Kingspan KS1150 TL Wall & Ceiling

Similar documents
Insulated Roof & Wall Panels. Product Data Sheet. Trapezoidal Insulated Roof Panels KS1000 RW

ALUMINIUM. Product Data Sheet

Master Panel 1000 W Wall

Master Panel 1000 R5 Roof

Longspan. Insulated Panels. Architectural Frame to Frame Insulated Panel System. CI/SfB (4-) Rh2 September 2008

CERTIFICATE NAME OF PRODUCT MANUFACTURER PRODUCT DESCRIPTION CERTIFICATION PROCEDURE. No VTT C Date of issue , Updated July 1, 2011

Composite Panel Firewall Systems

Architectural composite panels

STEEL BUILDINGS IN EUROPE. Single-Storey Steel Buildings Part 8: Building Envelope

BETONYP building boards. The modern way of living.

Steel Panel Frame. Exterior Steel Sheeting. Optional Rigid Insulation. Optional Steel Insulation Liner

ENVIRONMENTAL INFORMATION APR 1200 products are made from glass mineral wool, one of the most environmentally friendly insulants available.

INSTALLATION. General. Important Note. Design. Transport

HIGH PERFORMANCE PRE-APPLIED SYSTEM FOR BLIND SIDE & BELOW GRADE WATERPROOFING APPLICATIONS

Hoesch Matrix System individuell. ThyssenKrupp Steel Europe Thinking the future of steel

Double Coated Urethane Foam Tapes

VXT. Open Cooling Towers. Open Cooling Towers. Product Detail VXT - B 1. Engineering Data... B2. Structural Support... B6

STENCA PIPE. High quality pipe insulation.

Prefabricated building PVC vertical sliding window

Steel-framed Walls. Insulation

Section 5.0. Basements. Wall insulated externally. Wall insulated internally. Ba02. Product: Polyfoam ECO Floorboard Ba01.

PROPOSED SPECIFICATION FOR ALUCOBOND PLUS Aluminium Composite Panel Cladding System Fixed Watertight Cassette Panel System - 4mm thick

Rockwool Flexi Insulation Application Guide

Product Data Sheet ROCKPANEL Rockclad

Cavity Drain R20 is manufactured from1.0mm thick black high density polyethylene with studs approximately 20mm high.

European Technical Approval ETA 13/0526

Mold Preventing I nterior System

Colonnade Security Pipe

Kingspan Roof Tile. Insulated Panels. Insulated Tile Effect Roofing System. Building to the Power of. CI/SfB. September 2008

TR21. I n s u l a t i o n. Low Energy Low Carbon Buildings

Low Energy Low Carbon Buildings

ROXUL Board Insulation Section Master Guide Specification (CAVITYROCK ) Page 1 April 2016

Low Energy Low Carbon Buildings

1.1.2 Polypropylene The polypropylene must be a white opaque film, 1 2 mil thick. Biaxial orientation is preferred.

COMMERCIAL BUILDING APPLICATIONS

Fire 2This Technical Bulletin has been commissioned by the UK SIP Association in

Light Architecture. Colors Sweden. Light

All Weather Hall. Efficient, multipurpose & quick to build

INNOVATIVE. ADAPTABLE. ENERGY EFFICIENT.

ORAY PREFABRICATED GSM SHELTER CONTAINERS TECHNICAL SPECIFICATIONS

Cardok Sàrl CP37 CH-1295 Tannay Switzerland Phone:

SECTION PRE-ENGINEERED BUILDING BLANKET INSULATION

Dubai Municipality Standard DMS 1: Part 5: 2004

SOHOline and SOHO Slimline The SOHOline and SOHO Slimline offer a modular, sturdy and compact design

Approved. Property Test/Standard Description. matt (0-35) Flash point ISO 3679 Method 1 27 C calculated IED (2010/75/EU) (calculated)

Testing Rules for Thermal Conductivity October 2015

foot skylight) is enough to knock a worker off their feet. A 10 mph wind gust on a 5 x 6 skylight develops a wind force of 270 lbs.

Dow Corning PROPRIETARY. Dow Corning. A Thermal Modelling Comparison of Typical Curtain Wall Systems

Uniclass L31:N14:P7111 C1/SfB (16.9) Rn7 (J4) February Foundation Heave Protection

Guide Specification STAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM

TIGER Drylac U.S.A., Inc Swenson Avenue St Charles, IL T F office.us@tiger-coatings.us

!!!!!! !!! Decra Plus DPSW010 DPSTW011 DPSW012 DPSW013 DPSW014 DPSW015 DPSW016 DPSW020 DPSW021 DPSW024 DPSW030 DPSW031 DPSW035 DPSW030 DPSW031 DPSW035

RESIDENTIAL ROOFING & RE-ROOFING, ROOF VENTILATION AND ROOF SHEATHING REQUIREMENTS MICHIGAN RESIDENTIAL CODE 2000

HDA

STAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM

TPM 006/99 Revision 1 VALID FROM: 8/2/2013 REPLACEMENT FOR TPM 006/99 FIRE SHUTTER

INTERIOR WALLS AND BASEMENTS CHOOSING THE RIGHT MEMBRANE FOR INTERIOR WALLS. Multi-Layer Technology provides increased strength.

Data Sheet VITOSOL 100. Flat collectors for the utilisation of solar energy. Vitosol 100. Part nos. and prices: see price list

Unbeatable energy efficient glass curtain wall system

Cable ladder installation at S.C.M. Chemicals Limited s titanium dioxide Plant in Western Australia

Colours from Kingspan

RPV - RP - RA air handling units

CEILING SYSTEMS. CI/SfB (35) Xy April [Between us, ideas become reality.] ULTIMA CANOPY. Data sheet. Acoustic performance meets High Design

Physically Crosslinked Foam Insulation

The Kingspan Insulation Price List 1 st January 2013

Peel & Seal Self-Stick Roofing Solutions

Morgue refrigeration unit

Module 3.7. Thermal bridging

ProRox Slabs (formerly known as RW slabs)

How To Buy A Designo Grille

FERMACELL Powerpanel H 2 O for Wet & Moisture affected areas

Company DUOL. Dušan Olaj CEO

Kingspan Envirodek Structural Green Roof System

PRODUCTBLADEN GT ROCKPANEL STRUCTURE

Confort 26. Sliding Systems. Sapa Building System

City of San Diego, CWP Guidelines

Dot matrix Label ID Products. C Vinyl cloth labels. Dot Matrix. Features and benefits. Part numbering system

Rockwool Cladding Roll

PART 1 GENERAL 1.1 SECTION INCLUDES

CERTIFICATE OF APPROVAL No CF 291 SCHOTT UK LIMITED

Storage Store the siding in a dry and ventilated area. Do not place it directly on the ground. Always cover the siding after a day s work.

SECTION ALUMINUM FRAMED ENTRANCES and STOREFRONTS. System 402 Flush-Glazed Screw Spline Storefront

Passive Fire Protection

NEW ELECTRICAL SUBSTATION Building 300 SECTION ETHYLENE-PROPYLENE-DIENE-MONOMER ROOFING WORK

Lindab Coverline TM. Lindab Tile Effect Roofing. Make a lasting impression

AMF Line; wall absorbers Wall mounted acoustic designs PERFORMANCE CEILINGS. M ore s c op e f or i n n ovat i on MADE IN GERMANY

Pile Seal for insect screen

TECHNICAL RECOMMENDATION

EXPANDED POLYSTYRENE (EPS) INSULATION BOARD SPECIFICATIONS

Multi-layer Insulation Blanket for Roofs

Asphalt Shingle Application Requirements

I-Line - Snap-On Feature

Knauf Aquapanel Interior. Tile Backing. Cement board for wet areas. Will not deteriorate in water. Easy to score and snap

COMMERCIAL ITEM DESCRIPTION PACKAGING MATERIAL, SHEET

SPREFIX SPRAY INSULATION _ in the marine market.

Contents. APA Construction Details. Full fill cavity walls Partial fill cavity walls Solid externally insulated walls 26-37

European Technical Approval ETA-12/0500

CRN A-F-G-E-HQQE 3x400D 50 HZ

FIRE RATED GLAZING System Guide

Ubiflex. Non-lead flashing system

Transcription:

Kingspan KS1150 TL Wall & Ceiling APLICATIONS The KS1150 TL wall & ceiling system is through-fix solution (fasteners are visible on the external surface of panels). The panels can be laid vertically or horizontally and are suitable for external and internal applications as wall OR ceiling elements on all type of buildings. The KS1150 TL panels are especially recommended for temperature controlled applications. DIMENSIONS & WEIGHT Panel thickness (mm), sheet 0.5/0.5 mm 100 120 150 170 180 200 Weight (kg/m 2 ) KS1150 TL 12.49 13.29 14.49 15.29 15.69 16.49 Product Data Sheet Kingspan IPN / INN core Wall & Ceiling Panel KS1150 TL 1

Product Tolerances Panel length Tolerance For panel length under 3m + 5 mm - 4 mm Panel length is equal or over 3m + 10 mm - 7 mm Panel width ±2 mm Thickness Panel thickness D 100mm ±2 mm Panel thickness D 100mm ±2% Right angle cut end tolerance Max. 7 mm Panel bowing 10 mm Length-wise 2mm for each meter of length, but not greater than 10mm Width-wise <10mm Available Lengths The standard panel length is between 2.00 and 13,50 meters. The maximum length of panels is 15.00 meters. MATERIALS - STEEL 1. Steel grades with the minimum performance of S280GD. Hot-dip zinc coated steel with 275g/m 2 of zinc, according to EN 10147:2000 or asymmetrical zinc coat of 190g/m 2. This can be finished with a number of coatings - polyester, PVDF, Plastisol and Foodsafe. 2. Austenic stainless steel grade 1.4301 according to EN 10088. Without any coating system, surface finish 2B (IIIc). Substrate thicknesses Standard external - sheet thickness 0.50 mm Standard internal - sheet thickness 0.50 mm. Other thicknesses are available by agreement with Kingspan. External Coating Options 1. Standard Polyester PES Polyester is a universal, economic coating system suitable for exterior and interior applications. The nominal coating thickness is 25 µm. The colour range is available according to RAL palette. Standard external colour range: RAL 9002, RAL 9010, RAL 9006, RAL 9007, RAL 1015, RAL 3000, RAL 3009, RAL 5010, RAL 6020, RAL 7016, RAL 7035. Standard internal colour range: RAL 9002, RAL 9010. Product Data Sheet Kingspan IPN / INN core Wall & Ceiling Panel KS1150 TL 2

2. Kingspan Spectrum Spectrum is a 60μm Polyurethane coated semi-gloss finish with a slight granular effect. It offers an outstanding durability- and weather resistance performance, excellent corrosion and UV-resistance as well as high color & gloss retention characteristics. Its superior flexibility enables high resistance against mechanical damages. Kingspan Spectrum is available in a wide range of solid and metallic colours. Furthermore it is free of chlorine, phtalates and plasticizers and 100% recyclable. 3. PVDF PVDF offers unequalled colour and gloss retention and good corrosion resistance. The nominal coating thickness is 25-35 µm. It can be used in climates with extremely high UV radiation combined with extreme temperatures and relative humidity. The standard colour range includes metallic silver. 4. Plastisol 200 µm Plastisol is a high performance coating system with a grains finish and a nominal thickness of 200 µm. Typical properties of Plastisol are excellent abrasion, high corrosion resistance, excellent flexibility and therefore very good scratch resistance. Internal Coating Options 1. Polyester Polyester coating with a nominal thickness of 15 µm and 25 µm. Standard internal colour range: RAL 9002, RAL 9010, Kingspan White. 2. Foodsafe The surface of this 120 150 µm thick polymer coating is non-toxic and resistant to mould, durable and easy to clean. The standard colour is white RAL 9010. INSULATION CORE IPN rigid insulation foam is a new type if Polyisocyanurate (PIR) rigid foam developed by Kingspan to achieve higher fire performance properties of products, providing the best-inclass insulation performance among other PUR and PIR products. Rigid IPN insulation foam is the closed cell rigid Isophenic foam, CFC and HCFC free (Zero ODP). Non Deleterious. IPN is fully cured highly cross-linked thermosetting polymer with a ring-like structure. Under normal conditions of use and temperatures, IPN do not emit noxious fumes or gases. The INN is the IPN rigid core with improved thermal performance(thermalsafe). Thermal conductivity - IPN: λ < 0,0224 [W/mK] Thermal conductivity - INN: λ < 0,0202 [W/mK] Density: 39 [kg/m 3 ] ± 10 % IPN is resistant to fungus and mould growth, will not sustain vermin and is non fibrous, odourless and non tainting. Product Data Sheet Kingspan IPN / INN core Wall & Ceiling Panel KS1150 TL 3

PERFORMANCE Thermal Insulation (the U-values indicated for panel width of 1150mm) U value W/(m 2 K) Panel Thickness IPN core panels U value W/(m 2 K) INN core panels (mm) λ= 0.0224 W/(m K) λ= 0.0202 W/(m K) 100 0.222 0.199 120 0.186 0.166 150 0.149 0.133 170 0.132 0.117 180 0.125 0.111 200 0.113 0.100 Biological KS1150 TL insulated sandwich panels are immune to attack from mould, fungi, mildew and vermin. The panels are non-deleterious. Fire Panel Thickness (mm) 100 120 150 170 180 200 Fire resistance Reaction to Fire IPN core INN core IPN core INN core EI30 Under testing B-s1,d0 Under testing For application details of particular fire resistance results please consult Kingspan Technical Department Acoustics Panel Thickness R W, db R A1, db R A2, db 100 26 23 22 120 27 24 22 150 26 25 22 170 26 25 22 180 26 25 22 200 26 25 22 Product Data Sheet Kingspan IPN / INN core Wall & Ceiling Panel KS1150 TL 4

Packing & Delivery Standard packing road transportation KS1150 TL panels are factory-packed according to panel dimensions to ensure arrival on site in pristine condition. Panels packed horizontally. Pack length varies according to product type and panel length. Typical palette height is 1,100mm, Maximum palette weight is 1300 kg. All packs labelled clearly identifying product type and pack weight. Whole pack protected with various materials Sheets of polystyrene at bottom, top and sides, Plastic hoods at both end Polystyrene blocks at the bottom with gaps for offloading using forklift, crane, Pack shrink wrapped in plastic film, secured with sticky tape The number of panels in each pack depends on panel thickness. The table below is shown as a guide. Panel core thickness (mm) 100 120 150 170 180 200 Number of panels in package 10 8 7 6 6 5 Delivery & Off-loading All deliveries (unless indicated otherwise) are by road transport to project site. It is the customer s responsibility to arrange lifting equipment and labour to unload the packs. This usually requires using a crane, with or without a lifting beam, or a forklift, depending on panel length and weight. Site Storage It is often necessary to store packs of panels on site for a period before they are fixed. To ensure that the panels remain in prime condition until they are installed the following precautions should be taken: Store packs off the ground and on a plain area. Support the packs evenly with timber bearers spaced at 1.5 metres. It is not allowed to store the KS1150 TL panels in piles (one above another). If packs cannot be kept in a building they must be covered with a weatherproof sheet ensuring that the sheet drains water away effectively and does not allow ponding on top of the pack. Store packs in a secure area, where they will not be damaged or stolen. Inspect the storage site and the packs regularly to ensure the panels remain in good condition. Do not store packs where people will walk across them. Product Data Sheet Kingspan IPN / INN core Wall & Ceiling Panel KS1150 TL 5

Walkability Generally it is not recommended to walk on composite panels. For repair & maintenance works considering one person with a tool box (max. 100kg), we recommend to use load spreader plates which will ensure better load distribution. In case of any damages through walking on panels without using spreader plates, Kingspan will not take any warranty. It is not allowed to store technical building equipment on the ceiling elements due to structural capacity. STRUCTURAL TABLES General load-span tables are at the end of the Data sheet please use this table only for guidance purposes. For detailed design cases please contact Kingspan Technical Department for exact static calculations due to project specific requirements QUALITY & WARANTIES Quality Kingspan insulated sandwich panels are manufactured from the highest quality materials, using state of the art production equipment to rigorous quality control standards, complying with ISO9001:2000 standards, ensuring long term reliability and service life. Building Regulations Kingspan KS1150 TL insulated sandwich panels conform to the National Building Regulations and standards. Guarantees & Warranties Kingspan will provide external coating and product guarantees on a project by project basis. Certification Kingspan KS1150 TL panels have been tested and certified according to EN 14509, and are labelled with CE mark. Product Data Sheet Kingspan IPN / INN core Wall & Ceiling Panel KS1150 TL 6

Load tables (knm -2 ) - Wall panel KS1150 TL - single span 2013 04 16 Outer sheet type M t n (mm) 0,5 colour 2 Inner sheet type MB t n (mm) 0,5 Panel th.(mm) Span (m) 4 4,5 5 5,5 6 6,5 7 7,5 8 8,5 9 9,5 10 100 pressure 1,54 1,37 1,23 1,09 0,91 0,78 0,67 0,58 0,51 0,43 0,36 0,29 0,23 suction 1,57 1,24 1,00 0,83 0,70 0,59 0,51 0,45 0,39 0,35 0,31 0,28 0,25 a (mm) 40 40 40 40 40 40 40 40 40 40 40 40 40 120 pressure 1,62 1,44 1,30 1,18 1,08 0,93 0,81 0,70 0,62 0,55 0,49 0,44 0,39 suction 1,88 1,49 1,20 1,00 0,84 0,71 0,61 0,54 0,47 0,42 0,37 0,33 0,30 150 pressure 1,82 1,62 1,46 1,32 1,21 1,12 1,04 0,91 0,80 0,71 0,63 0,57 0,51 suction 2,43 1,92 1,55 1,28 1,08 0,92 0,79 0,69 0,61 0,54 0,48 0,43 0,39 170 pressure 2,02 1,80 1,62 1,47 1,35 1,25 1,16 1,06 0,93 0,82 0,73 0,66 0,59 suction 2,82 2,23 1,80 1,49 1,25 1,07 0,92 0,80 0,70 0,62 0,56 0,50 0,45 180 pressure 2,02 1,80 1,62 1,47 1,35 1,25 1,16 1,08 0,99 0,88 0,78 0,70 0,64 suction 3,03 2,39 1,94 1,60 1,35 1,15 0,99 0,86 0,76 0,67 0,60 0,54 0,48 200 pressure 2,23 1,98 1,78 1,62 1,48 1,37 1,27 1,19 1,11 1,01 0,90 0,80 0,73 suction 3,44 2,72 2,20 1,82 1,53 1,30 1,12 0,98 0,86 0,76 0,68 0,61 0,55 -Notice: -the load span tables in this document are calculated according to EN 14509 -the other profilations and dark colours have to be discussed with producer -the table comprises permissible characteristic values of live load (kpa) at given span -the tables is valid for a short- time live loads (for example wind load) and comprises the influences of winter and summer temperatures in the central Europe. -the deflection limit for panels is set as L/100 - (a) - the minimum width of end support given in [mm] Product Data Sheet Kingspan IPN / INN core Wall & Ceiling Panel KS1150 TL 7

Load tables (knm -2 ) - Wall panel KS1150 TL - double span 2013 04 16 Outer sheet type M t n (mm) 0,5 colour 2 Inner sheet type MB t n (mm) 0,5 Panel th.(mm) Span(m) 1,5 1,75 2 2,5 3 2,5 4 4,5 5 5,5 6 6,5 7 100 Pressure 2,06 1,72 1,48 1,17 0,97 1,17 0,74 0,66 0,60 0,55 0,51 0,48 0,43 Suction 6,71 5,63 4,85 3,80 2,78 3,80 1,57 1,24 1,00 0,83 0,70 0,59 0,51 a (mm) 40 40 40 40 40 40 40 40 40 40 40 40 40 b (mm) 80 80 80 80 80 80 80 80 80 80 80 80 80 120 Pressure 1,51 1,25 1,07 0,83 0,70 0,83 0,54 0,48 0,44 0,41 0,38 0,35 0,33 Suction 6,90 5,78 4,97 3,89 3,20 3,89 1,87 1,48 1,20 0,99 0,83 0,71 0,61 a (mm) 40 40 40 40 40 40 40 40 40 40 40 40 40 b (mm) 80 80 80 80 80 80 80 80 80 80 80 80 80 150 Pressure 2,51 2,08 1,78 1,38 1,14 1,38 0,85 0,76 0,69 0,64 0,59 0,55 0,51 Suction 8,91 7,47 6,42 5,00 4,09 5,00 2,42 1,91 1,55 1,28 1,07 0,92 0,79 b (mm) 120 120 120 120 120 120 120 120 120 120 120 120 120 170 Pressure 2,86 2,38 2,03 1,57 1,28 1,57 0,96 0,85 0,77 0,71 0,65 0,61 0,57 Suction 10,27 8,61 7,40 5,75 4,70 5,75 2,81 2,22 1,80 1,48 1,25 1,06 0,92 b (mm) 120 120 120 120 120 120 120 120 120 120 120 120 120 180 Pressure 2,86 2,37 2,02 1,56 1,27 1,56 0,95 0,85 0,77 0,70 0,65 0,60 0,56 Suction 10,95 9,19 7,89 6,13 5,01 6,13 3,02 2,38 1,93 1,60 1,34 1,14 0,99 b (mm) 120 120 120 120 120 120 120 120 120 120 120 120 120 200 Pressure 3,22 2,67 2,27 1,75 1,43 1,75 1,06 0,94 0,85 0,78 0,72 0,67 0,62 Suction 12,32 10,34 8,89 6,91 5,64 6,91 3,43 2,71 2,19 1,81 1,52 1,30 1,12 b (mm) 120 120 120 120 120 120 120 120 120 120 120 120 120 -Notice: -the load span tables in this document are calculated according to EN 14509 -the other profilations and dark colours have to be discussed with producer -the table comprises permissible characteristic values of live load (kpa) at given span -the tables is valid for a short- time live loads (for example wind load) and comprises the influences of winter and summer temperatures in the central Europe. -the deflection limit for panels is set as L/100 - (a) - the minimum width of end support given in [mm] - (b) - the minimum width of intermediate support given in [mm] Product Data Sheet Kingspan IPN / INN core Wall & Ceiling Panel KS1150 TL 8