Nitrogen analysis is elementary

Similar documents
The art of elemental analysis

MILESTONE H E L P I N G C H E M I S T S

DMA-1 Direct Mercury Analyzer

FP628. Nitrogen / Protein Determination by Combustion. Rev 1-6/8/11

G8 GALILEO. Innovation with Integrity. High-End Melt-extraction Analyzer. Inert Gas Method

G4 ICARUS HF. Innovation with Integrity. Simultaneous Determination of Carbon and Sulfur in Solids. Combustion Method

Elemental analyzer multi EA 5000

ORGANIC SAMPLE PREPARATION

DMA-80 Direct Mercury Analyzer

Continuous flow direct water heating for potable hot water

Corona process The new ZEISS spectrometer system for the food industry

Adsorption air dryers ADS 1 215

MILESTONE START D. Microwave Digestion System

EuroFID Total Hydrocarbon Analyzer. Precise Determination of Total Hydrocarbons in Air for Corrosive as well as Condensing Gases

Graphite Furnace AA, Page 1 DETERMINATION OF METALS IN FOOD SAMPLES BY GRAPHITE FURNACE ATOMIC ABSORPTION SPECTROSCOPY (VERSION 1.

Kompressoren. Adsorption Dryer AD

Balancing chemical reaction equations (stoichiometry)

On-line Dissolved Gas Analysis

FMA-80 Fluorescence Mercury Analyzer

DigiBlock Sample Preparation System APPLICATION NOTES LABTECH INC. Your Lab, Our Tech

LNG Monitoring. Fiber-Optic Leakage Detection System. Pipeline leakage detection. Regasification and liquefaction monitoring

Top Technology for Industry, Agriculture, Business and Communities

German engineering under high pressure

Plant components, selected for sound performance

This chapter is devided into two sections:

Online Infrared Flue Gas Analyzer Gasboard 3000

DSC Differential Scanning Calorimeter

The Sievers 900 Series TOC Analyzers

Image Area EXCEPTIONAL PERFORMANCE FOR CHALLENGING MERCURY ANALYSES. FIMS 100 and 400. Flow Injection Mercury Systems

Application Requirement

Highly efficient flue gas analyzer

Measurement & Analytics Measurement made easy. MB3600-CH10 FT-NIR oleochemicals analyzer Pre-calibrated for Iodine Value (IV) and %Trans Fat

Phoenix Apollo Laboratory TOC Analyzers and Services Designed To Meet Your Needs


Introduction to Waste Treatment Technologies. Contents. Household waste

Visions become real. Temperature control and cooling systems. The innovative and reliable solution

Lightweight, compact, ergonomic, safe POLARIS FID. Portable TOC Analyser for Stack Emissions

MCP 100 MCP 150. Modular Compact Polarimeters. ::: Superior Optical Instruments

DETERMINATION OF TOTAL CARBON, TOTAL ORGANIC CARBON AND INORGANIC CARBON IN SEDIMENTS

Multi-elemental determination of gasoline using Agilent 5100 ICP-OES with oxygen injection and a temperature controlled spray chamber

Vacuum drying oven for non-flammable solvents

Determining the Quantity of Iron in a Vitamin Tablet. Evaluation copy

TRL-onlineTOC Monitor is designed for monitoring carbon content in

red-y smart series product information Thermal Mass Flow Meters and Controllers for Gases

Routine estimation of the Organic Matter content of soils by Loss on Ignition

Austin Peay State University Department of Chemistry CHEM Empirical Formula of a Compound

Incubator with mechanical convection

QuickCODultra. Online COD for every kind of water. Especially for the rough stuff. Fast. Precise. Reliable. COD-ANALYSis

In terms of food quality, you want to be absolutely confident that the results you get are reliable.

Unleash Your Potential

Advanced Solutions for Gas Monitoring

Discover Your Potential

Physical & Chemical Properties. Properties

dryon Processing Technology Drying / cooling in outstanding quality we process the future

Natural Resources. Air and Water Resources

Energy Efficient Operations and Maintenance Strategies for Boilers

Kompressoren. Compressed Air Filters PF/DF/MF/SF/AF

FORMATION DAMAGE AND WELL TREATMENT SYSTEM

Lecture 35: Atmosphere in Furnaces

12:10 Lysotherm : 5 jaar ervaring met innovatieve slibhydrolyse. Bert Geraats (Eliquo)

Assignment 8: Comparison of gasification, pyrolysis and combustion

Continuous Monitoring of Flue and Combustible or Hazardous Gases and Vapors

HySTAT HYDROGEN GENERATORS

1/11 CO2 DOSAGE SYSTEMS. CO2 dosage system consists of following parts;

GC-xt. The most flexible GC /GC-MS liquid sample injector

Mechanical Systems Competency 1.20

10 Nuclear Power Reactors Figure 10.1

1.3 Properties of Coal

XFA 600 Thermal Diffusivity Thermal Conductivity

Take the complication out of cooling. Data center cooling equipment and service from Alfa Laval

Colorimetric Determination of Iron in Vitamin Tablets

COMBIMASS. Technical Data COMBIMASS eco-bio +

italtec PRINTED CIRCUITS EQUIPMENT PRINTED CIRCUITS EQUIPMENT Insulator machines Echting machines Special equipment and machines

Customized Nutritional Solutions For Laboratory Animals

CONTENTS. ZVU Engineering a.s., Member of ZVU Group, WASTE HEAT BOILERS Page 2

Micro GC Fusion Pre-Installation Checklist

VTS³ and VCS³ Stress Screening Systems. More Power for Maximum Quality Assurance

HMHF DIRECT DRIVE BELT DRIVE. Manufactured by UDY Corporation. Cyclone Models Available:

Distributed Temperature Sensing - DTS

Micro Motion 3098 Gas Specific Gravity Meter

MATHESON REFINERY PROGRAM for Specialty Gas Supply. Experience the MATHESON Commitment to Supply Chain Excellence

5. State the function of pulveriser. The pulverisers are the equipments which are used to powdered coal.

The Ambient Air Monitoring System

MPA. Innovation with Integrity. Multi Purpose Analyzer FT-NIR

Qualitative NIR Analysis for Ingredients in the Baking Industry

M I C R O W A V E O P E N V E S S E L D I G E S T I O N S Y S T E M T HE NEW MIL E STO NE MILESTONE

FURNACEPHOSPHORUS AND PHOSPHORICACID PROCESS ECONOMICS PROGRAM. Report No. 52. July A private report by. the

Discover Your Potential

Energy from digester gas. Optimised biogas utilisation

STANDARD CLEANING AND CALIBRATION PROCEDURE FOR TGA-50(H) AND TGA-51(H)

Gas sensors for greenhouse measurements

Name Date Class CHAPTER 1 REVIEW. Answer the following questions in the space provided.

SCION SQ Series GC-MS

Reliability Accuracy Performance

COMPARISON OF PROCESS FLOWS: FLUID BED COMBUSTOR AND GLASSPACK

ATOMIC ABSORTION SPECTROSCOPY: rev. 4/2011 ANALYSIS OF COPPER IN FOOD AND VITAMINS

CHAPTER 7 THE DEHYDRATION AND SWEETENING OF NATURAL GAS

A.17. OXIDIZING PROPERTIES (SOLIDS)

Transcription:

rapid N CUBE

Nitrogen analysis is elementary Nitrogen is one of the building blocks for proteins and therefore our basis for life. The precise nitrogen analysis is of vital importance not only for the determination of raw protein in food and feed but also in connected areas like soil fertility, fertilizers as well as biological and industrial materials. The superior reference method for the total nitrogen determination nowadays is the modified combustion method according to Dumas which is applied in the rapid N cube. Compared to the traditional wet chemical method according to Kjeldahl there are remarkable advantages: Decrease of the analysis time from hours to minutes Completely safe and fully automatic operation Omission of caustic and environment polluting chemicals Low installation requirements and operating costs 100 % nitrogen recovery independent from the type of chemical bond Elementar is the successor of the technology company Heraeus. With its more than 100 years of tradition in CHN analysis it was also the first manufacturer worldwide who made use of the Dumas method for macro samples up to the gram range. The ability to analyze large samples was essential for the use of the Dumas method for routine N/ protein determination of every day samples. The rapid N cube is the product coming from decades of experience. It incorporates modern micro mechanics, electronics and user oriented software. The result is the most compact high performance instrument for the Dumas nitrogen analysis, particularly suitable for cost efficient long term operation with minimum maintenance. The analysis of sulfur is also possible as an option, another key element in biological systems. rapid N 1970 (Heraeus)

The concept is impressively simple The principle of the Dumas method for nitrogen determination is based on the quantitative combustion digestion of the sample at approx. 900 C in excess oxygen. The bound nitrogen is transferred into molecular nitrogen and nitric oxides. The analysis gases are transferred with CO 2 as carrier gas via a catalytic post combustion zone onto a reduction zone. At this point, the conversion of the nitric oxides into nitrogen at hot tungsten takes place. Furthermore, the excess oxygen is bound. After a two stage drying phase, the gas mixture flows to the thermoconductivity detector (TCD) via an electronic flow controller. A connected PC calculates the nitrogen concentration in the sample from the TCD signal of the N 2 in the CO 2 and from the sample weight. The design of the rapid N cube results in a very short flow path, minimal number of valves, moving parts and sealings. This allows for a trouble-free long time operation. The measurement of all the analyte gas, without further sampling or splitting, has several benefits. Errors due to complicated aliquot valves are eliminated, there is no reduction in sensitivity due to a smaller amount of measured analyte, and there is no loss of analyte in the case of slowly combusting samples. The whole gas analysis further serves for automatic optimization of the analysis run and the oxygen consumption. Using CO 2 as carrier gas eliminates the need to absorb the CO 2 generated from the combustion of the sample. For the conversion to sulfur determination, the use of an optional high performance IR detector allows the quick and precise analysis of sulfur as SO 2 in the combustion gas. Since the furnace is already designed for the required 1150 C, only the change from steel to a quartz glass combustion tube is necessary. The clear concept results in simple handling, cost-efficient operation and lowest installation requirements. The maintenance tasks are kept to a minimum. CO2 O2 Drying Combustion CO2 Ref. Detection

The proven further improved Handling of macro samples Up to 1 g solid sample material is wrapped in tin foil or paper and pressed into pellets. For liquids and suspensions, up to 1 ml is filled in tin capsules and sealed gas tight with our optional liquid sampling press. This allows for the analysis of even inhomogeneous samples without extensive grinding or other pre treatment. Even up to 1 g of organic samples can be analyzed! High capacity autosampler The wrapped samples are loaded into a carousel with 0 positions. For samples up to approx. 300 mg weight there is also a carousel with 120 positions available. Reloading during operation is possible at any time. Carousel stacking which interferes with the reliability and inhibits continuous loading while analyzing, is not required. The samples are individually transferred to the combustion tube via the well proven ball valve. A new sealing technology has been employed. The system also incorporates a magnetically controlled shield to protect the ball value during the energetic combustion process. Optimal sample digestion The 3-tube furnace is controllable up to 1200 C and therefore can be used not only for N analysis but also for the analysis of sulfur. The combustion for N analysis is done in the robust stainless steel combustion tube. A large and easy to change crucible collects the ash residues. Catalytic post combustion and reduction both take place in separate and voluminous reactors. Oxygen jet injection directly at the place of combustion serves for a 100 % oxygen dosing to the sample even with strong combustion gas evolution. This results in minimal use of high purity oxygen together with more effective combustion. The patented use of tungsten for the reduction allows 2 to 3 times higher sample capacity in comparison to copper. This results in long uninterrupted operation times. The furnace is designed to use low voltage, providing higher safety and also allows a 10 year furnace warranty. Special attention has been paid to the air flow in the furnace compartment to avoid over heating damage even in the event of loss of cooling fans due to a power failure. Stable gas control and high measuring dynamics When combusting large sample weights, large pressure fluctuations and amounts of humidity may occur. Therefore, the analysis gases are led through an effective 2 stage gas drying and electronic gas flow control directly before the detector. The gas paths are reduced to an absolute minimum and are made of non-corrosive material. The TCD has a large dynamic range for measurements extending from the ppm level to 100 %. The TCD is based on thermistor technology, is impervious to damage from oxygen intrusion, and stands out for particularly high stability and measuring dynamics. Measurements below 20 ppm are possible and instrument calibrations are stable for months and even years.

Measuring automatically correct rapid N cube sets new bench marks For the first time all instrument functions of a Dumas analyzer are digitally controlled and monitored. This results in completely new possibilities of automatic operation, optimization as well as remote control and diagnosis over the internet. The basis for this is the use of the new micro processor generation with 24-bit signal processing as well as electronic sensors for gas flows and pressures. The complete combustion process is monitored and controlled by the system. The operator just has to select the sample type from the methods library. All instrument parameters are then set. Oxygen dosing is controlled via a digital mass flow controller with feedback control based on the detector. This assures complete combustion with the minimal amount of oxygen consumption. The time of analysis is optimized by the system automatically. This results in the shortest time, but also allows for the complete combustion of even slow burning samples. Easy and correct operation by operators of different experience levels is achieved. The design and operation of the Windows based software is a key component of our whole system. Our software is written and developed on our own premises by our own personnel according to strict ISO 9001 requirements. The software allows for a continuous monitoring of real time conditions of the analyzer in both numerical and graphical forms, easy and efficient input of run information with automated functions, cut and paste data to or from Excel, as well as statistical analysis options. The system is designed for intuitive operation, but content sensitive help is just a click away. Automatic optimization of parameters, monitoring of maintenance intervals and service messages, LIMS data transfer are all integrated into the system. Graphical leak checking with pictorial guides for each step is a new favorite feature of users. We also feature our unique browser based pictorial parts list, with drill down operation and exploded component diagrams. Data safety and validity can be assured with the available 21 CFR Part 11 compliant option. A commercial PC or laptop serves as control and evaluation unit which allows the fast change to the latest computer generation.

Protein * Nitrogen * Starch 0.214 ± 0.018 Glutamic acid 9.517 ± 0.021 500 mg 300 mg Soya grist 4.05 ± 0.45 EDTA 9.589 ± 0.004 500 mg 250 mg Flour 12.237 ± 0.012 Inorganic fertilizer, solid 21.104 ± 0.02 9 500 mg 150 mg Malt 9.24 ± 0.030 Soil 0.0215 ± 0.000 9 500 mg 1000 mg Animal feed with fish meal 32.985 ± 0.054 Glue 0.0101 ± 0.000 300 mg 1000 mg Mixed provender 19.85 ± 0.1 4 300 mg Sulfur * Sunflower seeds 22.13 ± 0.31 Sulfanilic acid 18.53 ± 0.09 150 mg Milk powder 3.335 ± 0.012 Flour 0.112 ± 0.0012 1000 mg Emmentaler cheese 28.08 ± 0.34 Soil 0.001 ± 0.0003 500 mg Soya sauce 9.08 ± 0.45 Colza 0.51 ± 0.004 500 mg Saveloy sausage 15.38 ± 0.23 Alfalfa 0.283 ± 0.003 500 mg 1 mg 30 mg 50 mg 30 mg 30 mg * Element concentration in [%], Standard deviation in [%]

Unlimited applications Precise results within minutes All organic and the majority of inorganic samples, liquid or solid, can be analyzed. As a real macro analyzer, the rapid N cube stands out due to the fact that the weight of organic samples may be up to the gram range without incomplete combustion and without forming tar or methane which may lead to false analysis results. This is possible due to the use of a lance injection of the oxygen directly at the place of combustion, a particularly effective catalytic post combustion in a separate tube furnace, as well as the superior control of large combustion gas quantities. This is advantageous e. g. for samples with a high fat content such as oil seeds or meat products. The large sample amount allows the direct analysis also of inhomogeneous samples without extensive pre-treatment. Together with the highly sensitive TCD and the extreme stability of the gas flow, the high sample weight also allows low detection limits of below 20 ppm. This is important e.g. for samples with a very low nitrogen content such as lean soil or starch. For samples with a high mineral content, like soil, the large ash crucible in the combustion tube is of advantage for the uninterrupted number of samples. The emptying of the ash crucible is easy and possible within a few minutes. Where required, the large measuring dynamics makes reliable analytical results possible also for samples of only a few milligrams. The efficient two-stage gas drying allows the serial analysis of aqueous sample material up to 1 ml volume. This applies also for difficult matrices or low concentrations like soy sauce, milk or beer. The correlation of the Dumas analysis results with the Kjeldahl method is officially secured by a number of round robin tests and is the basis of national and international standards. A great advantage is that a large number of applications only require one basic calibration which can be used for months or even years. Only an adjustment of the instrument by 2 3 standard measurements to the instrument status and the atmospheric pressure at the beginning of the measuring day is required. The repeated measurement of calibration standards or blanks within a day and/or within large measuring series is not necessary. The rapid N cube can be easily and quickly modified to the fully automatic analysis of sulfur (option). Soil samples with a concentration of less than 100 ppm, plant material with 0.1 % or even chemicals with up to 100 % sulfur can be determined without problems. For the simultaneous analysis of CNS in macro samples the additional instrument lines vario MAX and vario MACRO of the Elementar portfolio are available.

Complete operating system IR-detector for sulfur analysis Pellet and capsule sealing press

On behalf of your budget rapid N cube is designed for the cost-effective analysis of large sample series Low purchase and installation costs A complete operating system consists of the basic instrument, PC/laptop and a 0.1 mg analytical balance. Approximately 1 m of standard width laboratory bench, power connection (100 V 230 V) and two gases (CO 2, O 2 ) are required for the operation. A hand press for solid samples is included in the initial outfit. A special mechanical pellet press is also available. For liquid samples we recommend our economically priced press with cold weld sealing of the capsules. Provisions like air conditioning, special power lines, exhaust hoods, compressed air or cooling water are not required. Low costs per analysis The reasons for the minimal operational costs are the extremely low oxygen consumption and the long operation times of the employed components. The robust stainless steel combustion tube and the other consumables can be used for a large number of analyses. The analytically superior reduction of all operation gases by the patented use of tungsten instead of copper has further increased the capacity by a factor of 2-3. Compared to the Kjeldahl method there are no additional costs for storage and disposal of chemicals and installations for acid digestion. There are also no time consuming manual steps during operation. High long time stability rapid N cube s design stands out for its minimum of valves, sealings and wires/tubes. The detector and the air condenser are almost maintenance-free. The instrument calibration can be used for months and years and the 3 tube furnace has a 10 years warranty. This results in a very long and trouble-free operation time. Easy and safe operation The analyzer does not require special skills for chemical analysis or the software. The automatic optimization of the operating parameters by the special sensor technology and computing technology makes it possible to also attain correct analytical results with semi-skilled personnel. High safety standards of operation and the omission of toxic or caustic chemicals are also important. Availability also in the future As for all instruments of Elementar, the use of the rapid N cube is supported for more than 10 years. This applies to the availability of spare parts, the support by our worldwide service and the advice of our application specialists.

Specifications rapid N cube Analysis method: Operating modes: Digestion temperatures: in accordance with the safety standards: Combustion method according to Dumas for nitrogen determination. Combustion of the sample, drying, cleaning and reduction of the combustion gases and detection of the nitrogen with a TCD N/protein as standard with TCD Optional S with IR detection 900 C for N determination 1150 C for S determination CE-label, EN 1010 1, EMV low voltage directives 73/23/EEC in accordance with the analysis standards: AOAC 990.03,AOAC 98.0, AOAC 993.13, AOAC 992.15, AOAC 992.23, ASBC, AACC, FGIS, AOCS, CGC (for fertilizer, meat, meat produce, cereals, oil seed, brewing grain, flour, animal feed), DIN/EN/ISO 14891 (milk and milk products), DIN/ISO 13878 (soil), LUFA, MEBAK (brewing), ICC 17 Detection range*: N 0 200 mg (or 100 %) S 0 20 mg (or 100 %) Detection limit*: Standard deviation*: < 20 ppm N < 10 ppm S < 0.05 % abs. (approx. 250 mg glutamic acid) * depending on sample type and analysis mode

Specifications rapid N cube Calibration: Sample weight*: Analysis time*: Multi-point calibration, regression from linear up to 4th order, stable over months or years up to 1 g or 1 ml sample volume approx. 4 min Autosampler: 0 positions in one magazine as standard for samples up to approx. 1 g, optional 120 positions for samples up to approx. 300 mg, reloadable any time during operation Gases: O 2 99.995 % purity, approx. 0.4 l/analysis CO 2 99.995 % purity, approx. 4 l/analysis Instrument control and data processing Operation and control via PC under Windows ; all instrument functions are digitally controllable, the comprehensive operation software includes e.g. automatic leak test, extensive error diagnosis, monitoring of the maintenance cycles, sleep-/wake up function, statistical evaluation and almost unlimited memory capacity for analysis data incl. graphics. Integration in data networks like LIMS and the possibility of remote control and diagnosis via the internet. In full compliance with 21 CFR Part 11 (option). Electrical connections: 100/110/200/230 V, 50/0 Hz, 1,8 kw Dimensions: 42 55 55 cm (W D H) approx. 5 kg * depending on sample kind and analysis mode

rapid N cube is the compact high performance analyzer for the fast and environment-friendly analysis of N/protein according to the Dumas combustion method in macro samples up to 1 g sample weight. In addition the analysis of sulfur is possible. Routine analysis by using most modern technologies for the following application areas: Agriculture and environment Grain, oil seeds, feed, plant material, soil, compost, etc. Food Meat products, milk and dairy products, beer and malt, soy sauce, yeast, etc. Industrial quality control Fertilizers, building materials, starch, glue, pharmaceuticals, etc. Special applications trace sulfur analysis, casting sand, biological-medical nitrogen balance, urine, blood and serum etc.