Optical Spectrum Analyzer AQ-6315A/-6315B. The Next Standard

Similar documents
A compact, lightweight, portable optical spectrum analyzer for DWDM system installation and maintenance.

Technical Datasheet Scalar Network Analyzer Model MHz to 40 GHz

HP 70950B OPTICAL SPECTRUM ANALYZER

khz to 2.7 GHz Spectrum Analyzer

Agilent E5100A Network Analyzer

Module 13 : Measurements on Fiber Optic Systems

Agilent 8757D Scalar Network Analyzer 10 MHz to 110 GHz

HDO700 P FIBRE OPTIC TRANSMITTER

Agilent 8509C Lightwave Polarization Analyzer

Agilent N8973A, N8974A, N8975A NFA Series Noise Figure Analyzers. Data Sheet

Impedance 50 (75 connectors via adapters)

Agilent E6020B FTTx OTDR

Nederland België / Belgique

Experiment 5. Lasers and laser mode structure

Plug - Type (Male/Female) Attenuators CAA series Singlemode

AQ7275 OTDR Optical Time Domain Reflectometer

Spectrum Analyzers. R9211Series. R9211A/9211B/9211C/9211E FFT Analyzer Series. Choice of 4 Types To Fit the Application

DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

HIGH POWER FREE SPACE AND FIBER PIGTAILED ISOLATORS

palmotdr Series Handheld OTDR

Handheld Spectrum Analyzers, 3.3 GHz & 8.5 GHz Models 2650A, 2652A, 2658A

We bring quality to light. MAS 40 Mini-Array Spectrometer. light measurement

Optical Power Meter. Specification & User Manual

FFT Spectrum Analyzers

Power Amplifier Gain Compression Measurements

Physical Specifications (Custom design available.)

Agilent Cary 60 UV-Vis

Fiber Optic Light Sources

POLARIZATION EXTINCTION RATIO METER

Kit Highlights and Key Features

CISCO DWDM XENPAK. Main features of the Cisco DWDM XENPAK include:

AMPLIFIED HIGH SPEED FIBER PHOTODETECTOR USER S GUIDE

VARIABLE FIBER OPTIC ATTENUATORS BLOCKING PIGTAIL STYLE

R&S ZVA Vector Network Analyzer Specifications

A Guide to Calibrating Your Spectrum Analyzer

FIBRE-OPTICS POWER METER INSTRUCTION MANUAL

L-LAS-TB-CL serie. laser light curtains for inline measuring tasks

Spectrum Analyzer Two models available: OGR-24 (24 GHz) and OGR-8 (8 GHz)

Measuring of optical output and attenuation

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

Agilent AN 1316 Optimizing Spectrum Analyzer Amplitude Accuracy

R&S ZNC Vector Network Analyzer Specifications

Raptor RXi Ultra-fast scanning Countersurveillance Receiver

Microwave. 6200B series RF and Microwave Test sets.

MTS/T-BERD Platforms Very Long Range (VLR) OTDR Module

R&S ZNBT8 Vector Network Analyzer Specifications

MS9710B/MS9710C Optical Spectrum Analyzers DWDM Measurement Solutions

Agilent Technologies 3000 Series Oscilloscopes

Multi-Range Programmable DC Power Supplies 9115 Series

M-D,T,Q-series BroadLighter. Benchtop Broadband Light Source with Extended Bandwidth. Technical Product Specification

Cond-IS RF Conducted Immunity System

Adding Pneumatic Preset Counter. Type 497. Continuously visible preset Integrated pneumatic reset 3 or 5-digit display Convenient button setting

FREQUENCY RESPONSE ANALYZERS

Agilent Cary 4000/5000/6000i Series UV-Vis-NIR

Network analyzer and spectrum analyzer two in one

One Port Network Analyzer

ST800K-U Optical Power Meter. User Manual V1.0

Fast and Accurate Test of Mobile Phone Boards

Application Note Noise Frequently Asked Questions

High Power and Low Coherence Fibre-optic Source for Incoherent Photonic Signal Processing

Advanced Test Equipment Rentals ATEC (2832)

AN Application Note: FCC Regulations for ISM Band Devices: MHz. FCC Regulations for ISM Band Devices: MHz

Fiber Optic Distributed Temperature Sensor (B-DTS)

How To Sell A Talan

GOOD WILL Instrument Co., Ltd. All rights reserved.

Type-D EEG System for Regular EEG Clinic

Adjustment functions for both span and shift have been incorporated

Making OSNR Measurements In a Modulated DWDM Signal Environment

1. Oscilloscope is basically a graph-displaying device-it draws a graph of an electrical signal.

Agilent 8720 Family Microwave Vector Network Analyzers

Quasi-Continuous Wave (CW) UV Laser Xcyte Series

Optical Fibres. Introduction. Safety precautions. For your safety. For the safety of the apparatus

Agilent PN RF Component Measurements: Amplifier Measurements Using the Agilent 8753 Network Analyzer. Product Note

PCM Encoding and Decoding:

Agilent 8753ET/8753ES Network Analyzers

S2000 Spectrometer Data Sheet

Measuring Laser Power and Energy Output

U1602A Handheld Oscilloscopes, 20 MHz

EXPERIMENT NUMBER 5 BASIC OSCILLOSCOPE OPERATIONS

CellAdvisor. JD725A Dual-Port Cable and Antenna Analyzer

DC Electronic Loads 8500 series

SOUND LEVEL METER 94405

Laser diffuse reflection light scanner with background suppression. Dimensioned drawing

SINGLEMODE OR MULTIMODE FIBER OPTIC PATCHCORDS

KONSTANTER SPL / SPL Programmable Electronic Load

LED red (-): Measuring value < lower tolerance threshold LED red (+): Measuring value > upper tolerance threshold. Page 1/6

Model GS Port Node 1 GHz with 40/52 MHz split

Dash 18X / Dash 18 Data Acquisition Recorder

MPC 4. Machinery Protection Card Type MPC 4 FEATURES. Continuous on-line Machinery Protection Card

User's Guide. Integrating Sound Level Datalogger. Model Introduction

CX380X Advanced Spectrum and Burst QAM Analyzer

Spectrum Analyzer Two models available: OGR-24 (24 GHz) and OGR-8 (8 GHz)

Contents & P-LCD Modules Cross Reference Table

Wavelength Division Multiplexing

EE 186 LAB 2 FALL Network Analyzer Fundamentals and Two Tone Linearity

Field Calibration Software

Lab 9: The Acousto-Optic Effect

DIRECTIONAL FIBER OPTIC POWER MONITORS (TAPS/PHOTODIODES)

DDX 7000 & Digital Partial Discharge Detectors FEATURES APPLICATIONS

User s Guide DDS-3X25 USB ARBITRARY FUNCTION GENERATOR

Transcription:

Optical Spectrum Analyzer AQ-6315A/-6315B The Next Standard

The AQ-6515A/-6315B optical spectrum analyzer brings advanced capabilities to a wide range of applications, from light source evaluation to measurement of loss wavelength characteristics in optical devices. Featuring significant upgrades from the basic performance and functions of the prior AQ-6312A/-6312B models, they incorporate This equipment is available in two specification depending on the presence of the optical function MODEL AQ-6315A AQ-6315B OPTICAL OUTPUT FUNCTION a totally new monochrometer design. In spite of the compact case, they support single-pass/doublepass monochrometer mode select. In the double-pass monochrometer mode dynamic range is improved far beyond what it has even been before. In the single -pass monochrometer mode it supports the same wide range of applications as the prior models. The AQ-6315A/-6315B, bringing the full selection of advanced Ando spectrum analyzer technology to your work. a new standard for the industry. NO YES MAJOR FEATURES Diverse analysis functions Analysis functions for WDM and other optical devices (LD, LED, FBG, etc.). High wavelength accuracy Provides ±0.05 nm wavelength accuracy in the 1550 nm band, with ±0.02 nm wavelength linearity, makes it especially useful for WDM devices, such as high-precision loss wavelength characteristic evaluation. Monochromator select mode The monochro mode can be set to single-pass or double-pass to match your measurement application needs. High sensitivity over a wide band Covers from 350nm to 1750nm and noise level has been suppressed to allow the AQ-6315A/-6315B to measure light at down to 90Bm Low polarization dependency Polarization dependency has been slashed to ±0.05dB, enabling accurate measurement of optical amplifier gain and other critical measurements. High-level accuracy Accurate to within ±0.3dB. High-power measurement: Max.+20dBm (100mW) Even high power output from an optical amplifier can be measured directly without an optical attenuator High wavelength resolution Achieves wavelength resolution of 0.05nm. Optical output is provided (AQ6315B only) Can be used as an optical bandpass filter. Three individual trace memories Pulsed light can be measured 9.4-inch color LCD

Manual-Free Operation 1-9.4-inch color liquid crystal display Displays all information such as measurement waveforms, measurement conditions and measured data. 2-Function keys and window menus Used to select and execute various measurement conditions, corresponding to main functions switches. 3-Main function select switch All measurement settings 4-Data entry selection Used to input data, such as rotary knob, step key and ten-key pad. 5-Optical input connector 6-3.5-inch floppy disk drive Supports both 1.2MB and 1.44MB disks. Data can be saved on both text file and graphic file (BMP, TIFF) formats. 7-Intensity Adjust the display intensity. 8-Power switch 9-Help key Used to verify the actions of various function keys. 10-Used to output data to the internal printer and external plotter. 11-Internal printer Used to quickly output screen had copies.

WDM device characteristics evaluation This system calculates key data such as peak wavelength, frequency separation, peak level and SNR for each channel for up to 99 channels, based on the WDM transmission optical spectrum. SNR is the difference between level and noise level for each channel peak. Application Optical fiber amplifier (EDFA) characteristic evaluation The ASE interpolation method is used to measure gain and NF, key parameters for optical fiber evaluation. When used with the AQ8423A/8423B optical amplifier analyzer, the system can accurately measure gain and NF with the pulse method, which is optimum for evaluation of WDM transmission optical fiber amplifiers. Example of measurement in combination with optical amplifier analyzer

Application Parameter evaluation for LED, FP-LD and FB-LD. One-touch evaluation of key parameters for LED, FP-LD and DFB-LD such as side mode suppression ratio for DBF-LD. Color analysis color analysis for color PDP, color LCD, color CRT, and visible LED and LD. The spectral diagram can also be displayed Pulse light measurement Offers three pulse light measurement functions (LPF, peak hold, external trigger). Select the appropriate mode for your repeating frequency. Wide-region optical device evaluation The level axis can be set to dbm/nm (power density: Power per nm) to display true wide-region light source level, independent of resolution.

Application Fiber grating characteristics evaluation When used in combination with the AQ2141 expansion frame and the AQ4310 (155) ASE unit. It is possible to evaluate performance such as notch width for fiber grating transmission spectrums. Optical filter loss evaluation When used in combination with the AQ4303B white light source and the AQ9314B parallel beam mount, it is possible to evaluate transmission characteristics of optical filters. (% Display) Optical fiber loss wavelength characteristics When used in combination with the AQ4303B white light source, it is possible to evaluate optical fiber loss-wavelength characteristics. Also the arithmetic function can convert optical fiber loss wavelength characteristics into loss per unit length for display.

Specifications Single-pass monochromator mode Double-pass monochromator mode Applicable fiber SM to 800µm diameter fiber SM, GI (50/62.5µm) Measurement wavelength range 350 to 1750nm Wavelength span 0 to 1500nm Wavelength accuracy ±0.5nm (25 ± 5 C, 10/125 SM fiber) ±0.05nm (1510 to 1570nm, 10/125 SM fiber) Wavelength linearity ±0.02nm (1510 to 1570nm, 10/125 SM fiber)[1] Wavelength reproducibility ±0.005nm (1 minute) Wavelength resolution 0.05 to 10nm Measurement level range [2] -90 to +20dBm (1000 to 1600nm) -85 to +20dBm (600 to 1000nm) -75 to +20dBm (350 to 1750nm) -85 to +20dBm (1200 to 1600nm) -80 to 20dBm (600 to 1200nm) -65 to +20dBm (350 to 1750nm) Level accuracy [3] ±0.3dB (at 633/1310/1550nm) Polarization dependency [4] ±0.1dB (at 1310/1550nm) ±0.05dB (at 1310/1550nm) Linearity [5] ±0.05dB (0 to -40dBm), ±0.2dN (0 to 60dBm) Level scale 0.1 to 10dB/div. And linear Dynamic range (stray light level) [6] 40dB (± 1nm, 633/1152/1523nm 35dB (± 0.5nm, 633/1152/1523nm) 70dB (± 1nm, 633/1152/1523nm) 60dB (± 0.5nm, 633/1152/1523nm) Sweep time [7] 0.5 s. or less (span 500nm or less) 2.5 s. or less (full span) Measurement Automatic measurement, marker-to-marker sweep measurement, averaging, pulsed light measurement function. Power meter function Display 3D display, split (dual) display Functions Individual 3 trace memories Max./min. hold, data calculation (addition, subtraction, division), normalize, Dominant, curve-fit display, power density display function, dbm/km, % level scale Data analysis Peak/bottom searches, specral width search, SMSR search. Marker to marker power measurement function, optical amplifier NF measurement function, color analysis function, WDM analysis function, notch width measurement function Other Program function (200 steps 20 programs), wavelength calibration function, calendar/date function, help function, user key define function, label function Resolution setting range: 0.05 to 10nm Optical output [8] Insertion loss: 20dB or less (1310/1550nm) Optical fiber: GI 50/125µm Memory FDD Traces, analysis data and programs on 3.5-inch FD (1.2/1.44Mbyte) Internal memory Traces and measurement conditions (32 traces), 20 programs Data Output Printer High-speed built-in printer Plotter Direct output to XY plotter GP-IB 2 ports Interfaces Other Sweep trigger input (TTL), sample trigger input (TTL), sample trigger output (TTL) Sample enable input (TTL), 270Hz output (TTL), analog output (0-5V), Video output (VGA compatable) Display 9.4-inch color LCD, resolution 640 480 dots Optical input connector FC (standard) SC, D4, W/E, ST, DIN, etc. Power requirements AC100V to 120V, 200V to 240V, 48 to 83Hz, approx. 200VA Operating temperatures: 5 C to 40 C Environment Storage temperatures: -10 C to 50 C Humidity: 80% or less (no condensation) Dimensions and mass Approx. 425 (W) 222 (H) 450 (W) mm, approx. 30kg Accessories Power cord: 1ea, 3.5-incn FD: 2ea, recording paper: 2ea, instruction manual: 1ea Note that device adapters, quartz cells for liquid measurement, parallel beam mounts, and white light sources are optional. Please consult with your vendor separately. *These specifications are for products delivered later than October 1997 NOTE: [1] After power-on and more than two hours of warm-up, within 24 hours from wavelength calibration with 1523nm HE-NE laser. [2] At 25 ± 5 C. Resolution 0.5nm or more. [3] 10/125 SM fiber, 25 ± 5 C, input level -30dBm or more [4] 10/125 SM fiber, 25 ± 5 C, resolution 0.5nm or more [5] 25 ± 5 C, sensitivity HIGH 3. [6] 10/125 SM fiber, 25 ± 5 C, resolution 0.05nm, excluding high-order and low0order harmonics [7] Single-trace display, sampling points: 501, sensitivity NORMAL HOLD. Average time: 1, no changes of diffraction order within sweep range except the full span [8] AQ6315B only Specifications are subject to change without notice.