TECHNOLOGY THIS GOOD JUST WORKS LIKE MAGIC!

Similar documents
R.C.C.B. s two-pole LEXIC

Thermal-Magnetic Circuit Breaker M1-..

Electronic overload relay EF19 and EF45

Uncompromising safety and comfort The next generation of miniature circuit breakers MCB S 200/S 200 M

Type: DILM50(230V50HZ,240V60HZ) Article No.:

Electronic overload relay EF65, EF96 and EF146

The complete range of consumer switchboards and switchgear

RM4TG20 three-phase network control relay RM4-T - range V

Type: DILM115(RAC240) Article No.: Sales text Contactor,55kW/400V,AC operated. Ordering information

49 Series - Relay interface modules A. Features

Mini Circuit Breakers, Fuse Blocks, and Electronic Circuit Protection

AF / AF09Z stack 3-pole Contactors AC / DC Operated - with Screw Terminals

Type: DILM32 10(24V50HZ) Article No.:

pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2, /0.65/0.

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

LC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A V AC coil

NF71E-.. / NFZ71E-.. Contactor Relays AC / DC Operated - with Screw Terminals

Residual Current Circuit Breaker

Type: DILM9 10(24VDC) Article No.:

Three-phase monitoring relay CM-PFE

Circuit Breakers. Next Generation of Protection Capabilities

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2...

48 SERIES Relay interface modules 10 A

Tmax MCCBs. Molded case circuit breakers. Tmax

Technicaldata General

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

Manual Motor Starter MS 116 up to 16 A Technical Data

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start * see variants. Applications.

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N

Building Circuit Protection

Power Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1

Bimetallic Overload Relay Specifications

Catalog. Modular DIN rail components Installation contactors

Manual motor starter MS116

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

Mini Motor Contactor J7KNA Main contactor Accessories Approved Standards Standard Guide No (US,C) Ordering Information tage Model Number Legend gear

VEO. V4PF480Y/277VSYTK02 Art.Nr.: V4PF480Y/277VSYTK02P Art.Nr.: TECHNICAL DATA

Bulletin 1489 Circuit Breakers. Selection Guide

E-STOP relays, safety gate monitors

38 SERIES. Relay interface modules A. EMR Electromechanical Relays. Common features. SSR Solid State Relays. 6.

Molded Case Circuit Breaker Specifications Bulletin Number 140U-D

5SV Residual Current Protective Devices

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

ABB 1 NEW. Three-phase monitoring relay for grid feeding CM-UFS.1. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories

38 Series - Relay interface modules A

Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages

Technical catalogue. Modular DIN rail components Installation contactors

ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application.

Bulletin 150 SMC Flex Smart Motor Controller Specifications

RM35UA13MW. range V. Main. Product or component type. Relay monitored parameters

Pluggable interface relays CR-P Pcb relays

System pro M compact Miniature Circuit Breaker S 200/S 200 M

Low voltage Direct Current Network. Compact NSX DC PV. Circuit breakers and switch disconnectors for solar application.

SURGE PROTECTIVE DEVICES

Electronic timer CT-VBS OFF-delayed without auxiliary voltage, for DC contactors Data sheet

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)

38 Series - Relay interface modules A

Application Switchgear for industrial and commercial applications. U e V AC 230/ (per pole)

40 Series - Miniature PCB/Plug-in relays A. Features

AUTOMATIC TRANSFER SWITCH. Changeover Type from 250A to 2500A

Thermistor motor protection

34 Series - Slim electromechanical PCB relays 6 A. Features SERIES 34.51

MILLENIUM INSTALLATION MANUAL NTR 735 A. Simple Automation Control Module (MAS)

BETA Switching. Switching Devices. 5TT5 8 Insta contactors, AC technology. Overview

W DATA SHEET: RESIDUAL CURRENT CIRCUIT BREAKER A, SERIES BCF0 AND BCF6

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

MasterINTERFACE 39 Series - Relay interface modules

Contact expander modules

PNOZsigma - Base units

DLP-PU/E Instruction Manual

1 pole, 16 A Screw terminal connection 35 mm rail (EN 60715) mounting. 2 pole, 8 A Screw terminal connection 35 mm rail (EN 60715) mounting

Product and functional description

Distribution Boards & Consumer Units

Fuses for Semiconductor Protection - Cylindrical Fuses. Class: Voltage ratings: Current ratings: Standards: Approvals: Features and Benefits

D-Line Contactors, Overload Relays and Accessories

PSR The compact range Description

PHOENIX CONTACT Features

Digital input modules

Safety technique. Emergency stop module BO 5988 safemaster

Bulletin 150 Smart Motor Controllers SMC-3 Smart Motor Controller

Chapter 5. Components, Symbols, and Circuitry of Air-Conditioning Wiring Diagrams

Thermistor motor protection relays CM-MSS.22 and CM-MSS.23

Relés e Contatores de Estado Sólido SIRIUS

SICONT Limit Switches Type 3SE3 upto 500 VAC, 600 VDC, 10A

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

Uncompromising safety and comfort Miniature Circuit Breaker SU 200 M for branch circuit protection per UL and CSA

Vario-Series Accessories

ABB i-bus KNX Fan Coil Actuator, MDRC FCA/S 1.1M, 2CDG R0011

RY2 miniature industrial relays

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

SUBJECT: How to wire a motor starter Number: AN-MC-004 Date Issued: 2/08/2005 Revision: Original

Digital Energy ITI. Instrument Transformer Basic Technical Information and Application

Redundancy Module QUINT-DIODE/40

Contact expansion modules

REB 1 REB 3 REB 5 REB 6 REB 8 REB 10 REB 12 REB 16

Meter Relays. 077 Series Analogue Meter Relays. Features. Applications

SIRCOVER. Manual changeover switches from 125 to 3200 A. Changeover switches. Function. Advantages. The solution for.

more than a breaker it s a breakthrough Compact NSX

Electro-pneumatic control valves

Transcription:

TECHNO MCB TECHNOLOGY THIS GOOD JUST WORKS LIKE MAGIC! - SAFETY FOR YOU AND YOUR SMILES. - ALL ROUND PROTECTION. - PROTECTION FOR YOU AND YOUR LOVED ONES. DC MCB UPTO 63A AC MCB UPTO 80A ISOLATOR UPTO 125A AUXILIARY SWITCH

WHEN THE TRACK RECORD SAYS IT ALL, IT S GOT TO BE HPL. When it comes to the most innovative designs and developments, you do not have to look beyond HPL. As a matter of fact we go out of our way to ensure that each and every one of our customers benefit from our cuttingedge technical expertise. That s why we put our best foot forwrad and work with both users and influencers to examine various applications and operations in ever-minute detail. In doing so, we fully identify and respect every single need of the end user so as to offer him or her a complete, practical, and individually customised solution. And this does not happen just like that. For us, it is extremely crucial to have a global, outside-in perspective towards our products. Our joint ventures with Socomec S.A. France and technical collaboration with LS Industrial systems co. Ltd. Korea testify to that and only helps us strengthen that further. In the bargain, it also speaks volumes for the values we attach to our organisation s working in order to achieve efficiencies for the business. HPL MCBS MAGNIFICENT. CAPABLE. BANKABLE. That s why we proudly present to you our wide range of Miniature Circuit Breakers with a unique combination of personalised safety, reliability and trouble free service. Nothing more needs to be said about them because they are a direct outcome of the kind of attention to detail which has made the HPL brand a name to reckon with not only in industry circles but even with the wider segment of its end consumers. ELECTRICITY THE POETRY BEHIND MODERN DAY LIVES. The sheer importance of electricity cannot but be overstated in our daily lives. Be it the joy of watching your favourite sport or merely charging that smart phone which keeps your life buzzing life, as we know it today is just not possible without it. So much so that a day without electricity is akin to a day without much engagement, productivity or entertainment. This wide and significant use of electricity requires ever greater levels of safety equipment. It demands confirmations to the most stringent international quality standards as per the latest national and international specifications. 10 KA SPECIFICATION IS/IEC 60898-1 SHORT CIRCUIT BREAKING CAPACITY 10 KA TYPE CLASSIFICATION B, C & D RATED VOLTAGE 240 / 415 V 50 HZ REF. AMBIENT TEMPERATURE 30 DEGREES C

80 AMP MCB & 125 AMP ISOLATOR 80 AMP MCB AND 125 AMP ISOLATOR HAVE BEEN DESIGNED, KEEPING IN MIND EVERY CUSTOMER S NEEDS AND SO BOASTS OF MAGNIFICENT FEATURES Conforms to IS/IEC 60898-1 A standard thickness of 17.5mm, similar to lower rating of MCB (0.5A to 63A) to facilitate easy mounting in any distribution box without requiring any extra space or special distribution boards. Box type terminal for easy termination of cable up to 50mm. Heavy duty screws for better tightening of contacts. Heavy duty ETP copper terminals and extra thick silver inlaid contacts to ensure low temperature rise and low watt loss. DC MCB UPTO 80 AMPS TECHNO MCB specially designed for DC application has been developed by HPL s world class R&D to meet the market s stringent requirements for DC circuits. Housing of DC MCB is made up of fire retardant, anti-tracking and non-hygroscopic injection moulded thermoplastic polyester. Contacts are made up of silver inlaid copper, which ensure low resistance and longer life of circuit breaker. SALIENT FEATURES CONFORMS TO LATEST STANDARDS TECHNO MCB conforms to the latest standard IS/IEC 60898-1 in selected ratings. CE MARKING fulfils the requirement of global standards. ENERGY MOUNTING The low power loss as stipulated in the IEC 898/95, IS/IEC 60898-1 has been taken care of in designing the TECHNO MCB as it contributes significantly to the energy saving. DIN RAIL MOUNTING TECHNO MCB s can be mounted on standard 35mm DIN Rail by snap action. No time wastage in installing and replacing the MCB. SHOCK PROOF Finger and hand touch safe. Tested as per the test clause 9.6 of IS/IEC 60898-1 protection against electric shock. AVAILABILITY DC MCBs are available in SP & DP configuration from 0.5 Amp to 80 Amp in various voltages such as 12V, 24V, 48V, 60V, 110V, & 220V. FEATURES Dual tripping system-overload through precisely calibrated bimetal and short circuit through electromagnetic coil. DC MCB incorporates a built in permanent magnet, which directs the arc into the arc quenching chamber. Free from nuisance tripping caused by vibrations. Time constant < 5ms DC MCB offers a unique feature of knob assuming mid trip position in the event of fault. This enables clear visual indication of the faulty circuit.

SAILENT FEATURES CONT... HOUSING The housing of TECHNO MCB is injection moulded from special grade PBT / Nylon as per international specifications. The housing and other moulded components are fire retardant,anti-tracking and non-hygroscopic. The housing can withstand high temperatures and is impact resistant. CONTACTS Contacts are made of special silver inlaid into copper strip, ensuring higher life and maximum safety against contact welding and erosion. These contacts have low contact resistance resulting in reduced watt loss. CURRENT LIMITING ACTION The high speed current limiting action ensures that the MCB operates before the full prospective fault current is allowed to develop. Under fault conditions, damage can be sustained to the installation and association equipment due to the amount of energy that passes before the current is completely interrupted. The total energy let through depends on the value of current and the time for which it flows, and is denoted by the symbol l2t. The high speed current limiting action of TECHNO MCB ensures that the energy let through and any subsequent damage is minimized. The reduced LET THROUGH ENERGY (Class 3 as per BS EN 60898) assists greatly with both back-up and discrimination considerations. OPERATING MECHANISM TEHCNO MCB has a quick make & break Trip Free Mechanism. In the event of an over current or short circuit the MCB automatically interrupts all poles even if the MCB toggle is held in ON position, the handle always indicates the correct contact position. MODERATE OVERLOAD CONDITION Detection of moderate overload conditions is achieved by the use of a Bimetal Overload Relay, which deflects in response to the current passing through it. The Bimetal Relay moves against the trip bar releasing the trip mechanism. SHORT CIRCUIT CONDITIONS When the current flowing through the MCB reaches a predetermined level, the solenoid in Magnetic Coil directly pulls in the plunger, which releases the trip mechanism. PERFECT CONNECTIONS The design of terminals makes the wiring easier. Combination box type terminals with combination head screws on both sides along with deep serrations ensures sparkles & firm connections. The bi-connection facility simplifies connection in various application areas. LOW WATT LOSS TECHNO MCBs have been designed to minimize energy loss through unique contact configuration & reduction of hot spots. Watt loss per role in TECHNO MCB is far lower than that specified in IS/IEC 60898-1. MID TRIP POSITION POSITION OF THE KNOB IS CLEAR INDICATION OF THE FAULT. FAULTY CIRCUIT IDENTIFICATION BECOMES EASY. RATED CURRENT MAX. ALLOWABLE WATT LOSS PER POLE AS PER IS/IEC 60898-1 ON MID-TRIP OFF 6 < In < 10 3.0 0.75 10 < In < 16 3.5 2.0 16 < In < 25 4.5 2.6 25 < In < 32 6.0 3.3 32 < In < 40 7.5 4.0 40 < In < 50 9.0 4.6 50 < In < 63 13.0 5.2 80 < In < 100 Consideration 9.2 C 32 10000 3 240V ~ 50Hz TECHNO MCB MAX. WATT LOSS PER POLE

SAILENT FEATURES CONT... POTENTIAL FREE DIN CLIP The all insulated DIN clip ensures electrical safety and high mechanical strength. WORKING PRINCIPLE TECHNO MCB is a high fault capacity, thermal-magnetic type of breaker. It protects against overload and short circuit. Overload protection is achieved with a thermal bi-metal strip which gets heated in case of overload an in turn pushes the trip latch which releases the contacts. The operating knob is switched to Mid Trip Position clearly indicating the fault. In case of short circuit the high fault current energizes the magnetic coil resulting in plunger striking the trip lever which ensures immediate release of tripping mechanism and the operating knob is switched to Mid Trip Position. TRIPPING CHARACTERISTICS Techno Type Non-Tripping Tripping Magnetic Tripping Mcb Current Min. Current Max. Min Max. (1 Hr.) (1 Hr.) 0.5 A 80 A B 1.13 in 1.45 In 3 In 5 In 0.5 A 80 A C 1.13 in 1.45 In 5 In 10 In 0.5 A 80 A D 1.13 in 1.45 In 10 In 20 In RECOMMENDED APPLICATIONS B TYPE For protection of Resistive load such as bulb, heater, etc. C TYPE For protection of Inductive load such as motor, air conditioner, etc. D TYPE For protection of Cables and highly Inductive load which have high starting current such as transformers, etc. AUXILIARY SWITCH TECHNO MCB with Auxiliary Switch Auxiliary switch can be supplied factory fitted with any MCB (SP, SPN, DP, TP, TPN, FP) to give indication of ON or OFF position of MCB. FUNCTION The auxiliary switch is used for remote indication of the circuit condition (ON/OFF) of the MCB. All the connecting terminals are easily accessible from the top position. The auxiliary switch is connected to the tripping mechanism of MCB and operates along with the MCB. It is available in factory fitted module. Auxiliary switch can be supplied factory fitted with any MCB (SO, SPN, DP, TP, TPN, FP) to give indication of ON or OFF position of MCB. This can be used in following outgoing combination modes depending upon user requirement. Configuration Combination of Terminals to be used N.C. & N.O. 21-22, 11-14 N.C. & Changeover 21-2 2, 11-12, 14 N.C. & N.C. 21-22, 11-12 WIRING DIAGRAM TECHNO MCB TP&N 63 Amp TECHNICAL DATA RATEDConfiguration CURRENT Rated Voltage Rated Current Conductor Crossection Tightening Torque Combination of Terminals to be used 220 V AC/110 V DC 6 A AC/1 A DC Upto 1mm2 1 Nm

TRIPPING CHARACTERIS CURVES Tripping Characteristics Curve Type B, C & D Tripping Characteristics Curve DC MCB Type B & C Techno MCB Vs Zero Point Extinguishing MCB Temperature Compensation Graph

TRIPPING CHARACTERIS CURVES Specifications Number of poles Tripping Characteristics & Rating Currents (In) Rates breaking capacity (Icn) Energy Limiting Class Rated Voltages (Ue) Single Pole Multi Pole Insulation Voltage (Ui) Rated Frequencies Impulse withstand voltage (Uimp) Impulse power frequency voltage Housing material Degree of protection Mounting Position Mounting Connecting Terminals Electrical Service Life Ambient Temperature Impact Resistance IS/IEC 60898-1 1, 1+N, 2, 3, 3+N & 4 B characteristics 0.5 A to 80 A C characteristics - 0.5 A to 80 A 10,000 A Class 3 as per BS EN 60898 240/415 V AC 415 V AC 660 V 50/60 Hz 4 KV (1.2/50 µ) 2 KV (50 Hz) PBT/Nylon in Grey Color IP 20 as per IS/IEC 60898-1 Any position Quick snap to mounting rails, 35 mm Combination box terminals on incoming and outgoing sides. Suitable for single-core, stranded and flexible conductors upto 25 sq mm, combination crosshead screw, max, tightening torque 2 Nm Min. 30,000 make/break operations Tmax 5 C To 55 C (with de-rating factor) 3g, At least 2 impacts duration 13 ms IS/IEC 60898-2-2002 Single pole, Double pole 0.5 A 80 A 220 V DC 1kA 660 V IP 20 as per IS/IEC 60898-2 Any position Combination box type terminals on both sides 4000 Cycles 3g, Atleast 2 impacts duration 13 ms. IS 13947 Part 3/IEC-60947-3, 1999 SP, DP, TP & FP AC 22 A 240/415 V AC 40 125 Amp DC MCB Specifications No. of Poles Rated Current Rated Voltage Rated short circuit breaking capacity Insulation Voltage Degree of protection Mounting Position Connecting Terminals Electrical Service Life Impact Resistance ISOLATOR Specifications No. of Poles Utilization Category Rated Current Rated Voltage

DIMENSIONS MCB & ISOLATORS 0.5A to 63A MCB & ISOLATORS 80A to 125A Single Pole MCB with Auxiliary Switch All dimensions are in mm