic products represent the next generation of glass-ceramic technology, offering stunning optical quality, superior clarity, and virtually no distortion. Through recent advancements in micro-float technology, Schott has been able to eliminate the unsightly yellow and orange tints associated with other fire-rated glass and no longer require corrective polishing or grinding to achieve superb optical quality. All this helps to maximize natural lighting and views, eliminating compromises in spaces that otherwise would have sacrificed form for function. Wireless The 2006 International Building Code (IBC) no longer permits the use of wired glass in hazardous locations in all facility types. PYRAN Platinum F and L fire-rated glass-ceramic products provide glaziers with a wire-free, impact safety glazing that passes both the ANSI Z97.1 and the CPSC 16CFR1201 (Cat. I and II) and is approved for use in hazardous locations. Choose PYRAN Platinum, a superior fire-rated product, and avoid unsightly lines and the ever-growing negative stigma surrounding wired glass. Earn LEED Credits and Help the Environment PYRAN Platinum is the only fire-rated glass-ceramic that is made without the use of hazardous heavy metals such as antimony, arsenic, and barium. It is also the only glass-ceramic to receive a Cradle-to-Cradle silver level certification from the MBDC and qualify as one of the EPA s Environmentally Preferable Products (EPP), potentially earning a project up to 5 LEED certification points.
5 CERTIFICATION PYRAN Platinum Monolithic Rating (Min.) Location Max Exposed area of glazing (in. 2 ) Max width of exposed glazing (in.) Max height of exposed glazing (in.) Min depth of glazing channel Impact Safety Rated Up to 90 Other than Doors 3422 (23.7 ft2) /8 No PYRAN Platinum F Filmed PYRAN Platinum L Laminated Up to 90 Doors Non-Temp Rise 2736 (19 ft2) /8 Yes Doors Temp Rise and Up to (.69 ft2) /2 Yes Non-Temp Rise up to 90 Other than Doors 3422 (23.7 ft2) /8 Yes Up to 90 Doors Non-Temp Rise 2736 (19 ft2) /8 Yes Doors Temp Rise and Up to 180 Non-Temp Rise 100 (.69 ft2) /2 Yes up to 90 Other than Doors 3143 (21.8 ft2) /8 Yes UL Certified PYRAN Platinum fire- and safety-rated glass-ceramics are Classified and labeled by Underwriters Laboratories, Inc. for the United States and Canada with File-No. R All fire tests were performed in accordance with UL 9, UL 10B, UL 10C, UBC 7-2 (1997), UBC 7-4 (1997), NFPA 252, NFPA 257, NFPA 80, ASTM E , ASTM E , ULC CAN4-S104, and ULC CAN4-S106 The Hose Stream Test and The Ability to Withstand Thermal Shock The hose stream test is a mandatory procedure required by The National Fire Protection Association (NFPA). Their standards for Window and Glass Block Assemblies state, the hose stream test provides a method for evaluating the integrity of constructions and assemblies and for eliminating inadequate materials or constructions. The cooling, impact, and erosion effects of the hose stream provide important tests of the integrity of the specimen being evaluated. The hose stream test is conducted by spraying 30psi water from a fire hose onto the glass while the glass and the framing system are still hot. The thermal shock created on the system during this test must not cause the glass to fail and, in turn, allow fire and smoke to spread. F I R E R A T E D G L A S S
6 Storage and Handling PYRAN Platinum fire- and safety-rated glass-ceramics should be handled with care during transportation, storage, inspection, and installation. It should be stored in dry conditions only and must be stacked upright or at a slight angle. In addition, an appropriate material, such as soft pads made of cork (Platinum and Laminated) or acid free tissue paper (filmed), must separate the panels and the bottom edge must be supported along its entire length. Installation GLAZING GUIDE PYRAN Platinum products shall only be installed into fire-rated frame and window assemblies carrying the same rating. Each panel should be inspected carefully before installation, and any pieces with visible edge or surface damage should be sorted out. All glazing components and the stop height must be chosen according to the PYRAN Platinum product classification. The panel must be placed on calcium silicate or hardwood setting blocks and glazed using PYRAN Platinum classified glazing tape, such as closed cell PVC, Fiberfrax tape or Pemko FG The installation of the framed unit must comply with the frame supplier s instructions. PYRAN Platinum products are specially developed glass-ceramics, which fulfill the fire protection rating requirements. The production process may create certain optical imperfections, such as bubbles or knots. Since these do not generally impair the transparency or the technical performance of the glass-ceramic, they do not represent cause for rejection or replacement. Maintenance and Care To maintain the aesthetics, it is important to keep the panel clean. A soft, non-abrasive cloth and a mild soap, detergent, or non-abrasive window cleaning solution is suitable for cleaning. After cleaning, rinse immediately with clean water and remove any excess water from the panel surface. Also, do not allow any metal or hard parts of the cleaning equipment to come in contact with the panel surface Main Parkway Catoosa, OK tristarglass.com fax toll free fax
7 WARRANTY INDIVIDUAL PRODUCT WARRANTIES PYRAN Platinum Glass-Ceramic Limited 5-Year Warranty SCHOTT North America, Inc. ( SCHOTT ) warrants that, at the time of purchase from SCHOTT, the PYRAN Platinum glass-ceramic (the Product ) will conform to SCHOTT s then current Product specifications. This warranty is only made to and is limited to the original purchaser of the Product from SCHOTT ( Purchaser ). No warranty claim is valid under this warranty unless the warranty claim is made within thirty (30) days of the date of purchase. PYRAN Platinum F Glass-Ceramic Limited 3-Year Warranty SCHOTT North America, Inc. ( SCHOTT ) warrants that, at the time of purchase from SCHOTT, the PYRAN Platinum F glass- ceramic (the Product ) will conform to SCHOTT s then current Product specifications. SCHOTT also warrants that for a period of three (3) years from the date of original purchase from SCHOTT (the Warranty Period ), the Product will maintain adhesion without crazing, delaminating, or peeling. These warranties are only made to and are limited to the original purchaser of the Product from SCHOTT ( Purchaser ). No warranty claim is valid under this warranty unless the warranty claim is made within thirty (30) days of either A) the failure of the Product to maintain adhesion without crazing, delaminating, or peeling or B) the date of purchase, if the claim is that the Product does not conform to SCHOTT s specifications. PYRAN Platinum L Glass-Ceramic Limited 5-Year Warranty SCHOTT North America, Inc. ( SCHOTT ) warrants that, at the time of purchase from SCHOTT, the PYRAN Platinum L glass-ceramic (the Product ) will conform to SCHOTT s current Product specifications applicable to the Product at the time of purchase. SCHOTT also warrants that, for a period of five (5) years from the date of the original purchase from SCHOTT (the Warranty Period ), the Product will be free from manufacturing defects that cause significant visual disruption through the glass area, delamination, or material changes to the properties of the interlayer. These warranties are only made to and are limited to the original purchaser of the Product from SCHOTT ( Purchaser ). No warranty claim is valid under this warranty unless the warranty claim is made within thirty (30) days of either A) the occurrence of significant visual disruption through the glass area, delamination, or material changes to the properties of the interlayer of the Product or B) the date of purchase, if the claim is that the Product does not conform to SCHOTT s specifications. MONOLITHIC FILMED LAMINATED Please Visit for a complete listing of warranty terms and conditions.
8 CALL TODAY FOR A FREE QUOTE Toll Free Phone: Toll Free Fax: Main Parkway Catoosa, OK [email protected] FIRE RATED GLASS GUIDE
Pyroguard Wired Glass
Fire-rated Glass Pyroguard Wired Glass Where glass becomes architecture Section 15 03 Introduction Oldcastle Glass stocks nonwired Pyroguard laminated safety glass and polished wired glass for commercial,
FIRE GLASS TO GO! Fire Glass Solutions from
Fire Glass Solutions from FIRE GLASS TO GO! INTRODUCING For almost 20 years, the company now trading as CGI International has been involved in the manufacture and distribution of specialist fireresisting
2010 edition. Handbook of. Fire-Rated Glass. for schools
Handbook of Fire-Rated Glass for schools 2010 edition The Rules have changed For decades, traditional wired glass has been the most common fire-rated glass product specified for schools in North America.
The 60 minute Fire Rated Application Explained
The 60 minute Fire Rated Application Explained One of the most confusing aspects of the code is the 60 minute fire rated application, and its easy to see why based on the questions that come up: Is 60
FAQ S FREQUENTLY ASKED QUESTIONS ABOUT FIRE AND IMPACT/SAFETY RATED GLAZING PRODUCTS
FAQ S FREQUENTLY ASKED QUESTIONS ABOUT FIRE AND IMPACT/SAFETY RATED GLAZING PRODUCTS 1. What are my primary options in fire-rated glass? The glass product most often associated with fire rating is polished
Fire-Rated Glass and Glazing START
Fire-Rated Glass and Glazing START www.pilkington.com/fire Fire-Rated Glass and Glazing Pilkington Fire Protection Glass North America 946 Kane Street, Suite A Toledo, OH 43612 Provider Number: J200 Course
From Wired Glass to Clear Solutions: Designing with Fire Rated Glass Today
From Wired Glass to Clear Solutions: Designing with Fire Rated Glass Today Presented by SAFTI FIRST Fire Rated Glazing Solutions ABSTRACT: This white paper provides readers with a solid understanding of
SCENIC VIEW SV 10 SECTION 08 87 13 SOLAR CONTROL FILMS
PART 1 GENERAL SCENIC VIEW SV 10 SECTION 08 87 13 SOLAR CONTROL FILMS 1.1 SUMMARY A. Optically clear dual reflective, neutral sputtered and aluminum metallized polyester film for solar control. 1.2 RELATED
BASIC FIRE DOOR REQUIREMENTS TECHNICAL DATA SHEET NO. 401
BASIC FIRE DOOR REQUIREMENTS SHEET NO. 401 Fire door openings are classified by their locations in the building. The location determines the length of exposure protection required, based on the potential
A ROAD MAP FOR YOUR CODE, SMOKE BARRIER & SMOKE PARTITION REQUIREMENTS
A ROAD MAP FOR YOUR CODE, SMOKE BARRIER & SMOKE PARTITION REQUIREMENTS International Code Council National Fire Protection Association Underwriters Laboratories Inc. 5203 Leesburg Pike, Suite 600 1 Batterymarch
Eggers meticulously-crafted door frames are rivaled only by their beauty, quality and lasting performance. Turning nature s beauty into works of art
D O O R F R A M E S Eggers meticulously-crafted door frames are rivaled only by their beauty, quality and lasting performance. Turning nature s beauty into works of art D O O R F R A M E S Eggers Industries
CERTIFICATE OF APPROVAL No CF 291 SCHOTT UK LIMITED
CERTIFICATE OF APPROVAL No CF 291 This is to certify that, in accordance with TS General Requirements for Certification of Fire Protection Products The undermentioned products of Drummond Road, Stafford.
SECTION 07 21 16 - PRE-ENGINEERED BUILDING BLANKET INSULATION
PROJECT ARCHITECT RESPONSIBILITY: This is a general specification guide, intended to be used by experienced construction professionals, in conjunction with good construction practice and professional judgment.
Basic Fire Door Requirements
TECHNICAL DATA SERIES S D I 118-01 Basic Fire Door Requirements 2001 Steel Door Institute STEEL DOOR INSTITUTE 30200 DETROIT ROAD - CLEVELAND, OHIO 44145 Technical Data Series SDI 118-2001 Basic Fire Door
EXPANDED POLYSTYRENE (EPS) INSULATION BOARD SPECIFICATIONS
EXPANDED POLYSTYRENE (EPS) INSULATION BOARD SPECIFICATIONS 1. SCOPE 1.1 This specification covers the type, physical properties and dimensions of Expanded Polystyrene Insulation Board intended for use
Technical Data Honeycomb Door Leaf 8-1-99
8--99 8-/8 8-7/8 B 8-/4 A A Dim. A Leaf Width B ELEVATION F DESIGN Vertical edge seams mechanically interlocked Square hinge and lock edges 4-/ x.4 full mortise hinge prep Gov. 60/6 cyl lock prep...prefix
VC 104+ Rigid Grade / Rigid Grade Imagine VC 104 Rigid Grade Commercial Customised
Page 1 of 6 instructions VC 104+ Rigid Grade / VC 104+ Rigid Grade Imagine / (for the rest of this document referred to as VC 104) can be applied to new and used trucks and trailers with painted rigid
SHARP SOLAR Frequently Asked Questions for PV Integrators Revised 05/04/2010
SHARP SOLAR Frequently Asked Questions for PV Integrators Revised 05/04/2010 How do I determine the PTC rating of a module? PTC refers to PVUSA Test Conditions, which were developed to test and compare
Pilkington Reflite Handling and Processing Guidelines Solar Control
Pilkington Reflite Handling and Processing Guidelines Solar Control Pilkington Reflite 1. Product description Pilkington Reflite is a hard, on-line coated, solar control glass, available in a range of
3 Scotch-Weld TM. Structural Adhesive Films AF 6 AF 10 AF 13. Technical Data July, 2001
3 Scotch-Weld TM Technical Data July, 2001 Introduction 3M Scotch-Weld AF 6, AF 10, AF 13 are unsupported, thermosetting adhesives in film form developed for the structural bonding of metals. These products
SECTION 08 5656 GUARDA SECURITY WINDOW SCREENS
Page 1 of 5 SECTION 08 5656 GUARDA SECURITY WINDOW SCREENS Guarda Security Window Screens in this specification are appropriate for use in windows, storefronts, curtain walls, vents, and any other applications
PYROSWISS VETROFLAM CONTRAFLAM
Fire-resistant glass solutions SYSTEMS Description VETROTECH SAINT-GOBAIN specialises in the manufacture of high performance fire-resistant glass products; from single panes of modified toughened glass
ENERGY SAVING WINDOW FILMS S LAR CONTROL
ENERGY SAVING WINDOW FILMS S LAR CONTROL Overview Managing Solar Heat Gain - Solar Control Window Film With an ever increasing need to achieve outstanding energy efficiency within buildings without compromising
Wetroom Panel (Concealed Fix)
Wetroom Panel (Concealed Fix) Instruction Manual DXFCPCF Important Information Toughened glass is completely safe for use in our shower enclosures and bath screens; providing our products are installed
Important Information
Single Door Quadrant Instruction Manual ESQ Important Information Toughened glass is completely safe for use in our shower enclosures and bath screens; providing our products are installed according to
Glass and Building Regulations Impact Safety
Glass and Building Regulations Impact Safety England and Wales Approved Document N Scotland Part P Northern Ireland Part V Foreword For new buildings, and for buildings subject to major refurbishment,
Standard Specification for Flat Glass 1
: C 1036 06 Standard Specification for Flat Glass 1 This standard is issued under the fixed designation C 1036; the number immediately following the designation indicates the year of original adoption
INSULATION FOR PRE-ENGINEERED METAL BUILDINGS. ROXUL SAFE 55 & 65 and ROXUL PLUS MB. Insulation for Pre-Engineered Metal Buildings
INSULATION FOR PRE-ENGINEERED METAL BUILDINGS ROXUL SAFE 55 & 65 and ROXUL PLUS MB Insulation for Pre-Engineered Metal Buildings ROXUL SAFE AND ROXUL PLUS MB Exterior Wall Insulation for Pre-Engineered
Retardants Inc. The Decision You Make May Save A Life! 123 Columbia Court North Suite 201 Chaska, MN 55318
Fire Barrier Moldable Putty+ Pads 123 Columbia Court North Suite 201 Chaska, MN 55318 952-448-7377 FAX:952-448-2613 e-mail: [email protected] Visit Our Web Site at www.fireretardantsinc.com Protecting
FIRE RATED GLAZING System Guide
SYSTEM GUIDE Issue date: 05-05-2015 Expiry date: 31-12-2016 System Guide Introduction Pyropanel Developments are specialists in fire rated glazing solutions, and our systems are designed for easy installation
Basement Window Installation Guide Hopper and Sliding
Basement Window Installation Guide Hopper and Sliding americancraftsmanwindows.com Project Requirements: Installation must comply with all applicable building codes. Existing window frame, wall and weatherresistant
INSTRUCTIONS FOR COORDINATION SECTION 06651 SOLID SURFACE FABRICATIONS
INSTRUCTIONS FOR COORDINATION SECTION 06651 SOLID SURFACE FABRICATIONS 1. Paragraph 1.02 Provide solid surface countertops at sinks locations. Provide solid surface window sills at drywall framing walls.
CHARISMA SHOWER/TUB DOOR INSTALLATION INSTRUCTIONS
CHARISMA SHOWER/TUB DOOR INSTALLATION INSTRUCTIONS IMPORTANT DreamLine reserves the right to alter, modify or redesign products at any time without prior notice. For the latest up-to-date technical drawings,
Scotchgard Multi-Layer Protective Film 1004
Scotchgard Multi-Layer Protective Film 1004 3 Technical Bulletin September, 2008 Scotchgard Multi-Layer Protective Film 1004 Application Kit (3M Part No. 70-0710-4666-1) includes: (clockwise) Heavy Duty
Gridstone Gypsum Ceiling Panels
Gold Bond brand 09 29 00/NGC Gridstone Gypsum Ceiling Panels Helping You Build Better With High-Quality Products And Resources Founded in 1925, National Gypsum is one of the world s largest producers of
CHAPTER 24 GLASS AND GLAZING
CHAPTER 24 GLASS AND GLAZING SECTION 2401 GENERAL 2401.1 Scope. The provisions of this chapter shall govern the materials, design, construction and quality of glass, lighttransmitting ceramic and light-transmitting
FIRESTOPPING & SMOKE SEALS
SPECIFICATION SECTION 07 84 00 FIRESTOPPING & SMOKE SEALS 1 GENERAL 1.1 SECTION INCLUDES 1.1.1 Comply with Division 1, General Requirements and Documents referred to therein. 1.1.2 It is the intent of
A. Work on this project shall consist of, but is not limited to, the following:
PART 1 - GENERAL CLEANING AND RESTORATION OF SECTION 05900-1 1.1 SUMMARY A. Work on this project shall consist of, but is not limited to, the following: 1. Clean and treat all exposed anodized architectural
Office of the State Fire Marshal. Fire Rated Doors
Office of the State Fire Marshal Fire Rated Doors Fire Rated Doors These doors serve a purpose. They are manufactured in a way that is to help reduce the spread of fire and smoke. Fire rated doors allow
HEAT WAVE DUCT KIT KIT # 946-568
HEAT WAVE DUCT KIT KIT # 946-568 www.regency-fire.com Approved for use with Models: P36, P36D, P42, P48, P90, P95, L676S, P33S & HZ54 WARNING: Improper installation, adjustment, alteration, service or
SECTION 08 41 1 ALUMINUM FRAMED ENTRANCES and STOREFRONTS. System 402 Flush-Glazed Screw Spline Storefront
PART 1 GENERAL 1.01 Work Included SECTION 08 41 1 ALUMINUM FRAMED ENTRANCES and STOREFRONTS System 402 Flush-Glazed Screw Spline Storefront A. Furnish and install aluminum architectural storefront system
INTEL S SAFETY WARNING LABEL REQUIREMENTS
INTEL S SAFETY WARNING LABEL REQUIREMENTS INTRODUCTION: Direction is provided on Intel s Safety Warning Label requirements to ensure suppliers provide equipment with hazards identified and the safety precautions
Built to Last. Built for Beauty. Good. Solid. Logix. TM
Built to Last. Built for Beauty. Good. Solid. Logix. TM Quality, Value and Service Introducing LOGIX Insulated Concrete Forms. Based on the simple concept of interlocking blocks, LOGIX ICF gives you a
IMPORTANT INFORMATION
Curved Quadrant Instruction Manual CQ IMPORTANT INFORMATION Toughened glass is completely safe for use in our shower enclosures and bath screens; providing our products are installed according to our guidelines.
Apr 17, 2000 LAB MANUAL 1811.0
Apr 17, 2000 LAB MANUAL 1811.0 1811 BULK SPECIFIC GRAVITY (GMB) AND DENSITY OF COMPACTED BITUMINOUS SPECIMENS USING PARAFFIN OR PARAFILM ASTM Designation D 1188 (MN/DOT Modified) 1811.1 SCOPE This test
Steel Door Institute. Fire Rated Doors and Frames
Steel Door Institute Fire Rated Doors and Frames 1 1. Nomenclature and Overview 2. Fire Rated Frames 3. SDI 118 4. Fire Rated Doors 5. Fire Rated Hardware 6. Specialty Products Table of Contents 2 Fire
Installation Guide of Sunrise Solartech PV Modules. Term 2013. Contents. Purpose of this guide. General. Safety precaution for installing a solar
Installation Guide of Sunrise Solartech PV Modules Term 2013 Contents Purpose of this guide General Safety precaution for installing a solar Photovoltaic system Product Identification Mechanical Installation
Teach me about Glazing
Teach me about Glazing Glazing can be categorized into three major groupings: 1. Fire-Rated Only (walls, transoms, borrowed lights) 2. Safety/Impact Rated Only (non-fire rated doors and other hazardous
Fire Barriers & Fire Stopping
Presented by: Bill Lauzon, PE Lauzon Life Safety Consulting, LLC 262-945-4567 [email protected] Web: Lauzon-LSC.com Environmental Part 2 Life Safety Code Chapter 8 Fire Barriers & Fire Stopping 1 Fire
Thermo-Flo Basement Waterproofing System. B-Dry System, Inc. 455 South 4th Street, Suite 350 Louisville, KY 40202
DEPARTMENT OF HOUSING AND URBAN DEVELOPMENT Housing - Federal Housing Commissioner Series and Series Number: MATERIALS RELEASE NO: (Supersedes issue dated May 23, 2007) 1199g TO: DIRECTORS, SINGLE FAMILY
TECHNICAL BULLETIN TECHNICAL DESCRIPTION DESCRIPTION OVERVIEW PROGRAMS. Data Sheet. Pilkington Toughened Safety Glass
Data Sheet Pilkington Toughened Safety Glass Introduction Pilkington has manufactured and marketed toughened glass for over 60 years. Its properties and performance have been proven in countless applications,
Underwriters Laboratories Testing Information
Underwriters Laboratories Testing Information R-8078 Underwriters Laboratories Inc. R-13173 Classified Spray Fiber Surface burning characteristics applied to inorganic reinforced cement board with a maximum
SPECIFICATION Aluminum Module Frames. Allowed anodization before fabrication for clear frames.
SPECIFICATION Allowed anodization before fabrication for clear frames. Page 2 of 9 1. SCOPE 1.1. This document provides general requirements for aluminum frames used in the assembly of photovoltaic modules.
Test Report No. C829QPEN
Institut für Solartechnik Hochschule für Technik Rapperswil Oberseestrasse 10, CH 8640 Rapperswil Tel +41 55 222 48 21, Fax +41 55 222 48 44 www.solarenergy.ch Ordered by: Westech Components Wuxi Co.,
GENERAL INSTALLATION MANUAL FOR EGING PV MODULES
GENERAL INSTALLATION MANUAL FOR EGING PV MODULES PLEASE READ THIS MANUAL CAREFULLY BEFORE INSTALLING OR USING THE MODULES. PLEASE PASS ALONG THE ATTACHED USER MANUAL TO YOUR CUSTOMER. 1. INTRODUCTION This
SECTION 07 42 13 METAL WALL PANELS
Mitsubishi Plastics Composites America, Inc. 401 Volvo Parkway Chesapeake, VA 23320 Phone: (800) 422-7270 Fax: (757) 436-1896 E-mail: [email protected] www.alpolic-northamerica.com This MANU-SPEC utilizes
Ceramic Glass Electric Galley Ranges
Ceramic Glass Electric Galley Ranges OWNER S MANUAL Models # 65335, 65336, 75331, 75332 Read all instructions and warnings before operating. Force 10 Manufacturing Corporation Unit A 19169 21 st Ave Surrey,
Automatic Door Selection Guide
Automatic Door Selection Guide AAADM 1300 Sumner Avenue Cleveland, OH 44115 P: 216-241-7333 F: 216-241-0105 [email protected] Automatic Door Selection Guide General: The members of AAADM manufacture an assortment
POZZI WINDOW COMPANY LIMITED WARRANTY WINDOWS, DOORS AND COMPONENT PARTS
POZZI WINDOW COMPANY LIMITED WARRANTY WINDOWS, DOORS AND COMPONENT PARTS POZZI WINDOW COMPANY warrants, subject to the conditions and restrictions contained below, that each window, door and component
FIRE-RESISTANT GLAZING Mr Leslie O May Sales Consultant Wright Style Limited England
FIRE-RESISTANT GLAZING Mr Leslie O May Sales Consultant Wright Style Limited England Fire is a life-threatening and destructive force, which if unchecked, can spread rapidly through a building. Every year,
Model KFR56 Series Quick Response Standard Spray
Bulletin 036 Model KFR56 Series Quick Response Standard Spray Bulletin 036 Model KFR56 Sprinkler Types Standard Upright Standard Pendent Horizontal Sidewall Model KFR56 Sprinkler Types Pendent F1/F2/FP
TECHNICAL DATA RS-6100. European Clear EZ. 5751 N. Webster Street Dayton, OH 45414-0802 Phone 937-890-6547 Toll Free 800-257-6547 Fax 937-890-6320
RS-6100 TECHNICAL DATA European Clear EZ DESCRIPTION: RS-6100 European Clear EZ is formulated with premium European resins. It is ideal for excellent color matching on white, light colors and metallics
Section 03 35 43 Polished Concrete Finishing. Vexcon
SS 120 1-13 Section 03 35 43 Polished Concrete Finishing Specifier Note: This product guide specification is written according to the Construction Specifications Institute (CSI) 3-part format. This section
Spandrel Glass Types and Recommendations
Spandrel Glass Types and Recommendations Introduction PPG has long offered recommendations regarding alternatives for glass spandrel applications. Over the years these recommendations were included in
GUIDELINES FOR INSTALLATION OF AIR CONDITIONING UNITS 174-180 PHILLIP STREET, SYDNEY
GUIDELINES FOR INSTALLATION OF AIR CONDITIONING UNITS 174-180 PHILLIP STREET, SYDNEY July 2008 1.0 SCOPE These guidelines describe the way in which air conditioning units shall be installed or replaced
Model WS Specific Application Window Sprinklers Horizontal and Pendent Vertical Sidewall 5.6 K-factor General Description
Worldwide Contacts www.tyco-fire.com Model WS Specific Application Window Sprinklers Horizontal and Pendent Vertical Sidewall 5.6 K-factor General Description The TYCO Model WS Specific Application Window
Fire-rated Aluminum Doors
Fire-rated Aluminum Doors Langebjergvænget 13 ALUFLAM has pioneered the innovative solution to what was long considered an impossible dream (and a barrier to truly beautiful commercial architectural design),
1.1.2 Polypropylene The polypropylene must be a white opaque film, 1 2 mil thick. Biaxial orientation is preferred.
Library of Congress Preservation Directorate Specification Number 700 704 09 Specifications for Pressure Sensitive Adhesive Labels For Application to Single Paper Sheets and Text Pages of Bound Books For
ENGINEERING SPECIFICATION FIBERGRATE MOLDED GRATING. January 24, 2014 06610-1
ENGINEERING SPECIFICATION FIBERGRATE MOLDED GRATING January 24, 2014 06610-1 SECTION 06610 FIBERGLASS REINFORCED PLASTICS (FRP) FABRICATIONS MOLDED GRATING PART 1 - GENERAL 1.1 SCOPE OF WORK A. The CONTRACTOR
SOLAR PV SYSTEM MAINTENANCE GUIDE
SOLAR PV SYSTEM MAINTENANCE GUIDE GUYANA HINTERLANDS STAND-ALONE SOLAR PV INSTALLATIONS IMPROVING HEALTH FACILITY INFRASTRUCTURE (IHFI) GUYANA CONTRACT NO. EPP-I-00-03-00008-00, TASK ORDER 07 APRIL 2013
3/4 PIPE CLAMP WITH STAND
3/4 PIPE CLAMP WITH STAND Model 94053 ASSEMBLY AND OPERATING INSTRUCTIONS (3/4 DIAMETER PIPE NOT INCLUDED.) 3491 Mission Oaks Blvd., Camarillo, CA 93011 Visit our Web site at: http://www.harborfreight.com
BENTLEY ELEMENTS COLLECTION LVT
This document refers to the following products: Product Size Installation direction Seams treatment Elements Tiles See specifications 90 None Elements Planks See specifications Stair Step None Note: This
Double Coated Urethane Foam Tapes
3 Double Coated Urethane Foam Tapes 4004 4008 4016 4026 4032 4052 4056 4085 Technical Data April, 2009 Product Description 3M Double Coated Urethane Foam Tapes are conformable foams that offer high shear
Terms and Definitions In Canada
Terms and Definitions In Canada Most of the following terms and definitions are taken directly from the National Building Code and referenced Test Methods. Learning these terms will provide an important
QWALL 4 ACRYLIC SHOWER WALL INSTALLATION INSTRUCTIONS
QWALL 4 ACRYLIC SHOWER WALL INSTALLATION INSTRUCTIONS IMPORTANT DreamLine TM reserves the right to alter, modify or redesign products at any time without prior notice. For the latest up-to-date technical
Specifying Windows. Performance Standards
1 Specifying Windows and ddoors Using Performance Standards 2 This program is registered with the AIA/CES for continuing professional education. As such, it does not include content that may be deemed
White rust on galvanized and galvanized pre-painted steel. Technical Information
Technical Information White rust on galvanised steel Prevention It is easier to prevent white rust than to cure it! Reasonable precautions to protect steel during both transport and storage can considerably
BUTTERFLY SHOWER DOOR INSTALLATION INSTRUCTIONS
BUTTERFLY SHOWER DOOR INSTALLATION INSTRUCTIONS IMPORTANT DreamLine reserves the right to alter, modify or redesign products at any time without prior notice. For the latest up-to-date technical drawings,
Dot matrix Label ID Products. C Vinyl cloth labels. Dot Matrix. Features and benefits. Part numbering system
Dot Matrix C Vinyl cloth labels Tyco Electronics C is a dot matrix printable vinyl coated cloth material with a permanent acrylic adhesive that is designed for application to irregular surfaces where conformability
1.4 Metallic Impurities Iron must not exceed 150 ppm and copper shall not exceed 6 ppm when tested according to TAPPI T 266.
Library of Congress Preservation Directorate Specification Number 100 132 09 Specifications for 3 x 10ʺ Paper Enclosures For the Storage of Strip Photographic Negatives This specification is provided as
Building Envelope Design by Roxul (BEDR ) FireWall and Roxul Plus MB. Fire Rated Board Insulation for Pre-Engineered Metal Buildings
BUILDING ENVELOPE DESIGN BY ROXUL Building Envelope Design by Roxul (BEDR ) FireWall and Roxul Plus MB Fire Rated Board Insulation for Pre-Engineered Metal Buildings ROXUL FIREWALL & ROXUL PLUS MB Exterior
FLEX-WRAP Foam Pipe Wrap
FLEX-WRAP Foam Pipe Wrap Flex-wrap Inexpensive Used to wrap all pipes in a concrete pour Satisfies UPC Code Sec.315.7 Provides true expansion space between pipe and a concrete pour Product # Dimesions
Fiberglas, Exterior Wall Thermal Insulation
PROJECT ENGINEER RESPONSIBILITY: This is a general specification guide, intended to be used by experienced construction professionals, in conjunction with good construction practice and professional judgment.
VERTICAL DESIGN OPTImAL ACOUSTICS
VERTICAL DESIGN OPTImAL ACOUSTICS 3 8 EnDLESS lines products possibilities Discover the family of products, vertically folding operable walls that unite design, performance, flexibility and acoustics.
Fire Barrier Duct Wrap 15A
3 Fire Barrier Duct Wrap 15A Commerical Kitchen Grease Duct Fire Protection System Product Data and Installation Instructions Compliance 1998 Edition Complies with International Mechanical Code Complies
3 Single-Coated Foam Tapes
3 Single-Coated Foam Tapes Technical Data May, 2008 Product Description 3M Single-Coated Foam Tapes will adhere to a variety of substrates, including latex-painted wood, lacquered wood, enameled steel,
Scottsdale, Arizona. Presentation by: Hermes Norero, P.E. President and CEO
Scottsdale, Arizona Presentation by: Hermes Norero, P.E. President and CEO Mr. Hermes F. Norero, P.E. is the founder and President of Building Drops. The concept of Building Drops first arose after realizing,
Subject: DKS Steel Door and Frames Systems, Inc., ITS / Warnock Hersey Procedural Specification, Certification, and Inspection.
DKS Customers Interested Parties State and Local Authorities Subject: DKS Steel Door and Frames Systems, Inc., ITS / Warnock Hersey Procedural Specification, Certification, and Inspection. All DKS products
Installation Instructions Double-Hung, Single-Hung, Casement, Awning, Sliding, Picture & Shapes Non-Impact & Impact Resistant Nailing Fin Windows
Installation Instructions Double-Hung, Single-Hung, Casement, Awning, Sliding, Picture & Shapes Non-Impact & Impact Resistant Nailing Fin Windows americancraftsmanwindows.com Project Requirements: Read
Sash or Balance Replacement Guide
Sash Balance Replacement Guide f Andersen 00 Series Woodwright Double-Hung Windows (Manufactured After October 8, 2006) and Woodwright Double-Hung Insert Windows Please read this guide completely befe
INSTALLATION INSTRUCTIONS
` 820 RT 910 Cheswick, PA 15024 412-828-3599 WORLD LEADER IN REMOVABLE HARDTOPS SMOOTHLINE.COM INSTALLATION INSTRUCTIONS Solstice/Sky Club Racer Thank you for purchasing the finest Hardtop available on
COMPACT LABEL APPLIER
COMPACT LABEL APPLIER MODEL CLAS-1LR CLAS-1RL ML-44227 ML-44228 701 S. RIDGE AVENUE TROY, OHIO 45374-0001 937 332-3000 www.hobartcorp.com FORM 35552 (February 2014) TABLE OF CONTENTS GENERAL... 3 INSTALLATION...
Sprinkler Identification Number. Page 1 of 6 MARCH 2014 TFP288. Worldwide Contacts. www.tyco-fire.com
Worldwide Contacts www.tyco-fire.com Model EC-HS 80 K-factor, Quick Response Extended Coverage Horizontal Sidewall Sprinklers Installations per VdS CEA 400, Annex E, LH/OH General Description The Model
PACKAGING & MATERIALS TESTING SERVICES
PACKAGING & MATERIALS TESTING SERVICES ENSURING CONFIDENCE IN PACKAGE PERFORMANCE TOTAL PACKAGING CONFIDENCE Packaging plays an essential role in promoting, protecting and transporting your products. Inadequate
RAILWAY EQUIPMENT REFLECTORIZATION RULES
RAILWAY EQUIPMENT REFLECTORIZATION RULES TC number TC O 0-56 Approved on February 27, 2006 Effective on May 1, 2006 Subsections 4.1 and 9.1 revised on and effective as of July 19, 2006 CONTENTS 1. Short
SECTION 08360 SECTIONAL OVERHEAD DOORS 521 SERIES ALUMINUM SECTIONAL OVERHEAD DOORS
SECTION 08360 SECTIONAL OVERHEAD DOORS 521 SERIES ALUMINUM SECTIONAL OVERHEAD DOORS Display hidden notes to specifier by using Tools / Options / View / Hidden Text. On newer versions of Microsoft Word
MEANS OF EXIT / ESCAPE / EGRESS SELF INSPECTION CHECKLIST
OPTIONAL INFORMATION Name of School: Date of Inspection: Vocational Program/Course/Room: Signature of Inspector: MEANS OF EXIT / ESCAPE / EGRESS Guidelines: This checklist covers some of the regulations
PERFORMANCE TEST REPORT. Rendered to: GLASSCRAFT DOOR COMPANY
Architectural Testing PERFORMANCE TEST REPORT Rendered to: GLASSCRAFT DOOR COMPANY SERIES/MODEL: Mahogany Entry Door PRODUCT TYPE: 6' x 8' Double Outswing Hardwood TDL Door with Half Circle TDL Transom