ASCII Server - BACnet/IP Client. Gateway for integration of BACnet IP devices into ASCII enabled control systems.

Similar documents
IntesisBox ASCII Server - LON

IntesisBox Modbus Server Fidelio IP

ModBus Server - KNX. Gateway for integration of KNX equipment into Modbus (RTU and TCP) control systems.

Modbus Server SAMSUNG Air Conditioners

IntesisBox KNX - LON

IntesisBox Modbus Server SAMSUNG Air Conditioners

IntesisBox KNX LG Air Conditioning

IntesisBox KNX Modbus RTU master

IntesisBox Modbus Server - Mitsubishi Electric G50

IntesisBox KNX Modbus TCP master

IntesisBox. KNX SAMSUNG Air Conditioning. Gateway for integration of Samsung air conditioners into KNX control systems. RS485.

KNX Panasonic Air Conditioners

IntesisBox KNX Mitsubishi Heavy Industries AC

IntesisBox. Making Building Automation go further. Modbus Products

IntesisBox. Making Building Automation go further. KNX EIB Products

Technical Note A007 Modbus Gateway Vantage Pro2 25/09/2009 Rev. A 1 de 7

TCP/IP MODULE CA-ETHR-A INSTALLATION MANUAL

ROAMview to BACnet IP Software Module

PCS0100en Persy Control Services B.V. Netherlands

1 Serial RS232 to Ethernet Adapter Installation Guide

Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

Portable BACnet /IP to MS/TP Router

TRP-C31M MODBUS TCP to RTU/ASCII Gateway

BIT COMMANDER. Serial RS232 / RS485 to Ethernet Converter

Setup Manual and Programming Reference. RGA Ethernet Adapter. Stanford Research Systems. Revision 1.05 (11/2010)

User manual Compact Web PLC WP240 series IEC-line

TX OPEN RS232/485 module

BACnet router for BACnet/IP BACnet/LonTalk BACnet MS/TP

Tracer Summit Web Server

Vroom Hardware manual ver Code 114VROOHWE00. Vroom CANBUS USER INTERFACE WITH LCD GRAPHIC DISPLAY AND WITH TEMPERATURE AND HUMIDITY SENSOR

Cable Specifications and Information

Temperature & Humidity SMS Alert Controller

User Manual Revision English

Zlinx Wireless I/O. Peer-to-Peer and Modbus I/O B&B ELECTRONICS PRODUCT INFORMATION

INTRODUCTION FEATURES OF THE ICM

connecdim Gateway G1 Ethernet TCP/IP to DALI

To perform Ethernet setup and communication verification, first perform RS232 setup and communication verification:

SHEET. BASautomation. BAS Router BACnet Multi-Network Router. BAS Router

Industrial RS-232/ RS-422/ RS-485 over Ethernet Media Converter

EDI Distributor Control Interface Wiring and Setup Instructions

One Port Serial Server Users Manual Model ESP901, ESP901E

Product Description. Model VM 500 series [ VM508/VM508E ] Water Alarm. Telephone/Pager Alert Calls. Power Alarm. Maximum Number of Sensors

16-Port RS232 to USB2.0 High Speed Multi Serial Adapter (w/ Metal Case) Installation Guide

Telephone- and leased line modem for industrial applications TD-36

SUDT AccessPort TM Advanced Terminal / Monitor / Debugger Version 1.37 User Manual

User Manual Revision English Converter / Adapter Ethernet to RS232 / RS485 (Order Code: HD HD M HD HD M)

HMIGTO4310 advanced touchscreen panel 640 x 480 pixels VGA- 7.5" - TFT - 96 MB

Manual. IP Sensor and Watchdog IPSW2210. I P S W M a n u a l P a g e 1. Relay Output. Power input. 12VDC adapter LED Indicators. 2 Dry.

IPG/7700 Hardware Manual SYSTECH. Document number Revision A

Modbus and ION Technology

EZmoto V2. Product description Rev. 6 10/01/2014. EZmoto V2 Product description Rev.6 10/01/2014

HMI display Installation Guide

POS Integration. Prepared by: Binh Nguyen

ENERGY SOLUTIONS RESIDENTIAL STORAGE BATTERY SYSTEM

ZC-24DO CANopen I/O Module: 24 Digital Outputs

Industrial Ethernet Data Gateways

HWg-STE HWg-STE PoE MANUAL

Communication Capabilities via a Touch Screen or a Web Browser Further Expand Air-Conditioning Control Possibilities.

Communicate and view data from meters with one simple device

KNX IP Gateway. Light-Control R. User manual-ver.1 LC-IPGW-001. KNX Gateway. KNX/EIB Intelligent Installation Systems

Modbus Communications for PanelView Terminals

Application/Connection Examples

GV-Data Capture V3 Series User's Manual

LGAC-KNX PROGRAMMING MANUAL. Integrations V1.0 TECHNICAL SUPPORT. Tel (+34)

LS-101 LAN to Serial Device server. User s Manual

IntesisBox. Making Building Automation go further. OPC Servers

Customer Pole Display SERIES 8035

Smarthome SELECT Bluetooth Wireless Stereo Audio Receiver and Amplifier INTRODUCTION

GPRS M-Bus Master. User Manual. An Economical and Practical Solution For Remote Automactic M-Bus Smart Meter Reading by GPRS In The Worldwide!

alpha DSL WTM HS Instructions for use ADSL modem alpha DSL WTM HS

User Manual. EtherUSB

Application. Characteristics RTU560. Data Sheet Communication Unit 560CMD11. Communication Unit 560CMD11

PLC training panel (Twido version)

USER MANUAL. VS-81H 8x1 HDMI Switcher MODEL: P/N: Rev 4

Loop-IP6702 TDMoEthernet

Knowledge Base POS/C31A Troubleshooting

5GHz 300Mbps 13dBi Outdoor CPE

Cisco Aironet Wireless Bridges FAQ

CENTRONICS interface and Parallel Printer Port LPT

SIP Proxy Server. Administrator Installation and Configuration Guide. V2.31b. 09SIPXM.SY2.31b.EN3

The Answer to the 14 Most Frequently Asked Modbus Questions

Users manual. TCW181B-CM_R1 Page 1

MODBUS TCP to RTU/ASCII Gateway. User s Manual

Unpacking the Product. Rack Installation. Then, use the screws provided with the equipment rack to mount the firewall in the rack.

C24-CAMANL Video Server/Encoder

Network Management Card

USER GUIDE. Ethernet Configuration Guide (Lantronix) P/N: Rev 6

DCS Data and communication server

SVA025 Netcom2 FAQ Rev 1. Mitsubishi Netcom 2 FAQ

INDUSTRIAL GATEWAYS VPN ROUTERS SERIAL DEVICE SERVERS

ETHERNET WEATHER STATION CONNECTIONS Application Note 33

KSH-3000-MI. Swipe Card Reader. ( Magnetic / IC Card two in One Reader ) Revision Reason Date V

Carbon Monoxide (CO) Gas Detection and Control System

NC-12 Modbus Application

T3 Mux M13 Multiplexer

Communication standards and Carel solutions

Industrial Bar Code Scanners

WinCON8000-R2/R8. Hardware User s Manual

5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual

Transcription:

IntesisBox ASCII Server - BACnet/IP Client Gateway for integration of devices into ASCII enabled control systems. Integrate Daikin VRV Air Conditioners into your ASCII enabled control system (AM, Crestron, LiteTouch ) "talking" simple ASCII messages. ASCII device ASCII enabled control system RS232 IntesisBox Ethernet LAN TCP/IP device LinkBoxBacnet Configuration Software RS232 Only needed for configuration Points in BACnet can be read/written from an ASCII enabled control system using simple text messages. IntesisBox is a client device allowing read/write points of other device(s) connected to a BACnet network, and offering these point's values through its ASCII interface. ASCII interface of IntesisBox uses serial RS232 communication (baud rate configurable). For this application Daikin VRV system must be equipped with Daikin BACnet gateway DMS502B51. BACnet interface of IntesisBox supports reading of other BACnet devices by continuous polling or by subscription requests (COV). All the updated readings are maintained in IntesisBox's memory ready to be served to the ASCII system when requested. IntesisBox can be configured to notify to the ASCII system whatever change of value detected for a point by means of spontaneous messages sent through the ASCII interface. This is configurable individually per point (no need of continuous polling by the ASCII control system). The configuration of the IntesisBox is done with LinkBoxBacnet, a friendly software configuration tool for Windows supplied along with IntesisBox with no additional cost. With the installation of LinkBoxBacnet, a Demo project for integration an ASCII system is also installed, using this demo project makes the engineering needed for this integration easy and quick.

IntesisBox capacity Element Max. (Basic version) Max. (Extended version) Notes Type of BACnet devices Only those supporting BACnet ASHRAE 135 2001 Annex J - BACnet/IP protocol, commonly referred as BACnet/IP. BACnet points supported 500 7000 Maximum number of points that can be defined into IntesisBox. devices supported 1 16 Maximum number of different devices that can be defined into IntesisBox (to read/write points into them). There are two different models of IntesisBox ASCII Server - BACnet/IP Client with different capacity every one of them. Basic version with capacity of 500 points and 1 BACnet/IP device. Ref.: IBO-ASCII-BAC-A Extended version with capacity of 7000 points and 16 BACnet/IP devices. Ref.: IBO-ASCII-BAC-B

Sample applications Integration of any BACnet device or system into ASCII enabled control systems. IntesisBox sends and receives text messages (ASCII characters) with a predefined format (see below specifications of this format), the system monitoring / controlling connected to the RS232 port of IntesisBox must be programmed to read and write those messages in the required format. ASCII enabled control system ASCII RS232 IntesisBox Ethernet LAN TCP/IP device device Control system with ASCII master interface. BMS. SCADA. PLC. AM. Crestron. LiteTouch. Typical BACnet devices or Systems equipped with BACnet interface: Heaters. Air conditioners. Lighting control. Access control. Fire detection systems. ASCII System supervising / controlling Full supervision and control System under supervision / control

Typical application Integration of Daikin VRV Air Conditioning system into ASCII enabled control systems (AM, Crestron, LiteTouch ). For this application, Daikin VRV Air Conditioning system must be equipped with Daikin BACnet gateway (model DMS502B51), this Daikin gateway is normally commissioned by Daikin technical personnel, contact your nearest Daikin distributor for details. In the technical documentation of IntesisBox supplied with the device, extended details on how to configure IntesisBox for this application is provided. Intesis Software provides sample projects for IntesisBox with specific configuration to integrate Daikin VRV system, with these sample projects the configuration and commissioning of IntesisBox for this application becomes easy and quick, almost plug & play. Indoor units DIII-NET Outdoor units Ethernet DMS502B51 ASCII master device IntesisBox ASCII Server - client

ASCII interface of IntesisBox Type of communication supported Serial RS232 (DB9 male connector, DTE). Baud rate configurable from 1200 to 57600 bps. 8 data bits, no parity, 1 stop bit. Data Format All ASCII messages are always of fix format and associated to point's internal addresses, not matter the parameters of the external point associated. This m eans that there is no need to change the ASCII control s ystem m essages used whenever the BACnet configuration changes. When this happens just change the configuration of the gateway and that's all, the ASCII control s ystem programm ing rem ains exactl y the sam e. Message to read a point's value: >Daaaa?\r aaaa is a 4 digits number indicating the internal point's address inside IntesisBox. \r means carriage return character (HE 0D, DEC 13). Message to write a point's value: >Daaaa=vv\r aaaa is a 4 digits number indicating the internal point's address inside IntesisBox. vv is the desired value for the point (it can be just integer or fractional, decimal point is used to separate integer and fractional parts if the number is fractional). \r means carriage return character (HE 0D, DEC 13). Message informing about a point's value: >Daaaa=vv\r aaaa is a 4 digits number indicating the internal point's address inside IntesisBox. vv is the actual value of the point (it can be just integer or fractional, decimal point is used to separate integer and fractional parts if the number is fractional). \r means carriage return character (HE 0D, DEC 13). This type of message is sent spontaneously by IntesisBox when receiving a change from BACnet, or sent in response to a previous poll of the point. Messages to indicate erroneous actions: >E01\r Is returned when trying to read a point not configured in IntesisBox. >E02\r Is returned when trying to write a point not permitted to be written. Examples: >D0001?\r Message sent to IntesisBox to read value of point 1. >D0001=23.5\r Message sent by IntesisBox to inform about the actual value of point 1 (value=23.5). >D0001=24.5\r Message sent to IntesisBox to write a value of point 1 (value=24.5). Acknowledgment IntesisBox can be configured to respond with an ACK message after executing a successful write request (ACK message is >OK\r)

interface of IntesisBox Specifications BACnet Conformance Class Supported: Class 3 BACnet Standard Application Services Supported: ConfirmedCOVNotification Subscribe COV UnconfirmedCOVNotification ReadProperty WriteProperty Who-Is I Am Initiate Requests Executes Requests Data Link Layer Option:, (Annex J) No Segmented Requests/Responses Supported BACnet Standard Object Types Supported Object Type Property Description Analog Input Present Value Analog signal. i.e. Ambient temperature. Analog Output Present Value Analog signal. Analog Value Present Value Analog signal. i.e. Temperature set point value. Binary Input Present Value Digital signal. i.e. ON/OFF status. Binary Output Present Value Digital signal. i.e. ON/OFF command. Binary Value Present Value Digital signal. i.e. ON/OFF status/command. Multistate Input Present Value Multistate signal. i.e. Working mode status. Multistate Output Present Value Multistate signal. Multistate Value Present Value Multistate signal. i.e. Working mode command.

Configuration tool LinkBoxBacnet Visual engineering tool, easy of use, for gateway s configuration and supervision compatible with Microsoft Windows operating systems, supplied with the gateway free of charge. Multi-window tool allowing to supervise simultaneously the communication activity with both protocols (systems), real time values for all the signals allowing to modify any value (very useful for test purposes), console window showing debug and working status messages, and configuration windows to configure all the gateway s parameters and signals. Signals configuration in plain text files (tab separated) for easy and quick configuration using Microsoft Excel (very useful in projects with a lot of points). Allows configuring the gateway s parameters and signals while in off-line (not connected to the gateway). Connection to the gateway for download the configuration and supervision by using serial COM port of the PC (serial cable supplied with the gateway). Allows configuring all the external protocols available for IntesisBox BACnet series. Upgrades for this software tool available free of charge whenever a new protocol is added to the IntesisBox BACnet series. Multi-project tool allowing having in the engineer s PC the configuration for all the sites with different IntesisBox BACnet series gateways. Multi-language tool, all the language-dependent strings are in a plain text file (tab separated) for easy modification or addition of new languages. A list of system commands is available to send to the gateway for debugging and adjust purposes (Reset, Date/time consultation/adjust, Firmware version request ).

Mechanical & Electrical characteristics Enclosure Plastic, type PC (UL 94 V-0). Dimensions: 107mm x 105mm x 58mm. Color Light Grey. RAL 7035. Power 9 to 30Vdc +/-10% 1.4W. 24Vac +/-10% 1.4VA. Plug-in terminal bloc for power connection (2 poles). Mounting Surface. Wall. DIN rail EN60715 TH35. ASCII port 1 x Serial RS232 (DB9 male DTE). port 1 x Ethernet 10BT RJ45. LED indicators 1 x Power. 2 x Serial port (ASCII) activity (Tx, Rx). 2 x Ethernet port link and activity (LNK, ACT). Console port RS232. DB9 female connector (DCE). Configuration Via console port. 1 Firmware Allows upgrades via console port. Operational -40 C to +70 C temperature Operational humidity Protection RoHS conformity Certifications 5% to 95%, non condensing IP20 (IEC60529). Compliant with RoHS directive (2002/95/CE). CE 1 Standard cable DB9male-DB9female 1,8 meters long is supplied with the device for connection to a PC COM port for configuring and monitoring the device. The configuration software, compatible with Windows operating systems, is also supplied.

Dimensions Power + Ethernet port ASCII RS232 58 mm Console port 107 mm 105 mm Recommended available space for its installation into a cabinet (wall or DIN rail mounting), with space enough for external connections 100 mm 115 mm 130 mm