HORIZONTAL concerning the layout, editorial and technical content, this document needs revising. In order to harmonize all documents within



Similar documents
ANNEX 1 of Horizontal desk study 27 Brominated Flame Retardents

How To Test For Contamination In Large Volume Water

This study was performed by Patrick Sullivan and staff at TestAmerica Analytical Testing Corp., Westfield, MA, USA

SERUM FROM SWEDISH MEN A LONGITUDINAL STUDY.

TEST REPORT Page 1 of 9

III Analytical Methods

Fipronil Analysis By GC/XSD following Post-Extraction Gel Permeation Chromatography Cleanup

Procedia Environmental Science, Engineering and Management

A Navigation through the Tracefinder Software Structure and Workflow Options. Frans Schoutsen Pesticide Symposium Prague 27 April 2015

Automation of Solid Phase Extraction and Column Chromatographic Cleanup

Thermo Scientific HyperSep Solid Phase Extraction Method Development Guide

AUTOMATED SAMPLE PREP CAPITAL EXPENDITURE JUSTIFICATION REPORT

Aliphatic/Aromatic Separation of Extractable Petroleum Hydrocarbons in Solids or Water by Silica gel Fractionation

Organize Sanayi Bölgesi 21.Cadde No:1 ESKİŞEHİR FAX NO: Attention : Mustafa Günay (mgunay@doganglass.com)

Which analytical tools/instruments/techniques are used for POPs. A general walk through the analysis

LC-MS/MS, the new reference method for mycotoxin analysis

MEPS - Micro Extraction by Packed Sorbent Online SPE for GC and LC sample preparation - Extraction to injection in a single process

TargetQuan 3 Software. Leading the way in regulatory. POPs quantification. Bullet Bullet Bullet

Pesticide Analysis by Mass Spectrometry

Purification of reaction mixtures using flash chromatography.

6. ANALYTICAL METHODS

DETERMINATION OF PBDEs IN HUMAN BREAST ADIPOSE TISSUES BY GAS CHROMATOGRAPHY COUPLED TO TRIPLE QUADRUPOLE MASS

Pesticide residue analysis: New Trends. Michal Godula, Ph.D. EU Marketing Manager Food Safety & Environmental Thermo Fisher Scientific

Basics of SPE Technology & Mechanisms. Pieter Grobler, Sigma-Aldrich RSA

MICROORGANIC POLLUTANTS: ACTION NEEDED TO SIMPLIFY THEIR ANALYSIS

METHOD 8082A. POLYCHLORINATED BIPHENYLS (PCBs) BY GAS CHROMATOGRAPHY

Technical Report. Automatic Identification and Semi-quantitative Analysis of Psychotropic Drugs in Serum Using GC/MS Forensic Toxicological Database

Introduction. The following definitions may help you better understand the components of the data report.

Chemical analysis service, Turner s Green Technology Group

ORGANIC SAMPLE PREPARATION

Reference Materials for Environmental Performance Testing Dr Steve Wood Head of Regulatory and Legislative Services. ISPRA 25 June 2009

LC-MS/MS Method for the Determination of Docetaxel in Human Serum for Clinical Research

Determination of Haloacetic Acids and Dalapon in Drinking Water by SPE and GC/ECD*

Determination of PCDD/Fs in Environmental Samples using Accelerated Solvent Extraction (ASE) and GC-MS/MS

Pace Analytical e-report

Determination of Pesticide Residues in Drinking Water Using Automated Solid-Phase Extraction and Gas Chromatography with Nitrogen Phosphorus Detection

Extraction, Derivatization and Ultra-Sensitive GC/Triple Quadrupole Analysis of Estrone and Estradiol in Human Serum

The First Quantitative Analysis of Alkylated PAH and PASH by GCxGC/MS and its Implications on Weathering Studies

Beysan San. Sitesi Fuar Cad. No: 27/A Beylikdüzü/İstanbul FAX NO : Attention : Şükrü Ulus Aktaş (kalite@tufankablo.

: EUROPE, ASIA, AFRICA, AMERICA

METHOD 3545 PRESSURIZED FLUID EXTRACTION (PFE)

Oasis HLB Cartridges and 96-Well Plates

Chemistry 321, Experiment 8: Quantitation of caffeine from a beverage using gas chromatography

TOXIC CHEMICALS IN COMPUTERS EXPOSED

Fast, Reproducible LC-MS/MS Analysis of Dextromethorphan and Dextrorphan

PCBs DETERMINATION IN TRANSFORMER OIL BY SPE AND GAS CHROMATOGRAPHY ANALYSIS

1.2 This TAP is applicable to concrete, charcoal, coral, debris, wipes and soil.

PCB SPIU CLEANUP CAUSE AND EFFECT DIAGRAM. Bruce A. Bohnen Technical Director Integrated Chemistries, Incorporated 1970 Oakcrest Avenue, Suite 215

Guide to Reverse Phase SpinColumns Chromatography for Sample Prep

Hong Kong Green Label Scheme Product Environmental Criteria for Copying Machines, Printers, Fax Machines and Multifunctional Devices (GL )

Method 1668A Interlaboratory Validation Study Report. March 2010

Version 1.0 September, Jean W. Munch and Paul E. Grimmett

Innovative vs Traditional

Analysis of Organophosphorus Pesticides in Milk Using SPME and GC-MS/MS. No. GCMS No. SSI-GCMS Shilpi Chopra, Ph.D.

STANDARD OPERATING PROCEDURES

Air Sampling for Gases and Vapors. Patrick N. Breysse, PhD, CIH Peter S.J. Lees, PhD, CIH Johns Hopkins University

Name Lab #3: Solubility of Organic Compounds Objectives: Introduction: soluble insoluble partially soluble miscible immiscible

CCME. Reference Method for the Canada- Wide Standard for Petroleum Hydrocarbons in Soil - Tier 1 Method

Overview. Triple quadrupole (MS/MS) systems provide in comparison to single quadrupole (MS) systems: Introduction

CONFIRMATION OF ZOLPIDEM BY LIQUID CHROMATOGRAPHY MASS SPECTROMETRY

Biocides main groups

SPE, LC-MS/MS Method for the Determination of Ethinyl Estradiol from Human Plasma

Revision of ISO 9001 Quality Management Systems Requirements

Holcim EMR List of EN Standards and VDI Guidelines usable for Discontinuous Measurements in Cement Plants

Quantitative analysis of anabolic steroids in control samples from food-producing animals using a column-switching LC-HESI-MS/MS assay

Analysis of PCBs, Pesticides, and PAHs in Air and Precipitation Samples:

Analysis of Free Bromate Ions in Tap Water using an ACQUITY UPLC BEH Amide Column

Analytical Data Package Reports

Method development for analysis of formaldehyde in foodsimulant. melamine-ware by GC-MS and LC-MS/MS. Internal Technical Report

# LCMS-35 esquire series. Application of LC/APCI Ion Trap Tandem Mass Spectrometry for the Multiresidue Analysis of Pesticides in Water

METHOD 9075 TEST METHOD FOR TOTAL CHLORINE IN NEW AND USED PETROLEUM PRODUCTS BY X-RAY FLUORESCENCE SPECTROMETRY (XRF)

Daniel M. Mueller, Katharina M. Rentsch Institut für Klinische Chemie, Universitätsspital Zürich, CH-8091 Zürich, Schweiz

Appendix A: Brominated Flame Retardants

The laboratory fulfils the requirements for periodic emission measurement according to ČSN P CEN/TS 15675:2009

CRM s and the Dilemma of the 2nd Source. Shawn Kassner, Sr Product Manager Tim Miller, Sr Organic Chemist Phenova, A Phenomenex Company

Thin Layer and Column Chromatography

Online SPE-LC-APCI-MS/MS for the Determination of Steroidal Hormones in Drinking Water

A commitment to quality and continuous improvement

METHOD 3510C SEPARATORY FUNNEL LIQUID-LIQUID EXTRACTION

ToXIC Toy or Toxic Waste:

AutoSpec Premier. Are you? Analyzing dioxins and related compounds? Required to satisfy regulatory requirements?

Method Development of LC-MS/MS Analysis of Aminoglycoside Drugs: Challenges and Solutions

Extent and Magnitude of Sediment Contamination in Southern California by Two Chemicals of Emerging Concern

Samples RMN Analytical Report ( ) GC/FID Analysis (RM01) Nicotine Purity

Wildlife and San Francisco Bay Area (PBDE) contaminants

UHPLC/MS: An Efficient Tool for Determination of Illicit Drugs

Assay Qualification Template for Host Cell Protein ELISA

The Automated SPE Assay of Fipronil and Its Metabolites from Bee Pollen.

FOOD FOR THOUGHT Topical Insights from our Subject Matter Experts UNDERSTANDING WHAT IS NEEDED TO PRODUCE QUALITY DATA

S olid Ph ase Extraction (SP E) Method:

Fractional Distillation and Gas Chromatography

INSTRUCTOR S MANUAL FOR LABORATORY PROJECTS USING CHROMATOGRAPHY

Elimination Of RoHS Substances In Electronic Products

consultancy services

Analyzing Small Molecules by EI and GC-MS. July 2014

HRMS in Clinical Research: from Targeted Quantification to Metabolomics

Aromatic plants: from extraction to analysis

Transcription:

Template for s and secretariat Date: 006-06-30 Document: CEN/BT/TF 151/TG 4 N0013 Horizontal 4.7 BFR Author s: ALL; Replies: TG 4 1 (3) 4 5 (6) (7) on each submitted NL ge This document is poorly attuned to the other documents within HORIZONTAL with respect to the layout, editorial as well as technical content. The compounds which are to be analyzed are comparable (when the physical properties are concerned) to those within the PCB standard. DE ge This paper was kept very much in general. It was not clearly stated in the paper which PBDEs are covered by the scope and which PBDE-analytes are to be measured with high priority due to their environmental relevance and which can be measured definitely without interferences. The ISO FDIS 03 ISO/TC 147- Water quality Determination selected polybrominated diphenyl ethers in sediment and sewage sludge by extraction and GC- MS- was stated in the reference but it was not looked deeply into the matter so that there was no discussion and conclusion made on its applicability as well as on the limitations to be used as horizontal standard. In order to harmonize all documents within HORIZONTAL concerning the layout, editorial and technical content, this document needs revising. This will be done. The PBDEs which will be included in the scope are the same as in ISO 03, i.e. BDE-196, -197 and octabde For additional discussion about the ISO 03 work, see on the s made by Sabine Geiss in the ISO 03 group. AT ge At the moment two relevant papers are provided for consultation. The draft standard and a ruggedness report. The draft standard is a comprehensive review the current state PBDE analysis. Necessary analytic steps are listed and described well, especially the chromatographic part and the detection by mass spectrometry, but not in detail. As an example in the ruggedness report an analytic procedure using Soxhlet extraction or PLE, SPE Cleanup and NCI-MS detection is Yes, more details will be given in the next round. 1 MB = Member body (enter the ISO 3166 two-letter country code, e.g. CN for China; s from the ISO/CS editing unit are identified by **) : ge = general te = technical ed = editorial NOTE Columns 1,, 4, 5 are compulsory. ISO electronic balloting ing template/version 001-10 page 1 9

Template for s and secretariat Date: 006-06-30 Document: CEN/BT/TF 151/TG 4 N0013 Horizontal 4.7 BFR Author s: ALL; Replies: TG 4 1 (3) 4 5 (6) (7) on each submitted described in detail, comprising quality criteria for the described method. Other detection and clean-up methods which are mentioned in the draft standard are not described in the ruggedness report and no quality criteria from the ruggedness report are deducted for the draft standard. DK Ge For the next round consultation a detailed description all mentioned methods including quality criteria which have to be met during analysis should be given. The desk study as well as the report is named Brominated Flame Retardants, however, only Polybrominated Diphenyl Ethers (PBDEs) are mentioned in the report. This is primarily related to the desk study report. Include a description BFR as such and the analysis other BFR such as HBCD, TBBPA and PBB. We suggest that BFR is changed to PBDE, since BFR is a group compounds with very different physicochemical properties. An extension on other BFR (see left column) is not accepted, because there either was no experience or no necessity for testing in soils and/or sludges. DK Ge The method is not written as a draft method, more as a very general technical report. DK Te The ISO/DIS 03 standard for PBDEs in sediment and sewage sludge is based on a extensive work by Sabine Geiss and coworkers from Freistaat Thüringen. This is not reflected in the draft horizontal standard. Change the method to the CEN format with specified description the method. Include the experiences from the German studies made for the ISO/DIS 03. This will be done. The Desk study includes data from ISO/DIS 03. Certainly, more experiences 1 MB = Member body (enter the ISO 3166 two-letter country code, e.g. CN for China; s from the ISO/CS editing unit are identified by **) : ge = general te = technical ed = editorial NOTE Columns 1,, 4, 5 are compulsory. ISO electronic balloting ing template/version 001-10 page 9

Template for s and secretariat Date: 006-06-30 Document: CEN/BT/TF 151/TG 4 N0013 Horizontal 4.7 BFR Author s: ALL; Replies: TG 4 1 (3) 4 5 (6) (7) on each submitted from ISO/DIS 03 will be added in the next round. DK 1? Te DK 3 Te DK 3 Te The scope the method with the exact list analytes is missing. Other extraction methods should also be examined. Particularly shaking is widely used, and the method should allow other extraction techniques to be used, if they are shown to be equivalent with the prescribed technique. It is uncertain if recovery studies are based only on spiked values or on real content the sludge. Include a scope in the method. As for analytes use the list congeners from ISO/DIS 03. Include other extraction techniques, if they are shown to be equivalent with the prescribed technique. Recovery studies could include measurement on PBDEs already on the sample. Comparisons on different techniques and conditions can be made. See observation above This will be done. Shaking and sonication will be added. Our recovery studies are all blank corrected. Reference materials are existing. NL 3 te This document needs to be attuned to the HORIZONTAL standards PAH and PCB, concerning the extraction methods. In this way also other extraction solvents should be introduced next to dichloromethane which is currently prescribed (unwanted due to environmental concerns). DE Clause 3 Extraction te A traditional extraction method used for PBDE applications is based on a centrifugation methodology. (also see Table 1). There is no extraction method based on centrifugation. Centrifugation is mainly used for 1 MB = Member body (enter the ISO 3166 two-letter country code, e.g. CN for China; s from the ISO/CS editing unit are identified by **) : ge = general te = technical ed = editorial NOTE Columns 1,, 4, 5 are compulsory. ISO electronic balloting ing template/version 001-10 separation phases with different specific gravities e.g. liquid-solid separation. May be it is used in terms Sonication i.e. extraction by using ultrasonic bath. Tune the extraction methods with the methods used in the standards PAH and PCB. Shaking and sonication will be added. No other extraction solvents will be introduced. This will be clarified to mechanical shaking. page 3 9

Template for s and secretariat Date: 006-06-30 Document: CEN/BT/TF 151/TG 4 N0013 Horizontal 4.7 BFR Author s: ALL; Replies: TG 4 1 (3) 4 5 (6) (7) on each submitted NL 4 te This document needs to be attuned to the HORIZONTAL standards PAH and PCB, concerning the clean-up methods. Tune the clean-up methods with the methods used in the standards PAH and PCB This will be done for PCB clean-up procedures. Except for gel permeation chromatography, no other PAH clean-up procedures are suitable for PBDEs. NL te The sample volume 0.5g or 1.0g dry weight sample is not suitable for soil samples The sample volume soil samples should be tuned to the amounts used within the other Horizontal standards Minimum requirements will be as for Soxhlet. In ISO 03 5 g to 10 g material are used. For soils also up to 10 6 sems sufficient. For sludges 1 g to g seem to be ok due to the fineness substance. FI 4 (page 5) Line 17-18 ge Automated cleanup system based on the pre-packed Teflon columns requires large sample sets to be economical and system is also tricky to use. System is expensive to purchase compared to open column glassware In the standard we will suggest both alternatives, columns made in house and commercial pre-packed columns. FI 5 (page 7) Line 7 ge Tandem MS is possible also with Q3 MS instruments Yes, but this technique has not been used in PBDE analysis and Q3 MS instruments are more expensive compared to QIT- 1 MB = Member body (enter the ISO 3166 two-letter country code, e.g. CN for China; s from the ISO/CS editing unit are identified by **) : ge = general te = technical ed = editorial NOTE Columns 1,, 4, 5 are compulsory. ISO electronic balloting ing template/version 001-10 page 4 9

Template for s and secretariat Date: 006-06-30 Document: CEN/BT/TF 151/TG 4 N0013 Horizontal 4.7 BFR Author s: ALL; Replies: TG 4 1 (3) 4 5 (6) (7) on each submitted MS instruments. FI 5. (p 8) Last line te Analysis BDE-09 can occur together with other PBDE congeners, if the suitable technique is used The use the vacuum technique is recommended to analyse all PBDEs Yes, analysis tribdes up to decabde can be preformed on one column e.g. non-polar GC column 15 m, 0.5 mm, 0.10 µm. However, to avoid coelutions on tri- up to heptabdes, a longer GC column 30 m may be preferable. Mrs Eljarrat will check the risk for co-elution. NL 5.3 te Using the internal standard BDE-09 is not preferred, because recoveries 00%. Use another internal standard instead BDE-09. New recoveries on the BDE- 09 showed acceptable results (67% for Soxhlet 1 g sample and 5 g alumina. 1 MB = Member body (enter the ISO 3166 two-letter country code, e.g. CN for China; s from the ISO/CS editing unit are identified by **) : ge = general te = technical ed = editorial NOTE Columns 1,, 4, 5 are compulsory. ISO electronic balloting ing template/version 001-10 Like ISO/DIS 03 standard for PBDEs in sediment and sewage sludge we will include BDE-77, BDE-181 and 13 C-BDE-09 as internal standards when NCI detection is used. Two additional 13 C-labelled PBDEs (compared to ISO/DIS 03) i.e. 13 C- page 5 9

Template for s and secretariat Date: 006-06-30 Document: CEN/BT/TF 151/TG 4 N0013 Horizontal 4.7 BFR Author s: ALL; Replies: TG 4 1 (3) 4 5 (6) (7) on each submitted BDE-197 and 13 C-BDE-07 will be added to the to the method based on EI detection to cover octa- and nonabdes. Fluorinated BDF are available as internal standards. FI 6.1 nd last line te GC-MS in the NCI mode: m/z 79, 81 proves only that the compound contains Br, not that it is a PBDE compound. See 6.3 interferences Only GC-MS/MS in the EI mode is recommended EI-LRMS and especially EI- HRMS are good for identification. However, PBDE analysis in NCI mode is accepted and the most commonly used detection method in scientific peer reviewed articles. At least one internal standard should be used per level chlorination. If higher accurance is needed the use more internal standards is recommended. FR 4.7 Intro Te The scope refers to "Sludge, soil, contaminated sludge and treated biowaste". However the method has only be tested on a single material, HORIZONTAL SL 11, which is This document would not go forward to phase II. So we think that it is not possible to forward it to phase III. In case ruggedness results for waste can be achieved in time (soil is available but was 1 MB = Member body (enter the ISO 3166 two-letter country code, e.g. CN for China; s from the ISO/CS editing unit are identified by **) : ge = general te = technical ed = editorial NOTE Columns 1,, 4, 5 are compulsory. ISO electronic balloting ing template/version 001-10 page 6 9

Template for s and secretariat Date: 006-06-30 Document: CEN/BT/TF 151/TG 4 N0013 Horizontal 4.7 BFR Author s: ALL; Replies: TG 4 1 (3) 4 5 (6) (7) on each submitted a sludge. The number validation sample cannort support a horizontal scope. Add ruggedness test on soil and waste. not reported), the scope may stay as presented. Otherwise a restriction the method on soil and sludge is necessary. FR 4.7 The results for HORIZONTAL SL 11 are claimed to be reported in the "completed experimental report", which cannot be found on the website ecn.nl. The experts cannot express any opinion on the good adaptation the method without access to these reports. Make them available. Mrs Eljarrat agreed to submit the second ruggedness report to van der Sloot. Another "report on phase II ruggedness (04/05)" is addressed: where has it been published? FR 4.7 Pretreatment Te Freeze drying as a pretreatment is acceptable. A surrogate standard is supposed to be added at this step: which one? FR 4.7 Extraction, Soxhlet Te No data were found on an azeotrope between DCM and hexane. What is the purpose solvent mixture? Give information Surrogate will be deleted from the method. Give information Will be aligned to ISO 03. FR 4.7 PLE Te Sulfur remopval by copper addition in extrcation cell: Ruggedness data? Give information Ruggedness report needs to be more detailed. FR 4.7 Whole step Te Data in table 1 suggest that extraction efficiency is better for higher congener with 0,5 g sample instead 1 g. As far as a separate analytical process is recommended for higher congeners, why not recommend a separate extraction process? Extraction step is not critical, for ease practicability one extraction should be enough. FR 4.7 Clean-up Te An ISO method for purification water extracts is already published. Why not adopt it, in order for the laboratories to treat the water or the soil and sludge extracts in the same way? Give ruggedness data to explain. The is in principle correct. However, for ruggedness testing different clean-ups have been tested. Clean-ups according to ISO 1 MB = Member body (enter the ISO 3166 two-letter country code, e.g. CN for China; s from the ISO/CS editing unit are identified by **) : ge = general te = technical ed = editorial NOTE Columns 1,, 4, 5 are compulsory. ISO electronic balloting ing template/version 001-10 page 7 9

Template for s and secretariat Date: 006-06-30 Document: CEN/BT/TF 151/TG 4 N0013 Horizontal 4.7 BFR Author s: ALL; Replies: TG 4 1 (3) 4 5 (6) (7) on each submitted 03 should also be tested. FR 4.7 GC-MS Te Though it does not appear as scientifically baseless, the need different GC process for either lower or higher congeners is not explained by ruggedness data. In the water standard the process is unique. Laboratories would appreciate a homogeneous analytical frame, if possible. FR 4.7 Te Literature accredit the fact that the analytical step should be different and specific for congener 09. The "further measurements on recoveries BDE-09" are lacking. FR 4.7 Table 1,, 3 Te There are 3 congeners in table 1, 8 congeners in table, 6 congeners in table 3: which congeners are validated, which are in the scope? FR 4.7 Table 3 Te LOD and LOQ are calculated on a real sample: this is good Give ruggedness data to explain. Solved already. We would like to see ruggedness data for this congener. Ruggedness report will be updated. Give information. Will be added. Have the same requirement on every method. d. FR 4.7 6.1 Ed ISO 03 is now published. d. FR 4.7, last line Te The affirmation on the comparability starting material is very interesting. Unfortunately, no information is given. Give more information on recommended way to achieve comparability. Will be added in revised draft. 5 % water seems too high content. Show ruggedness test. FR 4.7 3, last-1 line Te The use SPME is proposed which is a nonsense in a solid matrix, even in headspace mode, regarding the volatility analytes! FR 4.7 General Ge No ruggedness data is provided. What is the connection between these two papers? To be reconsidered. d. 1 MB = Member body (enter the ISO 3166 two-letter country code, e.g. CN for China; s from the ISO/CS editing unit are identified by **) : ge = general te = technical ed = editorial NOTE Columns 1,, 4, 5 are compulsory. ISO electronic balloting ing template/version 001-10 page 8 9

Template for s and secretariat Date: 006-06-30 Document: CEN/BT/TF 151/TG 4 N0013 Horizontal 4.7 BFR Author s: ALL; Replies: TG 4 1 (3) 4 5 (6) (7) on each submitted 1 MB = Member body (enter the ISO 3166 two-letter country code, e.g. CN for China; s from the ISO/CS editing unit are identified by **) : ge = general te = technical ed = editorial NOTE Columns 1,, 4, 5 are compulsory. ISO electronic balloting ing template/version 001-10 page 9 9