What's New in STEP 7 Lite V3.0

Similar documents
FAQ about Control Systems

6ES BE01-0AB0 6ES BE01-0AB0

SIMATIC S It s the Interplay that makes the difference. Siemens AG All Rights Reserved.

Training Document for Comprehensive Automation Solutions Totally Integrated Automation (T I A) MODUL E04

Training Document for Comprehensive Automation Solutions Totally Integrated Automation (T I A) MODULE A5 Programming the CPU 314C-2DP

CPUs - CPU PN/DP

Optimize your simple machines... Modicon M218 Selection Guide

6ES7314-6CG03-0AB0. Supply voltages Rated value 24 V DC Yes permissible range, upper limit (DC) circuit breaker type B, min. 4 A

CPU PN/DP. Function

S7-1500/S7-1500F Technical Data

Training Document for Comprehensive Automation Solutions Totally Integrated Automation (T I A) MODULE E05

6ES7313-5BF03-0AB0. Supply voltages Rated value 24 V DC Yes permissible range, upper limit (DC) circuit breaker type B, min. 4 A

SOFTLINK 300. CPU Specifications. Reference Manual

SIMATIC S7-200 PRICE LIST

Micro800 Programmable Controllers. Bulletin 2080 Selection Guide

SIMATIC S /2 Introduction Function modules (continued) 4/4 Central processing units 4/38 SIPLUS central processing units 4/40 Digital modules

S7-1500/S7-1500F Technical Data

Zlinx Wireless I/O. Peer-to-Peer and Modbus I/O B&B ELECTRONICS PRODUCT INFORMATION

Modular I/O system Rugged Modular I/O System Solutions EN certified for railway applications

S7-400H SIMATIC. Fault-tolerant systems S7-400H. Preface 1 Fault-tolerant automation systems. S7-400H setup options 3.

Applications & Tools. Configuration and Diagnostics of a PROFINET IO System. PROFINET IO Configuration Example. Application Description January 2010

Produktnr. Navn Salgspris ekskl. moms

Data sheet SLIO CPU 015 (015-CEFPR00)

How-To-Do. Hardware Configuration SLIO CPU 014

SIMATIC NET. CP AS-Interface Master B C. Preface Contents. Technical Description and Installation Instructions Interface to the User Program

SIMATIC S7-300, CPU 315-2DP CPU WITH MPI INTERFACE INTEGRATED 24 V DC POWER SUPPLY 128 KBYTE WORKING MEMORY 2

Siemens AG /42 Analog modules 3/42 EM 231 3/42 EM 232 3/42 EM 235 3/47 EM 231 thermocouple module 3/49 EM 231 RTD module

Automation Unit TM 1703 ACP Flexible automation and telecontrol

SCADA and Monitoring for Solar Energy Plant

AUSTRALIAN RAIL TRACK CORPORATION

SIMATIC S Basic Controller in the TIA Portal

How to use KEPServerEX OPC Server (Kepware) with iologik 4000 (Modbus TCP/IP NA-4010 and Modbus Serial NA-4020/NA-4021)

1 Application Description Objective Goals... 3

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

S and STEP 7 Basic V10.5

Profibus DP Network with DeltaV/EMERSON Digital Automation System and Ponto Series Remote I/O

SIMATIC. Automation System S7-400H Fault-tolerant Systems. Preface, Contents. Fault-Tolerant Programmable Logic Controllers 1

SIMATIC HMI SIMATIC S Machine Interface. for internal use only. Automation and Drives SIMATIC S7-200

PROFINET IRT: Getting Started with The Siemens CPU 315 PLC

CPU PN/DP: Configuring an ET. 200S as PROFINET IO device SIMATIC. PROFINET CPU PN/DP: Configuring an ET 200S as PROFINET IO device

M2M/IoT Solutions.

Bellplast S.R.L. Informe del Dpto. Técnico

SIMATIC NET. S7-CPs for Industrial Ethernet. CP Lean. Manual Part B8. Version 1 or higher (Firmware Version V1.0) for SIMATIC S7-300 / C7-300

The goal is to program the PLC and HMI to count with the following behaviors:

Analog Inputs and Outputs

MSITel provides real time telemetry up to 4.8 kbps (2xIridium modem) for balloons/experiments

SOLARCARE SERIES PRODUCT AND APPLICATION GUIDE

Digital I/O: OUTPUT: Basic, Count, Count+, Smart+

SIMATIC. PROFINET IO Getting Started: Collection. CPU PN/DP: Configuring PROFINET interface X2

Web Datalogger. Unit RS232C. General-purpose modem RS485. IP address search screen

OPTICAL FIBER repeaters/ isolators

How many high-speed counters (HSCs) are provided by the SIMATIC S PLC? SIMATIC S FAQ March Service & Support. Answers for industry.

Programmable Controller G Series. New. Models

How to use Citect (SCADA) with iologik 4000 (Modbus TCP/IP NA-4010 and Modbus Serial NA-4020/NA-4021)

Main Catalog 2012/2013 for specialists in automation and control technology

WEA-Base. User manual for load cell transmitters. UK WEA-Base User manual for load cell transmitters Version 3.2 UK

Specifications for EM VDC 4 In/4 Out and EM VDC 4 In/4 Relay Out

[F/T] [5] [KHz] [AMP] [3] [V] 4 ) To set DC offset to -2.5V press the following keys [OFS] [+/-] [2] [.] [5] [V]

SIMATIC. S7-300 Programmable Controller Installation and Hardware. Preface, Contents. Product Overview 1. Mechanical Configuration 2

TYPE APPROVAL CERTIFICATE

SIMATIC. ET 200S distributed I/O Digital electronic module 8DO DC24V/0.5 A (6ES7132-4BF00-0AA0) Preface. Properties 1. Diagnostics 2.

CPU systron S S S 250c. systron S S S 250c. CPUs to the process modules. Stand-alone PLC

PCS0100en Persy Control Services B.V. Netherlands

Programmable set for Ethernet Modbus/TCP in IP20 TI-BL20-PG-EN-8

Digital Expansion Modules Specifications

Siemens AG /56 Digital modules 6/56 SM 421 digital input module 6/59 SM 422 digital output module

Ponto Series. A new concept for automation

Impulse G+/VG+ Series 3, 24 VDC Interface Card Terminal Designations

Using the WAGO PROFINET Coupler as Remote I/O with a Siemens S7 PLC

SCADAPack 530E 535E. remote Programmable Automation Controller

Workshop PROFINET in Process Automation. Intern / Siemens AG Alle Rechte vorbehalten.

Part 1: User information SIMATIC ET 200B Distributed I/O Station Manual Part 2: Reference information Appendices EWA 4NEB c Edition 04

Freelance Distributed process control system System description

Cover sheet. Consistent Data. PROFIBUS DP and PROFINET IO. FAQ September Service & Support. Answers for industry.


GW-7552 PRIFIBUS/MODBUS GATEWAY

CPU ARM926EJ-S, 200MHz. Fast Ethernet 10/100 Mbps port. 6 digital input 2 digital open-drain alarm output

Overview and Applications of PROFINET. Andy Verwer Verwer Training & Consultancy Ltd

SIMATIC. STEP 7 From S5 to S7. Preface, Contents Part 1: Planning Your Conversion. Introduction. Hardware. Converter Manual.

CANtrol EC Modular Control System Powerful and versatile

Modicon M340 Peripheral Remote I/O Adapter BMX PRA 0100 User Manual

Electronic Control Devices The European Product Catalogue 2007

DI 16x24VDC HF Digital Input Module (6ES7521-1BH00-0AB0) SIMATIC. S7-1500/ET 200MP DI 16x24VDC HF Digital Input Module (6ES7521-1BH00-0AB0) Preface

Bristol ControlWave Redundant Control

ABB Drives. User s Manual HTL Encoder Interface FEN-31

INDUSTRIAL TF1: 16 keys with LED 6AV AA00 KEYBOARDS TF2: 20 keys with LED 6AV AB00 6AV NE30-0AX0 6AV DB10 6AV FB12

SIMATIC S /30 SIPLUS digital modules 5/30 SIPLUS SM 322 digital output module. 5/31 Analog modules 5/31 SM 331 analog input module

All Analog Outputs, voltage/current 20mA 35mA 5mA 48mA/30mA* *If the analog outputs are not configured, then subtract the higher value.

Versions. Q.station Q.station T. Q.station D. Q.station DT x x

Electronics Ltd. Presenting. Power, Intelligence... with a sense of feeling

Intelligent RS-485 I/O expansion unit: RU-87Pn Series

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs

FAQ about Drive Technology

Substation Automation Products Relion 670/650 series IEC and ANSI Hardware

Programmable Logic Controller PLC

SIMATIC S Workshop. Unrestricted / Siemens AG All Rights Reserved.

Modular I/O System Analog and Digital Interface Modules

applicomio Profibus-DP

INSTALLATION INSTRUCTIONS

SIMATIC. Process Control System PCS 7 V7.0 Released Modules 11/2006 A5E

Transcription:

What's New in STEP 7 Lite V3.0 The following topics have been updated: Installation STEP 7 Lite V3.0 SP4 is released for MS Windows XP Home and MS Windows XP Professional New Licensing Procedure As of STEP 7 Lite V3.0 there is a new licensing procedure. User rights are no longer issued by means of authorizations but now by means of license keys. License Keys are managed in the Automation License Manager (see User Rights through the Automation License Manager). The "AuthorsW" program is no longer used Hardware Configuration The following modules are now supported with STEP 7 Lite V3.0: Module Order Number Firmware Short Description C7635 Key 6ES7 6352EC010AE3 V2.0 Complete device; OP 170 B + CPU with 64KB work memory; 0.1ms/1000 instructions; (2.5kHz); 4 channel counting and measurement with incremental encoders 24V (60kHz); integrated positioning function; MPI+ DP connector (DP master or DP slave); send and receive capability for direct data exchange; constant bus cycle time; routing; S7 Communication (loadable FBs/FCs); firmware V2.0 C7635 Touch 6ES7 6352EB010AE3 V2.0 Control system; TP 170 B + CPU with 64KB work memory; 0,1ms/1000 instructions; (2.5kHz); 4 channels counting and measuring master or DP slave); send and receive capability for direct data exchange; constant bus cycle time; routing; S7 Communication (loadable FBs/FCs); firmware V2.0 C7613 6ES7 6131CA010AE3 V2.0 Complete device; display and operator unit 4 rows, 21 buttons + CPU with 32KB work memory; 0.1ms/1000 instructions; DI24/DO16; AI5/AO2 integrated; 3 pulse outputs (2.5kHz); 3 channel counting and measuring with incremental encoders 24V (30kHz); MPI connector; singletier configuration up to 4 modules; firmware V2.0 A5E0263875701 1

Module Order Number Firmware Short Description C7636 Key 6ES7 6362EC000AE3 V2.0 Complete device; OP 270 6" + CPU with work memory 128KB; 0.1ms/1000 instructions; (2.5kHz); 4channel counting and measuring with master or DP slave); send and receive capability for direct data exchange; constant bus cycle time; routing; S7 Communication (downloadable FBs/FCs); firmware V2.0 CPU 3172 PN/DP 6ES7 3172EJ100AB0 V2.2 Work memory 512kb; 0.3ms/1000 instructions; Ind. Ethernet connection; MPI+ DP connection (DP master or DP slave); multitier configuration up to 32 modules; send and recieve capability for direct data exchanges; constant bus cycle time; routing; S7 communication (loadable FBs/FCs); Firmware V2.2 PME DC 24V/ AC 120/230V SM 322; DO 32xAC 120/230 V/1 A SM 321; DI 16 x DC 48125 V SM 322; DO 8 x DC 48125 V/1,5 A 6ES7 1384CA500AB0 Power module PME DC 24V, AC 120V, AC 230V, with diagnostics and backup 6ES7 3221FL000AA0 Digital output module DO32 AC 120/230V/1A, grouping 8 6ES7 3211CH200AA0 Digital input module DI16 DC 48125V, grouping 8 6ES7 3221CF000AA0 Digital output module DO8 DC 48125V/1.5A, grouping 4 SM 338 8x IQSENSE 6ES7 3387XF000AB0 Module 8 IQSENSE for the connection of IQ SENSE devices SM 331 AI 8x14 Bit 6ES7 3317HF010AB0 Analog input module AI 8x14 bits, high speed, supports isochrone mode SM327 8DI/8DX 6ES7 3271BH000AB0 Digital mixed modules; DI8 x DC24V; DX8 parameters can be assigend as input or output on single channels The following modules are now supported with STEP 7 Lite V3.0 SP1: Module Order Number Firmware Short Description CPU 3172 PN/DP ES7 3172EJ100AB0 V2.3 Work memory 512Kbytes; 0.3ms/1000 instructions; PROFINET IO Controller; MPI+ DP connection (DP master or DP slave); multitier configuration up to 32 modules; send and receive capability for direct data exchange; constant bus cycle time; routing; S7 communication (loadable FBs/FCs); Firmware V2.3 8x IQSENSE IDENT SM 332 AO4x16Bit 6ES7 3387XF000AB0 IDENT 6ES7 3327ND020AB0 Module 8 IQSENSE for connecting IQSENSE devices Analog output module 4AO/16 bits, supports isochrone mode 2 A5E0263875701

Module Order Number Firmware Short Description CPU 314C2 DP 6ES7 3146CF020AB0 V2.0 Work memory 64KB; 0.1ms/1000 instructions; master or DP slave); multitier configuration up to 31 modules; end and receive capability for direct data exchange; constant bus cycle time; routing; S7 Communication (loadable FBs/FCs); firmware V2.0 CPU 314C2 PtP 6ES7 3146BF020AB0 V2.0 Work memory 64KB; 0.1ms/1000 instructions; positioning function; MPI+ PtP connector (RS422/485 (ASCII, 3964(R), RK512)); multitier configuration up to 31 modules; firmware V2.0 CPU 314 6ES7 3141AF110AB0 V2.0 Work memory 64 KB; 0.1 ms/1000 instructions; MPI connection; multitier configuration up to 32 modules; S7 communication (loadable FBs/FCs); firmware V2.0 CPU 3152 PN/DP 6ES7 3152EG100AB0 V2.3 Work memory 128kilobytes; 0.1ms/1000 instructions; PROFInet I/O; S7 communication (downnloadable FBs/FCs); CbA; PROFInet IO; combined MPI/DP I/O (MPI or DP master or DP slave); multiline configuration up to 32 modules; send and receive capability for direct data exchange; constant bus cycle time DP bus cycle; routing; Firmware V2.3 C7 636 Touch 6ES7 6362EB000AE3 V2.0 Complete device; TP 270 10" + CPU with work memory 128KB; 0.1ms/1000 instructions; ; (2.5kHz); 4channel counting and measuring with master or DP slave); send and receive capability for direct data exchange; constant bus cycle time; routing; S7 Communication (downloadable FBs/FCs); firmware V2.0 SM 331 AI8xRTD 6ES7 3317PF010AB0 Analog input module AI8xRTD, 16Bit (24 bit internal to the sigmadelta mode); RTD: Pt100, Pt200, Pt500, Pt1000, Ni100, Ni120, Ni1000, Cu10; parameters can be changed online SM 331 AI8xTC 6ES7 3317PF110AB0 Analog input module AI8xTC, 16Bit (24 bit internal to the sigmadelta mode); Thermocouples: B, E, J, K, L, N, R, S, T, U, C; parameters can be changed online SM 338 POSINPUT 6ES7 3384BC010AB0 V2.0 Position decoder module POSINPUT, supports isochrone mode ET 200S IM1517 CPU ET 200X BM 147 / CPU 6ES7 1517AA110AB0 V2.1 Work memory 64KB; 0.3ms/1000 instructions; MPI+ DP connector (stand alone or DP slave); send and receive capability for direct data exchange; firmware V2.1; expansion with a maximum of 63 modules of the ET200S range 6ES7 1471AA110XB0 V2.1 Work memory 64KB; 0.1ms/1000 instructions; slots: MPI/DP slave; send capability for direct data exchange; firmware V2.1 A5E0263875701 3

Module Order Number Firmware ET 200X BM 147 / CPU ET 200X BM 147 / CPU Analogmodul 4AI 2 WIRE Short Description 6ES7 1472AA010XB0 V2.1 Basic module BM147 with programmable preprocessing, work memory 64KB; 0.1ms/1000 instructions; slots: MPI/DP slave and DP master; send capability for direct data exchange; firmware V2.1; singlerow configuration of up to 7 expansion modules of the ET200X range 6ES7 1472AB010XB0 V2.1 Basic module BM147 with programmable preprocessing, work memory 128KB; 0.1ms/1000 instructions; slots: MPI/DP slave and DP master; send capability for direct data exchange; firmware V2.1; singlerow configuration of up to 7 expansion modules of the ET200X range 6ES7 1344GD000AB0 V1.00 Analog input module AI 4xI, 2wireMU(4..20mA), 4 DI 6ES7 1314BD010AA0 Digital input module DI 4x24V DC, 4 DI HF 6ES7 1314BD010AB0 Digital input module 4 DI 24VDC, High Feature; diagnostics, supports clocking 4 DI SRC 6ES7 1314BD510AA0 Digital input module 4 DI DC24V, SOURCE INPUT; Mtype 2 DO / 0.5A 6ES7 1324BB010AA0 Digital output module DO 2x24 VDC/0.5 A, 2 DO / 0.5A HF 6ES7 1324BB010AB0 Digital output module DO 2x24 VDC/0.5 A, High Feature, diagnostics, supports clocking 2 DO / 2A 6ES7 1324BB310AA0 Digital output module DO 2x24 VDC/2 A, 2 DO / 2A HF 6ES7 1324BB310AB0 Digital output module DO 2x24 VDC/2 A, High Feature, diagnostics, supports clocking 4 DO / 0.5A 6ES7 1324BD010AA0 Digital output module DO 4x24 VDC/0.5A,, supports clocking 4 DO / 2A 6ES7 1324BD310AA0 Digital output module DO 4x24 VDC/2A, 2RO NO 6ES7 1324HB010AB0 Digital output module 2x relay 24 VUC to 230 VUC/5 A 2 AI U 6ES7 1344FB010AB0 Analog input module AI 2xU (+/5 V /13 bits+sign, 1 to 5 V/13 Bit, +/10 V /13 bits+sign), 2 AI 2WIRE 6ES7 1344GB010AB0 Analog input module AI 2xI, 2wire transmitter (4mA to 20 ma) / 13 bits, 2 AI 4WIRE 6ES7 1344GB110AB0 Analog input module AI 2xI, 4wire transmitter (+/20 ma /13 bits+sign, 4 ma to 20 ma/13 bits), 2 AO U 6ES7 1354FB010AB0 Analog output module AO 2xU (1 V to 5V /13 bits, +/10 V /13 bits+sign),, as of release 3 2 AO I 6ES7 1354GB010AB0 Analog output module AO 2xI (+/20 ma /13 bits+sign, 4 ma to 20 ma /13 bits),, as of release 3 2 DI DC 24V 6ES7 1314BB010AA0 Digital input module DI 2x24V DC, 2 DI DC 24V High Feature 6ES7 1314BB010AB0 Digital input module DI 2x24V DC, High Feature; diagnostics, supports clocking PME DC 24V 6ES7 1384CA010AA0 Power module PME for electronic modules, 24 VDC, with diagnostics 4 A5E0263875701

The following modules are now supported with STEP 7 Lite V3.0 SP2: Module Order Number Firmware Short Description CPU 312 C 6ES7 3125BE030AB0 V2.0 Work memory 32KB; 0.2ms/1000 instructions; DI10/DO6 integrated; 2 pulse outputs (2.5kHz); 2 channel counting and measuring with incremental encoders 24V (10kHz); MPI connector; singletier configuration up to 8 modules; Firmware V2.0 CPU 313 C 6ES7 3135BF030AB0 V2.0 Work memory 64KB; 0.1ms/1000 instructions; DI24/DO16; AI5/AO2 integrated; 3 pulse outputs (2.5kHz); 3 channel counting and measuring with incremental encoders 24V (30kHz); MPI connector; multitier configuration up to 31 modules; Firmware V2.0 CPU 313 C2 PtP 6ES7 3136BF030AB0 V2.0 Work memory 64KB; 0.1ms/1000 instructions; DI16/DO16 integrated; 3 pulse outputs (2.5kHz); 3 channel counting and measuring with incremental encoders 24V (30kHz); MPI+ PtP connector (RS422/485 (ASCII, 3964(R))); multitier configuration up to 31 modules; firmware V2.0 CPU 313 C2 DP 6ES7 3136CF030AB0 V2.0 Work memory 64KB; 0,1ms/1000 instructions; DI16/DO16 integrated; 3 pulse outputs (2.5kHz); 3 channel counting and measuring with incremental encoders 24V (30kHz); MPI+ DP connector (DPMaster oder DPSlave); multitier configuration up to 31 modules; Send and receive capability for direct data exchange; constant bus cycle time; routing; S7 Communication (loadable FBs/FCs); Firmware V2.0 CPU 314 C2 PtP 6ES7 3146BG030AB0 V2.0 Work memory 96KB; 0.1ms/1000 instructions; positioning function; MPI+ PtP connector (RS422/485 (ASCII, 3964(R), RK512)); multitier configuration up to 31 modules; firmware V2.0 CPU 314 C2 DP 6ES7 3146CG030AB0 V2.0 Work memory 96KB; 0.1ms/1000 instructions; master or DP slave); multitier configuration up to 31 modules; end and receive capability for direct data exchange; constant bus cycle time; routing; S7 Communication (loadable FBs/FCs); firmware V2.0 CPU 312 6ES7 3121AE130AB0 V2.0 Work memory 32 KB; 0.2 ms/1000 instructions; MPI connection; singletier configuration up to 8 modules; S7 communication (loadable FBs/FCs); Firmware V2.0 CPU 314 6ES7 3141AG130AB0 V2.0 Work memory 96 KB; 0.1ms/1000 instructions; MPI connection; multitier configuration up to 32 modules; S7 Communication (loadable FBs/FCs); firmware V2.0 A5E0263875701 5

Module Order Number Firmware Short Description CPU 3152PN/DP 6ES7 3152EH130AB0 V2.3 256 KB work memory; 0.1 ms/1000 instructions; (loadable FBs/FCs); PROFINET IOContoler; PROFINET CBA; PROFINET CBAProxy; (MPI or DP master or DP slave); multitier cycle time; routing; firmware V2.3 CPU 3172PN/DP 6ES7 3172EK130AB0 V2.3 1024 KB work memory; 0.05ms/1000 instructions; PROFINET connection; S7 Communication (loadable FBs/FCs); PROFINET IOControler; PROFINET CBA; PROFINET CBA Proxy; TCP/IP transport protocol; combined MPI/DP connection (MPI or DP master or DP slave); multitier configuration up to 32 modules; constant DP bus cycle time; routing; firmware V2.3 IM 151 / CPU 6ES7 1517AA130AB0 V2.1 Work memory 96KB; 0.3ms/1000 instructions; MPI+ DP connector (stand alone or DP slave); send and receive capability for direct data exchange; firmware V2.1; expansion with a maximum of 63 modules of the ET200S range The following modules are now supported with STEP 7 Lite V3.0 SP3: Module Order Number Firmware Short Description C7 613 6ES7 6131CA020AE3 V2.6 Complete device; display and operator unit 4 rows, 21 buttons + CPU 313C with 64KB work memory; 0.1ms/1000 instructions; DI24/DO16; AI5/AO2 integrated; 3 pulse outputs (2.5kHz); 3 channel counting and measuring with incremental encoders 24V (30kHz); MPI connector; singletier configuration up to 4 modules; firmware V2.6 C7 635 Touch 6ES7 6352EB020AE3 V2.6 Control system; TP 170 B + CPU with 96KB work memory; 0.1ms/1000 instructions; DI24/DO16; AI5/AO2 integrated; 4 pulse outputs (2.5kHz); 4 channels counting and measuring incremental encoders 24V (60kHz); integrated positioning function; MPI+ DP connector (DP master or DP slave); send and receive capability for direct data exchange; constant bus cycle time; routing; S7 Communication (loadable FBs/FCs); firmware V2.6 C7 635 Key 6ES7 6352EC020AE3 V2.6 Complete device; OP 170 B + CPU with 96KB work memory; 0.1ms/1000 instructions; (2.5kHz); 4 channel counting and measurement with incremental encoders 24V (60kHz); integrated positioning function; MPI+ DP connector (DP master or DP slave); send and receive capability for direct data exchange; constant bus cycle time; routing; S7 Communication (loadable FBs/FCs); firmware V2.6 6 A5E0263875701

Module Order Number Firmware Short Description C7 636 Touch 6ES7 6362EB000AE3 V2.6 Complete device; TP 270 10" + CPU with work memory 128KB; 0.1ms/1000 instructions; ; (2.5kHz); 4channel counting and measuring with master or DP slave); send and receive capability for direct data exchange; constant bus cycle time; routing; S7 Communication (loadable FBs/FCs); firmware V2.6 C7 636 Key 6ES7 6362EC000AE3 V2.6 Complete device; OP 270 6" + CPU with work memory 128KB; 0.1ms/1000 instructions; (2.5kHz); 4channel counting and measuring with master or DP slave); send and receive capability for direct data exchange; constant bus cycle time; routing; S7 Communication (loadable FBs/FCs); firmware V2.6 CPU 314C2 DP 6ES7 3146CG030AB0 V2.6 Work memory 96KB; 0.1ms/1000 instructions; master or DP slave); multitier configuration up to 31 modules; send and receive capability for direct data exchange; constant bus cycle time; routing; S7 Communication (loadable FBs/FCs); firmware V2.6 CPU 314C2 PtP 6ES7 3146BG030AB0 V2.6 Work memory 96KB; 0.1ms/1000 instructions; positioning function; MPI+ PtP connector (RS422/485 (ASCII, 3964(R), RK512)); multitier configuration up to 31 modules; firmware V2.6 CPU 312C 6ES7 3125BE030AB0 V2.6 Work memory 32KB; 0.2ms/1000 instructions; DI10/DO6 integrated; 2 pulse outputs (2.5kHz); 2 channel counting and measuring with incremental encoders 24V (10kHz); MPI connector; singletier configuration up to 8 modules; firmware V2.6 CPU 313C 6ES7 3135BF030AB0 V2.6 Work memory 64KB; 0.1ms/1000 instructions; DI24/DO16; AI5/AO2 integrated; 3 pulse outputs (2.5kHz); 3 channel counting and measuring with incremental encoders 24V (30kHz); MPI connector; multitier configuration up to 31 modules; firmware V2.6 CPU 313C2 DP 6ES7 3136CF030AB0 V2.6 Work memory 64KB; 0.1ms/1000 instructions; DI16/DO16 integrated; 3 pulse outputs (2.5kHz); 3 channel counting and measuring with incremental encoders 24V (30kHz); MPI+ DP connector (DP master or DP slave); multitier configuration up to 31 modules; Send and receive capability for direct data exchange; constant bus cycle time; routing; S7 Communication (loadable FBs/FCs); firmware V2.6 CPU 313C2 PtP 6ES7 3136BF030AB0 V2.6 Work memory 64KB; 0.1ms/1000 instructions; A5E0263875701 7

Module Order Number Firmware Short Description DI16/DO16 integrated; 3 pulse outputs (2.5kHz); 3 channel counting and measuring with incremental encoders 24V (30kHz); MPI+ PtP connector (RS422/485 (ASCII, 3964(R))); multitier configuration up to 31 modules; firmware V2.6 IM 1517 CPU 6ES7 1517AA200AB0 V2.6 Work memory 96KB; 0.3ms/1000 instructions; MPI+ DP connector (stand alone or DP slave); send and receive capability for direct data exchange; firmware V2.6; expansion with a maximum of 63 modules of the ET200S range CPU 312 6ES7 3121AE130AB0 V2.6 Work memory 32 KB; 0.2 ms/1000 instructions; MPI connection; singletier configuration up to 8 modules; S7 communication (loadable FBs/FCs); firmware V2.6 CPU 314 6ES7 3141AG130AB0 V2.6 Work memory 96 KB; 0.1ms/1000 instructions; MPI connection; multitier configuration up to 32 modules; S7 Communication (loadable FBs/FCs); firmware V2.6 CPU 3152 DP 6ES7 3152AG100AB0 V2.6 Work memory 128KB; 0.1ms/1000 instructions; MPI+ DP connection (DP master or DP slave); multitier configuration up to 32 modules; Send and receive capability for direct data exchange, constant bus cycle time, routing, S7 Communikation (loadable FBs/FCs), firmware V2.6 ET 200S 8DI DC24V/SRC ST ET200S 4DO DC24V/0.5A SINK OUT ET200S 8DO DC24V/0.5A SINK OUT 6ES7 1314BF500AA0 6ES7 1324BD500AA0 6ES7 1324BF500AA0 Digital input module 8DI DC24V, SOURCE INPUT; reading M, supports isochrone mode Digital output module DO 4xDC24V/0.5A, SINK OUTPUT; switching M, supports isochrone mode Digital output module DO 8xDC24V/0.5A, SINK OUTPUT; switching M, supports isochrone mode PMO 2x24VDC 6ES7 1484CA600AA0 Power module PMO 2x24VDC 2AI U HS 6ES7 1344FB520AB0 V2.0 Analog input module AI 2xU (+/2.5V / 14 bits+sign, 1..5V / 14 bits, +/5V, +/10V / 15 bits+sign), high speed, supports isochrone mode 2AI I 4WIRE HS 6ES7 1344GB620AB0 V2.0 Analog input module AI 2xI, 4wire MU (+/20mA / 15 bits+sign, 0..20mA, 4..20mA / 15 bits), high speed, supports isochrone mode 2AO I HS 6ES7 1354GB520AB0 V2.0 Analog output module AO 2xI (+/20mA / 15 bits+sign, 4..20mA / 15 bits), high speed, supports isochrone mode 4DO DC24V/0.5A ST 6ES7 1324BD020AA0 V2.0 Digital output module DO 4x24 VDC/0.5A,, supports isochrone mode PS 307 10A 6ES7 3071KA010AA0 V4.0 Load supply voltage 120 / 230 VAC:24 VDC / 10 A The following modules are now supported with STEP 7 Lite V3.0 SP4: Module Order Number FW Short Description 8 A5E0263875701

Module Order Number FW Short Description CPU 3152 PN/DP 6ES7 3152EH130AB0 V2.5 256 KB work memory; 0.1 ms/1000 instructions; (loadable FBs/FCs); PROFINET IOController; supports RT; PROFINET interface and 1 port; PROFINET CBA; PROFINET CBAProxy; TCP/IP (MPI or DP master or DP slave); multitier cycle time; routing; firmware V2.5 CPU 3152 PN/DP 6ES7 3152EH130AB0 V2.6 256 KB work memory; 0.1 ms/1000 instructions; (loadable FBs/FCs); PROFINET IOController; supports RT; PROFINET interface and 1 port; PROFINET CBA; PROFINET CBAProxy; TCP/IP (MPI or DP master or DP slave); multitier cycle time; routing; firmware V2.6 CPU 3172 PN/DP 6ES7 3172EK130AB0 V2.5 1024 KB work memory; 0.05ms/1000 instructions; (loadable FBs/FCs); PROFINET IOController; supports RT; PROFINET interface and 1 port; PROFINET CBA; PROFINET CBAProxy; TCP/IP (MPI or DP master or DP slave); multitier cycle time; routing; firmware V2.5 CPU 3172 PN/DP 6ES7 3172EK130AB0 V2.6 1024 KB work memory; 0.05ms/1000 instructions; (loadable FBs/FCs); PROFINET IOController; supports RT; PROFINET interface and 1 port; PROFINET CBA; PROFINET CBAProxy; TCP/IP (MPI or DP master or DP slave); multitier cycle time; routing; firmware V2.6 ET 200S 2RO NO/NC 24..230V/5A 6ES7 1324HB500AB0 Digital output module 2xrelay Form C UC 24..230V/5A with manual operation ET 200S 2 AI TC ST 6ES7 1344JB010AB0 Analog input module AI 2xTC / 15 bits+sign,, thermocouples: E, N, J, K, L, S, R, B, T ET 200S 2/4 AI RTD ST; 2ch ET 200S 2/4 AI RTD ST; 4ch 6ES7 1344JB510AB0 6ES7 1344JB510AB0 Analog input module 2/4xAI RTD 2ch / 15 bits+sign,, R: 150 ohms, 300 ohms, 600 ohms, PTC; RTD: Pt100, Ni100 Analog input module 2/4xAI RTD 4ch / 15 bits+sign,, R: 150 ohms, 300 ohms, 600 ohms, PTC; RTD: Pt100, Ni100 CPU 3193 PN/DP 6ES7 3183EL000AB0 V2.8 Work memory 1400KB; 0.01ms/1000 instructions; PROFINET connection; S7 communication (loadable FBs/FCs); PROFINET IOController; supports RT/IRT; PROFINET interface and 1 port; PROFINET CBA; PROFINET CBAProxy; TCP/IP (MPI or DP master or DP slave); multiline structure up to 32 modules; constant DP bus cycle time; routing; data record routing; firmware V2.8 CPU 312 6ES7 3121AE140AB0 V3.0 Work memory 32 KB; 0.1 ms/1000 instructions; MPI connection; singletier configuration up to 8 A5E0263875701 9

Module Order Number FW Short Description modules; S7 communication (loadable FBs/FCs); firmware V3.0 CPU 314 6ES7 3141AG140AB0 V3.0 Work memory 128 KB; 0.06ms/1000 instructions; MPI connection; multitier configuration up to 32 modules; S7 Communication (loadable FBs/FCs); firmware V3.0 CPU3152 DP 6ES7 3152AH140AB0 V3.0 Work memory 256KB; 0.05ms/1000 instructions; MPI+ DP connection (DP master or DP slave); multitier configuration up to 32 modules; Send and receive capability for direct data exchange, constant bus cycle time, routing, S7 Communikation (loadable FBs/FCs), firmware V3.0 CPU 3152 PN/DP 6ES7 3152EH140AB0 V3.1 384 KB work memory; 0.05ms/1000 instructions; (loadable FBs/FCs); PROFINET IOController; supports RT/IRT; PROFINET interface and 2 ports; PROFINET CBA; PROFINET CBAProxy; TCP/IP (MPI or DP master or DP slave); multitier cycle time; routing; firmware V3.1 CPU 3172 PN/DP 6ES7 3172EK140AB0 V3.1 1024 KB work memory; 0.025ms/1000 instructions; (loadable FBs/FCs); PROFINET IOController; supports RT/IRT; PROFINET interface and 2 ports; PROFINET CBA; PROFINET CBAProxy; TCP/IP (MPI or DP master or DP slave); multitier cycle time; routing; firmware V3.1 10 A5E0263875701