TD-MIXVENT & TD-SILENT For Outside Air 2012 International Mechanical Code

Similar documents
VENTILATION CHAPTER 4

CHAPTER 4 VENTILATION

VENTILATION CHAPTER 4

VENTILATION CHAPTER 4

CHAPTER 4 VENTILATION AIR SUPPLY

AG-TQS-IAQ-00 March 4, Application Guide. TQS with IAQ Inlet

Fan Applications & System Guide

CHAPTER 4 VENTILATION

CHAPTER 29 PLUMBING SYSTEMS

Table PARKING SPACE RATES AND PARKING SPACE OCCUPANCY

CHAPTER 29 PLUMBING SYSTEMS. [P] TABLE MINIMUM NUMBER OF REQUIRED PLUMBING FIXTURES a (See Sections and ) 1 per 40 for the

TABLE Lighting Power Densities Using the Space-by-Space Method(continued) TABLE Lighting Power Densities Using the Space-by-Space Method

Georgia Smokefree Air Act O.C.G.A A-1 through 31-12A-13

DOAS UNITS. MAKEUP AND VENTILATION AIR 100% OUTSIDE AIR. Kitchens Hotel Corridors Laboratories. Paint Booths. Capacities Tons MBH

Revised: Previously Issued As: P/BC PLUMBING FIXTURES

Chapter 3: Use and Occupancy Classification

Retail or Wholesale In conformity with the provisions of sub-section Art Gallery, Museum or Library In conformity with the

Schedule B to By-law Part A Fees Payable for Permits

R432. Health, Health Systems Improvement, Licensing. R Nursing Facility Construction. R Legal Authority. R Purpose.

Mechanical Technical Assignment One ASHRAE Standard 62.1 and Standard 90.1 Evaluation

Attached (townhouses) SC P P 4.2.3(A)1 Duplex SE SE P Accessory Dwelling Unit (ADU) to a primary residence SC SC SC SC P 4.2.3(A)2

Schedule B to By-law

Chapter PLUMBING CODE

Final - Adopted February 6, 2012 AN ORDINANCE

SCHEDULE A BY-LAW B-6 CLASSES OF PERMITS AND FEES

Commercial Energy Use Worksheet

Click a name to see the associated PD map (click when you see the hand not the arrow)

Required Light Levels

KITCHEN AND BATH REMODELING BUILDING PERMIT REQUIREMENTS

ORDINANCE NO Ordinance No Page 1 of 7. Language to be added is underlined. Language to be deleted is struck through.

University of Calgary Space Classification - September 2014 (version 8)

ARTICLE C-1 COMMERCIAL ZONE

SPACE CLASSIFICATION SCHEME

Business License / Zoning Reference Guide

PLUMBING FIXTURES GUIDELINES

Element D Services Heating, Ventilating, and Air Conditioning

Schedule A. Residential and Seasonal Dwellings. for estimating value of construction in the Township of North Kawartha

NYC Department of Education Building Condition Assessment Survey BROADWAY EDUCATION CAMPUS - MANHATTAN, 26 BROADWAY, MANHATTAN, NY, 10004

ROOM ILLUMINATION LEVEL. Corridors, Passageway Lift Stairs Escalator External Covered Ways

CITY OF LAWNDALE Commercial/District Use Table

TOWNSHIP OF CRANFORD CRANFORD, NEW JERSEY. Ordinance No

2012 CODES SIGNIFICANT CHANGES 2012 IBC

MINNESOTA STATE DEPARTMENT OF PUBLIC SAFETY

CITY OF FAIRFAX CODE ADMINISTRATION / FAX

Lee County Property Appraiser

Educational. Educational-Existing 1/28/2014. OCCUPANT LOADS [no change] Application. Application

Flexibility, Efficiency In San Antonio Arena

Meeting Facilities. Building: Alumni Hall Room #: 312 Seating Capacity: 28

General Lighting Recommendations

Vectren Commercial/Industrial New Construction Incentive Application

Space Survey Instructions

Section 6. Off-street Bicycle Space Regulations

ARTICLE VIII SECTION 8.1 O-I OFFICE INSTITUTIONAL DISTRICT

Division S-37. PD Subdistrict 37.

MINIMUM STANDARDS FOR HIGH-RISE BUILDINGS

IOWA ADMINISTRATIVE CODE PUBLIC HEALTH [641] CHAPTER 153 SMOKEFREE AIR

Presentation Outline. Common Terms / Concepts HVAC Building Blocks. Links. Plant Level Building Blocks. Air Distribution Building Blocks

EAST STROUDSBURG BOROUGH RESIDENTIAL RENTAL INSPECTION CHECK LIST

Single Family Residential Basement Finish

CHAPTER 9 FIRE PROTECTION SYSTEMS

ORDINANCE NO.:

Applications for building permits will not be reviewed until all of the required information has been submitted.

Ventilation for Acceptable Indoor Air Quality

Building Permit Application

City of Riverside. Building & Safety Division Phone: (951)

Property Maintenance Check List

Errata has been identified as follows:

MINNESOTA RULES, CHAPTER 1346 MINNESOTA MECHANICAL AND FUEL GAS CODES

1/9/2015 P:\ \Project Management\Program\Ripon Space Program - 7 January 2015.xlsx

Events and Conferences AT THE COLLEGE OF SAINT BENEDICT. Facility Guide. Experience A Place...

CHAPTER 5 Energy Efficient HVAC Design

Energy Savings Modeling and Inspection Guidelines for Commercial Building Federal Tax Deductions

Chalet Vicuna Megeve

Life Safety Code Enabling References

Carbon Monoxide Detection in Commercial Buildings (

Uniform With Exceptions

2007 ICC FINAL ACTION AGENDA

Pennsylvania Uniform Construction Code Homeowner s Guide

Once you see it, you get it! A quick overview of projects..

City of Elk River BASEMENT Office Use Only

BUILDING PERMIT SPECIFICATIONS

Utility Service Application

SUPPLEMENTAL APPLICATION Hotels & Resorts Insurance Program CITA Insurance Services A division of Brown & Brown Program Insurance Services, Inc.

Fire Alarm Systems Permit Packet. City of Greer Fire Department

EQUIVALENT RESIDENTIAL UNIT FACTORS

We hope these Frequently Asked Questions will be of use both to municipal officials and fire inspectors.

Future youth provision in Twickenham. Option two. Front of Heatham House The Garage Rear of Heatham House

Components HVAC General Standards HVAC Guidelines HVAC System Selection Life Cycle Cost Analysis

65 EASY WAYS TO CIRCULATE POST CARDS POSTAGE FREE

TURN-KEY LAB SPACE AVAILABLE

Local Law Filing. Alocallaw. of the. Be It enacted by the. County 434 of Livingston as follows:

CHAPTER 11 (CB) CENTRAL BUSINESS DISTRICT

Bleachers Pub (Capacity 160) Cafeteria NORTHERN COLLEGE - PORCUPINE CAMPUS FACILITY RENTAL FEES

HVAC Code Requirements

Commercial Districts. Purpose. Sections: The purposes of the Commercial Districts are to:

Indiana Building Rehabilitation Standard

Typical storey plan with two toilet clusters SANITARY PROVISION SANITARY PROVISION. Individual washroom. Standalone, unisex individual washroom

Page 1 of 6 COMPLIANCE CHECKLIST. > Long Term Care Facility - Nursing Unit

Measuring Houses and Counting Rooms. Using the ANSI Standards

MUNICIPALITY OF KAZABAZUA. SMOKE DETECTORS By-Law number

Transcription:

TD-MIXVENT & TD-SILENT For Outside Air 2012 International Mechanical Code One the most efficient applications for the TD-MIXVENT and TD-SILENT fans is for outside air. Sections 403.2, 403.3 of the 2012 International Mechanical Code clearly defines the requirements for mechanical ventilation and identifies the flow rates for the outdoor air required to meet this code.

Table 403.3 of 2012 International Mechanical Code Required Outdoor Ventilation Air Cells Correctional facilities without plumbing fixtures 25 5 0.12 with plumbing fixtures g 25 5 0.12 1 Dining halls (see food and beverage service) Guard stations 15 5 0.06 Day room 30 5 0.06 Booking/waiting 50 7.5 0.06 Dry cleaners, laundries Coin-operated dry cleaner 20 15 Coin-operated laundries 20 7.5 0.06 Commercial dry cleaner 30 30 Commercial laundry 10 25 Storage, pick up 30 7.5 0.12 Education Auditoriums 150 5 0.06 Corridors (see public spaces) Media center 25 10 0.12 Sports locker rooms g 0.5 Music/theater/dance 35 10 0.06 Smoking lounges b 70 60 Day care (through age 4) 25 10 0.18 Classrooms (ages 5-8) 25 10 0.12 Classrooms (age 9 plus) 35 10 0.12 Lecture classroom 65 7.5 0.06 Lecture hall (fixed seats) 150 7.5 0.06 Art classroom g 20 10 0.18 0.7 Science laboratories g 25 10 0.18 1 Wood/metal shops g 20 10 0.18 0.5 Computer lab 25 10 0.12 Multiuse assembly 100 7.5 0.06 Locker/dressing rooms g 0.25 Food and beverage service Bars, cocktail lounges 100 7.5 0.18 Cafeteria, fast food 100 7.5 0.18 Dining rooms 70 7.5 0.18 Kitchens (cooking) b 0.7 (continued)

TABLE 403.3 continued MINIMUM VENTILATION S Hospitals, nursing and convalescent homes Autopsy rooms b 0.5 Medical procedure rooms 20 15 Operating rooms 20 30 Patient rooms 10 25 Physical therapy 20 15 Recovery and ICU 20 15 Hotels, motels, resorts and dormitories Multipurpose assembly 5 0.06 Bathrooms/toilet private g 25/50 f Bedroom/living room 5 0.06 Conference/meeting 5 0.06 Dormitory sleeping areas 5 0.06 Gambling casinos 7.5 0.18 Lobbies/prefunction 7.5 0.06 Offices Conference rooms 50 5 0.06 Office spaces 5 5 0.06 Reception areas 30 5 0.06 Telephone/data entry 60 5 0.06 Main entry lobbies 10 5 0.06 Private dwellings, single and multiple Garages, common for multiple units b 0.75 Garages, separate for each dwelling b 100 cfm per car Kitchens b 25/100 f Living areas c Based upon number of bedrooms. First bedroom, 2; each additional bedroom, 1 0.35 ACH but not less than 15 cfm/person Toilet rooms and bathrooms g 20/50 f (continued)

TABLE 403.3 continued MINIMUM VENTILATION S Public spaces Corridors 0.06 Elevator car 1 Shower room (per shower head) g 50/20 f Smoking lounges b 70 60 Toilet rooms public g 50/70 e Places of religious worship 120 5 0.06 Courtrooms 70 5 0.06 Legislative chambers 50 5 0.06 Libraries 10 5 0.12 Museums (children s) 40 7.5 0.12 Museums/galleries 40 7.5 0.06 Retail stores, sales floors and showroom floors Sales (except as below) 15 7.5 0.12 Dressing rooms 0.25 Mall common areas 40 7.5 0.06 Shipping and receiving 0.12 Smoking lounges b 70 60 Storage rooms 0.12 Warehouses (see storage) Specialty shops Automotive motor-fuel dispensing stations b 1.5 Barber 25 7.5 0.06 0.5 Beauty salons b 25 20 0.12 0.6 Nail salons b, h 25 20 0.12 0.6 Embalming room b 2 Pet shops (animal areas) b 10 7.5 0.18 0.9 Supermarkets 8 7.5 0.06 Sports and amusement Disco/dance floors 100 20 0.06 Bowling alleys (seating areas) 40 10 0.12 Game arcades 20 7.5 0.18 Ice arenas without combustion engines Gym, stadium, arena (play area) 0.3 0.5 0.3 Spectator areas 150 7.5 0.06 Swimming pools (pool and deck area) 0.48 Health club/aerobics room 40 20 0.06 Health club/weight room 10 20 0.06 (continued)

TABLE 403.3 continued MINIMUM VENTILATION S Storage Repair garages, enclosed parking garages b,d 0.75 Warehouses 0.06 Theaters Auditoriums (see education) Lobbies 150 5 0.06 Stages, studios 70 10 0.06 Ticket booths 60 5 0.06 Transportation Platforms 100 7.5 0.06 Transportation waiting 100 7.5 0.06 Workrooms Bank vaults/safe deposit 5 5 0.06 Darkrooms 1 Copy, printing rooms 4 5 0.06 0.5 Meat processing c 10 15 Pharmacy (prep. area) 10 5 0.18 Photo studios 10 5 0.12 Computer (without printing) 4 5 0.06 For SI: 1cubic foot per minute = 0.0004719 m 3 /s, 1 ton = 908 kg, 1 cubic foot per minute per square foot = 0.00508 m 3 /(s * m 2 ), C = [( F) -32]/1.8, 1 square foot = 0.0929 m 2 a. Based upon net floor area. b. Mechanical exhaust required and the recirculation of air from such spaces as permitted by section 403.2.1 is prohibited (see Section 403.2.1). c. Spaces unheated or maintained below 50 F are not covered by these requirements unless the occupancy is continuous. d. Ventilation systems in enclosed parking garages shall comply with Section 404. e. Rates are per water closet or urinal. The higher rate shall be provided where the exhaust system is designed to operate intermittently. The lower rate shall be permitted only where the exhaust system is designed to operate continuously while occupied. f. Rates are per room unless otherwise indicated. The higher rate shall be provided where the exhaust system is designed to operate intermittently. The lower rate shall be permitted only where the exhaust system is designed to operate continuously while occupied. g. Mechanical exhaust is required and recirculation is prohibited except that recirculation shall be permitted where the resulting supply airstream consists of not more than 10 percent air recirculated from these spaces (see Section 403.2.1, Items 2 and 4). h. For nail salons, each nail station shall be provided with a source capture system capable of exhausting not less than 50 cfm per station.

One of the most common applications that need outdoor air are split systems that operate in the 3-10 ton performance point. The TD-MIXVENT or TD-SILENT fans provide the simplest solution. Both fans come with two speed motors that can be used in conjunction with building management systems to provide demand based outdoor air supply. TD-MIXVENT* Performance Model TD-100 TD-100x TD-125 TD-150 TD-200 TD-250 TD-315 Nom. RPM Volts Watts Speed CFM v Static Pressure (SP) Ins. WG 0 0.125 0.25 0.375 0.5 0.75 1.0 SP Max operating temp. (ºF) 2431 120 23 LS 97 81 51 - - - -.4 104 4 2 2516 120 26 HS 101 85 57 - - - -.4 104 4 1556 120 20 LS 100 77 48 - - - -.375 104 2096 120 33 HS 135 113 90 53 - - -.55 104 4 1633 120 24 LS 149 110 73 - - - -.35 104 5 4.4 2146 120 38 HS 197 168 133 86 22 - -.55 104 5 1709 120 54 LS 218 193 163 128 105 24 -.8 140 6 2289 120 65 HS 293 273 250 227 206 131 35 1.15 140 6 2322 120 139 LS 476 422 373 317 260 40-1.38 140 8 8.8 2781 120 184 HS 538 495 458 418 367 190 10 1.625 140 8 2400 115 162 LS 541 475 418 355 295 218 170 2.03 140 10 19.8 3200 115 241 HS 754 715 680 640 606 520 405 2.53 140 10 2000 115 208 LS 751 670 545 420 285 190 130 1.62 140 12.4 30.9 2500 115 335 HS 1050 990 932 850 770 600 420 2.95 140 12.4 Wgt. (lbs) Duct Dia. Ins. 4 Sones 1.1 1.7 2.1 2.8 4 5 6.8 TD-SILENT* Air Performance Model TD-100XS TD-150S TD-200S Nom. RPM Volts Watts Speed CFM v Static Pressure (SP) Ins. WG 0 0.125 0.25 0.375 0.5 0.75 1.0 SP Max operating temp. (ºF) 2000 120 21 LS 108 82 48 - - - - 0.4 104 2500 120 35 HS 143 121 91 59 23 - - 0.6 104 4 11.9 2000 120 21 LS 147 110 63 - - - - 0.4 104 5 2500 120 36 HS 203 175 138 84 33 - - 0.6 104 5 2200 120 55 LS 239 209 181 154 120 62-0.95 140 6 13.2 2700 120 65 HS 333 315 286 271 257 178 77 1.2 140 6 2000 120 115 LS 409 367 333 306 271 183 46 1.2 140 8 19.2 2200 120 122 HS 530 503 472 443 415 349 204 1.2 140 8 * TD-MIXVENT and TD-SILENT fans meet plenum rating requirements. Accessories Wgt. (lbs) Duct Dia. Ins. 4 Sones 0.6 0.5 0.5 SC Speed control CAR Backdraft Damper SIL Acoustic attenuators MFL Filtering Box

A common way to introduce outdoor air to split systems is to extend outdoor air duct to the outside wall and place a motorized damper in that outdoor air duct then interlock the damper to the furnace. When the furnace is operating the damper opens and outside air is introduced into the return air plenum based on the theory that the furnace blower in the unit will pull the air though the duct. (see Figure 1) Figure 1 Supply Air Interior Wall Indoor Unit Split System 3- - 10 Ton OSA Outside Wall In a perfect installation this would work very well when the total static of the system is kept under.50 esp. This is the max static pressure that the blower in most brands of air conditioning systems can overcome. However, systems are often installed in less than perfect applications or job site requirements change and the blowers in the units cannot overcome the pressure. This variance in pressure creates a situation where very little outdoor air is actually present in outside air duct work. Figure 2 Supply Air Return Air Plenum Indoor Unit Split System 3-10 Ton Motorized Damper Outside Wall To remove this concern from the mind of the mechanical engineer and guarantee the exact outside air to each system (see Figure 2): Interior Wall OSA 1. Determine the outdoor air required. 2. Analyze the external static of the outdoor air duct. 3. Select the appropriate fan from the performance chart. 4. Set the fan to the cfm and static required with the speed control. 5. Know the air required for the application is being delivered. Return Air Plenum TD-100x SC CAR Outside Air White Paper -2012 IMC September 19, 2013