SECTION DECORATIVE METAL RAILINGS Architectural Railing System - Dot

Similar documents
Sapa: SECTION ARCHITECTURAL ALUMINUM HANDRAILS AND RAILINGS

SECTION ALUMINUM HANDRAIL AND RAILING SYSTEMS WITH DECORATIVE METAL PANEL INFILLS

SECTION COILING COUNTER DOORS. Display hidden notes to specifier. (Don't know how? Click Here)

ATI Evaluation Service A Division of Architectural Testing Certification Services

CLEAR-DIVISIONS CENTERFOLD

SECTION SECTIONAL OVERHEAD DOORS 521 SERIES ALUMINUM SECTIONAL OVERHEAD DOORS

CLEAR-DIVISIONS APERTO

SECTION STANDING SEAM METAL ROOFING

CLEAR-DIVISIONS VARIOFOLD

PART 1 GENERAL 1.1 SECTION INCLUDES

SECTION WINDOW WASHING SYSTEMS

JANUARY, 2016 TR-7100 Windows (Fixed) 1 EC ALUMINUM WINDOWS Guide Specs

SECTION ALUMINUM FRAMED ENTRANCES and STOREFRONTS. System 402 Flush-Glazed Screw Spline Storefront

CONTENTS 1. INTRODUCTION METHODOLOGY RESULTS & FINDINGS...9 APPENDIX

Simplified Steel Stair Design for Commercial and Institutional Buildings

1.02 SYSTEM DESCRIPTION

Section METAL STAIRS

DIVISION 8, METAL SOUND CONTROL DOOR ASSEMBLIES PART 1 GENERAL 1.1 RELATED DOCUMENTS

3-Part Specification Railing Cable Systems

SECTION GUARDA SECURITY WINDOW SCREENS

Display hidden notes to specifier. (Don't know how? Click Here) A. Advanced Upcoiling Security Grilles, power operated.

Holiday Inn Express & Suites Covington (Newton County) 1. Standing-seam metal roofing, custom fabricated.

1. Preassembled steel stairs with concrete-filled treads. 2. Handrails attached to walls adjacent to metal stairs.

SECTION METAL WALL PANELS

OGi Architectural Metal Solutions

FF+E Package 1: Casegoods Specifications UCSD NORTH CAMPUS HOUSING, PHASE 1

Drexel Metals Inc. DMC 100SS 16oz min. Copper Mechanical Seam Metal Roof System over Plywood

SECTION PREFORMED METAL STANDING SEAM ROOFING

Specifications. Preformed Metal Wall and Roof Panels. Alcoa Cladding Systems Manufacturing Plant 100 Industrial Boulevard Eastman, Georgia 31023

glass & Glazing Products

SECTION VINYL WINDOWS. A. The General Conditions, Supplementary Conditions, and Division 01 - Requirements apply.

SECTION EXPANSION CONTROL

Design of Commercial/Industrial Guardrail Systems for Fall Protection

STANDARD SPECIFICATIONS SECTION METAL FABRICATIONS

SECTION [ ] [08973] GLASS CANOPIES

DENVER MODEL 30 X 30 SPECIFICATIONS

2. Division 05 Structural Steel Framing for steel framework requirements

Fixed Access Ladders. Table of Contents. 1. Legislative Requirements

Phoenix-3W Series One-Way Security Revolving Doors

SECTION 6. Glass Storefront Doors:

TEST REPORT. Rendered to: INTEX MILLWORK SOLUTIONS, LLC. For: Rigid Cellular PVC Guardrail System Hampton RS40

SECTION VIBRATION AND SEISMIC CONTROLS FOR ELECTRICAL SYSTEMS

SECTION CEMENT-MORTAR LINED AND COATED STEEL PIPE

SECTION PREFORMED METAL STANDING SEAM ROOFING PART 1 - GENERAL 1.1 DESCRIPTION OF WORK

Scottsdale, Arizona. Presentation by: Hermes Norero, P.E. President and CEO

City of San Diego, CWP Guidelines

Preformed Metal Roofing and Siding

SECTION SERIES 1500 VINYL PATIO DOORS

SECTION STANDING SEAM METAL ROOF

09/07/07 GLASSFIBER REINFORCED CEMENT (GRC) C. S. I. Spec Master Spec Page 1

SECTION HANGERS AND SUPPORTS FOR HVAC PIPING AND EQUIPMENT

SECTION STORAGE SHELVING. Copyright ARCAT, Inc. - All rights reserved

TARIFF CODE and updates standard

General (1) This Section applies to the design and construction of interior and exterior stairs, steps, ramps, railings and guards.

MEZZANINE SPECIFICATIONS PART 1 GENERAL 1.1 SCOPE 1.2 APPROVED MANUFACTURER 1.3 REGULATORY ORGANIZATIONS AND GROUPS 1.4 QUALITY ASSURANCE

LOADING DOCK EQUIPMENT. A. Section Concrete Forms and Accessories: Placement of anchors into concrete.

UNIVERSITY OF WASHINGTON Facilities Services Design Guide. Architectural. Roofing. Basis of Design

MOCK-UP TEST REPORT. Rendered to: TUBELITE, INC. PROJECT: 200 Series Curtain Wall Mock-Up

SECTION CHAIN LINK FENCES AND GATES

Ref: GA13UK Glass Awning Support System

ENGINEERING SPECIFICATION PULTRUDED DYNARAIL FIBERGLASS LADDER & LADDER CAGES

Architectural Casework Description of Work

STANDARD FOR NON-FIRE RATED ROLLING DOORS

Sports and High Mast Lighting Poles Phone: (866) Fax: (817)

ESR-1190 Reissued December 1, 2009 This report is subject to re-examination in two years.

Wisconsin Building Products Evaluation

SCENIC VIEW SV 10 SECTION SOLAR CONTROL FILMS

BLADDER SURGE CONTROL SYSTEM

SECTION CABLE TRAYS. A. Continuous, rigid, welded steel or stainless steel wire mesh cable management system.

ADDENDUM #1(BID PACKAGE # 3)

DESIGN CLARIFICATION (DC)

Toll Free:

B. Related Sections: 1. Section Raceway and Boxes for Electrical Systems.

SECTION 1 GENERAL REQUIREMENTS

SPECIFICATIONS FOR BOON EDAM TOMSED MODEL TUT-65TMB

SECTION WARDROBE AND CLOSET SPECIALTIES PART 1 - GENERAL

The replacement or modification of existing windows shall comply with the following requirements:

COLORADO MODEL. 35 x 65 SPECIFICATIONS

CONTRACT SPECIFICATIONS - SEISMIC ISOLATION BEARINGS

UNIVERSAL RAILING, STEEL

SECTION GUARDRAILS

Valu Guide Sheaths. Valu Guide Inserts. Optional Valu Guide Inserts. Typical Properties of Valu Guide Rail. and Hardware.

CHAPTER 7: Building Systems ROOFING SYSTEMS

Pre-Cut Sauna Specifications

STANDING SEAM SHEET METAL ROOFING

Discipline: Structural Issued

SECTION STANDING SEAM METAL ROOFING

Stainless Steel Perimeter Recirculation Systems Engineered supply and return systems for swimming pools, water features and aquatic facilities.

SECTION GROUND WATER STORAGE TANKS

12.1 Schlüter -KERDI-BOARD

SECTION COLD-FORMED METAL DECK FRAMING Elevations Steel Deck Framing by Trex

SECTION FREIGHT & PARKING GARAGE ELEVATORS PART I - GENERAL

SECTION SANITARY SEWER AND STORM DRAIN SYSTEMS

RadianceRail Installation Guide

Residential Deck Safety, Construction, and Repair

Pigeon Spike Stainless Economy Bird Spikes Includes specifications for: Pigeon Spike Stainless models, hardware and surface cleaning.

All work must conform to the National Electric Code, latest edition, and all other applicable codes and regulations.

Report on. Wind Resistance of Signs supported by. Glass Fiber Reinforced Concrete (GFRC) Pillars

Number of Sides Required to Have a Handrail

STANDARD PROCEDURES FOR INSTALLATION OF METAL ROOF SYSTEMS

Transcription:

SECTION 05720 DECORATIVE METAL RAILINGS Architectural Railing System - Dot PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Dot: Stainless steel railing system with glass. B. Related Sections: 1. Section 05710 - Decorative Metal Stairs. 2. Section 05521 - Aluminum Handrails and Railings. 3. Section 05522 - Glass Railings 1.2 REFERENCES A. American National Standards Institute (ANSI) Z97.1 - Safety Performance Specifications and Methods of Test for Safety Glazing Material Used in Buildings. B. ASTM International (ASTM) 1. A240/A240M Standard Specification for Chromium and Chromium-Nickel Stainless Steel Plate, Sheet, and Strip for Pressure Vessels and for General Applications. 2. A554 - Standard Specification for Welded Stainless Steel Mechanical Tubing. 3. C1048 - Standard Specification for Heat-Treated Flat Glass-Kind HS, Kind FT, Coated and Uncoated Glass. 4. E985 - Standard Specification for Permanent Metal Railing Systems and Rails for Buildings. 5. EE2258 Standard Specification for the Performance in Permanent Glass Railings, Guards and Balustrades. C. National Association of Architectural Metal Manufacturers (NAAMM) AMP 503 - Finishes for Stainless Steel. SC Railing Company 05720-1 Decorative Metal Railings

D. ASTM C 1107 - Standard Specification for Packaged Dry, Hydraulic-Cement Grout (Non-shrink); 2002. E. ASTM E 488 - Standard Test Methods for Strength of Anchors in Concrete and Masonry Elements; 1996. F. American Welding Society (AWS): G. ANSI/AWS D1.1/D1.1M Structural Welding Code - Steel. H. Americans with Disabilities Act (ADA). I. Americans with Disabilities Act Accessibility Guidelines (ADAAG). J. International Code Council (ICC): International Building Code. 1.3 SYSTEM DESCRIPTION A. General: Handrails and railings shall withstand structural loading as determined by allowable design working stresses of materials and conform to 2009 International Building Code (IBC). B. Structural Performance: Provide handrails and railings capable of withstanding the following structural loads without exceeding allowable design working stress of materials for handrails, railings, anchors and connections: 1. Top Rail of Guards: Shall withstand the following loads: a. Concentrated load of 200 lbf (0.899kN) applied at any point and in any direction. b. Uniform load of 50 lbf-ft. (0.07kN-m) applied horizontally and concurrently with uniform load of 100 lbf-ft. (0.14kN-m) applied vertically downward. c. Concentrated and uniform loads above need not to be assumed to act concurrently. 2. Handrails Nor Serving As Top Rails: Shall withstand the following loads: a. Concentrated load of 200 lbf (0.89kN) applied at any point and in any direction. b. Uniform load of 50 lbf-ft. (0.07kN-m) applied in any direction. c. Concentrated and uniform loads above need not be assumed to act concurrently. 3. Guards Infill Area: Shall withstand the following loads; a. Concentrated horizontal load of 200 lbf (0.89kN) applied to a 1sq. ft. at any point in system, including panels, intermediate rails, balusters, or other elements composing infill area. Loads need not to be assumed to act concurrently, with loads on top rails in determining stress on guard. C. Thermal Movements: Design handrails and railings to allow for movements resulting from 120 degree F (49 C) changes in ambient and 180 degree F (82 C) surface temperatures. Base SC Railing Company 05720-2 Decorative Metal Railings

engineering calculation on surface temperatures of materials due to both solar heat gain and nighttime-sky heat loss. D. Corrosion Resistance: Separate incompatible materials to prevent galvanic corrosion. 1.4 SUBMITTALS A. Submit under provisions of Section 01300. B. Product Data: Manufacturer's data sheets on each product to be used, including: 1. Preparation instructions and recommendations. 2. Storage and handling requirements and recommendations. 3. Installation methods. C. Shop Drawings: Submit plan and typical section detail to depict the proper configuration, assembly and installation and termination of each product specified in this section. D. Verification Samples: For each finish product specified, two samples, representing actual product, color, and finish. 1.5 QUALITY ASSURANCE A. Manufacturer Qualifications.SC Railing Company, 7008 Northland Drive North, Suite 150; Minneapolis, MN 55428; Toll Free Tel: 877-215-RAIL(7245); Email: info@sc-railing.com. B. Mock-Up: Provide a mock-up for evaluation of surface preparation techniques and application workmanship. 1. Finish areas designated by Architect. 2. Do not proceed with remaining work until workmanship, color, and sheen are approved by Architect. 3. Refinish mock-up area as required to produce acceptable work. C. Railing System: 1. System components: Pre-engineered, designed by licensed Professional Structural Engineer. 2. Attachments to building structure: Designed by Professional Structural Engineer licensed in State in which project is located. D. Perform Work in accordance with ASTM E985. PART 2 - PRODUCTS 2.1 MANUFACTURERS SC Railing Company 05720-3 Decorative Metal Railings

A. Acceptable Manufacturer: SC Railing Company, 7008 Northland Drive North, Suite 150; Minneapolis, MN 55428; Toll Free Tel: 877-215-RAIL(7245); Email: info@sc-railing.com. B. Substitutions: Not permitted. 2.2 MATERIALS A. Stainless Steel: 1. Shapes: ASTM A240/A240M, Type 316. 2. Tube: ASTM A554, Type 316. B. Glass Infill Panels: 1. Type: Fully Tempered. 2. Type: Laminated. 3. Thickness: [1/4] [3/8] [1/2] [3/4] inch. 4. Edges polished. C. Hardware 1. All fasteners substantially concealed. 2. Stainless steel hardware and fasteners. 2.3 ACCESSORIES A. Anchors: Type best suited to application, stainless steel. 2.4 FABRICATION A. Components: 1. Posts: 2 inch x 7/8 inch with 10 degree taper to 1/2 inch trapezoidal type 316 stainless steel bar. 2. Top rail: Type 316 stainless steel diameter round tubing. a. Diameter: [1.5] [2] inch b. Height: 42 inch 3. Handrails: Type 316 stainless steel diameter round tubing. a. Diameter: [1.5] [2] inch b. Height: 36 inch SC Railing Company 05720-4 Decorative Metal Railings

4. Handrail/top rail mountings: Type 316 stainless steel. a. Dot Series, disc type bracket 5. Glass mountings: Type 316 stainless steel. a. Dot Series, disc type bracket 6. Mounting method: a. Surface plate, rectangular b. Fascia plate, rectangular c. Fascia plate, oval d. Fascia discs, node e. Core B. Fabricate railings in accordance with approved Shop Drawings. C. Fabricate railings with joints tightly fitted and secured. Furnish fittings to accommodate site assembly and installation. D. Supply components required for anchorage of railings. Fabricate anchors and related components of same material and finish as railing. E. Conceal fastenings. F. Accommodate for expansion and contraction of members and building movement without damage to connections or members. 2.5 FINISHES A. Stainless Steel: NAAMM AMP 503; [No. 4 Brushed] [No. 6 Satin]. PART 3 - EXECUTION 3.1 INSTALLATION A. Install railing system in accordance with approved Shop Drawings. B. Install components plumb and level, accurately fitted, free from distortion and defects. C. Provide anchors for connecting railings to supporting construction. D. Fit joints tight, flush, and hairline. END OF SECTION SC Railing Company 05720-5 Decorative Metal Railings