Residential and Commercial Water Systems Goulds Pumps AquaBoost II Variable Speed Constant Pressure Systems * Available up to 1 GPM systems Features The AquaBoost II variable speed pump controller and complete booster package kits, provide an economical answer for municipal water district customers with low water pressure. Both domestic and light commercial applications can benefit. As water use increases, the AquaBoost II changes pump speed to maintain pressure. Large supply tanks are eliminated and less wear and tear on your pump and motor. Think of it as Cruise Control for your pump! The AquaBoost II is available with a range of flow rates to handle homes with up to four baths, irrigation, filtration and fire suppression systems. Light commercial applications up to 1 GPM at 45 PSI boost. The AquaBoost II is available as either a separate controller or as part of a complete pump package with everything you need to plumb it to a domestic water line. C U L US + The AquaBoost Advantage + Goulds Pumps is a brand of ITT Corporation. Pressure Pressure www.goulds.com Engineered for life Flow + Typical home water pressure drops when demand is high. Flow + The AquaBoost makes up the pressure difference at peak demand for constant home water pressure.
COMPONENTS *1AB2 4.2 Amp, 28-23 V, single phase input, 1 HP AquaBoost II variable speed controller, wall mount set, transducer, pre-wired. (Pump and tank not included.) *1AB2LB135 1 HP AquaBoost II controller, wall mount set, LB stainless steel jet pump, transducer, V6P tank, pressure gauge, discharge tee. Controller is pre-wired to the pump. Flows to 15 GPM. 2AB2 6.9 Amp, 28-23 V, single phase input, 2 HP AquaBoost II variable speed controller, wall mount set, transducer, pre-wired. (Pump and tank not included.) 2AB21MC1F2B2 2 HP AquaBoost II controller, wall mount set, MCC cast iron / stainless steel pump, transducer, V6P (2 gal.) tank and pressure gauge. Controller is pre-wired. Flows to 27 GPM. 2AB21MC1G2A2 2 HP AquaBoost II controller, wall mount kit, MCC cast iron / stainless steel pump, transducer, V6P (2 gal.) tank and pressure gauge. Controller is pre-wired. Flows to 32 GPM. CAUTION AquaBoost System CANNOT be set above 8 psi, for the total discharge pressure (suction plus discharge). *1AB21HM1E2D 1 HP AquaBoost II controller, wall mount kit, HMS stainless steel pump, transducer, V6P (2 gal.) tank and discharge pipe tee. Controller is pre-wired. Flows to 2 GPM. *1AB22HM1E2D 1 HP AquaBoost II controller, wall mount kit, HMS stainless steel pump, transducer, V6P (2 gal.) tank, pressure gauge and discharge pipe tee. Controller is pre-wired. Flows to 3 GPM. 2AB22HM1F2E 2 HP AquaBoost II controller, wall mount kit, HMS stainless steel pump, transducer, V6P (2 gal.) tank, pressure gauge and discharge pipe tee. Controller is pre-wired. Flows to 3 GPM. 3AB2LCB1H2 3 HP AquaBoost II controller, wall mount kit, LCB stainless steel pump, transducer, V6P (2 gal.) tank, pressure gauge and discharge pipe tee. Controller is pre-wired. Flows to 5 GPM. 2AB22MC1G2D2 2 HP AquaBoost II controller, wall mount kit, MCC cast iron/stainless steel impeller pump, pressure transducer, V6P (2 gal.) tank, pressure gauge, 1¼" bronze discharge tank tee. Controller and motor are pre-wired. Flows to 8 GPM. 2AB22HM1F2E 3 HP AquaBoost II controller, wall mount kit, LCB multi-stage stainless steel pump, pressure transducer, V6P tank, pressure gauge, 1" bronze discharge tank tee. Controller and pump motor are pre-wired. Flows to 5 GPM. **5AB22MC1J2K2 5 HP AquaBoost II controller, wall mount, MCC cast iron/stainless impeller pump, pressure transducer, pressure gauge, 1¼" bronze tank tee, controller and motor are pre-wired. Flows to 1 GPM. **5AB2LCC1J2D 5 HP AquaBoost II controller, wall mount, LCC stainless steel pump, pressure transducer, pressure gauge, 1¼" bronze tank tee, controller and motor are pre-wired. Flows to 7 GPM. * 1 HP available in 115 volt models. ** Tank not included. 2
AquaBoost II System Selection PSI 2-1 2 3 4 5 6 7 8 9 1 BOOST GPM GPM GPM GPM GPM GPM GPM GPM GPM GPM 2 1 3 3 5 5 9 9 9 1 1 25 1 3 3 6 9 9 9 1 1 1 3 1 3 3 6 9 1 1 1 1 1 35 1 3 3 6 6 1 1 1 1 1 4 1 3 3 6 7 1 1 1 1 1 45 1 3 3 6 8 1 1 1 1 1 5 1 3 4 7 8 1 1 1 1 55 1 3 4 7 8 1 1 6 1 4 7 8 8 65 2 4 7 8 8 7 2 4 8 8 75 4 4 8 8 4 *1 1AB2LB135 (1 HP, stainless steel pump, 1" discharge, 1¼" suction) *2 1AB21HM1E2D (1 HP, stainless steel pump, 1" discharge, 1¼" suction) *3 1AB22HM1E2D (1 HP, stainless steel pump, 1" discharge, 1¼" suction) 4 2AB22HM1F2E (1½ HP, stainless steel pump, 1" discharge, 1¼" suction) 5 2AB21MC1F2B2 (1½ HP, cast iron pump, 1" discharge, 1¼" suction) 6 2AB21MC1G2A2 (2 HP, cast iron pump, 1" discharge, 1¼" suction) 7 3AB2LCB1H2D (3 HP, stainless steel pump, 1" discharge, 1¼" suction) 8 5AB2LCC1J2D (5 HP, stainless steel pump, 1" discharge, 1½" suction) 9 2AB22MC1G2D2 (2 HP, cast iron pump, 1¼" discharge, 1½" suction) 1 5AB22MC1J2K2 (5 HP, cast iron pump, 1¼" discharge, 1½" suction) * 1 HP available in 115 volt input models. See Price Pages. Items # 8 and #1 do not include tank. Recommend at least 13 gallon volume bladder tank. NOTE: PSI is boosting pressure, NOT total system pressure. 3
AQUABOOST CONTROLLER FEATURES Input Power* 28-23V ±15%, single phase (controller only) Output Power Up to 23V three phase (based on input voltage). Motor rated for 28-23V, ±1%. Maximum Output Current 4.2 amps 1AB2 (1 HP) 6.9 amps 2AB2 (2 HP) Input Controls Up and down buttons to set pressure. Signal Lights Power on, pump running, inverter stopped, pump stopped, standby, faults/errors. Electrical Efficiency Over 95% at full load Protection Against Short circuit, under voltage, overload, motor temperature, dead heading, run out, suction loss, sensor fault, bound pump, over voltage, static discharge. Note: Suction loss/run out is set for minimum 1 psi at discharge! Ambient Temperature 34º F to 14º F Maximum Humidity 95% at 14º F, non-condensing Air Pollution Avoid mounting in areas with excessive dust, acids, corrosives and salts. Approvals U C L US Controller Enclosure Outdoor, NEMA 3R, IP 43 (Rain-tight) Mounting Wall mount with mounting hardware. Cooling Convection with cast aluminum heat sink. 3 HP, 5 HP with temp. fan. Transducer.5-4.5 VDC with 5 VDC power supply, 1 psi range, 8-inch 3-wire shielded cable. Input Wire 5 feet of 14, 1 or 8 gauge cable. Depending on size, cable is pre-wired to controller and motor conduit box. Output Wire 1 feet of 14 gauge cable. Cable is prewired to controller and pump motor (when provided). *Low input voltage may affect motor operation. 4 1AB2 2AB2 (8.38).33 (99.6) 3.9 (242.4) 9.53 (157.9) 6.22 (232.56) 9.16 (259.8) 1.2 (57.15) 2.25 (12.7).48 (114.3) 4.5 PRESSURE RANGE Nominal Range Field adjustable from 2-8 psi, total system pressure. WarNING DO NOT SET REQUIRED SYSTEM PRESSURE ABOVE 8 PSI. SEVERE DAMAGE TO PLUMBING COULD RESULT. PLUMB RELIEF VALVE OUTSIDE OR DRAIN. 1 2 Liquid Tight (81.28) 3.2 (237.6) 9.33 (135.36) 5.33 (16.51).65
Suggested AquaBoost Installation for MUNICIPAL Water SYSTEM Home supply Water Main Check Valves Disconnect Circuit Breaker AquaBoost Control Isolation Valve Unions Tank Gauge Relief Valve Check Valves Figure 1 To Drain Suggested AquaBoost Installation for Well Pump SYSTEM Home supply Well supply Check Valves Disconnect Circuit Breaker AquaBoost Control Isolation Valve Unions atmospheric storage tank Tank Gauge Relief Valve Check Valves Figure 2 To Drain 5
METERS Model MCC / 1MC size 1 x 1 1 4-6 1MC1F2B, 1MC1G2A VARIABLE SPEED FEET Performance Range at Suction, Max. Imp. Dia. 6 1 8 15 4 14 13 12 11 1MC1G2A 1MC1F2B MAX (6 1 8 ) TOTAL DYNAMIC HEAD H 3 2 1 9 8 7 6 5 1 4 3 2 1 MIN Indicates 1MC1F2B pump with 5 3 4 diameter impeller. 5 1 15 2 25 3 U.S. GPM 1 2 3 4 5 6 7 CAPACITY m 3 hr METERS 5 PSI 8 7 FEET 18 16 MODeL LB / size 1 x 1 1 4 LB135 VARIABLE SPEED Performance Range at Suction Impeller Diameter 5 1 4 TOTAL DYNAMIC HEAD (H) 4 3 6 5 4 14 12 1 8 MAX 2 1 3 2 1 6 4 MIN 2 2 4 6 8 1 12 14 16 18 2 22 U.S. GPM NOTE: Operation beyond pictured range, may overload controller and cause shutdown. 1 2 3 4 5 CAPACITY (Q) 6 m 3 hr
METERS 9 8 TOTAL DYNAMIC HEAD 7 6 5 4 3 PSI 1 9 8 7 6 5 4 FEET 3 25 2 15 1 1HMS 2HMS 1HM1E2D, 2HM1E2D and 2HM1F2E Performance Range at Suction MAXIMUM SPEED 6 4 2 EFF. % 2 1 3 2 1 5 5 1 15 2 25 3 35 4 US GPM 1 2 3 4 5 6 7 8 9 m 3 /hr 1 CAPACITY 1 Curve represents pump model 1HM1E2D. ➁ Curve represents pump model 2HM1E2DO. ➂ Curve represents pump model 2HM1F2E. 7
TOTAL DYNAMIC HEAD (TDH) FEET 21 2 19 18 17 16 15 14 13 12 11 1 9 8 7 6 5 4 3 2 1 355 RPM 315 2625 1775 52.2% EFF. LC Stainless Steel Variable Speed Constant Pressure System MODEL: 3AB2LCB1H2D 2 STAGE PUMP 5.19" DIAM. IMP. 4 8 12 16 2 24 28 32 36 4 44 48 62 56 6 US GPM CAPACITY TOTAL DYNAMIC HEAD (TDH) FEET 92 88 84 8 76 72 68 64 6 56 52 48 44 4 36 32 28 24 2 16 12 8 4 355 RPM 315 2625 1775 6.4% MCC Stainless Steel Variable Speed Constant Pressure System MODEL: 2AB22MC1G2D2 2 STAGE PUMP 4.62" DIAM. IMP. EFF. 5 1 15 2 25 3 35 4 45 5 55 6 65 7 75 8 85 9 95 1 15 11 115 CAPACITY US GPM NOTE: Curves indicate boost pressure. 8
TOTAL DYNAMIC HEAD (TDH) FEET 14 13 12 11 1 9 8 7 6 5 4 3 2 1 355 RPM 315 2625 1775 MCC Cast Iron Variable Speed Constant Pressure System MODEL: 5AB22MC1J2K2 2 STAGE PUMP 6.12" DIAM. IMP. 59.3% EFF. 1 2 3 4 5 6 7 8 9 1 11 12 CAPACITY 13 US GPM HEAD FEET 21 2 19 18 17 16 15 14 13 12 11 1 9 8 7 6 5 4 3 2 1 355 RPM 315 2625 1775 52.7% EFF. LC Stainless Steel Variable Speed Constant Pressure System MODEL: 5AB2LCC1J2D 2 STAGE PUMP 5.19" DIAM. IMP. 5 1 15 2 25 3 35 4 45 5 55 6 65 7 75 8 85 9 95 1 CAPACITY US GPM NOTE: Curves indicate boost pressure. 9
DIMENSIONS LB PUMP (LB135) WITH TANK AND TEE Capacities to 15 GPM Pipe Connections 1 x 1 1 4 NPT Rotation Right hand clockwise, viewed Maximum Temperature of Water 12º F from motor end NOTE: Tank Liquid Temperature Limit is 12º F Pump Liquid Temperature Limit is 14º F Materials 34 stainless steel casing Noryl impeller Maximum System Working Pressure 85 psi Motor 1 HP, ODP, Three Phase, Seal Carbon / Silicon Carbide / EPR 28-23/46V Overload protection, starters, heaters not required. Dimensions are in inches. 1 2 NPT PLUG 2.78 14.93 PRESSURE GAUGE PORT 1 4 NPT V6P TANK 3 4 NPT TRANSDUCER PORT 1 4 NPT DISCHARGE 1 NPT MALE 3 4 NPT FEMALE SUCTION 1 1 4 NPT FEMALE 18.43 14.31 1 2-14 NPSM CONDUIT CONNECTION ODP MOTORS 8.75 6.31fl 4.25 REF 6.5 6.75 8.9 1..1 (12 GA) 7. Approximate Packaged Shipping Weight 55 lbs. 1
DIMENSIONS MCC PUMP (1MC1G2A2 and 1MC1F2B2) WITH TANK AND TEE Capacity to 32 GPM (1MC1G2A2) to 27 GPM (1MC1F2B2) Rotation Right hand clockwise, viewed from motor end Materials Cast iron casing 316 stainless steel impeller Pipe Connections 1 x 1 1 4 NPT Maximum Temperature of Water 12º F NOTE: Tank Liquid Temperature Limit is 12º F Pump Liquid Temperature Limit is 212º F Maximum System Working Pressure 85 psi Motor 1 1 2 HP, ODP, Three Phase, Seal Carbon / Silicon Carbide / EPR 28-23/46V 2 HP, ODP, Three Phase, 28-23/46V Overload protection, starters, heaters not required. Dimensions are in inches. 1 2 NPT PLUG 2. PRESSURE GAUGE PORT 1 4 NPT V6P TANK 3 4 NPT TRANSDUCER PORT 1 4 NPT 6.25 DISCHARGE 1 NPT MALE 3 4 NPT FEMALE 19.87 SUCTION 1 1 4 NPT FEMALE 15.75 12.22 1 2-14 NPSM CONDUIT CONNECTION ODP MOTORS 6.31fl 4.5 6.75 1 4 NPT DRAIN PLUG.75.1 (12 GA) 4.58 6.75 4 SLOTS LENGTHWISE.34 X.5 LONG Approximate Packaged Shipping Weight 75 lbs. 11
DIMENSIONS HMS PUMPS (1HM1E2D, 2HM1E2D) Capacities to 2 GPM (1HM) Pipe Connections 1 x 1 1 4 NPT to 38 GPM (2HM4/2HM5) Maximum Temperature of Water 12º F Rotation Right hand clockwise, viewed NOTE: Tank Liquid Temperature Limit is 12º F from motor end Pump Liquid Temperature Limit is 212º F Materials 316L stainless steel for all liquid Maximum System Working Pressure 85 psi handling components Seal Carbon / Silicon Carbide / EPR Motor 1 HP, ODP, Three Phase,28-23/46V (1HM/2HM4) 1.5 HP, ODP, Three Phase,28-23/46V (2HMS5) Overload protection, starters, heaters not required. Dimensions are in inches. TRANSDUCER PORT 1/4 NPT 1/2 NPT PLUG A 3.19 PRESSURE GAUGE PORT 1/4 NPT C V6P TANK 3/4 NPT 1 NPT 16.75 MAX 12.12 ±.5 2.19 DISCHARGE 1 NPT MALE 3/4 NPT FEMALE FILL PLUG 6.53 MAX 4.12 4.94 5.5 6.75 1 1 4 NPT SUCTION DRAIN PLUG L 4.94 1/2-14 NPSM CONDUIT CONNECTION ODP MOTORS 7.25 4 SLOTS LENGTHWISE.34 X.72 ON CENTER AQUABOOST A L C MOUNTING 1AB22HM1E2D 5.75 1.75 11.62 View B 1AB21HM1E2D 5.75 1.75 11.12 View A 2AB22HM1F2E 6.73 11.75 11.62 View B 12 Approximate Packaged Shipping Weight 55 lbs.
ALTERNATE PUMP MODELS FOR USE WITH 1AB2 CONTROLLER MCC 1 2, 3 4, 1 HP, 3 ph, ODP or TEFC motor versions Note: These pumps are 3642 1 3, 1 2, 1 HP, 3 ph, ODP or TEFC motor versions not currently offered as GT73, GT13 3 ph, ODP or TEFC motor versions a packaged kit, from Goulds Pumps. HSC7, HSC1 3 ph, ODP or TEFC motor versions HMS 1 2, 3 4, 1 HP, 3 ph, ODP or TEFC motor versions All units require three phase motors. 5GB, 7GB 1 2, 3 4, 1 HP, 3 ph, ODP or TEFC motor versions NPE 1 2, 3 4, 1 HP, 3 ph, ODP or TEFC motor versions Size pumps and controllers according NPO 1 2, 3 4, 1 HP, 3 ph, ODP or TEFC motor versions to service factor MCS 1 2, 3 4, 1 HP, 3 ph, ODP or TEFC motor versions amps of the motor. ICS 1 2, 3 4, 1 HP, 3 ph, ODP or TEFC motor versions LB 1 2 and 3 4 HP, 3 ph, ODP or TEFC motor versions Submersible Pumps Additional, external load filters and programming required. Consult factory. ALTERNATE PUMP MODELS FOR USE WITH 2AB2 CONTROLLER 3642 1 1 2, 2 HP, 3 ph, ODP or TEFC motor versions GT 1 1 2, 2 HP, 3 ph, ODP or TEFC motor versions HSC 1 1 2, 2 HP, 3 ph, ODP or TEFC motor versions HMS 1 1 2 HP, 3 ph, ODP or TEFC motor versions 1GB 1 1 2, 2 HP, 3 ph, ODP or TEFC motor versions NPE 1 1 2, 2 HP, 3 ph, ODP or TEFC motor versions NPO 1 1 2, 2 HP, 3 ph, ODP or TEFC motor versions MCS 1 1 2, 2 HP, 3 ph, ODP or TEFC motor versions ICS 1 1 2, 2 HP, 3 ph, ODP or TEFC motor versions Note: These pumps are not currently offered as a packaged kit, from Goulds Pumps. All units require three phase motors. Size pumps and controllers according to service factor amps of the motor. 13
PACKAGED HARDWARE WITHOUT PUMP AND MOTOR (SEE PRICING PAGE) Part Number 15K4 KIT INCLUDES: 1) Tank V6P (2 gal.) 2) 1" Bronze Discharge Tee AV 2-6 3) Pipe Plug 1 2", 6K68 4) Pressure Gauge AG5 (1 1 PSI) 14
NOTES 15
Residential and Commercial Water Systems Goulds Pumps, AquaBoost and the ITT Engineered Blocks Symbol are registered trademarks and tradenames of ITT Corporation. SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE. BAQUABII January, 28 28 ITT Corporation Engineered for life