The use of the Kitemark is authorized in respect of the Product(s) detailed on this Licence provided at or from the above address.

Similar documents
Product Data Sheet. User Manual. User Manual MX-4100, MX-4200, MX-4400, Mx-4400/LE & Mx-4800 Fire Alarm Control Panels

Analogue addressable devices

VEGA Analogue Addressable Control Panels

Electronics Ltd. Presenting. Power, Intelligence... with a sense of feeling

Control and Indicating Equipment

Technical Data Sheet

Kentec Electronics Ltd. Units Fawkes Avenue Questor Dartford Kent DA1 1JQ England Tel: +44(0) Fax: +44(0)

Fire detection equipment

Engineer Paging. Staff Paging. Deaf Alert.

EVC40 EMERGENCY VOICE COMMUNICATION SYSTEM

Conventional Fire Detection and Extinguishant Control System Specification

The Leading Multiprotocol Intelligent Fire Panel

FIRE ALARMS SYSTEMS - UCL GENERAL INSTALLATION EMPLOYERS & REQUIREMENTS DESIGN GUIDANCE

MX-4100, MX-4200, MX-4400,

25 Years of Manufacturing Excellence. Premier Quatro Addressable Fire Alarm System. Assessed to ISO 9001: 2008

ALARMLINE ANALOGUE Linear Heat Detection System

CFP 2/4/8 ZONE CONVENTIONAL FIRE ALARM CONTROL PANEL. user manual & log book. Approved Document No. DFU Rev 1

radio fire alarm system Installed with minimum disruption Provides maximum protection

Emergency voice communications Product Name

USER MANUAL, MAINTENANCE GUIDE & LOG BOOK

FIRE ALARMS SYSTEMS - UCL GENERAL INSTALLATION DESIGN GUIDANCE & EMPLOYERS REQUIREMENTS

Notifier by Honeywell: Voice Alarm Solutions

Proposed changes to the Acceptable Solution for Building Code clause F7 (Warning Systems) Proposed amended Acceptable Solution for Warning Systems

COMITÉ EUROPÉEN DES ASSURANCES

Syncro. Multi Loop Analogue Addressable Fire Control Panel. Product Manual Man-1055 Issue 26 May 2016

Fire Detection Product Range

25 Years of Manufacturing Excellence INFINITY. The Intelligent 2 Wire Fire Detection System for Professionals

Fax: Telephone Number of your Alarm System. Get the list of commands sent to your phone

FIRE DETECTION AND ALARM SYSTEMS

FDX Spider ALARM SYSTEM SHORT FORM USER GUIDE V1.6. SyxthSense Ltd

FIRE ALARMS. IN DWELLINGS By John Ware FIRE ALARMS

Performance Specification for Pedestrian Facilities at Temporary Standalone Traffic Signals

Firmware Update Notice

28 th April 2005 Version Final 1.1 CODE OF PRACTICE FOR THE AUTOMATIC FIRE ALARM SYSTEM. Copyright New Zealand Fire Service Page 1 of 1

Emergency Voice Communication Systems EVCS Network 8 Data Sheet

Application Guide HMOs

FIRE ALARMS AND DETECTION SYSTEMS EQUIPMENT

AlarmSense 2-wire detection and alarm system. Product Guide

Advanced Intelligent Modules. Overview. Description

DOMESTIC ELECTRICAL INSTALLATION CERTIFICATE (Requirements for Electrical Installations BS 7671 IEE Wiring Regulations)

XFP NETWORKABLE ANALOGUE ADDRESSABLE FIRE ALARM CONTROL PANEL. user manual and log book. Approved Document No. DFU Rev 1

Remote Monitoring and Control of Traffic Control Equipment via a Telecommunications Network

How To Comply With The Loss Prevention Certification Board

Product Information Sheet UH28CS-12kV Hi Pot Tester

Construction. Using today s standards to build the future

Syncro. Multi Loop Analogue Addressable Fire Control Panel. Product Manual. Man-1055 Issue 21 September 2010

Fire. The Fire Installers Mate. A guide to fire alarm systems design

Syncro AS. Analogue Addressable Fire Control Panel. Product Manual Man-1096 Issue 14 May 2016

FIREvac VOICE ALARM CONTROL PANEL INSTALLATION & MAINTENANCE MANUAL

CONTENTS. GST102A/104A/108A/116A Conventional Fire Alarm Control Panel Installation and Operation Manual

Compliance Document for New Zealand Building Code Clause F7 Warning Systems Fourth Edition

Repeaters and Mimics Data Sheet

Guidance for Electrical Contractors on Emergency Lighting Legislation

LIFT CONTROL SYSTEMS CATALOGUE 2007

EMERGENCY LIGHTING - UCL GENERAL DESIGN GUIDANCE

FIRE SAFETY PRECAUTIONS

Fire Alarm Systems Care and Maintenance

NJP-400A NJP-401A. Safely into a new day. Advanced modular FIRE ALARM CONTROL PANEL with additional functionality. I m on FIRE (Bruce Springsteen)

Drayton Digistat +2RF/+3RF

Master & Amplifier For ModuSat Communal Heating

LIFT CONTROL SYSTEMS CATALOGUE 2007

C e r t i f i c a t e of Conformity

Project Name: Nortrax Section Project No: SURGE PROTECTION DEVICES Page 1

NELSON VOLTAGE MONITOR INSTALLATION & PROGRAMMING MANUAL

Electronic Fire and Security Systems Installation: Commissioning (SCQF level 6)

3½ DIGIT VOLTMETER MODULE LED- / LCD- SERIES

High voltage tester HA 1800 Table-top device

CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE. General purpose single phase thyristors and solid state relays Product data.

DELAWARE STATE FIRE MARSHAL FIRE ALARM SYSTEM CERTIFICATE OF INSTALLATION

Quality Management Standard BS EN ISO 9001:

B A S I C S C I E N C E S

2-Way Wireless Indoor Siren Installation Guide

Fire Pump Controllers Remote Alarm Panels

GUARDIAN REFUGE & EMERGENCY VOICE COMMUNICATION SYSTEMS

S4000TH HART. HART Communication Manual

FIREDEX Conventional Fire Panels

500r+ Installation and User Guide

Environmental Planning and Assessment Amendment (Conversion of Fire Alarm Monitoring) Regulation 2002

BS5839 Part 1:2002 Overview

Software Release For DF6000/CF3000/FX6000. Site Installer Network Card

Emergency Lighting Practices in the UAE. Richard Caple MSc MSLL Lighting Applications Manager SLL Vice President

Fire Alarm system Installation Guide

MODULAR JUNCTION BOX MJB WITH GATEWAY

CHECKING AND TESTING ELECTRICAL INSTALLING WORK

GENERATOR TRANSFER SWITCH

Fire Standards & Regulations Are you confused?

CHARGING STATIONS FOR ELECTRIC VEHICLES QUICK CHARGER

Surveyor Excel-K. Fire Alarm Control Equipment. Installation, Commissioning and Operating Manual

TECHNICAL SPECIFICATION FOR PRIVATE AUTOMATIC BRANCH EXCHANGE (PABX) SYSTEM FOR CONNECTION TO PUBLIC SWITCHED TELEPHONE NETWORK (PSTN)

Residential Gateway (RG) Battery Backup

Triple Waveband Infra-Red Flame Detection

ELR: ABB range of front panel residual current relays Protection device according to IEC/EN Annex M

Installation and Operation Manual

Greater Manchester Fire and Rescue Service

AVAILABLE TO DOWNLOAD ON THE APOLLO APP. Fire Alarm Systems Design. a guide to BS5839

User s Manual Before using the inverter, you need to read and save the safety instructions.

welcome to our world fire alarm systems - series 600

Fire Safety Requirements for Child Care Centre

ARMAGH BANBRIDGE AND CRAIGAVON DISTRICT COUNCIL CINEMAS (NORTHERN IRELAND) ORDER 1991

T O K I S T A R L I G H T I N G I N S T R U C T I O N M A N U A L LC-1CH-MULTI Dimmer Module

Transcription:

The British Standards Institution hereby grants to: Advanced Electronics Ltd 34 Moorland Way Nelson Park Cramlington Northumberland NE23 1WE United Kingdom In respect of: BS EN 54-2 & BS EN 54-4 Fire Panel & Power Supplies This issues the right and licence to use the Kitemark in accordance with the Kitemark Licence Conditions of Contract governing the use of the Kitemark, as may be updated from time to time by The British Standards Institution, and as approved by the Registrar under the Trade Marks Act 1994 (the "Conditions"). All defined terms in this Licence shall have the same meaning as in the Conditions. The use of the Kitemark is authorized in respect of the Product(s) detailed on this Licence provided at or from the above address. For and on behalf of The British Standards Institution: David W. Ford, Executive Director, Healthcare & Testing Services First Issued: 25/02/2003 Latest Issue: 18/08/2010 Page 1 of 7

Mx-4100 Mx-4200 Mx-4400 Mx-4800 1 Loop Analogue Addressable Control and Indicating Equipment Certified for use with Hochiki ESP and Apollo Discovery, Explorer XP95 and series 90 loop devices C dependency (clause 7.12.3) First Issued: 25/02/2003 Latest Issue: 18/08/2010 Page 2 of 7

Mx-4200N Mx-4400N Mx-4800N Certified for use with Nittan fire detection and alarm devices C dependency (clause 7.12.3) First Issued: 25/02/2003 Latest Issue: 18/08/2010 Page 3 of 7

FIREline-1 FIREline-2 FIREline-4 FIREline-8 1 Loop Analogue Addressable Control and Indicating Equipment Certified for use with Hochiki ESP loop fire detection and alarm devices C dependency (clause 7.12.3) First Issued: 25/02/2003 Latest Issue: 18/08/2010 Page 4 of 7

Mx-4200V Mx-4400V Mx-4800V Certified for use with Argus Vega fire detection and alarm devices C dependency (clause 7.12.3) First Issued: 25/02/2003 Latest Issue: 18/08/2010 Page 5 of 7

Mx-5100 Mx-5200 Mx-5400 1 Loop Analogue Addressable Control and Indicating Equipment 2 Loop Analogue Addressable Control and Indicating Equipment Certified for use with Hochiki ESP and Apollo Discovery, Explorer XP95 and series 90 loop devices Output to fire alarm devices clause 7.8 Output to fire alarm routing equipment clause 7.9 Output to fire protection equipment clause 7.10 Output type A clause 7.10.1 Output type B clause 7.10.2 Output type C clause 7.10.3 Fault monitoring of fire protection equipment clause 7.10.4 Delays to outputs clause 7.11 Dependencies upon more than one alarm signal clause 7.12 Alarm counter clause 7.13 Fault signals from points clause 8.3 Output to fault warning routing equipment clause 8.9 Disablement of addressable points clause 9.5 Test condition clause 10 Standardise input / output interface clause 11 First Issued: 25/02/2003 Latest Issue: 18/08/2010 Page 6 of 7

Power Supply Equipment complying with BS EN54 Part 4: 1998 +A1 & A2 MxP-049 MxP-050 MxP-051 1.5 Amp Switch Mode Power Supply Equipment (capable of charging 7Ahr Batteries) 3.0 Amp Switch Mode Power Supply Equipment (capable of charging 17Ahr Batteries) 5.0 Amp Switch Mode Power Supply Equipment (capable of charging 38Ahr Batteries) Enclosure dimensions are as follows: 7Ahr Enclosure - H=320 x W=345 x D=88mm 17Ahr Enclosure - H=425 x W=406 x D=125mm 38Ahr Enclosure - H=425 x W=406 x D=190mm First Issued: 25/02/2003 Latest Issue: 18/08/2010 Page 7 of 7