Application of Structure-Based LC/MS Database Management for Forensic Analysis



Similar documents
GENERAL UNKNOWN SCREENING FOR DRUGS IN BIOLOGICAL SAMPLES BY LC/MS Luc Humbert1, Michel Lhermitte 1, Frederic Grisel 2 1

Micromass LCT User s Guide

Using Natural Products Application Solution with UNIFI for the Identification of Chemical Ingredients of Green Tea Extract

Pesticide Analysis by Mass Spectrometry

Analysis of Polyphenols in Fruit Juices Using ACQUITY UPLC H-Class with UV and MS Detection

Overview. Introduction. AB SCIEX MPX -2 High Throughput TripleTOF 4600 LC/MS/MS System

SCREENING FOR DRUGS IN SERUM AND URINE BY LC/ESI/CID-MS AND MS/MS WITH LIBRARY SEARCHING *

Using NIST Search with Agilent MassHunter Qualitative Analysis Software James Little, Eastman Chemical Company Sept 20, 2012.

Simultaneous qualitative and quantitative analysis using the Agilent 6540 Accurate-Mass Q-TOF

Introduction. What Can an Offline Desktop Processing Tool Provide for a Chemist?

Accurate Mass Screening Workflows for the Analysis of Novel Psychoactive Substances

New drugs of abuse? A case study on Phenazepam & Methoxetamine

Thermo Scientific GC-MS Data Acquisition Instructions for Cerno Bioscience MassWorks Software

CONFIRMATION OF ZOLPIDEM BY LIQUID CHROMATOGRAPHY MASS SPECTROMETRY

Waters Core Chromatography Training (2 Days)

Henry Shion, Robert Birdsall, Steve Cubbedge, and Weibin Chen Waters Corporation, Milford, MA, USA APPLICATION BENEFITS INTRODUCTION WATERS SOLUTIONS

Discovery of Pesticide Protomers Using Routine Ion Mobility Screening

Background Information

Overview. Triple quadrupole (MS/MS) systems provide in comparison to single quadrupole (MS) systems: Introduction

AMD Analysis & Technology AG

Chemical analysis service, Turner s Green Technology Group

Expectations for GC-MS Lab

RAPID MARKER IDENTIFICATION AND CHARACTERISATION OF ESSENTIAL OILS USING A CHEMOMETRIC APROACH

UPLC-MS/MS Analysis of Aldosterone in Plasma for Clinical Research

How To Use An Acquity Qda Detector

UHPLC/MS: An Efficient Tool for Determination of Illicit Drugs

Mass Frontier Version 7.0

ApplicationNOTE Introduction

Hydrophilic-Interaction Chromatography (HILIC) for LC-MS/MS Analysis of Monoamine Neurotransmitters using XBridge BEH Amide XP Columns

STANFORD UNIVERSITY MASS SPECTROMETRY 333 CAMPUS DR., MUDD 175 STANFORD, CA

# LCMS-35 esquire series. Application of LC/APCI Ion Trap Tandem Mass Spectrometry for the Multiresidue Analysis of Pesticides in Water

LC-MS/MS Method for the Determination of Docetaxel in Human Serum for Clinical Research

Unique Software Tools to Enable Quick Screening and Identification of Residues and Contaminants in Food Samples using Accurate Mass LC-MS/MS

Electrospray Ion Trap Mass Spectrometry. Introduction

How To Use Gc-Ms

Application Note # LCMS-92 Interlaboratory Tests Demonstrate the Robustness and Transferability of the Toxtyper Workflow

MEDICINAL CHEMISTRY APPLICATIONS BOOK

Analysis of the Vitamin B Complex in Infant Formula Samples by LC-MS/MS

Enhancing GCMS analysis of trace compounds using a new dynamic baseline compensation algorithm to reduce background interference

How To Build An Amd Quas 3 Ar Mass Spectrometer

LC-MS/MS for Chromatographers

SPE, LC-MS/MS Method for the Determination of Ethinyl Estradiol from Human Plasma

Cliquid Drug Screen & Quant Software for Routine Forensic Toxicology. great interest in forensic, toxicological and clinical research laboratories.

Analysis of Phthalate Esters in Children's Toys Using GC-MS

In-Depth Qualitative Analysis of Complex Proteomic Samples Using High Quality MS/MS at Fast Acquisition Rates

Simultaneous Qualitative and Quantitative Data Acquisition for Research of Diabetes Drugs

Analyzing Small Molecules by EI and GC-MS. July 2014

Analysis of Free Bromate Ions in Tap Water using an ACQUITY UPLC BEH Amide Column

Metabolomics Software Tools. Xiuxia Du, Paul Benton, Stephen Barnes

Application Note # LCMS-81 Introducing New Proteomics Acquisiton Strategies with the compact Towards the Universal Proteomics Acquisition Method

Technical Report. Automatic Identification and Semi-quantitative Analysis of Psychotropic Drugs in Serum Using GC/MS Forensic Toxicological Database

Analysis of Liquid Samples on the Agilent GC-MS

MultiQuant Software Version 3.0 for Accurate Quantification of Clinical Research and Forensic Samples

Appendix 5 Overview of requirements in English

HPLC Analysis of Acetaminophen Tablets with Waters Alliance and Agilent Supplies

Identification of Surfactants by Liquid Chromatography-Mass Spectrometry

Salman Azimi, 1 Nayan S. Mistry, 2 and Michelle Wood 2. Drug Quality Control Laboratory, Supreme Council of Health, Doha, Qatar 2

Sensitive steroid analysis on a new High Speed Triple Quadrupole LC/MS/MS. Mikaël LEVI Shimadzu France

Integrated Data Mining Strategy for Effective Metabolomic Data Analysis

Application of TargetView software within the food industry - the identi cation of pyrazine compounds in potato crisps

Simultaneous Metabolite Identification and Quantitation with UV Data Integration Using LightSight Software Version 2.2

Thermo Scientific SOLA SPE cartridges and plates Technical Guide. Join the revolution. unparalleled performance

Method development for analysis of formaldehyde in foodsimulant. melamine-ware by GC-MS and LC-MS/MS. Internal Technical Report

WATERS QUANTITATIVE ANALYSIS solutions

Determination of Anabolic Steroids in Horse Urine by SPE and LC-MS/MS

GCxGC COUPLED TO FAST SCANNING QUADRUPOLE MS FOR TRACE ANALYSIS OF POPs

Application Note # LCMS-62 Walk-Up Ion Trap Mass Spectrometer System in a Multi-User Environment Using Compass OpenAccess Software

Overview. Purpose. Methods. Results

High Resolution LC-MS Data Output and Analysis

Mass Frontier 7.0 Quick Start Guide

Conversion of a USP Gas Chromatography Method to Convergence Chromatography: Analysis of Atropa Belladonna

Making the Leap to LC/MS/MS: Enhancing and Accelerating Clinical Research and Forensic Toxicology Applications

Alignment and Preprocessing for Data Analysis

Daniel M. Mueller, Katharina M. Rentsch Institut für Klinische Chemie, Universitätsspital Zürich, CH-8091 Zürich, Schweiz

A High Throughput Automated Sample Preparation and Analysis Workflow for Comprehensive Forensic Toxicology Screening using LC/MS/MS

Extraction of Epinephrine, Norepinephrine and Dopamine from Human Plasma Using EVOLUTE EXPRESS WCX Prior to LC-MS/MS Analysis

A Generic LC-MS Method for the Analysis of Multiple of Drug of Abuse Classes with the Thermo Scientific Exactive TM System

Fast, Reproducible LC-MS/MS Analysis of Dextromethorphan and Dextrorphan

MassLynx 4.1 Getting Started Guide

Eleanor Riches Waters Corporation, Manchester, UK INTRODUCTION

AxION edoor. Web-Based, Open-Access Mass Spectrometry Software

A Navigation through the Tracefinder Software Structure and Workflow Options. Frans Schoutsen Pesticide Symposium Prague 27 April 2015

Making the Leap to LC/MS/MS: Enhancing and Accelerating Clinical Research and Forensic Toxicology Applications

Accelerate your Quantitative LC/MS Workflows with a Fully Integrated UHPLC-QQQ Platform

High-Throughput 3-D Chromatography Through Ion Exchange SPE

Increasing Quality While Maintaining Efficiency in Drug Chemistry with DART-TOF MS Screening

How To Test For Contamination In Large Volume Water

High sensitivity assays using online SPE-LC-MS/MS -How low can you go? Mohammed Abrar Unilabs York Bioanalytical solutions, York, UK

XEVO TQ MS PHARMACEUTICAL APPLICATION NOTEBOOK

Thermo Scientific SIEVE Software for Differential Expression Analysis

MassHunter for Agilent GC/MS & GC/MS/MS

The basic division explosives for forensic purposes is shown in Fig. 1

Increasing the Multiplexing of High Resolution Targeted Peptide Quantification Assays

Fast and Automatic Mapping of Disulfide Bonds in a Monoclonal Antibody using SYNAPT G2 HDMS and BiopharmaLynx 1.3

Fast and Accurate Analysis of Vitamin D Metabolites Using Novel Chromatographic Selectivity and Sample Preparation

Analysis of Vegetable Oils by High Performance Liquid Chromatography

Strategies for Developing Optimal Synchronous SIM-Scan Acquisition Methods AutoSIM/Scan Setup and Rapid SIM. Technical Overview.

Transcription:

Cozette M. Cuppett and Michael P. Balogh Waters Corporation, Milford, MA USA Antony Williams, Vitaly Lashin and Ilya Troisky Advanced Chemistry Development, Toronto, ntario, Canada verview Application of LC/UV/MS to the analysis of toxicologically relevant samples Demonstration of several ways in which structural information may assist in sample identification Use of a structure-based data management system for manual interpretation and analysis of sample components Software tools to interpret difficult analysis cases (e.g., high noise backgrounds, manual and automated fragment assignment tools) Introduction In many cases, an automated search method can be used for sample identification owever... Automated search results still must be manually reviewed Difficult or low concentration samples require significant manual interpretation Commercially available databases are only available with nominal mass accuracy Integration of structures with spectral information can provide improved data management and enhance library searching capabilities Particularly useful for manual interpretation and analysis of results Provides structure and substructure search capabilities for data mining Allows management of multiple forms of MS data with a single chemical structure EI, ESI, CI, etc. LC/UV/MS Conditions Chromatography Instrument: Waters 269 Alliance System under MassLynx control Solvents: A: 2, B: MeC 2 l/min 3-4 B in 2 min 35 min total run time 2.1x mm XTerraMS C 18, 3.5 m 35 C column temp PDA Instrument: Waters Model 996 Photodiode Array Detector 21- nm Samples Standards diluted in 3/7 MeC/ 2 Mass Spectrometry Instrument: Waters ZQ under MassLynx control ESI+, centroid Scan -6 amu Scan time:.2 sec Interscan delay:.1 sec Tune page settings Capillary voltage: 3. kv Cone voltage: 3, 5, 7 V Extractor: 6 V RF lens:.1 V Ion energy:.1 LM & M resolution: 14.5 &15. Source temperature: 15 C Desolvation temperature: C Cone gas: 15 l/hr Desolvation gas: 6 l/hr Sample Preparation Procedure for Spiked Samples 3 mg Waters asis LB Cartridge Condition 1 ml Me and 1 ml 2 Load 1 ml spiked serum or anks solution (1:1 dilution of standards with serum or anks ) Wash 1 ml 5 Me in 2 Elute 1 ml Me Evaporate and Reconstitute Room temp in Savant Speed Vac 2 l mobile phase (3 MeC in 2) Benzodiazepines C 3 C 3 - + - + F onazepam 315.411 m/z Diazepam 284.716 m/z Flunitrazepam 313.863 m/z Lorazepam 32.119 m/z C 3 3 C xazepam 286.59 m/z Temazepam.666 m/z Monoisotopic Masses Triazolam 342.439 m/z

Creating UV and MS Libraries Export Data from MassLynx into ACD Export spectrum directly from MassLynx spectrum review window into ACD/ SpecManager MS module Add Spectrum to Database nce the spectrum is imported into ACD/SpecManager, a structure is integrated with the spectra using the integrated drawing package. Thresholding can used to remove low intensity background noise. The ACD spectrum window provides further opportunities to process data From the spectrum window, the data is entered into a searchable database along with the appropriate user data. Creating a UV and MS Database Individual benzodiazepine standards were analyzed under the conditions given previously All MS data (3 cone voltages used to enhance descriptive fragmentation for each compound) were entered into one comprehensive database using the procedure presented below Following a similar procedure, UV data were also incorporated into the database Chemical structures were incorporated into both the UV and MS library entries using the integrated drawing package Ways to search data By spectra By structure By substructure By individual fragment peaks By user-defined text By single DB or multiple DB Manually Searching Data in the Database nce the database is populated, there are several ways in which the data may be accessed and searched. Database Searching Capabilities

Manual Interpretation of Low Concentration Samples Pulling Peaks ut of the oise Little Information Available from s at Low Concentrations 25 pg on column 3 V 2 5 V 14 7 V 19 PDA Using the Map function in MassLynx, it is possible to manually scroll through individual m/z ratios collected during a scan run for each function. Through this functionality, peaks may be picked out that are not evident in the s. For example, with a cone voltage at 7 V, a peak at 193 m/z was found around 16 minutes. -1 2. 4. 6. 8. 1. 12. 14. 16. 18. 2. 22. Time 24. Total ion current chromatograms () produced in the analysis of spiked serum (25 pg of each benzodiazepine on column). Little information is gained from s. By visualizing data with the Map function in MassLynx, it is possible to pick peaks out of the noise. Extraction of idden Peaks 19 154 222 125 132 156 175 228 194 285 23 Extracted Ion Chromatogram 193 m/z Combined Mass Spectrum 193 15 2 417 42 459 295 325 351 25 35 45 516 52 522 554 592 597 5 55 m/z 6 3 2. 4. 6. 8. 1. 12. 14. 16. 18. 2. 22. 24. Time nce individual masses are distinguished from the noise, extracted ion chromatograms can be created and used to generate mass spectra. The mass spectra can then be searched against MS libraries for identification. owever, if the noise is high, extraneous peaks may diminish the utility of automated searches. Ion Searches Ion Search Results The manual selection of peaks and use of relative intensities for searches allows otherwise unmatchable spectra to be found in the database. Manual comparison of the library spectrum from the database and the unknown spectrum is then used to assist in the determination of the identity of the compound. Ion Search Result in Library Ion Search Parameters Unknown Spectrum Match Found in Database In cases where manual interrogation of data is necessary, software that facilitates the process can translate into great time savings. ACD software provides the ability to easily ascertain the relative intensities of all the peaks and perform searches against MS libraries of selected peaks based on their relative intensities. Copyright Waters Corporation 21 Cuppett Relative Intensities Comparison of Unknown Spectrum with Match Found in Library

Using Multi-Spectral Data Export Data from MassLynx into ACD The use of multi-spectral data can provide multiple reference points from which to verify compound identity. This can lead to increased confidence in results. ere we show how multi-spectral data can be used with the structure-based database. PDA and MS Data from MassLynx Benzo_SPE_Serum_25ng_5171_2 596 (1.4) Cm (593:598) 218 4: Diode Array 3.77e4 Benzo_SPE_Serum_25ng_5171_2 667 (1.5) Cm (665:673-(636:648+686:693)) 268 3: Scan ES+ 1.82e7 239 252 31 211 24 212 269 221 227 22 24 26 28 32 34 36 38 nm 22 314 241 238 267 27 249 257 24 26 286 28 287 315 31 325 32 335 346 347 34 359 36 365 377 38 381 394 m/z Data is exported out of MassLynx into ACD/SpecManager. Thresholding is used to remove extraneous background peaks from the MS spectrum. LC/UV/MS run: 25 ng of each benzodiazepine standard on column Searching the Database with Multi-Spectral Data Search Using PDA Data Search Using MS Data Similarity between unknown spectrum and library spectrum umber of library matches PDA matches reflected in List A MS matches reflected in List B Intersect List A and List B to confirm matching hits from the PDA and MS searches 1 overlapping hit from each library: Flunitrazepam at 7 V Autofragmentation The identified MS spectrum may be further evaluated using ACD/SpecManager s Autofragmentation algorithm. Using a proposed structure, the software fragments the molecule and compares the fragments to the spectrum. Percentage of spectrum assigned fragments Copyright Waters Corporation 21 Cuppett Proposed fragment

Summary Structure-based LC/MS database can provide useful tools for the analysis of unknown samples Peak searching for samples containing high background levels against commercial or in-house databases Library searching of both UV and MS spectra; higher degree of confidence when orthogonal results coincide Autofragmentation process assists in the analysis of fragment ions in MS spectra Chemical structure and substructure searching using prior knowledge can provide a means by which to analyze spectra