Ties and Connector Pins Connectors for precast concrete sandwich panels. Version: Peikko Group 06/2015. Technical Manual

Similar documents
Technical handbook Panel Anchoring System

Detailing of Reinforcment in Concrete Structures

TECHNICAL SPECIFICATION SERIES 8000 PRECAST CONCRETE

DESIGN OF SLABS. 3) Based on support or boundary condition: Simply supported, Cantilever slab,

INSTRUCTIONS FOR USE

8 EXTRA LIGHT GRC SANDWICH ELEMENTS FOR ROOFING IN INDUSTRIAL BUILDINGS

Draft Table of Contents. Building Code Requirements for Structural Concrete and Commentary ACI

MultiPost-AP anchorage device

FLOORS REINFORCEMENT Shear Stud Connector for steel- concrete composite structures cold applied by pins

Chapter 5 Bridge Deck Slabs. Bridge Engineering 1

Diameter. Swift Lift Round Recess Plug. Note: The diameter of the narrow recess plug is the same as the diameter of the round recess plug.

EDEXCEL NATIONAL CERTIFICATE/DIPLOMA MECHANICAL PRINCIPLES OUTCOME 2 ENGINEERING COMPONENTS TUTORIAL 1 STRUCTURAL MEMBERS

HPM Rebar Anchor Bolt. For bolted connections. Technical Manual. European Technical Approval ETA-02/0006. Version: Peikko Group 01/2015

PPM High-Strength Anchor Bolt

The following sketches show the plans of the two cases of one-way slabs. The spanning direction in each case is shown by the double headed arrow.

Page 1 of Sven Alexander Last revised SB-Produksjon STATICAL CALCULATIONS FOR BCC 250

BSF and BCC beam connections

Optimising plate girder design

DESIGN OF SLABS. Department of Structures and Materials Engineering Faculty of Civil and Environmental Engineering University Tun Hussein Onn Malaysia

Design of Steel Structures Prof. S.R.Satish Kumar and Prof. A.R.Santha Kumar. Fig some of the trusses that are used in steel bridges

SEISMIC DESIGN. Various building codes consider the following categories for the analysis and design for earthquake loading:

Structural fire design Eurocode Timber structures

Structural Integrity Analysis

Analysis and Repair of an Earthquake-Damaged High-rise Building in Santiago, Chile

Installation guide for the SafeLine type anchorage device. Tested in compliance with EN 795: No.: SE-...

SUPPLEMENTAL TECHNICAL SPECIFICATIONS BI-DIRECTIONAL STATIC LOAD TESTING OF DRILLED SHAFTS

MECHANICS OF SOLIDS - BEAMS TUTORIAL 2 SHEAR FORCE AND BENDING MOMENTS IN BEAMS

CONCRETE FLOOR SLAB & CASTING BED CONSTRUCTION

Formwork for Concrete

ENGINEERING SCIENCE H1 OUTCOME 1 - TUTORIAL 3 BENDING MOMENTS EDEXCEL HNC/D ENGINEERING SCIENCE LEVEL 4 H1 FORMERLY UNIT 21718P

Technical Notes 3B - Brick Masonry Section Properties May 1993

Hanson Building Products. precast basement solutions

50AI01oe 02/15. Labko GRP cesspools. Instructions for installation, operation and maintenance

Preliminary steel concrete composite bridge design charts for Eurocodes

LEGACY REPORT ER ICC Evaluation Service, Inc. Reissued November 1, Legacy report on the 1997 Uniform Building Code

HORIZONTAL INSTALLATION

LEGACY REPORT. (800) (562) A Subsidiary of the International Code Council. *Corrected March 2014

ANCHOR BOLTS FOR NUCLEAR POWER PLANT APPLICATIONS

After reading this lesson you will be able to: 12.3 IMPORTANCE OF ROOF 12.4 TYPES OF ROOF IN A HOUSE

INTERNATIONAL ASSOCIATION OF CLASSIFICATION SOCIETIES. Interpretations of the FTP

Residential Deck Safety, Construction, and Repair

Optimum proportions for the design of suspension bridge

RC Detailing to Eurocode 2

TABLE OF CONTENTS. INTRODUCTION... 5 Advance Concrete... 5 Where to find information?... 6 INSTALLATION... 7 STARTING ADVANCE CONCRETE...

EVALUATION OF SEISMIC RESPONSE - FACULTY OF LAND RECLAMATION AND ENVIRONMENTAL ENGINEERING -BUCHAREST

Best Practice in Best Pra ctice in teel constr uction - onstr industrial B uildings esidential Buildings 01 Introduction 02 Key Design Factors

FORM DESIGN. easy to work with, and generally available.

Design of Steel Structures Prof. S.R.Satish Kumar and Prof. A.R.Santha Kumar

MECHANICS OF SOLIDS - BEAMS TUTORIAL 1 STRESSES IN BEAMS DUE TO BENDING. On completion of this tutorial you should be able to do the following.

Welded Fabric. The CARES Guide to Reinforcing Steels Part 5. Installation of welded fabric on a major contract. 1.0 Introduction

Design rules for bridges in Eurocode 3

Eurocode 4: Design of composite steel and concrete structures

METHOD OF STATEMENT FOR STATIC LOADING TEST

Solid shape molding is not desired in injection molding due to following reasons.

Chapter 2 Basis of design and materials

EDEXCEL NATIONAL CERTIFICATE/DIPLOMA MECHANICAL PRINCIPLES AND APPLICATIONS NQF LEVEL 3 OUTCOME 1 - LOADING SYSTEMS TUTORIAL 3 LOADED COMPONENTS

Design and Construction of Cantilevered Reinforced Concrete Structures

A transverse strip of the deck is assumed to support the truck axle loads. Shear and fatigue of the reinforcement need not be investigated.

The Roskilde Domes 2011 and 2012

Structural Failures Cost Lives and Time

MILMAN & ASSOCIATES STRUCTURAL CONSULTING ENGINEERS/ PROJECT MANAGERS

FREEBIRD THE ORIGINAL D.I.Y. ORNITHOPTER! Tools and Glue. Required Materials

Bending, Forming and Flexing Printed Circuits

If stepping is required, step at 180mm as seen in this picture.

Super Slider ADJUSTABLE FROM Model #HD26229

USE OF CFRP LAMINATES FOR STRENGTHENING OF REINFORCED CONCRETE CORBELS

SECTION 3 DESIGN OF POST- TENSIONED COMPONENTS FOR FLEXURE

EAST LYME HIGH SCHOOL

Dubai Municipality Standard DMS 1: Part 5: 2004

Basics of Reinforced Concrete Design

4B The stiffness of the floor and roof diaphragms. 3. The relative flexural and shear stiffness of the shear walls and of connections.

Schlüter -KERDI-BOARD Substrate, structural panel, bonded waterproofing

FORMWORK INTRODUCTION

Design Manual to BS8110

ADVANCED SYSTEMS FOR RATIONAL SLAB REINFORCEMENT

INTRODUCTION TO BEAMS

Precast Concrete Parking Structures

Joist. Reinforcement. Draft 12/7/02

9.3 Two-way Slabs (Part I)

ICC-ES Evaluation Report

FOOTING DESIGN EXAMPLE

High Strain Dynamic Load Testing of Drilled Shafts

SERIES ASM NEOPRENE/EPMD FLANGED SINGLE SPHERE CONNECTOR CONNECTORS. Pressures to 225 PSIG (15.51 barg) Temperatures to 230ºF (110ºC)

Certificate of shape stability

CHAPTER 9 LONG TERM MONITORING AT THE ROUTE 351 BRIDGE

Aluminium systems profile selection

DIVISION: MASONRY SECTION: MASONRY ANCHORS REPORT HOLDER: HILTI, INC DALLAS PARKWAY, SUITE 1000 PLANO, TEXAS 75024

CERTIFICATE NAME OF PRODUCT MANUFACTURER PRODUCT DESCRIPTION CERTIFICATION PROCEDURE. No VTT C Date of issue , Updated July 1, 2011

Stresses in Beam (Basic Topics)

bi directional loading). Prototype ten story

Cover. When to Specify Intermediate Precast Concrete Shear Walls Rev 4. White Paper WP004

STRUCTURAL CONCEPT FOR LIGHT GAUGE STEEL FRAME SYSTEM

SECTION 3 DESIGN OF POST TENSIONED COMPONENTS FOR FLEXURE

IHSS-N1 WELDED HONEYCOMB CORE SPECIFICATION. Generated: Sergiy Papyshev Engineering. Approved: Don Prysi Manufacturing. Approved: Merzuk Ramic Quality

Precision Miniature Load Cell. Models 8431, 8432 with Overload Protection

STEEL BUILDINGS IN EUROPE. Single-Storey Steel Buildings Part 5: Detailed Design of Trusses

HIGH PERFORMANCE PRE-APPLIED SYSTEM FOR BLIND SIDE & BELOW GRADE WATERPROOFING APPLICATIONS

Detailing of Reinforcement in Concrete Structures

Profiles in stock Standard catalogue. Discover the possibilities with aluminium profiles from Sapa

Fire Preventive and Fireproof Performance Test and Evaluation Procedure Manual

Transcription:

Ties and Connector Pins Connectors for precast concrete sandwich panels Version: Peikko Group 06/2015 Technical Manual

Ties and Connector Pins Connectors for precast concrete sandwich panels Benefits of Ties and Connector Pins Coverage of all thermal insulation thicknesses and materials for the future energy saving constructions Reliable, familiar connectors for precast concrete sandwich panels with over 50 years of usage experience Easy to install between insulation plates Benefi ts of stainless steel Sizes according to insulation thicknesses Beam Tie for low elements and openings Prefabricated products guarantee stable, high-quality, accurate deliveries Provides eff ective workfl ow for the customer Low maintenance, low life-cycle costs Ties and Connector Pins are used to connect the inner and outer layers of precast concrete sandwich panels. Ties and Connector Pins are most commonly used in sandwich panels with insulation thicknesses of 40 390 mm and recommended dimensions up to 3 m high and 7 m wide. Prefabrication allows the use of precise formworks with a high quality of surfaces and dimensions, high repeatability of formwork and production of concrete elements. Production is plan-placed in factory conditions with a controlled indoor environment where the mixing, placing, and curing of the concrete is easy to control. Prefabrication enables sandwich panels to be created with high-quality wall surfaces. www.peikko.com

Contents About Ties and Connector Pins 4 1. Product Properties...4 1.1 Structural behaviour...5 1.2 Application conditions...12 1.3 Other properties...14 2. Resistances...18 Selecting Ties and Connector Pins Annex A - Design curves 19 21 Installation of Ties and Connector Pins 30 Revision: 002

About Ties and Connector Pins 1 PRODUCT PROPERTIES Ties and Connector Pins are bent and welded wire connectors used to connect concrete layers of precast sandwich panels. Ties and Connector Pins are usually uniformly distributed through thermal insulation plates and anchored in both of the layers of a sandwich panel. The product range consists of four types of connector, which are available in several standard models to cover a wide range of precast panel thicknesses: Diagonal Tie PPA Beam Tie PPI Connector Pin PDQ Connector Pin Figure 1. Types of ties and connectors: Diagonal Tie, PPA Beam Tie, PPI/PDQ Connector Pin. The Diagonal Tie is a single lattice girder used to connect the outer and inner layers of sandwich panels. The lattice girder consists of stainless diagonals and flanges made either of stainless or reinforcing steel. The flange material depends on the exposure class and concrete cover of the flanges. PDM Diagonal Tie: both flanges are made of reinforcing steel. The PDM Diagonal Tie is used in cases where concrete cover is adequate for both flanges. PD Diagonal Tie: the outer flange is made of stainless reinforcing steel for cases when the concrete cover in the outer layer is not sufficient. The inner flange of the PD Diagonal Tie is made of reinforcing steel. PDR Diagonal Tie: both flanges are made of stainless reinforcing steel. The PPA Beam Tie is a single connector used in cases where the height of concrete layers does not allow the use of Diagonal Ties (window lintels or low socle elements). The PPA Beam Tie is made of stainless reinforcing steel. PPI and PDQ Connector Pins are single connectors typically used in combination with Diagonal Ties to restrain deformation perpendicular to the outer layer, such as warping. 4 Ties and Connector Pins

About Ties and Connector Pins 1.1 Structural behaviour Ties and Connector Pins are used to provide structural interaction between the concrete layers of sandwich panels and enable the sandwich panel to transfer loads and displacements that are most typically imposed to the structure by the following effects: Lifting and transport Self-weight of concrete layer Shrinkage deformation Wind load Temperature deformation Adhesion of the formwork The structural effects are likely to be combined during the different stages of the life cycle of the precast sandwich panel. The precast panel must be designed to withstand the effects of the most unfavourable load combinations. In the manufacturing stage, the Ties and Connector Pins will be subject to tensile forces resulting from the selfweight of the sandwich panel during lifting and transportation. In normal use cases, Ties and Connector Pins are likely to be exposed to the action of self-weight of the outer layer, shrinkage deformation in the outer and inner layers, and environmental loads such as wind load and deformation of the outer layer due to temperature changes. Self-weight during lifting and transportation. In the manufacturing stage, adhesion between the sandwich panel and the formwork will result in tensile forces in the connectors while the panel is lifted from the formwork. Once the sandwich panel is lifted from the formwork, the tensile forces in the connectors will correspond to the self-weight of the layer that is hanged on them (Figure 2). During the transportation stage, the forces in the connectors due to self-weight must be multiplied due to dynamic effects. Figure 2. Principle of adhesion between concrete and formwork. Lifting Sandwich panel Formwork Adhesion between formwork and surface of outer concrete layer Version: Peikko Group 06/2015 5

About Ties and Connector Pins Figure 3. Force fl ow in Diagonal Ties related to formwork adhesion.,y α,y Adhesion + Weight of bottom concrete layer Inner layer,y,y,y,y 25 mm Adhesion + Weight of bottom concrete layer Self-weight of the concrete layer The outer layer of the sandwich panel is most typically hanged on the inner layer (Figure 4). The self-weight of the outer layer acts as a dead load and generates vertical forces G d in the sandwich panel. These vertical forces are resisted by the tensile resistance of diagonals and compression resistances of the thermal insulation layer (Figure 4). Figure 4. Forces resulting from the eff ects of dead load.,y,y Inner layer α G d Compression zone in insulation layer Reinforcement of inner layer α G d 6 Ties and Connector Pins

About Ties and Connector Pins Shrinkage deformation Shrinkage is a time-dependent deformation of concrete that is mainly influenced by the properties of the precast element (material, dimensions) and humidity of the precast element and surrounding environment. The outer and inner layers of the sandwich panels usually have a different thickness and are exposed to environments with different humidity. As a result, they are subjected to different shrinkage deformations. Diagonal Ties are used to ensure the compatibility of shrinkage deformations and prevent interface slip between the two concrete layers of the sandwich panel (see Figure 5). A humidity gradient also exists within the inner and outer side of each concrete layer of the precast element (Figure 6). This is mainly due to the fact that the evaporation of water is faster on the side of the layer that is exposed to the external environment compared to the side that is in contact with the thermal insulation layer. The difference between shrinkage strains that is related to this humidity gradient may cause local deformations of the sandwich panel (Figure 6). These deformations may be prevented placing Diagonal Ties or Connector Pins around the edges of the sandwich panel (Figure 6). Figure 5. Linear shrinkage deformation in sandwich panel. Reinforcement of inner layer 25 mm Δε shr,il Δε shr,ol,y,y Tension diagonal 90% RH α 50% RH Inner layer 80% RH Shrinkage Shrinkage deformation in inner layer α Tension diagonal Shrinkage deformation in outer layer,y Version: Peikko Group 06/2015 7

About Ties and Connector Pins Reinforcement of the inner concrete layer restricts the effects of flexural shrinkage deformation, which nullifies this effect on the Diagonal Ties. Diagonal Ties are then loaded by flexural shrinkage deformation from the outer concrete layer. Figure 6. Shrinkage fl exural deformation at the end on the outer concrete layer. Δε shr,il,1 Δε shr,ol,1 Shrinkage deformation M shr,ol α R shr,a M shr,ol Δε shr,il,2 Δε shr,ol,2,y 90% RH 50% RH Inner layer Inner layer Inner layer 80% RH,y α Wind load The outer layer of the sandwich panel may be exposed to wind action, which usually acts as a uniform pressure or suction load perpendicular to the panel surface. Uniform pressure load is transferred from the outer concrete layer via the insulation layer to the inner layer and supports. For this reason, the thermal insulation must have adequate compression strength. The tension loads caused by suction are resisted by diagonals (see Figure 7). In both cases, wind load will result in the sandwich panel bending. 8 Ties and Connector Pins

About Ties and Connector Pins Figure 7. Transfer of wind suction to inner layer. 25 mm Figure 8. Transfer of wind pressure to inner layer. 25 mm,y,y,y α,y,y Wind suction,y Inner layer Figure 9. Seasonal temperature gradient in sandwich panel. Inner layer Wind suction Wind pressure +T out Summer temperature gradient +T int +T int Winter temperature gradient +T out Version: Peikko Group 06/2015 9

About Ties and Connector Pins Temperature deformation As a building envelope, the sandwich panel is exposed to frequent temperature changes during day and night and during different seasons. An example of the temperature flow in a sandwich panel is shown in Figure 9. Since the temperature variations in the inner layer of the sandwich panel (inside the building) are assumed to be relatively low, the temperature gradient of the sandwich panel principally depends on the daily or annual temperature fluctuation in the outer layer. Linear temperature deformation causes extension (during summer) and contraction (during winter) of the outer concrete layer. Diagonal Ties are used to resist the deformations of the outer concrete layer and prevent movement differences between layers of sandwich panels (Figure 10). Figure 10. Force fl ow during summer and winter season in sandwich panel. 25 mm 25 mm Reinforcement of inner layer,y,y,y α α,y α Temperature deformation T i = 20 C Inner layer α T e,max Temperature deformation during summer Temperature deformation Reinforcement of inner layer,y T i = 20 C Inner layer T e,min Temperature deformation during winter A certain temperature gradient exists also through the depth of each concrete layer. This temperature gradient may result in local deformations of the concrete layers. The orientation of deformation depends on the season and ambient temperature (see Figure 11). Such local bending may be prevented by placing Diagonal Ties or Connector Pins near the edges of the precast panel (Figure 12). 10 Ties and Connector Pins

About Ties and Connector Pins Figure 11. Annual temperature deformation of a sandwich panel. Diagonal Tie Diagonal Tie Summer temperature deformation Winter temperature deformation Figure 12. Temperature fl exural deformation in the outer layer during winter. M temp,ol R temp,a M temp,ol R temp,a a,y T e = T e - 5 C T e,min T e = T e - 5 C,y α R temp,b b T e,min Inner layer Inner layer Inner layer Inner layer Temperature deformation Version: Peikko Group 06/2015 11

About Ties and Connector Pins 1.2 Application conditions The Ties and Connector Pins were developed for use in precast sandwich panels assuming the following limitations: Recommended maximum dimensions of the precast panel: 3 x 7 m Minimum concrete grade in accordance with Table 1 Minimum anchorage depth in accordance with Table 1 Recommended minimum thickness of outer concrete layer: 70 mm Recommended minimum mesh reinforcement of outer concrete layer: 133 mm2/m (when d ol 70 mm) Recommended minimum edge reinforcement of inner concrete layer: Ø8 (see Figure 13) Design of transverse Diagonal Ties if panel is rotated during lifting (see Figure 14) Uniform casting of top concrete layer to avoid local differences in thickness and compression of thermal insulation The use of plasticizer is recommended to reduce the water-to-cement (w/c) ratio Figure 13. Placement of the edge reinforcement in the inner layer. L max = 7 m Edge reinforcement Ø8 Inner concrete layer l o l o Diagonal Tie Edge reinforcement Reinforcement mesh Diagonal Tie Inner layer H max = 3 m l o is calculated according to EN 1992-1-1 d lbl d Til d ol 12 Ties and Connector Pins

About Ties and Connector Pins Figure 14. Using transverse Diagonal ties during lifting. Lifting Transverse Diagonal Tie Lifting A A Diagonal Tie Transverse Diagonal Tie Lifting anchor A-A Inner layer Diagonal Tie Lifting anchor The minimum anchorage depth and material properties of concrete in accordance with Table 1 must be secured to provide proper functioning of Ties and Connector Pins. Table 1. Concrete cover of Ties and Connector Pins with minimum concrete grades. Diagonal Tie PPA Beam Tie Connector Pins C o C u C o C u C o C u PPI PDQ C o C u Type of connector Anchorage depth (c o /c u ) Minimum concrete grade (Anchorage point of view) Diagonal Tie 25/25 20/25* PPA Beam Tie 35/35 20/25 PPI Connector Pin 40/50 25/30 PDQ Connector Pin 50/40 25/30 *Minimum compressive strength of concrete before stripping from the formwork is f ck = 16MPa. Version: Peikko Group 06/2015 13

About Ties and Connector Pins 1.3 Other properties The dimensions of standard models of Ties and Connector Pins are summarized in Table 2, Table 3, and Table 4. Table 2. Dimensions of Diagonal Tie. c/c c/c Ø5 l Tie Internal flange hø5 α Ø5 External flange Diagonal Diagonal Tie model h 1) c/c Recommended insulation Length 2) α Weight thickness [mm] [mm] [mm] [mm] [deg] [kg] PD/PDM/PDR 100 100 40 23 1.17 PD/PDM/PDR 120 120 60 26 1.18 PD/PDM/PDR 140 140 80 29 1.19 PD/PDM/PDR 150 150 90 31 1.20 PD/PDM/PDR 180 180 120 35 1.22 PD/PDM/PDR 200 200 140 38 1.23 PD/PDM/PDR 210 210 150 39 1.27 PD/PDM/PDR 220 220 160 40 1.27 PD/PDM/PDR 240 240 180 42 1.27 PD/PDM/PDR 260 260 200 44 1.28 300 2400 PD/PDM/PDR 280 280 220 46 1.30 PD/PDM/PDR 300 300 240 48 1.32 PD/PDM/PDR 320 320 260 50 1.34 PD/PDM/PDR 340 340 280 52 1.36 PD/PDM/PDR 360 360 300 53 1.38 PD/PDM/PDR 380 380 320 55 1.40 PD/PDM/PDR 400 400 340 56 1.42 PD/PDM/PDR 420 420 360 57 1.44 PD/PDM/PDR 440 440 380 58 1.46 PD/PDM/PDR 450 450 390 59 1.47 1) The standardized height h of ties is based on anchorage depths 30 + 30 mm into the concrete layers. Dimension h is measured from the central axis to the central axis of flanges. 2) The standard length of Diagonal Ties l Tie is 2400 mm. Ties can be manufactured in multiples of 300 mm. 14 Ties and Connector Pins

About Ties and Connector Pins Table 3. Dimensions of PPA Beam Tie. Ø5 External flange Ø5 α 2 h Diagonal α 1 Ø5 l Internal flange Beam Tie model h l Recommended insulation α 1 α 2 Weight thickness [mm] [mm] [mm] [deg] [deg] [kg] PPA 150 150 90 59 23 0.16 PPA 180 180 120 63 20 0.17 PPA 200 200 140 65 18 0.18 PPA 210 210 150 66 17 0.18 250 PPA 220 220 160 67 16 0.19 PPA 240 240 180 69 15 0.20 PPA 260 260 200 70 14 0.21 PPA 280 280 220 71 13 0.21 PPA 300 300 240 67 15 0.24 PPA 320 320 300 260 68 14 0.25 PPA 340 340 280 69 13 0.25 PPA 360 360 300 65 14 0.28 PPA 380 380 350 320 66 13 0.28 PPA 400 400 340 67 13 0.29 PPA 420 420 360 65 15 0.32 PPA 440 440 400 380 66 14 0.33 PPA 450 450 390 66 14 0.33 Version: Peikko Group 06/2015 15

Ø4 About Ties and Connector Pins Table 4. Dimensions of PPI and PDQ Connector Pins. PDQ PPI 62 60 l pin l pin 45 Connector Pin model Recommended insulation thickness Weight l 3) pin 90 angle installation 45 angle installation PPI PDQ (PPI & PDQ) (PPI) [mm] [mm] [mm] [mm] [mm] PPI/PDQ 170 170 80-0.03 0.05 PPI/PDQ 190 190 100-0.03 0.05 PPI/PDQ 210 210 120-0.03 0.06 PPI/PDQ 230 230 140 80 0.03 0.06 PPI/PDQ 250 250 160 100 0.03 0.06 PPI/PDQ 280 280 190 120 0.04 0.07 PPI/PDQ 300 300 210 140 0.04 0.07 PPI/PDQ 320 320 230 160 0.04 0.08 PPI/PDQ 340 340 250 170 0.04 0.08 PPI/PDQ 360 360 270 190 0.04 0.09 PPI/PDQ 380 380 290 200 0.05 0.09 PPI/PDQ 400 400 310 210 0.05 0.09 PPI/PDQ 420 420 330 230 0.05 0.10 PPI/PDQ 440 440 350 240 0.05 0.10 PPI/PDQ 450 450 360 250 0.05 0.10 3) Length of Connector Pins can be manufactured in multiples of 10 mm. 16 Ties and Connector Pins

About Ties and Connector Pins Manufacturing tolerances Tie length Tie width Diagonal or cross bar distance Diagonal s straightness between bars Connector Pin length ± 10 mm ± 5 mm ± 5 mm ± 2 mm ± 5 mm Materials Types of connectors Type of steel Standard Diagonal Ties Diagonals 1.4301 (smooth) EN 10088-2 Flanges B500B (ribbed) B600KX (ribbed) EN 10080 SFS 1259 PPA Beam Tie B600KX (ribbed) SFS 1259 PDQ/PPI Connector Pin B600KX (ribbed) SFS 1259 Figure 15. Marking of the stainless fl anges The material properties of the flanges of the Diagonal Tie depend on the environment exposure class and concrete cover of the flange (Table 5). Stainless diagonals and flanges may be identified by yellow painting at both ends of the bar (see Figure 15). Table 5. Material options of fl anges of Diagonal Ties. Type PDM PD PDR Structural part External flange Diagonal Internal flange External flange Diagonal Internal flange External flange Diagonal Internal flange Material B500B B600KX 1.4301 x X x x X x x X x Version: Peikko Group 06/2015 17

About Ties and Connector Pins Diagonals are mechanically bent and welded to flanges by using a resistance welding process. The lattice girder is cut mechanically to the correct length. The Connector Pins are cut and bent mechanically. Each package of Ties bears the mark of Inspecta Certification, the emblem of Peikko Group, the type and quality of the product and the manufacturing date. Package sizes: Connector Pins: 500pcs, Diagonal Ties: 500 900pcs, and PPA Beam Ties: 240 500pcs. Peikko Group units are externally controlled and periodically audited on the basis of production certifications and product approvals by various organizations, including Inspecta Certication, VTT Expert Services, Nordcert, SLV, TSUS, and SPSC among others. 2 Resistances The resistances of Ties and Connector Pins are determined by a design concept that makes reference to the following standards: EN 1992-1-1:2004/AC:2010 EN 10080:2005 The tensile resistance of one single diagonal in a Diagonal Tie is given in Table 6. The characteristic value of the tensile resistance is defined as the minimum of the steel resistance of the diagonal, the welding joint resistance between the diagonal, or the anchorage resistance of the diagonal into concrete. The resistances of PPI/PDQ Connector Pins and PPA Beam Ties are given in Table 7 and Table 8. The load bearing direction of the sandwich panel connectors is shown in Table 9. Table 6:.Resistance of Diagonal Ties. Design value Tension resistance of Diagonal Ties 5.6 Table 7. Resistance of PPI and PDQ Connector Pins. Design value Tension resistance of PPI/PDQ Connector Pins 3.5 Table 8. Resistance of PPA Beam Ties. Design value V Rd Shear resistance of PPA Beam Ties 1.1 Table 9. Load bearing direction of the sandwich panel connectors. V Rd PPI PDQ Diagonal Tie PPA Beam Tie PPI and PDQ Connector Pins 18 Ties and Connector Pins

Selecting Ties and Connector Pins The height (h dimension) of the Tie is selected according to the insulation thickness and required anchoring depth. The recommended height for the Tie is the insulation thickness plus the concrete cover (c u + c o ) for anchoring (see Table 1, Table 2, and Table 3). The horizontal edge distance R (see Figure 16) must be 100 300 mm. The vertical distance V (see Figure 16) from the upper and bottom edges should be c min,dur V 200 mm, where c min,dur is determined according to EN 1992-1-1. The c/c spacing of the ties is typically the same as the width of the thermal insulation panels to simplify assembly and minimize wastage. The recommended c/c spacing is 100 600 mm. In narrow spaces such as columns (width of column zone 300 600 mm), it is recommended to use two ties to eliminate the risk of the column buckling (see Figure 16). Figure 16. Placement of the Ties in the panel. R c/c c/c c/c c/c c/c R V S R R H V l Tie Diagonal Tie Diagonal Tie min 100 mm L V V c/c S The spacing rules for PPA Beam ties are identical to those of Diagonal Ties. Diagonal Ties should be placed near the horizontal edges of the panel (R 100 mm) to prevent deformations of the panel edges due to temperature and shrinkage effects. Connector Pins may be used instead of Diagonal Ties (see Figure 16). The edge distance of pins must be S 150 mm (see Figure 16). Pins may be installed perpendicular to the concrete layer of the panel or at a 45 angle. For panels within the scope of application defined in part 1.2 of this technical manual, it is recommended that the resistance of the Diagonal Ties be verified with regard to the effects of structural actions using the interaction curves in Annex A. After selecting the dimension and model of Ties or Connector Pins, a product code describing the product may be defined according to the description in Figure 17, Figure 18, and Figure 19. Please use this code when ordering the product from Peikko s Sales Service. Version: Peikko Group 06/2015 19

Selecting Ties and Connector Pins Figure 17. Product code of Diagonal Ties. Type of flanges PD 260-2100 Length of Diagonal Tie Height of Diagonal Tie Figure 18. Product code of PPA Beam Ties. Type of Beam Tie PPA 260 Height of Beam Tie Figure 19. Product code of Connector Pins Type of Connector Pin PPI 160 Height of Connector Pin 20 Ties and Connector Pins

Annex A - Design Curves The design curves may be used to verify the resistance of Diagonal Ties in sandwich panels with a scope of application as defined in part 1.2 (Application conditions) of this technical manual. Additional application conditions are defined separately for each design curve. The following design example is used to illustrate the use of design curves. Properties of sandwich panel Length of the panel 5700 mm Height of the panel 2500 mm Thickness of the inner layer 140 mm Thickness of the thermal insulation layer 120 mm Thickness of the outer layer 80 mm Spacing of the Ties 600 mm Concrete grade of the outer layer C30/37 Concrete grade of the inner layer C30/37 Thermal insulation Mineral wool Environment class XC4 Reinforcing mesh in the outer layer 150x150 - Ø6 (as=188 mm2/m) Loads: Wind suction: -0.5kN/m2 Maximum temperature of the outer layer 82 C Minimum temperature of the outer layer -30 C Adhesion of the formwork 2kN/m2 Dynamic factor during transportation 2.5 The properties and loads of the sandwich panel fulfil the conditions of the design curve on page 25. Placing of Diagonal Ties in sandwich panel. 2500 50 2400 V=50 R=150 5700 9 x 600 mm 150 Verifi cation for the resistance of the Diagonal. H = 2.5 m Example 1 40 90 140 190 240 290 340 390 d Til [mm] Minimum concrete cover of reinforcement for exposure class XC4 is c min,dur = 25 mm Concrete grade of outer layer doesn t fulfil requirements for environment class XC4, stainless steel shall be used in outer layer. Selection of Diagonal Tie height h: d Til + c u + c o = 120 + 25 + 25 = 170 mm standardized height h of Diagonal Tie 180 (concrete cover 30 mm) Outer concrete cover c o,out = 80-30 - Ø5/2-2 x Ø6 = 35 mm > c min,dur Unfavourable placing of mesh reinforcement is assumed. Selection of PD Diagonal Tie length: Maximum Tie length minimum edge distance V min = cmin,dur l Tie,max = H - 2 x V min = 2500-2 x 30 = 2440 mm round down to a multiple of 300 mm l Tie = 2400 mm Verification of vertical edge distances V = (H - l Tie ) / 2 = (2500-2400) / 2 = 50 mm OK, distance V is in interval c min,dur V 200 mm Selected model of Diagonal Ties: PD 180-2400 Version: Peikko Group 06/2015 21

Annex A - Design Curves Application conditions of the design curve Design boundaries: Concrete grade: C30/37 Thickness of outer layer: 80 mm Spacing of Diagonal Ties: 400 mm Maximal surface temperature: 70 C Temperature gradient: ΔT= ±5 C Wind suction: -0.6kN/m2 Adhesion of formwork: 2kN/m2 Dynamic factor: 2.5 Minimum surface temperature of outer concrete layer: -30 C -40 C L - Length of the panel H - Height of the panel d Til - Thickness of thermal insulation L H = 2 m d Til [mm] H d Til H = 2.5 m d Til [mm] H = 2.75 m d Til [mm] H = 3 m d Til [mm] H = 3.2 m d Til [mm] 22 Ties and Connector Pins

Annex A - Design Curves Design boundaries: Concrete grade: C30/37 Thickness of outer layer: 80 mm Spacing of Diagonal Ties: 600 mm Maximal surface temperature: 70 C Temperature gradient: ΔT= ±5 C Wind suction: -0.6kN/m2 Adhesion of formwork: 2kN/m2 Dynamic factor: 2.5 Minimum surface temperature of outer concrete layer: -30 C -40 C L - Length of the panel H - Height of the panel d Til - Thickness of thermal insulation L H = 2 m 7200 6700 6200 5700 5200 4700 4200 3700 3200 d Til [mm] H d Til H = 2.5 m d Til [mm] H = 2.75 m d Til [mm] H = 3 m 3500 2500 d Til [mm] H = 3.2 m d Til [mm] Version: Peikko Group 06/2015 23

Annex A - Design Curves Design boundaries: Concrete grade: C30/37 Thickness of outer layer: 80 mm Spacing of Diagonal Ties: 400 mm Maximal surface temperature: 80 C Temperature gradient: ΔT= ±5 C Wind suction: -0.6kN/m2 Adhesion of formwork: 2kN/m2 Dynamic factor: 2.5 Minimum surface temperature of outer concrete layer: -30 C -40 C L - Length of the panel H - Height of the panel d Til - Thickness of thermal insulation L H = 2 m d Til [mm] H d Til H = 2.5 m H = 2.75 m H = 3 m H = 3.2 m 24 Ties and Connector Pins

Annex A - Design Curves Design boundaries: Concrete grade: C30/37 Thickness of outer layer: 80 mm Spacing of Diagonal Ties: 600 mm Maximal surface temperature: 82 C Temperature gradient: ΔT= ±5 C Wind suction: -0.6kN/m2 Adhesion of formwork: 2kN/m2 Dynamic factor: 2.5 Minimum surface temperature of outer concrete layer: -30 C -40 C L - Length of the panel H - Height of the panel d Til - Thickness of thermal insulation L H = 2 m 3500 H d Til H = 2.5 m H = 2.75 m H = 3 m 3500 2500 H = 3.2 m Version: Peikko Group 06/2015 25

Annex A - Design Curves Design boundaries: Concrete grade: C30/37 Thickness of outer layer: 80 mm Spacing of Diagonal Ties: 400 mm Maximal surface temperature: 70 C Temperature gradient: ΔT= ±5 C Wind suction: -0.8kN/m2 Adhesion of formwork: 2kN/m2 Dynamic factor: 2.5 Minimum surface temperature of outer concrete layer: -30 C -40 C L - Length of the panel H - Height of the panel d Til - Thickness of thermal insulation L H = 2 m H d Til H = 2.5 m H = 2.75 m H = 3 m 3000 H = 3.2 m 26 Ties and Connector Pins

Annex A - Design Curves Design boundaries: Concrete grade: C30/37 Thickness of outer layer: 80 mm Spacing of Diagonal Ties: 600 mm Maximal surface temperature: 70 C Temperature gradient: ΔT= ±5 C Wind suction: -0.8kN/m2 Adhesion of formwork: 2kN/m2 Dynamic factor: 2.5 Minimum surface temperature of outer concrete layer: -30 C -40 C L - Length of the panel H - Height of the panel d Til - Thickness of thermal insulation L H = 2 m H 3500 2500 d Til H = 2.5 m 3500 H = 2.75 m 3500 2500 H = 3 m 3500 2500 H = 3.2 m Version: Peikko Group 06/2015 27

Annex A - Design Curves Design boundaries: Concrete grade: C30/37 Thickness of outer layer: 80 mm Spacing of Diagonal Ties: 400 mm Maximal surface temperature: 82 C Temperature gradient: ΔT= ±5 C Wind suction: -0.8kN/m2 Adhesion of formwork: 2kN/m2 Dynamic factor: 2.5 Minimum surface temperature of outer concrete layer: -30 C -40 C L - Length of the panel H - Height of the panel d Til - Thickness of thermal insulation L H = 2 m H d Til H = 2.5 m H = 2.75 m H = 3 m 3000 H = 3.2 m 28 Ties and Connector Pins

Annex A - Design Curves Design boundaries: Concrete grade: C30/37 Thickness of outer layer: 80 mm Spacing of Diagonal Ties: 600 mm Maximal surface temperature: 82 C Temperature gradient: ΔT= ±5 C Wind suction: -0.8kN/m2 Adhesion of formwork: 2kN/m2 Dynamic factor: 2.5 Minimum surface temperature of outer concrete layer: -30 C -40 C L - Length of the panel H - Height of the panel d Til - Thickness of thermal insulation L H = 2 m H 3500 2500 d Til H = 2.5 m 3500 H = 2.75 m 3500 2500 H = 3 m 3500 2500 H = 3.2 m For panels outside of the scope of application defined in part 1.2 of the technical manual, a customized design may be made by Peikko s Customer engineering service. Version: Peikko Group 06/2015 29

Installing Ties and Connector Pins Ties The Ties are installed into fresh concrete in turns with insulation panels. This ensures that the correct required anchoring of the tie occurs in the lower concrete panel. Ties must not be inserted through the insulation. The designed anchoring depth (see Table 1) of the Ties must stay above the insulation. The insulation panel is installed tightly against the tie so that there is no gap around the tie. If hard insulation materials are being used, diagonals create a gap between the insulation panels. The gap must be filled with a material such as PU foam before the top concrete layer is cast (see Figure 21). The fill material cannot be of an expanding type. Thin plates of soft thermal insulation (20 mm) could be placed between hard insulation plates and ties instead of PU foam (see Figure 22). The standard length of Diagonal Ties is 2400 mm. Multiple Diagonal Ties may be placed in one row without splicing (see Figure 20). Figure 20. Installation of Diagonal Ties. Figure 21. Filling the gaps of hard insulation. Figure 22. Soft thermal insulation between hard thermal insulation Diagonal Tie Soft thermal insulation Hard thermal insulation Connector Pins Figure 23. Concrete cover of Diagonal Ties in the inner layer. The waved end of PPI Connector Pins is pushed straight through the insulation into the fresh concrete layer. During installation, the pin is moved back and forth to cause the concrete to compact around the pin. The hooked loop of the pin is installed so that the mesh reinforcement bar will be in the pin s loop. The PDQ Connector Pin is hung on the reinforcing mesh of the outer layer (see Figure 24). During installation of the thermal insulation, it is advisable to cut insulation at the position of the pins. The waved end is anchored to the inner layer by the minimum anchorage length (see Table 1).

Installing Ties and Connector Pins The Pin is installed in the inclined direction with an installing jig (wooden block with 45 angle cut) to ensure the correct installation angle (see Figure 25). If hard insulation material and greater thicknesses make it difficult to install the Pins, pre-drilling small holes for the Pins is recommended. Figure 24. Installing of PDQ Connector Pin. Figure 25. Installation of incline Connector Pin.

PEIKKO GROUP CORPORATION Peikko Group Corporation is a leading global supplier of concrete connections and composite structures. Peikko s innovative solutions make the customers building process faster, easier and more reliable. Peikko has subsidiaries in over 30 countries in Asia-Pacific, Europe, the Middle East, and North America, with manufacturing operations in 9 countries. Our aim is to serve our customers locally with leading solutions in the field in terms of quality, safety, and innovation. Peikko is a family-owned and run company with over 1200 professionals. Peikko was founded in 1965 and is headquartered in Lahti, Finland. Peikko Group - Concrete Connections since 1965