ABB Drives. Hardware Manual RDCU Drive Control Units

Similar documents
ABB Drives. User s Manual. Pulse Encoder Interface Module RTAC-01

ABB Drives. User s Manual HTL Encoder Interface FEN-31

ACS800. Master/Follower Application Guide Supplement to Firmware Manual for ACS800 Standard Application Program

ACS800 Hardware Manual ACS and ACS800-04M Drive Modules (45 to 560 kw) ACS800-U4 Drive Modules (60 to 600 HP)

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC A - M8 connector

Contents. Document information

Modular I/O System Analog and Digital Interface Modules

38 Series - Relay interface modules A

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q R0001

38 Series - Relay interface modules A

Digital input modules

Power Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1

PCS0100en Persy Control Services B.V. Netherlands

ABB solar inverters. Hardware manual PVS central inverters (100 to 1000 kw)

HMI display Installation Guide

Duct Humidity Transmitter

ZC-24DO CANopen I/O Module: 24 Digital Outputs

SYSTEM 4C. C R H Electronics Design

SYSTEM 45. C R H Electronics Design

IO-RM3 3-Stage Relay Module

Clear Glass Sensor. Ordering Information E3S-CR67/62. Optimum Sensor for Detecting Transparent Glass and Plastic Bottles

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N

Electronic overload relay EF19 and EF45

IO-DIM6 6-Channel, Digital to Analogue Converters

ACS800. Hardware manual ACS (+V992) drives (500 to 2800 kw)

is then retained absolutely without interruption.

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

MCR1900 Media Converter 19-Slot Chassis

38 SERIES. Relay interface modules A. EMR Electromechanical Relays. Common features. SSR Solid State Relays. 6.

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

Control Devices Catalogue. Control Devices. Preferred and Standard Products

Electronic overload relay EF65, EF96 and EF146

Rack mounted telephone- and leased line modem for industrial applications

Product and Applications Description. Application Programs. Example of Operation. GAMMA instabus Technical Product-Information.

MILLENIUM INSTALLATION MANUAL NTR 735 A. Simple Automation Control Module (MAS)

L-LAS-TB-CL serie. laser light curtains for inline measuring tasks

Adjustment functions for both span and shift have been incorporated

TX OPEN RS232/485 module

49 Series - Relay interface modules A. Features

I nstallation. M100Q Series Proportional Actuator with R81Q Controller Board for Thermistor Sensor Applications. Tools Needed.

Multifunction devices

ABB i-bus EIB / KNX Analogue Input AE/S 4.2

Contactless Encoder RI360P0-QR24M0-INCRX2-H1181

HARDWARE MANUAL. Ixx24-A 1/20. Val Controls A/S Limfjordsvej 3 DK-6715 Esbjerg N Tel vc@valcontrols.com

ACS800. Hardware Manual ACS Drive Modules (0.55 to 200 kw) ACS800-U4 Drive Modules (0.75 to 200 hp)

maxon motor maxon motor control EPOS Positioning Controller Cable Starting Set Edition June 2006 part number Positioning Controller

Installation and start-up guide NETA-21 remote monitoring tool

Options for ABB drives, converters and inverters. User s manual FDPI-02 diagnostics and panel interface

Whale 3. User Manual and Installation Guide. DC Servo drive. Contents. 1. Safety, policy and warranty Safety notes Policy Warranty.

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

Product and functional description

SENSORS. Fiber Optic Sensors - S70. Advanced fiber optic amplifiers for high speed and low contrast applications

MCR-VDC-UI-B-DC. Voltage Transducer for DC Voltages. INTERFACE Data Sheet _en_01. 1 Description

MasterINTERFACE 39 Series - Relay interface modules

Electric Rotary Actuator - On/Off or programmable control actuator

Installing the Tracer ZN517 Unitary Controller Ordering number: ,

MasterINTERFACE 39 Series - Relay interface modules

Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2

HSP GmbH Zum Handwerkerhof Wendelstein Tel / Fax: / Web: HSP@hsshsp.de NTG-3000.

Redundancy Module QUINT-DIODE/40

Telephone- and leased line modem for industrial applications TD-36

Liquid Level Limit Switch liquiphant T FTL 20

Install the DeviceNet Module using the following procedure:

Switch Actuator, 8-fold, 10 A, MDRC AT/S , GH Q R0111

Substation Automation Products Relion 670/650 series IEC and ANSI Hardware

48 SERIES Relay interface modules 10 A

pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2, /0.65/0.

ABB i-bus KNX Fan Coil Actuator, MDRC FCA/S 1.1M, 2CDG R0011

AXIS T81B22 DC 30W Midspan

VLT Series 3500 Adjustable Frequency Drive Instruction Manual

80 Series - Modular timers 16 A. Features

Installation manual. Generator Paralleling Controller GPC multi-line C

MINI MCR-SL-R-UI(-SP)

NC-12 Modbus Application

Power Supply, Primary Switch Mode, Narrow Design MINI-PS AC/2x15DC/1

Installation and Start-up Guide. CS 31 Adapter Module NCSA-01

Option field bus: without bus with profibus DP. Design-Index (Subject to change)

LED red (-): Measuring value < lower tolerance threshold LED red (+): Measuring value > upper tolerance threshold. Page 1/6

ST Series POWER SUPPLIES USER INSTRUCTIONS

AXIS 291 1U Video Server Rack Installation Guide

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

Color Mark Sensor with Red or Green LED E3S-VS

MODEL 2202IQ (1991-MSRP $549.00)

DLP-PU/E Instruction Manual

INSTALLATION AND OPERATING INSTRUCTIONS For Model GL1 Gate Locks

Relay mounting systems

Allen-Bradley/Rockwell

TECHNICAL DATASHEET #TD1404AX PWM CONTROLLED SOLENOID DRIVER

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description

SENSORS. Miniature Sensors - S3Z. Advanced line of miniature Asian style of photoelectric sensors mm background suppression

Power Supply, Primary Switch Mode, Narrow Design MINI-PS AC/24DC/2

Description. Dimensions. Features. precision works better

Waveguide Access Point WGA631. Product Guide

OPLC Installation Guide

DVPPF02-H2. PROFIBUS DP Slave Communication Module Application Manual

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

Solid Core and Split Core Adjustable Current Status Switches CSS-O, CSS-C; CSP-O, CSP-C

DMX2PWM 9 Channel Dimmer Setup Manual

Transcription:

ABB Drives Hardware Manual RDCU Drive Control Units

3 RDCU layout Designations A C and J1 refer to the section Mechanical installation below. The connectors (X ) are explained under Technical data further below. A B A X39 X20 X34 C X21 X31 C J1 X22 X32 C X23 X25 X26 X27 X33 X68 X57 C A B A

4 Safety instructions Do not attempt any work on a powered drive. After switching off the mains, always allow the intermediate circuit capacitors 5 minutes to discharge before working on the frequency converter, the motor or the motor cable. It is good practice to check (with a voltage indicating instrument) that the drive is in fact discharged before beginning work. Avoid touching the circuit board (RMIO) inside the RDCU unit in order to minimise the risk of damage caused by static electricity. Do not use excessive force when detaching connectors or removing the cover of the unit. Identifying different types of unit Mechanical installation General Before installation, check that the RDCU unit has the correct application program for the converter hardware in question. There is a label attached to the cover of the RDCU unit that lists SW TYPE, SW CODE and DEVICE TYPE. SW TYPE identifies the application program that is loaded into the RDCU unit. Some of the most common SW TYPE codes are AMXRxxxx (ACS800 System Application Program), ASxRxxxx (ACS800 Standard Application Program), AHxRxxxx (ACS800 Pump Control Application Program), and IxxRxxxx (IGBT Supply Unit Application Program). Check that the application program corresponds to the original order. Check also that the DEVICE TYPE indicated matches that of the converter hardware. The RDCU unit can be mounted on a vertical or horizontal 35 7.5 mm DIN rail. The unit should be mounted so that air can freely pass through the ventilation holes in the housing. Mounting directly above heat-generating equipment should be avoided. WARNING! Avoid installing the RDCU in the immediate vicinity of sources of electromagnetic disturbance, such as relays, contactors, brake choppers and motor cabling. The minimum recommended distance from such components is 500 mm. Installing metallic screening between the unit and the source of disturbance is highly recommended, and may reduce the required distance. The RDCU is grounded to the mounting rail by two screws. Fastening the unit to the mounting rail Note: Set jumper J1 (if necessary; see the Isolation and grounding diagram) before fastening the unit.

5 Setting J1 can be further facilitated by removing the cover (see Removal and replacement of cover below for further instructions). The jumper can also be set using long-nosed pliers or tweezers without removing the cover. Align the four retaining clips (A) at the top and bottom edges of the cover with the mounting rail, and carefully press the module onto the rail until the clips catch on the edges of the rail. Using two screws, fasten the base plate of the RDCU by the two mounting holes (B) to the mounting rail. Make sure the contact surfaces are free from dirt or grease. This is essential for the operation of the control unit since the screws provide the grounding for the unit. Removal of unit from mounting rail Remove the two screws (B) holding the base plate of the unit to the mounting rail. Carefully bend the retaining clips (A) at the upper and lower edges of the cover outwards to release the unit completely from the mounting rail. Removal and replacement of cover Remove all detachable (screw-type) terminal plugs from the RDCU, and disconnect any cables connected to the unit. Remove any optional modules. If desired, the unit can be removed from the mounting rail as described above to facilitate the following steps. With a screwdriver or similar tool, carefully release the four cover retaining clips (C) on the right-hand side while simultaneously pulling the right-hand edge of the cover gently away from the base plate. Shift the cover to the left to free its left-hand edge, then pull it to detach it completely from the base and circuit board. Replace the cover in reverse order to the above (left-hand edge first). If the unit is already mounted onto its mounting rail, align the retaining clips (A) so that they catch on the mounting rail.

6 Wiring General The shields of the I/O cables should be grounded to the chassis of the cubicle as close to the RDCU as possible. Use grommets at all cable entries. Handle fibre optic cables with care. When unplugging fibre optic cables, always grab the connector, not the cable itself. Do not touch the ends of the fibres with bare hands as the fibre is extremely sensitive to dirt. The maximum long-term tensile load for the fibre optic cables included is 1 N; the minimum short-term bend radius is 25 mm (1 ). Digital/Analogue input/output connections See the Firmware Manual of the application program in question. Installation of optional modules Follow the instructions given in the user manual of the module. Other connections See also the wiring diagram below. Powering the RDCU The RDCU is powered through connector X34. The unit can be powered from the power supply board of the inverter (or IGBT supply) module, provided that the maximum current of 1 A is not exceeded. The RDCU can also be powered from an external 24 V DC supply. Note also that the current consumption of the RDCU is dependent on the optional modules attached. (For current consumption of optional modules, see their respective user manuals.) Fibre optic connection to inverter/igbt supply module Connect the PPCS link of the AINT (ACS 800 series modules) board of the inverter (or IGBT supply) module to fibre optic connectors V57 and V68 of the RDCU. Note: The recommended maximum distances for the fibre optic link is 10 m (for plastic [POF] cable). In case longer distances are required, contact an ABB representative.

7 Connection of control panel (CDP 312R) Connect the control panel to X39. RDCU Control Unit X39 RMIO V68 V57 RXD TXD X34 + I 0 CDP 312R control panel V1 V2 9 10 X17 (liquid-cooled drives only) 1 2 R7i/R8i: APOW/X3 AINT 1 A max. (ACS800 Series) IGBT Supply or Inverter Module

8 Technical data General Mounting: Onto 35 7.5 mm DIN mounting rail Housing materials: Zinc-plated steel (base); ABS/PC (cover) Connector types X20 (Constant voltage output): 2-pole detachable screw terminal block* X21 (Analogue I/O): Four 3-pole detachable screw-type terminal blocks* X22 (Digital inputs): One 3-pole and two 4-pole detachable screw-type terminal blocks* X23 (24 VDC output): 2-pole detachable screw-type terminal block* X25-X27 (Relay outputs): Three 3-pole detachable screw-type terminal blocks* X31 (Slot 1), X32 (Slot 2): 38-pin header (female), pitch 2 mm X33 (DDCS): 20-pin header (female), pitch 2.54 mm X34 (24 VDC power input): 3-pole detachable screw-type terminal block* X39 (Control panel): 12-pin header (male), pitch 2.54 mm V57, V68 (PPCS link): Fibre optic transmitter/receiver (10 MBd) *Wire: 0.3 3.3 mm 2 (22 12 AWG). Torque: 0.2 0.4 Nm (2 4 lbf.in.). Pitch: 5.0 mm. Constant voltage output (X20, X21:1) Voltage: +10 VDC, 0, -10 VDC ±0.5% (Full scale range) at 25 C (77 F). Temperature coefficient: ±100 ppm/ C (±56 ppm/ F) max. Maximum load: 10 ma Applicable potentiometer: 1 to 10 kohm Analogue inputs (X21) General: Two programmable differential current inputs (0 ma / 4 ma 20 ma, R in = 100 ohm) and one programmable differential voltage input (-10 V / 0 V / 2 V +10 V, R in = 200 kohm). The analogue inputs are galvanically isolated as a group (see Isolation and grounding below) Isolation test voltage: 500 VAC, 1 min Max. common mode voltage between the channels: ±15 VDC Common mode rejection ratio: > 60 db at 50 Hz Resolution: 0.025% (12 bit) for the -10 V +10 V input, 0.5% (11 bit) for the 0 +10 V and 0 20 ma inputs Inaccuracy: ±0.5% (Full scale range) at 25 C. Temperature coefficient: ±100 ppm/ C max.

9 Analogue outputs (X21) General: Two programmable current outputs: 0 (4) 20 ma, R L < 700 ohm Resolution: 0.1% (10 bit) Inaccuracy: ±1% (Full scale range) at 25 C (77 F). Temperature coefficient: ±200 ppm/ C (±111 ppm/ F) max. Digital inputs (X22) General: Six programmable digital inputs (common ground: 24 VDC, -15% +20%) and a start interlock input (DIIL). Group isolated, can be divided into two isolated groups (see Isolation and grounding below). Thermistor input: 5 ma, < 1.5 kohm 1 (normal temperature), > 4 kohm 0 (high temperature), open circuit 0 (high temperature). Internal supply for digital inputs (+24 VDC) is short-circuit proof. An external 24 VDC supply can be used instead of the internal supply. Isolation test voltage: 500 VAC, 1 min Logical thresholds: < 8 VDC 0, > 12 VDC 1 Input current: DI1 to DI5: 10 ma; DI6: 5 ma Filtering time constant: 1 ms 24 VDC power output (X23) Voltage: 24 VDC ±10%, short-circuit proof Maximum output current: 250 ma (without any optional modules inserted) Relay outputs (X25, X26, X27) General: Three programmable relay outputs Switching capacity: 8 A at 24 VDC or 250 VAC; 0.4 A at 120 VDC Minimum continuous current: 5 ma rms at 24 VDC Maximum continuous current: 2 A rms Isolation test voltage: 4 kvac, 1 min Slot 1 (X31) General: For connection of I/O extension modules (such as RAIO and RDIO), pulse encoder interface (RTAC), or fieldbus adapters (such as RPBA and RMBA) Slot 2 (X32) General: For connection of I/O extension modules (such as RAIO and RDIO) or pulse encoder interface (RTAC) DDCS (X33) General: For connection of RDCO-0x(C) DDCS Communication module

10 24 VDC power input (X34) Voltage: 24 VDC ±10% Typical current consumption (without option modules): 250 ma Maximum current consumption: 1200 ma (with option modules inserted) Pin designations: 1 = not used; 2 = +24 V; 3 = 0 V Control panel connection (X39) General: For connection of CDP-312R control panel PPCS link (V57, V68) General: Optical fibre connection to inverter (or IGBT supply) module Optical component type: 10 MBd Protocol: ABB PPCS (Power Plate Communication System) Jumper J1 LEDs General: See Isolation and grounding below Pitch: 2.54 mm Power : Green; denotes +5 V power OK Fault : Red Ambient conditions Operating temperature: +0 +60 C (32 140 F) Storage temperature: -40 +70 C (-40 +158 F) Applicable standards Immunity: IEC 61800-3 (Limits: Industrial, Second environment); EN 50081-2 (Limits: Industrial) Emission: EN 50081-2 (Limits: Industrial) PELV requirements: The terminals of the RMIO board as well as on the optional modules attachable to the board fulfil the Protective Extra Low Voltage (PELV) requirements stated in EN 50178 provided that the external circuits connected to the terminals also fulfil the requirements.

11 Isolation and grounding X20 1 VREF 2 GND X21 1 VREF 2 GND 3 AI1+ 4 AI1-5 AI2+ 6 AI2-7 AI3+ 8 AI3- Common mode voltage between channels ±15 V (Test voltage: 500 V AC) 9 AO1+ 10 AO1-11 AO2+ 12 AO2- X22 1 DI1 2 DI2 3 DI3 4 DI4 9 DGND Jumper J1 settings: Ground 5 DI5 6 DI6 7 +24V 8 +24V 11 DIIL 10 DGND X23 1 +24 V 2 GND X25 1 RO1 2 RO1 3 RO1 X26 1 RO2 2 RO2 3 RO2 X27 1 RO3 2 RO3 3 RO3 J1 (Test voltage: 4 kv AC) All digital inputs share a common ground. This is the default setting. or Grounds of input groups DI1 DI4 and DI5/DI6/DIIL are separate (isolation voltage 50 V).

12 Dimensions

3AFE 64636324 REV C / EN EFFECTIVE: 22.09.2008 ABB Oy AC Drives P.O. Box 184 FIN-00381 HELSINKI FINLAND Telephone: +358 10 22 11 Fax: +358 10 22 22681 Internet: http://www.abb.com ABB Inc. Drives & Power Products 16250 West Glendale Drive New Berlin, WI 53151 USA Telephone: 262 785-3200 800 243-4384 Fax: 262 780-5135