Operation and Troubleshooting Guide

Similar documents
Troubleshooting Beyond the Basics. Intra-Aortic Balloon Pump

FiberOptix TM. AP Sensor Zeroing and Calibration Guide INTRA-AORTIC BALLOON PRODUCT SUPPORT HOTLINE. U.S. and Canada: IABP (4227)

SARASOTA MEMORIAL HOSPITAL NURSING PROCEDURE

R Series Quick Reference Guide

510 / 511 Cardiorespiratory Monitor Preventative Maintenance Test Procedure

Section III. Heart Mate II (2 nd Generation) III.41.1 EMT-BASIC EMT-INTERMEDIATE EMT-PARAMEDIC

Laerdal Patient Monitor Help Page 1 June 14, 2012, Rev E

ADINSTRUMENTS. making science easier. LabChart 7. Student Quick Reference Guide

Section Four: Pulmonary Artery Waveform Interpretation

Back-UPS 650 VA 120 V with AVR (BX650CI-LM)

COLLEGE OF MEDICINE. Sony Portable Video Conference Systems. Operations Manual

MAINTENANCE & TROUBLESHOOTING

Operational Overview and Controls Guide

Arrhythmia Monitoring Algorithm

ReSound Unite TV FREQUENTLY ASKED QUESTIONS. Setup & Configuration. Use & Operation. Troubleshooting

Keys Master, submaster and valet key Key number Door locks Power door locking switches

tattletale User Guide Consumer unit version P a g e

BACK PRESSURE MONITOR Operator Display with Exhaust Temperature KIT

User Guide. Temperature and Humidity Datalogger. Model 42280

INSTALLER S & OWNER S MANUAL

Cooling Rewarming QUICK REFERENCE GUIDE. First change Target Temp. Always operate in Automatic Mode. Then change Warming Rate

CONTENTS 4. HOW TO UNSET THE PANEL...7

IntelliVue MP5/MP5T TRAINING GUIDE. IntelliVue Patient Monitor. MP5/MP5T Release G.0 with Software Revision G.0x.xx. Patient Monitoring

EDA-Z5008 & Z5020. Radio Fire Alarm System. User Manual

SD Memory Card Recorder Instructions. ver

Starting a Videoconference with a portable unit:

Operational Overview and Controls Guide. Two or Three Pump IronHeart Lite with Variable Frequency Drives

DSB-100 Portable Premium Bluetooth Speaker Owner s Manual

QUICK START GUIDE 199R10546

Your Digital Adapter Easy Setup Guide

HP 5 Microprocessor Control for Mammoth Water Source Heat Pumps

Activity 4.2.3: EKG. Introduction. Equipment. Procedure

IP Talk Hosted VoIP Solutions Small Office/Home Office (SOHO) Setup Guide

Heart Rate Data Collection Software Application User Guide

Back-UPS Pro 1300/1500 Installation and Operation

Interference Analysis

The Parts of the System

5X, Mark 5X, Mark 5X Pro & Elite 4X

Dash 18X / Dash 18 Data Acquisition Recorder

Reizen Atomic Talking Analog Alarm Clock Item # Instruction Manual

BUSINESS COMMUNICATIONS DIVISION. IP4100 SIP DECT User Guide

Installation and Operation Manual Back-UPS BX800CI-AS/BX1100CI-AS

GE Healthcare. Avance Carestation. Innovating with you, shaping exceptional care

VSee Quick Guide and Tips

Using your LED Plus keypad

OARTEC SIMULATOR TRAINING MONITOR USER MANUAL Version 1.05

Maxi Pressurisation Units (Maxi, Maxi Plus & HP)

CARDIOHELP INTERFACE PRESENTER (CIP) USER GUIDE GENERAL INFORMATION ABOUT THE CIP:

User's Guide. Integrating Sound Level Datalogger. Model Introduction

Fi TV Gold Quick Start Guide

Mark and Elite series DSI. Sonar Operation manual

Reocor D External Pacemaker

Installation and Operation Back-UPS 1250, 1300, 1500

Manual for Fire Suppression & Methane Detection System

Business/Home GSM Alarm System. Installation and User Manual

WAMLocal. Wireless Asset Monitoring - Local Food Safety Software. Software Installation and User Guide BA/WAM-L-F

OPERATION MANUAL. MV-410RGB Layout Editor. Version 2.1- higher

Horizontal Sterilizer MU 012.B / I (09/07) Page 2/46. 1 Index... 2

Sigma Control PC INSIDE. 97 psi 187 F R on load

BrightLink Pro. Quick Reference. BrightLink Interaction. BrightLink Pro Features. 1 Turning on and Calibrating the Projector

TRANSPORT PROTOCOLS FOR PATIENTS ON AN INTRA-AORTIC BALLOON PUMP

The RIDZ 8x2 Audio Switcher

MAINTENANCE & TROUBLESHOOTING

Rain+Birdt. Simple To Set Timer (SST) Setup & Operation Instructions. English RAIN BIRD ( ) or visit

DIGITAL CABLE & DVR QUICK GUIDE. cable television made simple

Verizon 9100EM Router Troubleshooting

ABOUT YOUR SATELLITE RECEIVER

Scan2CRM for ACT! User Guide

HDS Gen2 RTM 4.0 software update

ATS-505. GB Version 1

AUTODIALLER / QUICKDIALLER - SA132

SYMBOL MC9060 HAND HELD TERMINAL USER MANUAL

4 Starts to flash when the system triggers an alarm/fault

Notice. Reverse engineering and disassembly are prohibited.

The phone key, which starts and ends a call. The phone number is prefaced by 1: or 2:, which indicates the line currently in use.

Multi Client (Integration)

élan Mira WiFi Wireless Communication User Guide

PTU Series Transducer Digital Display Indicator User s Manual

EXPERIMENT NUMBER 5 BASIC OSCILLOSCOPE OPERATIONS

USER MANUAL MODEL

Table of Contents. Use. Troubleshooting. Setup. Welcome. 11 How to arm/disarm system/camera(s) 19 Sync Module setup issues. 3 Installing the Blink app

User's Guide Integrating Sound Level Datalogger Model

The following information can be output as speech: status of the teacher / student connection. time markers of the timers.

CABLE ONE ALL DIGITAL

Part 2. Copyright 1998 Philips Consumer Communications L.P. All rights reserved. Printed in Mexico. Issue 1AT&T

Section Two: Arterial Pressure Monitoring

Troubleshooting the Verizon MI424WR Router

Online UPS. PowerWalker VFI 1000R/1U

INSTRUCTIONS FOR VOICE CONTROLLED TALKING ALARM CLOCK

Wireless Genie Mini MODEL C41W

MAGICAR M871A. Car alarm with two-way remote User s guide

This Document Contains:

DSTV DECODER SETUP MANUAL July 2013

Welch Allyn 1500 Patient Monitor Train the Trainer

Critical Care Therapy and Respiratory Care Section

User Guide. VT1708A VIA HD Audio Adeck For Windows 2000, Windows XP & Server Jun Revision 1.1e

Exercise, the Electrocardiogram, and Peripheral Circulation

Automatic Telephone Dialer TD-101(W)

GSM Temperature Alerter. User Manual. Manual version 1.0

Transcription:

ARROW AutoCAT 2 WAVE IABP Abbreviated Operation and Troubleshooting Guide ARROW 24-HOUR INTRA-AORTIC BALLOON PRODUCT SUPPORT: US & Canada (800)-447-IABP (800)-447-4227

Modes of Operation AutoPilot Mode Pump Selects ECG / AP source lead Continuously monitors all available ECG signals and selects an alternate lead if current ECG signal is lost or noisy Pump Sets Timing Automatically sets inflation and deflation based on current patient condition and timing method selected Automatic Trigger Selection Selects and changes trigger mode based on patient condition Selects next best trigger source if present one is lost Operator User selects ECG and AP sources and adjusts as needed User sets Timing User selects Trigger Modes of Operation

Power On Power on. LED indicates the pump is plugged in. LED indicates 80% charge on the battery.

ECG Patient Connections BEST Connection Method 5 lead ECG Cable (offers 12 lead capability) S k i n lead connection SKIN selection is preset Lead selected is displayed Alternate ECG Signal Option Standard 1/4" Phono cable Phono to Phono connection AutoPilot Mode will automaticallyselect if first ECG source available Monitor source displayed Patient connections

Arterial Pressure Patient Connections BEST OPTION via FiberOptix IAB Catheter: Light Bulb Icon Legend Black light bulb with blue square n FiberOptix IAB Catheter not connected Connect blue sensor and Cal Key PRIOR to insertion To perform manual Zero of FiberOptix IAB Catheter: Verify Auto Zero via audible tone, green light bulb and AP FOS Zero d message appears Blue light bulb n FiberOptix IAB Catheter not zero d prior to insertion Green light bulb n FiberOptix IAB Catheter zero d prior to insertion White light bulb n FiberOptix IAB Catheter cal value manually adjusted Press AP select once Press soft key under fiber optic sensor for Zero Verify green light display and AP FOS Zero d message appears XRed X through light bulb n FiberOptix Catheter unavailable

Arterial Pressure Patient Connections Alternate arterial pressure signal options: Standard transduced central lumen Select transducer cable Connect to pump Press AP select to highlight xducer Level as usual, open stopcock, press transducer zero Close stopcock; verify waveform on screen

Arterial Pressure Patient Connections Alternate arterial pressure signal options: To bring in an arterial pressure signal from a remote monitor Standard 1/4" phono cable Connect to pump Press AP select to highlight monitor Zeroing procedure performed at primary monitor NOTE: in OFF and STANDBY modes, unassisted AP values appear in white on right side of screen. in ON mode in 1:1 pumping, assisted AP values appear in white. in ON mode in 1:2, 1:4 and 1:8 pumping, assisted AP values appear in white and unassisted AP values appear in yellow subscript.

Start up Balloon Connection: Push firmly to secure balloon connection start up

Start up verify: Flashing Heart Icon White Overlay on ECG Both denote valid trigger Correct IAB Volume Display Adequate Helium Display RED BAR indicates less than 125 PSI in tank Press Pump ON

Control and Function Keys ECG Select: ECG SELECT provides selection choices for desired LEAD, input source and gain mode To change a skin lead, press ECG SELECT once. The current lead is highlighted in white. Press the soft key under the desired LEAD label to switch leads. AUTOGAIN is the preset gain mode. To manually gain the ECG lead, press the soft key to change the white highlight to manual and adjust gain as desired. To select an ECG that is brought in from another monitor source, press the ECG SELECT key twice. NOTE: Illuminated LED indicates source selected. Control and Function keys

Control and Function Keys AP Select: AP SELECT provides selection for source, scale, alarm parameter and limit as well as zero and calibration functions. To change input source, press AP SELECT twice. Note: Illuminated LED indicates source selected. AP scaling is automatic based on patient waveform. To change AP scale, press AP SELECT once. Then press the soft key under AP SCALING, and select desired scale. To enable an AP alarm, press AP SELECT once, then press the soft key under AP Alarm Off. This will turn the alarm ON. Press the soft key under AP ALARM MAP to toggle between a mean AP or augmentation alarm. Select the desired alarm limit by pressing the soft key to raise (>) or lower (<) the limit. A yellow box will appear on the display to the left of the arterial pressure waveform indicating the selected AP alarm source and the limit.

Control and Function Keys Pump Status: On Starts pumping. if pressed before STNDBY, pumping starts after one purge cycle and the pneumatic system fills with helium to 2.5mmHg. NOTE: The first time pump ON is pressed a special purge cycle is initiated. This is a purge beat followed by 9 beats, and is repeated automatically up to three times to optimize helium concentration. Standby if pump is ON, immediately stops pumping but does not vent the pneumatic system. if the pump is OFF, completes a four beat purge cycle and pressurizes the pneumatic system to 2.5mmHg. After three minutes in the standby position, the system will issue an audible alert. off immediately stops pumping, deflates the balloon and vents the pneumatic system to atmosphere.

Control and Function Keys Inflate: Adjusts the inflation point in Operator mode. Inflation occurs earlier when the left arrow is depressed and later when the right arrow is depressed. Allows the operator to optimize timing by monitoring the hemodynamic changes produced on the AP waveform. 1) Move the inflation point to the right until you can clearly see the dicrotic notch (DN) on the arterial pressure waveform (green arrow). 2) Slowly move the inflation point to the left until the dicrotic notch (40ms in front of the DN) is no longer visible. 3) Check Augmentation. Generally AUG should be greater than SYS. If not, additional assessment of the patient or IABP may be required.

Control and Function Keys DEFLATE: Adjusts the deflation point in Operator mode. Deflation occurs earlier when the left arrow is depressed and later when the right arrow is depressed. Allows the operator to optimize timing by monitoring the hemodynamic changes produced on the AP waveform. 1) Move the deflation point to the left to see the effect on the AP waveform (yellow arrow). Note the rise in the ASYS and the U shape of the ADIA. 2) Move the deflation point to the right to lower the ASYS while simultaneously keeping the ADIA lower than or equal to the DIA. 3) Return the ASSIST RATIO to 1:1.

Control and Function Keys ARRHYTHMIA TIMING: The arrhythmia timing key activates or deactivates the arrhythmia timing and/or R wave deflation function of the pump when in AutoPilot TM Mode. The AutoCAT 2 System will automatically recognize arrhythmias and implement real-time R-wave deflation when the arrhythmia timing function is ON and conditions are acceptable for R-wave deflation. This will be indicated by the LED light on. If automatic R-wave deflation is NOT desired, press the ARRHYTHMIA TIMING ON/OFF key, then the soft key under ARRHYTHMIA. TIMING until OFF is displayed. ARRHYTHMIA TIMING OFF will be displayed on the screen (when an arrhythmia is present) and an alternate algorithm will be utilized for deflation. To select R-wave deflation ON at all times, press the ARRHYTHMIA TIMING ON/OFF key, then the soft key under R-WAVE DEFL until ON is displayed. In this case, R-wave deflation (AFIB trigger) will be selected whether an arrhythmia is present or not.

Control and Function Keys Trigger Modes (Operator Mode Only): Select Operator mode and then Press the trigger key to change trigger modes. The selections will appear on the bottom of the display. Pattern Preset trigger; triggers on ECG. Recommended for regular rhythms with normal QRS complex and HR <130. Rejects pacer spikes. Peak Triggers on ECG. Recommended for regular rhythms with HR >130. Recommended for wide or abnormal QRS complexes. Recommended for irregular rhythms when R-wave deflation is not desired. Rejects pacer spikes.

Control and Function Keys Trigger Modes (Operator Mode Only): AFIB Triggers on ECG. Recommended for irregular rhythms. Provides REAL TIME (R-wave) deflation. Rejects pacer spikes. VPACE Uses V-pacer spikes to trigger. MUST BE 100% PACED. For V or AV sequential pacers. Recommended for V or AV paced rhythms with poor QRS complex. APACE Uses A-pacer spikes to trigger. MUST BE 100% PACED. For Atrial pacers only. Recommended for A paced rhythms with poor QRS complex.

Control and Function Keys Trigger Modes (Operator Mode Only): ap Uses AP waveform to trigger. Recommended when ECG is not available or too noisy. AP NOT RECOMMENDED FOR IRREGULAR RHYTHMS. INTERNAL Uses IABP internal signal for triggering. Used only when patient has no ECG and no Cardiac Output. ASYNCHRONOUS TO PATIENT CARDIAC ACTIVITY. Press INT again to confirm. not available in AutoPilot TM Mode.

Control and Function Keys Assist Ratio: ASSIST RATIO 1:1 initiates one inflation-deflation cycle for each cardiac cycle. Preset assist ratio at start-up. Maximizes counterpulsation support. ASSIST RATIO 1:2 initiates one inflation-deflation cycle for every other cardiac cycle. Generally used to assess and optimize timing in Operator mode and to wean patient from IABP support. ASSIST RATIO 1:4 initiates one inflation-deflation cycle for every fourth cardiac cycle. Used to wean patient from IABP support. ASSIST RATIO 1:8 initiates one inflation-deflation cycle for every eighth cardiac cycle. Used to wean patient from IABP support.

Control and Function Keys Balloon Volume: To adjust balloon volume Press BALLOON VOLUME key. Select INCREASE / DECREASE until desired volume is displayed. Press FULL VOLUME to return to volume based on balloon connector. Press APPLY key to initiate change. Press CANCEL key to cancel change.

Control and Function Keys Recorder: To change recorder settings Press HOME Press RECORDER SETUP Select desired waveforms or set recorder automatic print interval Recorder will print waveforms highlighted in white. Press soft key under desired waveforms to select or de-select.

Control and Function Keys Alarm Control: Reset Silences the audible alarm tone and clears the alarm message. If pumping was interrupted, the alarm message is not cleared until STNDBY or ON is pressed. If there is more than one alarm condition, one message is cleared at a time. On/Off Turns pneumatic alarms audio, recording, drain and refill on or off. Alarm message will be displayed. To select alarm time off, press key under desired setting. Time remaining for alarms off is displayed above AP Scale. Press ON/OFF again to turn on alarms. NOTE: DO NOT leave pump unattended with pneumatic alarms disabled.

Control and Function Keys Home: AP scaling Selects AP scaling mode and scales for display and recorder. Recorder setup Selects waveforms to be recorded and time interval for automatic recordings. Weaning setup Allows the user to make changes in volume and/or assist ratio and set the time interval for the weaning step. It allows the user to start the weaning step and cancel the weaning step. Show status This key will display a summary of all current operational settings as well as selected information which is tracked by the AutoCAT 2 Balloon Pump.

Control and Function Keys Home (continued): Audio setup Allows the user to set the key volume, and turn it ON/OFF and independently set alarm volume. Hemodynamics Automatically calculates: 1. AUG-SYS 2. AUG-ADIA Freezes the hemodynamic numbers for 30 seconds and displays the assisted pressures in white and the unassisted pressures in yellow. Clock setup Allows the user to set the time and date for the pump.

Control and Function Keys cursor: Moves horizontal cursor to desired assessment point. Value is displayed above cursor on the right hand side.

Alarms/Alerts NOTE: An alarm may cause the pump to stop pumping. The pump will display a message on the screen to assist in troubleshooting. Once the condition is corrected: To resume pumping Press Alarm RESET Press Pump ON If the alarm condition repeatedly appears, refer to the Operator s Manual for further information or call the Arrow IABP Support Line at 800/447-IABP. GAS ALARMS (CLASS 1 ALARMS) TRIGGER LOSS ALARMS (CLASS 2 ALARMS) AUDIBLE ALERTS (CLASS 3 ALERTS) MESSAGE ALERTS (CLASS 4 ALERTS) PUMP ACTIONS Pump to OFF IAB deflated Helium vented to atmosphere Audible alarm Freeze display Alarm/troubleshooting message displayed Prints 10 second strips (3 prior to alarm/7 after alarm) Pump to Stand-by IAB deflated Helium maintained in bellows Audible alarm Alarm/troubleshooting message displayed Automatic reset of some alarms when condition is corrected Pump remains ON Audible alarm Alarm/troubleshooting message displayed Automatic reset of some alarms when condition is corrected Pump remains ON Alarm/troubleshooting message displayed Automatic reset of some alarms when condition is corrected ALARMS/ALERTS

Alarms/Alerts GAS ALARMS (CLASS 1 ALARMS) TRIGGER LOSS ALARMS (CLASS 2 ALARMS) AUDIBLE ALERTS (CLASS 3 ALERTS) MESSAGE ALERTS (CLASS 4 ALERTS) ALARMS System Error Alarms 1-8 Unable to Refill Possible Helium Loss 2 and 3 High Pressure High Baseline Large Helium Leak Purge Failure Stand-by Alarm Disabled Pump in Stand-by for greater than 3 minutes ECG Trigger Loss (Operator mode) AP Trigger Loss (Operator mode) ECG Lead Fault (Operator mode) Trigger loss (AutoPilot TM Mode) Drain Failure Deflation Beyond 100% (Operator mode) Insufficient Time to Inflate Insufficient Time to Deflate Battery Inoperative System Running on Battery Battery time less than 20, 10 and 5 minutes Possible ECG Detected Weaning Step Complete Arterial Pressure Alarm Low Helium Tank Pressure AP FOS Signal Weak AP FOS CAL Key Missing or Corrupt AP FOS Sensor Out-of-Range Possible Late Deflation Erratic Trigger: R-Wave Deflation Erratic Triggering ECG Lead Fault (AutoPilot TM Mode) No ECG Signal Available No AP Signal Available Arrhythmia Timing not Available Bad Real Time Clock Battery Bad Ram Battery

Alarms/Alerts GAS ALARMS (CLASS 1 ALARMS) TRIGGER LOSS ALARMS (CLASS 2 ALARMS) AUDIBLE ALERTS (CLASS 3 ALERTS) MESSAGE ALERTS (CLASS 4 ALERTS) USER ACTIONS Reset alarm Review alarm message and troubleshooting information Correct condition if known Restart pump Review alarm strip If alarm persists refer to Chapter 8 of the Operator s Manual for further information. Correct condition if known. Many alarms will reset automatically when the condition is cleared. -OR- Reset alarm Review alarm message and troubleshooting information Correct condition if known Restart pump If alarm persists refer to Chapter 8 of the Operator s Manual for further information. Correct condition if known. Many alarms will reset automatically when the condition is cleared. -OR- Reset alarm Review alarm message and troubleshooting information Correct condition if known If alarm persists refer to Chapter 8 of the Operator s Manual for further information. Correct condition if known. Many alarms will reset automatically when the condition is cleared. -OR- Reset alarm Review alarm message and troubleshooting information Correct condition if known If alarm persists refer to Chapter 8 of the Operator s Manual for further information.

notes

Teleflex, Arrow, AutoCat, AutoCat 2 Wave, AutoPilot and FiberOptix are trademarks or registered trademarks of Teleflex Incorporated or its affiliates. Teleflex is a global provider of medical products designed to enable healthcare providers to protect against infections and improve patient and provider safety. The company specializes in products and services for vascular access, respiratory, general and regional anesthesia, cardiac care, urology and surgery. Teleflex also provides specialty products for device manufacturers. 2013 Teleflex Incorporated. All rights reserved. 2012-0815 Teleflex Medical PO Box 12600 Research Triangle Park, NC 27709 Toll Free: 866.246.6990 Phone: 919.544.8000 Intl: 919.433.8088 Teleflex.com