Controller board and power supply for vivimat III systems



Similar documents
Universal control module for motorized devices

Video doorphone integration with vivimat III Ref: NA-17_v.III

1 light dimming module

Electronic Control Devices The European Product Catalogue 2007

Version Date Author Description Jpo First version Jpo FET output descriptions made clearer

ModBus Server - KNX. Gateway for integration of KNX equipment into Modbus (RTU and TCP) control systems.

Electronic Control Devices The European Product Catalogue 2007

R&D Access Touch 3.1 User Manual Version 1.00 Public 1 (13) User Manual. Access Touch 3.1

WEA-Base. User manual for load cell transmitters. UK WEA-Base User manual for load cell transmitters Version 3.2 UK

Optimize your simple machines... Modicon M218 Selection Guide

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

Temperature & Humidity SMS Alert Controller

MSITel provides real time telemetry up to 4.8 kbps (2xIridium modem) for balloons/experiments

Always on the Lookout Perfect Protection against Burglary

AC-115 Compact Networked Single Door Controller. Installation and User Manual

Controlers. Controler

MAKING MODERN LIVING POSSIBLE. AK-SC255 On-Site Installation Guide DANFOSS ELECTRONIC CONTROLS & SENSORS

SOLARCARE SERIES PRODUCT AND APPLICATION GUIDE

Zlinx Wireless I/O. Peer-to-Peer and Modbus I/O B&B ELECTRONICS PRODUCT INFORMATION

Climate Ready Control Systems Technical Specifications

Overview. Alarm console supports simultaneous viewing of both live and recorded video when alarm events are selected

INSTALLATION GUIDE. Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930

Class 2 transformer (TBT) Low Tension Conform to EN A LED turns ON when the current exceeds 1 A at the 14V output connector

IntesisBox KNX Modbus TCP master

THYRISTORS T1-1PH from 850A to 2700A Specifications Universal 1 Phase Thyristor Unit , March 2012

IntesisBox. KNX SAMSUNG Air Conditioning. Gateway for integration of Samsung air conditioners into KNX control systems. RS485.

IntesisBox KNX - LON

IntesisBox KNX Modbus RTU master

Job Aid Pre-Installation Information S8500 Media Server

SVC400P/SVC800P. 4/8 Camera Live Tracking Vehicle DVR Installation Manual. Version 1.0

Firmware version: 1.10 Issue: 7 AUTODIALER GD30.2. Instruction Manual

securityprobe 5E Standard

Application/Connection Examples

IntesisBox Modbus Server SAMSUNG Air Conditioners

Modbus Server SAMSUNG Air Conditioners

SECTION DETECTION AND ALARM

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

Manual. IP Sensor and Watchdog IPSW2210. I P S W M a n u a l P a g e 1. Relay Output. Power input. 12VDC adapter LED Indicators. 2 Dry.

WALL TABLET. Smart Home Controller. make your home smart. Control your home from anywhere in the world

Model: DC-A2IO Advanced HVAC Controller

ZC-24DO CANopen I/O Module: 24 Digital Outputs

UM0272 User manual. Central Unit for Alarm System (CUAS) Evaluation Board. Introduction

HCE80/HCC80/HCE80R/HCC80R

How To Use A Powerbook 2.2 (Powerbook 2) For Free On A Computer Or Ipad (Powerware) For A Week Or Two (For A Week) For $99.99 (For An Extended Period Of Time)

IntesisBox KNX LG Air Conditioning

SNMP-1000 Intelligent SNMP/HTTP System Manager Features Introduction Web-enabled, No Driver Needed Powerful yet Easy to Use

Industrial RS-232/ RS-422/ RS-485 over Ethernet Media Converter

Passion for KNX innovation

Full HD(1080P) Resolution Video Wall Box

INTEGRAL REMOTE MANAGEMENT SOLUTION cirwatt b series

M2M/IoT Solutions.

Integrated Building Management and Security System. Building Automation & Security.

KNX Panasonic Air Conditioners

OZS Web server. For LPB/BSB plants

Reference Design. conference rooms

FLEET MANAGEMENT & CAR SECURITY SYSTEM GPRS/GPS

Page 1 / 14 Groupe MOBILITECHMIOSBOX Technical Specification MWP-DT1010. Technical specifications

Alliance System Ordering Guide

Integration of Alarm Systems

TrueAlarm Fire Alarm Systems

Sterowniki uniwersalne z serii IR32. This is a universal step control for low cost solutions

EQUIPMENT SPECIFICATIONS

Technote. Frese OPTIMA Compact actuators DN10-DN32. Application. Features thermic actuators. Features motoric actuators. Approval.

Alpha Climatic Programmable Modulating Boiler Energy Manager. Installation and User Instructions

Climate Ready Shade Operating Systems for residential applications.

Expandable serial alarm system

Compatible with all of the Ravica range of Intelligent Sensors it provides a complete environmental, access control and security monitoring solution.

Inwall 4 Input / 4 Output Module

BURGLAR ALARM SYSTEMS BURGLAR ALARM SYSTEMS BURGLAR ALARM SYSTEM EURO ALARM WIRELESS BURGLAR ALARM SYSTEM OASIS

FLYPORT Wi-Fi G

FX07 Field Controller

SIMATIC S It s the Interplay that makes the difference. Siemens AG All Rights Reserved.

Uninterruptible Power Supply

INTERFACING SECURITY SYSTEMS TO HOMEVISION

Innovative Electronics for a Changing World INDEX

Ponto Series. A new concept for automation

MILLENIUM INSTALLATION MANUAL NTR 735 A. Simple Automation Control Module (MAS)

Remote Monitoring and REC 501 Control Unit Product Guide

GTR-128/GTR-129 Motorcycle/ Vehicle Tracker Quick Start Guide

BIBUS VOP. large blocks of flats with switchboard and mixed mainly audio systems. Ideal for door phone systems with up to 250 users.

Elvey is a leading distributor of electronic security equipment in Africa. Our vision is to assist in the protection of people and property by

Remote monitoring & control solutions for cathodic protection rectifier

Overview. 1. GPS data tracking via GSM SMS / GPRS. 2. GPS data logging in internal memory. 3. Alarm alert via GSM SMS / Dialing / GPRS

HMI display Installation Guide

NGSS Data Consolidator (DC)

Positioner Versions. Remote feed-back. Local display, Electric / Hydraulic. Remote feed-back Electric / Hydraulic. Embedded Control Positioner

SMS GSM Alarm Messenger

Regards from the Team at Rheology Solutions.

Security. Alarm central unit. Ref.-No. KNX Alarm central unit EAM 4000

USER MANUAL V5.0 ST100

Ensto Chago Master EVM300 and EVM500 Operational description

IntesisBox Modbus Server - Mitsubishi Electric G50

Shutter Actuator Standard, 4-fold, 230 VAC, MDRC RA/S , GH Q R0111. ABB i-bus EIB

AR-721U/721K/661U User s Guide

A-317. Mobile Data Terminal. Android Platform Datasheet

Network Video Recorder Quick Operation Guide

Fibaro electronic modules are smallest devices of the type in the World and can be installed in all standard wall switch boxes,

FX07 Field Controller

Electronics Ltd. Presenting. Power, Intelligence... with a sense of feeling

Transcription:

Controller board and power supply for vivimat III systems Ref: VIVIMAT-3.0 The controller board and power supply vivimat 3.0, is the central core of the vivimat III home automation system. The vivimat III systems, have high expansion capabilities, thanks to the optional modules that can be mounted on the vivimat 3.0 controller board and power supply, and also thanks to the variety of modules that can be connected to the vivimat III control BUS. The vivimat III systems, have high expansion capabilities, thanks to the optional modules that can be mounted on the vivimat 3.0 controller board and power supply, and also thanks to the variety of modules that can be connected to the vivimat III control BUS Technical characteristics External power supply 220VAC/50 o 60Hz Internal power supply 15VDC Internal consumption <100mA Power supply output for components of the vivimat III system 12-14VDC (1,25A con ALM- 0021) *See note. vivimat III systems power supply Temperature range 0-50ºC Battery (optional) hosted by vivimat 3.0 BAT-0190 /1,9Ah Expansion BUS 2 RS - 485 Interfaces BUS / control BUS Communication protocol vivimat III protocol optional Max. modules number per BUS 64* * Depending of the installation BUS load a RS485 repeater might be needed for less than 64 devices. (Include one in the system in case the communication fails)

HARDWARE CAPACITIES: Digital inputs ** 8 Analog inputs (0-10V ) 1 Current input 1 Digital relay outputs (5A @ 230Vac) 4 Transistorized digital outputs 4 Expansion connectors on board 3 Expansion Bus 1 Integrated serial port communication 2 (+3 opt.) Connection to the PSTN (switched tel. network) Integrated GSM connection Optional (MOD-0001 + MOD-0350 Firmware updates via... micro SD Allows remote reprogramming Coming soon SOFTWARE CAPACITY: Alarm zones / Areas 40/20 Climate control zones 10 Scenes 20 Events per scenes 20 Devices/plugs 20 Irrigation areas 50 Individually controlled motorized devices 50 Lighting zones (ON/OFF+Dimmer) 50 Dimming light control Max. number of screens per system 3 MODULES CONNECTED TO THE CONTROLLER BOARDS: Video doorphone system module MOD-0200 (1) Wired IP module MOD-0360 (1) Audio expansion module MOD-0800 (1) Expansion plate MOD-0001 (1) Series expansion module Coming soon GSM module MOD-0350* (1) CONTROL MODULES CONNECTED TO THE CONTROL BUS: RFID tag reader connected to BUS MOD-0046N (8) IR module connected to BUS MOD-0055N (8) Blinds module connected to BUS MOD-0105N (50) Expansion module MOD-0035-N(32) Light dimmer module MOD-0450 (50) Light module ON/OFF MOD-0415 (25) *Required MOD-0001 (NOT INCLUIDED) to connect MODULES CONNECTED TO OUTPUTS: Relay module MOD-0031 (1) Blinds module MOD-0102 (Can also be used as slaves of the MOD-0105-N)

Dimensions and included components COVER CHASSIS 273 mm 215 mm 408 mm 305 mm Standard components: (included) - Ref: ALM-0011 / 0021 / 0022 - Ref: VIVIMAT 3.0 - Packaging documentation Expansion plate 05 06 07 08 +V3 01 02 03 04 GND SIN SOUT GND GND TT +V4 +V1 +V1 +V1 +V1 GND +VA GND +VB CN5A CN5B CN27B TP19 exp. Audio Optional components: - Ref: MOD-0035 - Ref: BAT-0190 - Ref: MOD-0350 - Ref: MOD-0360 - Ref: MOD-0001 - Ref: MOD-0200 - Ref: MOD-0800 CN10 CN3 - USB ETHERNET MAIN BOARD OF VIVIMAT 3.0 CN26 Video-doorphone GSM TAMPER MEMORY CARD A1 -V2 GND B1 A2 +V2 GND B2 IN1 IN2 GND IN3 IN4 IN5 IN6 GND IN7 IN8 GND AIN FIN PHONE LINE

Connections EXTERNAL PHONE INTERNAL PHONE ACTUATORS >5A FIRE ACTUATORS >16A MOD-0031 SOUND OF SCREENS SENSORS POWER SUPPLY GROUND 05 06 07 08 +V3 01 02 03 04 GND SIN SOUT GND GND TT +V4 +V1 +V1 +V1 +V1 GND +VA GND +VB CN27B TP19 CN5A CN5B CN10 CN26 MAIN BOARD OF VIVIMAT 3.0 MEMORY CARD A1 +V2 GND B1 A2 +V2 GND B2 IN1 IN2 GND IN3 IN4 IN5 IN6 GND IN7 IN8 GND AIN FIN PHONE LINE TAMPER CONTROL BUS INTERFACE BUS TEMPERATURE DIGITAL SENSORS CONFIGURATION CONTROL MODULES SCREENS FIRE SENSOR POWER SUPPLY ANTISABOTAGE GENERAL POWER SUPPLY SUPPORT BATTERY - Wiring: Power supply 3x1,5mm2. Tel. 2 pairs of rigid telephone wire. Wiring required for the other elements of the system. See wiring requirements of each element.

Installation recommendations - Installation 1: The BOX-0030 (not included) is embedded in the wall of the housing. With 4 screws we fix the controller board to the BOX-0011. Afterwards, we use 4 screws to fix the cover on the BOX-0011. BOX-0030 vivimat 3.0 controll board Cover - Installation 2: As long as the battery is located at the bottom, the vivimat 3.0 controller board can also be placed vertically. Battery localization - Location: Inconspicuous location, ventilated and accessible for repair. FT_VIVIMAT-3.0_23/11/11_ENG Product manufactured by: Dinitel 2000 S.A. - Avda. Otaola 20 20600 Eibar ( Guipúzcoa ) Spain T. +34 902 111 220 / +34 943 820 458 F. +34 902 124 779 www.domotica-vivimat.com dinitel@dinitel.com