DIGITAL MULTIMETER Model No: CDM20. PartNo:

From this document you will learn the answers to the following questions:

What value is needed to make DC measurements?

What is the polarity of the test lead?

What is the main component of the device that is used to test transistors?

Similar documents
Model UT33A: OPERATING MANUAL Table of Contents (1)

Auto-ranging Digital Multimeter INSTRUCTION MANUAL

UT202A Operating Manual. Contents

Model UT33B/C/D: OPERATING MANUAL Table of Contents (1)

Model UT58A/B/C: OPERATING MANUAL

Model UT201/202: OPERATING MANUAL. Table of Contents

Manual Ranging MultiMeter

AutoRanging Digital MultiMeter

Table of Contents. Page

User's Guide. True RMS Industrial Multimeter

Instruction Manual. 2in1 LAN Tester & Multimeter. Model: LA-1011

Owner s Manual & Safety Instructions

How To Use A Cdm250 Digital Multimeter

7 FUNCTION DIGITAL MULTIMETER

Seven function digital multimeter

DIGITAL MULTIMETER OPERATION MANUAL ITEM DIGITAL MULTIMETER CONTENTS

10 Multimeter. Users Manual

Model UT60A: OPERATING MANUAL. Table of Contents. Page

Model UT61A/61B/61C/61D/61E: OPERATING MANUAL. Table of Contents

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODELS:

i410/i1010 AC/DC Current Clamp

The table below lists the symbols used on the Clamp and/or in this manual. Important Information. See manual.

Table of Contents. The Basics of Electricity 2. Using a Digital Multimeter 4. Testing Voltage 8. Testing Current 10. Testing Resistance 12

HOW TO USE MULTIMETER. COMPILE BY: Dzulautotech

1587/1577. Insulation Multimeters. Technical Data. Two powerful tools in one.

Intelligent Digital Multimeters

User Guide. Model Insulation Tester / Megohmmeter

EPM3. Phase Sequence and Motor Rotation Tester. Users Manual

User Guide. 4 wire Earth Resistance Tester Model GRT300

323/324/325. Calibration Manual. Clamp Meter

AVO410. Digital multimeter Digitale Multimeter Multimèter numérique Multímetro digitales Digitale multimeter

Model UT71A/B OPERATING MANUAL

Essential Electrical Concepts

User s Manual Before using the inverter, you need to read and save the safety instructions.

Model 1756 Test Lead Kit

INTRODUCTION SAFETY PRECAUTIONS/

HVAC Clamp Meter. Users Manual

Ground Resistance Clamp On Tester

Instructions A Amp AC/DC Current Probe

User s manual FLIR VP50/VP52 Non-contact AC voltage detector

Users Manual. ProcessMeter

12-Volt 10-Amp Regulated Power Supply

ABCs of DMMs Multimeter features and functions explained Application Note

1. SAFETY INFORMATION

Table of Contents. Page No.

Thermistor Thermometer MODEL NO

POWER SUPPLY MODEL XP-15. Instruction Manual ELENCO

INFRARED QUARTZ WALL HEATER

T+ and T+ PRO Electrical Tester

Table of Contents. Title

Multimeter with Temperature

Owner s Manual & Safety Instructions

162 CB CABLE TRACER. Filter Probe & Tone Generator INSTRUCTION MANUAL

Integrating Sound Level Meter and Datalogger

Instruction Manual IDM 71/72/73 Digital Multimeter EN FR IT DE

Mini Power Bank and Charger

OPERATION MANUAL. Pen type, separate electrode SOIL PH METER Model : PH-220S

Model UT713 OPERATING MANUAL

1587/1577. Insulation Multimeters. Users Manual

Peak Atlas DCA. Semiconductor Component Analyser Model DCA55. User Guide

Hygro-Thermometer + InfraRed Thermometer Model RH101

Dual Display Digital Multimeter

Current Monitoring Kit QUICK START GUIDE

ANADOLU UNIVERSITY DEPARTMENT OF ELECTRICAL AND ELECTRONICS ENGINEERING

Talon VFD / Inverter Meter

RS DIGITAL THERMOMETER

Example of use: Fuse for a solenoid valve. If the fuse is defective, no information is sent to the electronic component.

VOLTAGE/CURRENT CALIBRATOR ISO-TECH ILC-421

115C and 117C. True-rms Multimeters. Users Manual

Operating instructions in the back. PD1020L

How To Use A Power Supply Unit (Upu)

Multifunction Process Calibrator

What is a multimeter?

TMS TANK MANAGEMENT SYSTEM

Thermocouple Thermometer Models

Digital Ground Resistance Tester. Models 4620 & Digital Ground Resistance Tester

AMP-210 AMP-210-EUR AMP-220 AMP-220-EUR AMP-310 AMP-310-EUR AMP-320 AMP-320-EUR. 600A AC TRMS Clamp Multimeter. 600A AC / DC TRMS Clamp Multimeter

Ground Resistance Clamp-On Tester

Agilent 87421A/87422A Power Supply

Digital Clamp-on DMMs with uncompromising performance

The full wave rectifier consists of two diodes and a resister as shown in Figure

TIG INVERTER INSTRUCTION MANUAL

Current Monitoring Kit

Achat 115MA full-range speaker. user manual

400 Amp Rechargeable Jump Start System RAC-HP082

USER S MANUAL. MaxPower UPS. Uninterruptible Power System 28-2MAXPO0018

Panel Meters and Controllers Modular Panel Meter Type EDM 35

FLUORESCENT UV- RING LIGHT OPERATING INSTRUCTION

Model 77 Series IV Digital Multimeter

Fig. 1 Analogue Multimeter Fig.2 Digital Multimeter

AC Direct Off-Line Power Supplies

DC POWER SUPPLY ALIMENTATION C.C.

Microwave Meter. Instruction Manual

Battery Power Inverters

Diode Applications. As we have already seen the diode can act as a switch Forward biased or reverse biased - On or Off.

Agilent U1230 Series Handheld Digital Multimeters (DMMs)

EPGM1 HARDWIRED ZONE & PGM OUTPUT EXPANSION MODULE

Power Supplies. 1.0 Power Supply Basics. Module

EE-SX91. Meeting Customer Needs with Compact Sensors that Mount with M3 Screws

RADIANT PLASMA 4700 Plasma Spark Generator

Transcription:

DIGITAL MULTIMETER Model No: CDM20 PartNo: 4500007 0607

WARNING Before attempting to open the case, Always be sure that test leads have been disconnected from measurement circuits. Close case and tighten screws completely before using the meter to avoid electrical shock hazard. DO NOT dispose of this product with general household waste. It must be disposed of according to all laws governing waste electrical and electronic products at a recognised disposal facility

WARNING Before attempting to open the case, ALWAYS ensure that the test leads have been disconnected from their measurement circuits. Close the case and tighten the screws completely before using the meter to avoid the possibility of electric shock Thank you for purchasing this CLARKE Digital Multimeter. Please read this leaflet thoroughly and follow the instructions carefully, in doing so you can look forward to the multimeter giving you long and satisfactory service. Guarantee This CLARKE product is guaranteed against faulty manufacture for a period of 12 months from the date of purchase. Please keep your receipt as proof of purchase. This guarantee is invalid if the product is found to have keen abused or tampered with in any way, or not used for the purpose for which it was intended. Faulty goods should he returned to their place of purchase. No product can he returned to us without prior permission. This guarantee does not effect sour statutory rights. CDM-20 Page-2

CONTENTS PAGE 1. SAFETY INFORMATION... 1 1.1 PRELIMINARY... 1 1.2 DURING USE... 2 1.3 SYMBOLS... 3 1.4 MAINTENANCE... 4 2. DESCRIPTION... 5 3. OPERATING INSTRUCTIONS... 8 3.1 MEASURINGVOLTAGE... 8 3.2 MEASURING CURRENT... 9 3.3 MEASURING RESISTANCE... 10 3.4 TESTING DIODE... 11 3.5 TESTING TRANSISTOR... 11 CDM-20 Page-3

3.6 CONTINUITY TEST... 12 4. SPECIFICATIONS... 13 4.1 GENERAL... 13 4.2 DC VOLTAGE... 15 4.3 AC VOLTAGE... 16 4.4 DC CURRENT... 17 4.5 ACCURRENT... 18 4.6 RESISTANCE... 19 4.7 DIODE AND AUDIBLE CONTINUITY TEST... 20 4.8 TRANSISTOR life TEST... 20 5. ACCESSORIES... 21 6. BATTERY & FUSE REPLACEMENT... 21 CDM-20 Page-4

1. SAFETY PRECAUTIONS This multimeter has been designed according to leg-lob concerning electronic measuring instruments with an overvoltage category (CAT II) and pollution 2. Follow all safety and operating instructions to ensure that the meter is used safely and is kept in good operating condition. 1.1 PRELIMINARY When using this meter, the user must observe all normal safety rules concerning: Protection against the dangers of electronic current. Protection of the meter against misuse. Full compliance with safety standards can be guaranteed only if used with the test leads supplied. If necessary, they must be replaced with the same model or same electronic ratings. Measuring leads must be in good condition. Replacements are available from CLARKE International - see back page. CDM-20 Page-5

1.2 DURING USE Never exceed the protection limit values indicated in specifications for each range of measurement. When the meter is linked to measurement circuit, do not touch unused terminals. When the value scale to be measured is unknown before hand, set the range selector at the highest position. Before rotating the range selector to change functions, disconnect test leads from the circuit under test. Never perform resistance measurements on live circuits. Always be careful when working with voltage above 60V dc or 30V AC rms. Keep fingers behind the probe barriers while measuring. Before attempting to insert transistors for testing, always be sure that test leads have been disconnected from any measurement circuits. Components should not be connected to the hfe socket when making voltage measurements with test leads. CDM-20 Page-6

1.3 SYMBOLS Important safety information, refer to the operating manual. Dangerous voltage may be present. Earth ground. Double insulation ( Protection class II). A Fuse must be replaced with ratings specified in the manual. 1.4 MAINTENANCE Before opening the meter, always disconnect test leads from all sources of electric current. For continue protection against fire, replace fuse only with the specified voltage and current rating: F 2A1250V (quick acting). If any faults or abnormalities are observed, the meter cannot be used. It must be inspected and repaired by a qualified technician, or returned to CLARKE International for repair. Never use the meter unless the back cover is in place and fastened fully. Do not use abrasives or solvents on the meter, use a damp cloth and mild detergent only. CDM-20 Page-7

2. DESCRIPTION This meter is a compact, rugged, battery operated, handheld 3 ½ digit multimeter, capable of performing the following functions: DC and AC voltage measurement DC and AC current measurement Resistance measurement Diode measurement Audible continuity test Transistor hee measurement The Dual-slope A/D Convert uses CMOS technology for auto-zeroing, polarity selection and overrange indication. Full overload protection and low battery indication are provided CDM-20 Page-8 0.888 1. Power Switch 2. Display 3. Transistor Testing Socket 4. Rotary Switch 5. Input Jacks

2.1 POWER SWITCH A push - push switch is used to turn the meter on or off. 2.2 DISPLAY 3 ½ digit, 7 segment, 18mm high LCD. 2.3 FUNCTION AND RANGE SELECTOR There are different functions and 32 ranges provided. A rotary switch is used to select functions and ranges. 2.4 INPUT JACKS 1. COM jack - Plug in connector for black (negative) test lead 2. V/Ω jack - Plug in connector for red (positive) test lead for voltage and resistance. 3. 2A jack - Plug in connector for red test lead for current (2A MAX). 4. 10A jack - Plug in connector for red test lead for 10A measurement. CDM-20 Page-9

3. OPERATING INSTRUCTIONS 3.1 MEASURING VOLTAGE 1. Connect the black test lead to the COM jack and the red test lead to the V/Q jack. 2. Set the rotary switch at the desired V or V ~ range position and connect test leads across the source or load under measurement. The polarity of the red lead connection will be indicates along with the voltage value when making DC voltage measurement. 3. When only the figure 1 is displayed, it indicates overrange situation and the higher range has to be selected CDM-20 Page-10

3.2 MEASURING CURRENT 1. Connect the black test lead to the COM jack and the red test lead to the A jack for a maximum of 2A current For a maximum of 20A, move the red lead to the 10A jack. 2. Set the rotary switch at desired A or A ~ range position and connect test leads in series with the load under measurement The polarity of the red lead connection will be indicated along with the current value when making DC current measurement. 3. When only the figure 1 displayed, it indicates overrange situation and the higher range has to be selected CDM-20 Page-11

3.3 MEASURING RESISTANCE 1. Connect the black test lead to the COM jack and the red test lead to the V/Ω jack. (The polarity of red lead is + ) 2. Set the rotary switch at desired Q position and connect test leads across the resistor under measurement. NOTE 1. If the resistance being measured exceeds the maximum value of the range selected or the input is not connected, an overrange indication 1 will be displayed. 2. When checking in-circuit resistance, be sure the circuit under test has all power removed and that all capacitors have been fully discharged. 3. For measuring resistances above 1M Ω the meter may take a few seconds to stabilise. This is normal for high resistance measurements. CDM-20 Page-12

3.4 TESTING DIODE 1. Connect the black test lead to the COM jack and the red test lead to the V/Ω jack. (The polarity of red lead is +. 2. Set the rotary switch at the position and connect red lead to the anode, black lead to the cathode of the diode under testing. The meter will show the approx. forward voltage of the diode. If the lead connection is reversed, only figure 1 displayed. 3.5 TESTING TRANSISTOR 1. Set the rotary switch at hfe position. 2. Determine whether the transistor to be tested is NPN or PNP type and locate the Emitter, Base and Collector leads. Insert leads of the transistor into proper holes of the transistor testing socket. 3. The meter will show the approx. hfe value at test condition of base current 10µA and Vce 2.8V. 3.6 CONTINUITY TEST 1. Connect the black test lead to the COM jack and the red test lead to the V/Ω jack. (The polarity of the red lead is positive + 2. Set the rotary switch at position and connect test leads across two points of the circuit under test. If continuity exists (i.e. resistance less than about 30Ω), built-in buzzer will sound. CDM-20 Page-13

4.SPECIFICATIONS Accuracy is specified for a period one year after calibration and at 18º C to 28º C (64º F to 82º F) with relative humidity to 80 %. 4.1 GENERAL Maximum Voltage between... CAT II 1000V. Teminal and Earth Ground... CAT III 600V. Fuse Protection... A: F 2A1250V; 10A: unfused. Power Supply... 9V battery, Neda 1604 or 6F22. Display... LCD, 1999 counts, updates 2-3/sec. Measuring Method... Dual-Slope integration ND converter. Overrange indication... 1 figure only on the display. CDM-20 Page-14

Polarity indication... - displayed for negative polarity. Operating Temperature... 0ºC to40ºc (32ºF to l04ºf). Storage Temperature... 10ºC to 50ºC (14ºF to 122ºF). Temp for guaranteed accuracy... 23ºC ± 5ºC. Low Battery Indication... appears on the display. Size ( W x L x H)... 88W x 172L x 36H mm. Weight... 370g (including battery). CDM-20 Page-15

4.2 DC VOLTAGE Range Accuracy Resolution 200mV 100µV 2V 1mV 20V ± 0.5% of rdg ±1 digits 10mV 200V l00mv 1000V lv Input Impedance: 10MΩ on all ranges. Overload Protection: 250 V rms AC for 200mV range, 1000 V peak or 700 V rms AC for other ranges CDM-20 Page-16

4.3 AC VOLTAGE Range Accuracy Resolution 200mV ±1.2 % of rdg + 3 digits 100µV 2V 1 mv 20V ±0.8 % of rdg + 3 digits 10mV 200V l00mv 700V ±1.2% of rdg + 3 digits 1V Input Impedance: Frequency Range: Overload Protection: 10MΩ on all ranges. 40Hz to 1 khz; Indication: Average (rms of sine wave). 250V rms AC for 200mV range and 1000V DC or 700V rms AC for other ranges. CDM-20 Page-17

4.4 DC CURRENT Range Accuracy Resolution 20µA ± 2.0 % of rdg+ 5 digits 10nA 200µA 0.1µA 2mA ±0.8% of rdg + 1 digits 1µA 20mA 10µA 200mA ± 1.2 % of rdg ± 1 digits 100µA 2A 1mA 10A ±2.0% of rdg + 5 digits l0ma Max Input Current: Overload Protection: 2A:2A. 10A:10A continuous, 20A 15 sec.max. 2A/250V fuse (10A range unfused); Measuring Voltage Drop: 200mV CDM-20 Page-18

4.5 AC CURRENT Range Accuracy Resolution 20µA ±3.0% of rdg + 7digits l0na 200µA 0.1µA 2mA ±1.0% of rdg + 3digits 1µA 20mA 10µA 200mA ± 1.8% of rdg 3 digits 100µA 2A 1mA 10A ± 3.0% of rdg + 7 digits l0ma Max Input Current: Overload Protection: Indication: 2A2A. 10A10A continuous,.20a 15 sec MAX 2A/250V fuse (10A range unfused); Frequency Range 40Hz to 1kHz Average (rms of sine wave) Measuring Voltage Drop 200mV CDM-20 Page-19

4.6 RESISTANCE Range Accuracy Resolution 200Ω ±0.5% of rdg + 3 digits 0.1Ω 2KΩ 1Ω 20KΩ ±0.5% of rdg + 1 digit 10Ω 200kΩ 100Ω 2MΩ 1 KΩ 20MΩ ±1.0% of rdg + 2digits 10KΩ Overload Protection: Open Circuit Voltage: 250V DC/AC rms on all ranges. Less than 700mV. CDM-20 Page-20

4.7 Diode and Audible Continuity Test Range Description Test Condition Display read approximate forward Forward DC current approximately 1mA. voltage of diode Reversed DC voltage approximately 2.8V. Built-in buzzer sounds ifresistance is Open Circuit Voltage approximately 2.8V. less than approximately 30Ω Overload Protection: Sounds alarm (250V AC/DC rms) 4.8 Fransistor hee Test Range Description Test Condition hfe Display read approximate hfe value Base Current approx l0µa VCE (0-1000) transistor under test (ALL TYPE) approximately 2.8V. CDM-20 Page-21

5. ACCESSORIES Test leads Electric Rating 1500V, 10A MASTECH HYTL 095 Battery 9V NEDA 1604 or 6F22 Operating Manual HYS004343 6. BATTERY & FUSE REPLACEMENT If the sign -+ appears on the LCD display, it indicates that battery should be replaced. Remove screws on the back cover and open the case. Replace the exhausted battery with a new one. The fuse should rarely need replacement and will blow almost always as a result of operator error. Open the case and replace the blown fuse with the ratings specified: F 2A/250V (quick acting). CDM-20 Page-22