OFFICER CANIDATE SCHOOL. QAS Project El Dorado Furniture Store 441/Southern Blvd



Similar documents
Get Alarmed, Tennessee! Smoke Alarm Program Saves

SOUTH LYON FIRE DEPARTMENT Manual of Procedures 404

How To Handle An Emergency At A Strata Corporation

ESCAMBIA COUNTY FIRE-RESCUE

Fire Alarm System Plans Review Checklist Property location Date of Review

Educational. Educational-Existing 1/28/2014. OCCUPANT LOADS [no change] Application. Application

FIRE PREVENTION & INVESTIGATION DIVISION 125 Idylwyld Drive South Saskatoon, SK S7M 1L4 Phone: (306) Fax: (306)

CITY OF HOUSTON HIGH-RISE OFFICE BUILDING FIRE SAFETY PLAN

c. As mandated by law, facilities must obtain and maintain valid zoning permits as well as permits for intended use.

Name Of Occupancy Date. Yes No Describe

Get Alarmed, Tennessee! Smoke Alarm Program Saves

MONTH END REPORT. News & Events Tuesday, November 11 th - Tuesday, December 24 th

TOOELE COUNTY EMPLOYEES EMERGENCY SAFETY HANDBOOK 2012 REVISION

Fire Safety Risk Assessment Checklist for Residential Care Premises

Recommended Best Practices For Fire Department Training Programs

Building Code Clarifications - 7. Fire Resistance

Fire Safety Requirements for Child Care Centre

notes Video User s s Guide Accident Involving Radioactive Material

CAL FIRE/San Luis Obispo County Fire Fire Prevention Bureau

FIRE AND LIFE SAFETY REQUIREMENTS FOR CONVENTIONS, TRADE SHOWS AND EXHIBITS

Pollution CO CO 2. Carbonaceo us soot H 2 S, NOX, SO2

Fire Response Plan - Code Red

How To Evacuate The University Of California Building

FACILITY FIRE PREVENTION AND EMERGENCY PREPAREDNESS INSPECTION CHECKLIST

Workplace Fire Safety

Case Study for. The Torch Tower. Dubai Marina. Presented by; Lieutenant Colonel Ali Almutawa Operations Director Dubai Civil Defence

Strategy & Tactics FST 202. COURSE SYLLABUS Strategy & Tactics FST 202 [Semester] CRN 3 Credits

St. John s University Fire Safety Plan

LOUISVILLE FIRE PROTECTION DISTRICT 895 West Via Appia, Louisville, Colorado

Pinole Fire Department

The Story of Mercy and Joplin - Regional EMS Response and Hospital Recovery- Sustainability

East Mississippi Community College. Scooba Campus * Mayhew Campus Department of Public Safety. Campus Emergency Action Plan.

FIRE SAFETY MANUAL. Table of contents can be found on the left side of this document.

AIRCRAFT RESCUE AND FIRE FIGHTING GUIDE REVISION 0. AA Flight Safety Department.4601 Hwy 360; MD 849 GSWFA.Fort Worth Texas Phone

UFF Position Statement: Fire and Smoke as a Weapon

Sam Houston State University

Dennis Fire Department Fire Prevention Mark Dellner Fire Chief

How To Handle An Emergency

NATURAL GAS EMERGENCY PROCEDURES AND ACCIDENT PREVENTION

PURPOSE A confined space is any area or vessel, which meets all three of the following:

North York General Hospital Policy Manual

BUILDING INSPECTORS INSPECTION FORM FOR CHILD CARE CENTERS

Based on the initial size-up and any information available, Command will formulate an action plan to deal with the situation.

NEW SCIENCE FIRE SAFETY ARTICLE INNOVATING FIRE ATTACK TACTICS SUMMER 2013 UL.COM/NEWSCIENCE

St. John s University

Minnesota State Department of Public Safety

Required Certification Documentation. Contractor's installation certification for range hood fire suppression systems.

STATE FIRE MARSHAL'S OFFICE

Hotel Fire Safety for staff

Los Angeles Fire Depart m ent

MARULENG LOCAL MUNICIPALITY

PRE-DESIGNATED DISPATCHING. Presented by The MCCC ROG Committee

Fire Risk Assessment Safety Checklist

How to Register Your Single Family Home for Short-term Rentals

6. GIVE FULL DETAILS OF TYPE OF WORK, OPERATIONS AND ATTACH BROCHURES IF APPLICABLE:

National Transportation Safety Board Washington, D.C

Fire Safety PROCEDURES January 2011

FIRE OFFICER I MANIPULATIVE SKILL OBJECTIVES HUMAN RESOURCE MANAGEMENT

An inventory of hazardous materials used in your workplace will prove useful.

FIREFIGHTER SAFETY. Stay safe during substation fires

Fire Safety Report Fire Protection Management Program and Annual Fire Safety Report on Student Housing

EMERGENCY ACTION, EVACUATION AND FIRE PREVENTION SAFETY PROGRAM

SAN FRANCISCO EMERGENCY INFORMATION. San Francisco Marriott Marquis. 780 Mission St. San Francisco CA T , F ,

FIRE SAFETY ONLINE TRAINING

TAMARAC FIRE RESCUE INSTRUCTIONS FOR FIRE ALARM PRE-SUBMITTAL CHECKLIST

POINT UNIVERSITY CAMPUS SECURITY Emergency Response Plan

SCHOOL FIRE AND LIFE SAFETY INSPECTION CHECKLIST

FIRE SAFETY SELF-INSPECTION FORM FOR CULTURAL INSTITUTIONS

T r a i n i n g T a b l e t

NFPA Edition Fire dampers shall be permitted to be installed in exhaust systems in the following situations:

Incident Management Response Plan Hampton Roads Highway Incident Management Committee

FIRE SAFETY SELF-INSPECTION FORM FOR CULTURAL INSTITUTIONS. 1. All Floors (inspect from top floor to basement): Yes No

NEW YORK CITY FIRE DEPARTMENT

Directions to Students

Implementation Guide for High School Teachers and Guidance Counselors

CONSTRUCTION FIRE SAFETY PLANNING GUIDELINES

FLA S FIRE SAFETY INITIATIVE

Interfacing Elevators with Fire Alarm and Sprinklers

Rapid Intervention Team (RIT)

11/20/2015 THIS DIDN T HAVE TO ABOUT PGFD HAPPEN! 2014 U.S. FIREFIGHTER FATALITY STATISTICS 2014 U.S. FIREFIGHTER FATALITY STATISTICS

Fire Rate Investigation - The Inside Story of an Open Web Truss

U.S. Fire Administration/Technical Report Series Sprinklered Records Storage Facility. Chicago, Illinois. USFA-TR-106/October 1996

Mesa Campus. Annual Fire Safety Report on Student Housing

General Fire Code Requirements Within Commercial Tenant Spaces

Sprinkler and Fire Alarm Systems for the Building Official

FLORIDA ATLANTIC UNIVERSITY FIRE ALARM SYSTEM INSTALLATION MANUAL

Injury Investigation City of Apopka Fire Department Apopka, Florida July 04, 2007

The terms hazard and risk are often used, which we define as the following:

MINIMUM STANDARDS FOR HIGH-RISE BUILDINGS

STANDARD OPERATING PROCEDURES. Rapidly establish triage, treatment and transportation of multiple field casualties.

5.8 Staging Area: The location where incident personnel and equipment are assigned on immediately available status.

PLAN REVIEW GUIDE FOR FIRE ALARM

(Sample) Building Emergency Plan

Surrey Fire & Rescue Service Report of Fire

The Orange County Farmers Museum Emergency Preparedness Plan

WORKPLACE WRITTEN PROCEDURES OH&S Regulation, Section 3

PRINCE GEORGE S COUNTY, MARYLAND FIRE/EMERGENCY MEDICAL SERVICES DEPARTMENT GENERAL ORDER

Original Document 10/16/07 Revised 01/30/09 2 nd Revision rd Revision- 12/18/14

2015 Annual Fire Safety Report

Transcription:

OFFICER CANIDATE SCHOOL QAS Project El Dorado Furniture Store 441/Southern Blvd

Presenters John Flaherty Operational Lt Trevor Harris Operational Lt Donald Corbitt Operational Lt Lawrence Wolfe Operational Lt

Topics Buildings History, Special Considerations Store Construction,QAS Fixed Fire Protection, Water Supply Hazards Dispatch Protocol and Fill Strategies and Tactics

Buildings History and Special Considerations Remodeled in 2006/2007 Easy Egress off of 441 or Southern Blvd Store Hours Monday-Saturday 10:00am-9:00 pm Sunday-11:00am 11:00am-6:00 pm No night security, inside store.

Store Construction 1 Story, CBS Construction, Approximately 20,000square feet. Non Combustible Construction. Corrugated Metal Roof Construction with Metal Bar Joyce Support. 1 Interior Ladder to the Roof. Side B,C,D has no windows.

Side A

Side B

Side C

Side D

Pull Stations,Smoke Detector, Duct Detector,Heat Detector,Flow Switch,Tamper Switch

Fire Control Panel

Fire Dept Connections Side C

OS & Y Side C

Hazards: Building broken down into multiple compartments, potential for Entrapment.

Hazards: Heavy Fire Load

Other Hazards: Occupants change throughout day. Potential for falling furniture in stock area. Potential Carcinogenics materials that can burn.

Dispatch Protocol and Fill 11C Commercial Structure Fire: 3E 1R or 1RP 1DC 1 EM 1 Aerial 11C Commercial Structure Fire: Fill Alarm 1E 1R or 1 RP 1EM 1DC 1BC 1L

The Incident At 18:00 hrs DC2,Q29,E-34,R 34,R-34, EMS2 E28,E-25 25 were dispatched to a Commercial Structure Fire at Southern Blvd and State Rd 7. Winds blowing out of the East at 15 mph 80 degrees F.

Upon Arrival of E34------ ------Size-Up 1 st arriving engine should, if applicable do a 360 to give a thorough arrival report.

Conditions Arrival Report Conditions--- ---E-34 arrival Side Charlie/Delta side of a Commercial structure Approximately 20,000 Sq Ft. Non- combustible construction type. We have heavy smoke coming from side D Delta.

Side D

Action E-34 will pass Command and start evacuating with a Par of Two through Side A/Alpha. E-34 Driver will catch a Secured Water Supply hydrant at Side D and hook up to a F/D connection on side C if needed to boost the sprinkler system.

Needs Fill the Alarm with a Commercial Response. Make sure PD is responding reference crowd control. Advise incoming units that there is a Water Supply and FDC on the C/D side of Structure.

Command DC2 arrives and establishes El-Dorada Command. Command post is at A/D corner. And advises dispatch were at level Two Accountability. Leaves side A open for Q-29Q And sets up Level two Staging in N/E corner of parking lot, out of the way.

R34 Arrives Tactic/Rescue---- ----Help E34 with evacuation.

DC2 starts Command Sequence Incident Priorities Size Up Incident Objectives Strategies Tactical Operations Progress Reports

Level Two Staging

More Resources IC should advise the Staging Officer to have at least two extra Engines two extra Rescues and Two BLS units always in staging. Should also call in Power Co, PD, and Fire Investigator

EMS2 Arrives Tactic/Safety Officer---- Does a 360 and reports back to Command.

Incident Objectives Making sure Evacuating is being done. Ventilating for life Extinguishment Exposures

Rescue-- --E34,R34 Ventilation -- Q29 Extinguish-- --E28 Exposures-- --E21 Strategies

Q-29 Arrives Arrives side A/Alpha and Awaits for Assignment. Tactics/Ventilation---- ----Opening up receiving doors on side D/Delta for Ventilation, for life then fire.

E-28 Arrival Tactic/Extinguish--- ---Blitz line, through side D/Delta. Big water,and use 3 supply line if needed for extra length.

Engine 21 Tactic/Exposure----- -----Side A/B catching a Hydrant on A/B side and using Deck Gun Mounted on Engine.

E-25 Arrival and assignment RIC

Fill Assignments EMS3-- Staging Officer DC3-- --Stage BC2-- --IC Aide E21-- --Exposure RP30-- --Rehab

Progress Reports IC starts requesting progress reports between10-15 15 minutes.

E34 AND R34 progress report Advise Evacuation is done and all-clear is called. The units exited the building Side A calling APARS.

Q29 Progress Report After opening the receiving doors, visibility was very good, and E-28 E was able to get to the seat of the fire.q29 left side D with a Par of three. Reported to Rehab.

E28 Progress Report Advises they found the seat of the fire, there were some mattresses that were on fire, and that fire is under control and they were now looking for extension.

E21 Progress Report They advised that they caught the hydrant and was ready for Exposure if needed.

Staging Officer Was advised from Command to start releasing Units.

Safety Progress Report No new hazards, Incident was deescalating.

E28 Progress Report No extension of fire was found. Tic was used E28 exited structure from side D with a Par of Three. Report to Rehab

E21 Progress Report Was advised to breakdown. And report to Rehab.

Secondary Search Was done by Q29,all clear was called.

Salvage and Overhaul Was done with caution and was meticulous, due to the merchandise of building. Salvage covers were used for not only covering furniture, but for walkways and to channel water waste.

IC checks in with Rehab No injuries reported All involved went through Rehab Rehab was shutdown

Termination All equipment on units accounted. Command Staff had meeting. Then informal PIA was done. IC turned scene over to Fire Investigator. Command terminated All units went back in service.

Any questions? In Conclusion

Thank You And remember SLOW DOWN. Remember those Veteran Drivers, and Fire Fighters are great assets. Everyone goes home.