Resistance in Circuit Breakers

Similar documents
Circuit Breakers and Switchgear. Thomas Greer Director of Engineering TLG Services

OVERCURRENT & EARTH FAULT RELAYS. To study the protection of equipment and system by relays in conjunction with switchgear.

Sentron Series Circuit Breakers

STANDARDS AND RATINGS FOR THE APPLICATION OF MOLDED CASE, INSULATED CASE, AND POWER CIRCUIT BREAKERS

Primary and Secondary Electrical Distribution Systems

Chapter 5. Components, Symbols, and Circuitry of Air-Conditioning Wiring Diagrams

Arc Fault Circuit Interrupters Frequently Asked Questions

CIRCUIT BREAKER INTERRUPTING CAPACITY AND SHORT-TIME CURRENT RATINGS

APPLICATION NOTES. Bimetal Disc Thermostat. Operating Principle

SUBJECT: How to wire a motor starter Number: AN-MC-004 Date Issued: 2/08/2005 Revision: Original

What is a multimeter?

Simulation Technology to Support the Design of Electric Distribution and Control Devices

STUDY GUIDE: ELECTRICITY AND MAGNETISM

Spending too much to maintain aging switchgear? Circuit breaker solutions from Square D Services.

3.0 CHARACTERISTICS. AR Auxiliary Relay High Speed, High Threshold C

Fundamentals of Power

Submit shop drawings for equipment provided under this section Shop drawings shall indicate:

DISTRIBUTION TRANSFORMER OVERLOAD PROTECTION TRIPPING CIRCUIT

21 st Century Facilities

Arc Flash Energy Mitigation Techniques

Thermal-Magnetic / Magnetic Only Molded Case Circuit Breakers

Circuit Breakers. NRC Series. NRC Series

Electronic Trip Circuit Breaker Basics Circuit Breaker Application Guide Class 0600

Current Transformers Ratio / Polarity / Types

Electrical Resistance Resistance (R)

GROUND DETECTION CIRCUITS FOR STATIONARY APPLICATIONS (IN PLAIN DOWN TO EARTH LANGUAGE)

Protect your home and family with Advanced Technology from Cutler-Hammer

ABB ! CAUTION. Type COQ Negative Sequence Generator Relay. (50/60 Hertz) J. Instruction Leaflet

Arc Flash Hazards. Electrical Hazards. Dan Neeser Field Application Engineer Electrical Hazards 2/18/2015. Shock.

Uncompromising safety and comfort The next generation of miniature circuit breakers MCB S 200/S 200 M

Electronic overload relay EF19 and EF45

Electronic overload relay EF65, EF96 and EF146

ABC PLAZA. For. ABC PROPERTY MANAGEMENT (Client)

Fusible Disconnect Switch

Transfer Equipment Controls

Alternate Methods to Short Circuit Breaker Coordination

Fault Characteristics in Electrical Equipment

SERVICE-LIFE EVALUATIONS OF LOW-VOLTAGE POWER CIRCUIT BREAKERS AND MOLDED-CASE CIRCUIT BREAKERS

Molded Case Circuit Breakers, Motor Protection Circuit Breakers, and Motor Circuit Protectors. Technical Data

employed to ensure the continuing reliability of critical systems.

Motor Protection Voltage Unbalance and Single-Phasing

What are the basic electrical safety issues and remedies in solar photovoltaic installations?

Typical Data Requirements Data Required for Power System Evaluation

SECTION 4 ELECTRIC MOTORS UNIT 17: TYPES OF ELECTRIC MOTORS

Table of Contents. The Basics of Electricity 2. Using a Digital Multimeter 4. Testing Voltage 8. Testing Current 10. Testing Resistance 12

Mini Circuit Breakers, Fuse Blocks, and Electronic Circuit Protection

Low Voltage Switchgear

Industrial Automation Commonly-Used Terms

Bulletin 150 SMC Flex Smart Motor Controller Specifications

MODEL 5010 DUAL CHANNEL SMOKE/FIRE DETECTION MODULE

Engineering Series Ratings: Is It Practical?

Type SA-1 Generator Differential Relay

Technicaldata General

Arc Terminator Active Arc-Resistant Switchgear

Diesel Engine Driven Generators Page 1 of 6

PREFACE. Your comments or suggestions are welcome and appreciated. They should be sent to:

Bypass transfer switch mechanisms

Choosing the Best Solution for Reducing Arc Energy

LG Air Conditioning Multi F(DX) Fault Codes Sheet. Multi Split Units

Arc Flash Avoidance and its Application to Overhead Traveling Cranes

Learning Module 13: Panelboards and Switchboards. 101 Basic Series

ETZGAR CONVEYOR COMPANY Controls Section v12.05

Fundamentals of Modern Electrical Substations Part 1: Mission of Electrical Substations and their Main Components

2a. IEM Indoor Metal Clad Medium Voltage Switchgear 15KV a. Section INDOOR METAL CLAD MEDIUM VOLTAGE SWTICHGEAR (Std.

SELECTION, APPLICATION AND MAINTENANCE

REB 1 REB 3 REB 5 REB 6 REB 8 REB 10 REB 12 REB 16

FLORIDA STATE COLLEGE AT JACKSONVILLE NON-COLLEGE CREDIT COURSE OUTLINE

The Starting System. Section 4. Starting System Overview. Starter. The starting system:

WINDING RESISTANCE TESTING

Figure 1 - Crydom 3RHP Three-phase Hybrid Solid State Contactor. Crydom Inc.

Application of Four-Pole Circuit Breakers within Data Centers

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2...

Mission Critical Data Center Systems

HAZARDS, INCLUDING SHOCK, ARC FLASH AND FIRE

MV, HV AND EHV SWITCHGEAR TESTING & COMMISSIONING

Overcurrent Protection

Type: DILM50(230V50HZ,240V60HZ) Article No.:

Basic circuit troubleshooting

ARCO Electric Products Installation and Maintenance Manual Low Voltage Automatic Power Factor Correction Capacitor Systems 2013

Schneider Electric Services: life-cycle solutions for electrical distribution equipment. Scopes of Work for Electrical Acceptance Testing

GenTech Practice Questions

SUGGESTED SPECIFICATION for Series 185 Service Entrance Rated Automatic Transfer Switches

Dimensions, Inches (mm) No. of Poles Width Height Depth 2, (210) 16 (407) 5.5 (140) (283) 16 (407) 5.5 (140)

CAT ATC POWER BREAKER & POWER CASE SWITCH AUTOMATIC TRANSFER SWITCH

AP/UP, AP/MIL Series. Magnetic Circuit Protectors

Thyristor-controlled power supplies and battery chargers

Determining the Cause of AFCI Tripping Branch/Feeder and Combination Arc Fault Circuit Interrupters Class 760

E&I MAINTENANCE ENTRY TEST ENABLING OBJECTIVES. DESCRIBE hazards and precautions taken to avoid injury in the workplace.

PS-6.2 Explain the factors that determine potential and kinetic energy and the transformation of one to the other.

Emergency Power System Services Industrial UPS, Batteries, Chargers, Inverters and Static Switches

101 BASICS SERIES LEARNING MODULE 3: FUNDAMENTALS OF ELECTRICAL DISTRIBUTION. Cutler-Hammer

Circuit Breakers. Next Generation of Protection Capabilities

Data Sheet. Electro-mechanical counters Hengstler 800 series

Secondary Unit Substations

City Of Ottawa High Voltage Substation Inspection, Maintenance Rev July 17 and Testing, ROPEC Page 1

Evaluating Water-Damaged Electrical Equipment

Programming Logic controllers

Understanding Arc Flash

Digital Energy ITI. Instrument Transformer Basic Technical Information and Application

Transcription:

Resistance in Circuit Breakers Warren C. Garber NETA Test Technician, Infraspection Level III Thermographer Industrial Electric Testing, Inc. 11321 West Distribution Avenue Jacksonville, FL 32256 Ph: 904-260-8378 www.industrialelectrictesting.com Abstract As thermographers, we see many thermal anomalies in switchgear and panelboards. However, finding the actual root cause of what appears to be high contact resistance is not as straightforward as you may think. Circuit breakers have many internal mechanical connections, all of which can radiate heat under load. Misdiagnosing thermal anomalies can result in added time, wasted money and unnecessary damage to critical equipment. Additionally, there is the frustration involved with finding that same problem during the follow-up inspection, and then having to explain to the customer or your boss why the money that was spent to tighten the connection problem didn t rectify the problem. In this presentation I will discuss the parts of circuit breakers and the ways that those parts can cause thermal anomalies commonly called connection problems. I will show, using a primary injection test set, how different connections within the breakers will produce thermal anomalies and I will then demonstrate a voltage drop technique to determine the location of the abnormal resistance. Low Voltage Circuit Breakers Discussion Low voltage (less than 600 VAC) circuit breaker types common in domestic, commercial and industrial applications include: Molded Case Circuit Breaker - rated current up to 1000A. Are generally used for low-current, low-energy power circuits. Molded case circuit breakers have self-contained overcurrent trip elements. Conventional thermal magnetic circuit breakers employ a thermal bimetallic element that has inverse time-current characteristics for overload protection and a magnetic 1

trip element for short-circuit protection. Many manufacturers are now switching over from bimetallic elements to power sensor (solid state) type trip elements. Magnetic trip only breakers have no thermal element. These breakers are principally used only for short circuit protection. Nonautomatic circuit breakers have no overload or short-circuit protection. They are primarily used for manual switching. Insulated-Case Circuit Breakers - rated current up to 5000A with interrupting capacities through 200ka. Insulated case circuit breakers are molded case circuit breakers using glass-reinforced insulating materials for increased dielectric strength. They have push to open buttons with rotary operated low torque handles with independent spring charged mechanisms. This type of mechanism provides for quickmake and quick-break protection. Wide choices of automatic trip units are available for these breakers. Heavy-Duty Power Circuit Breakers - rated current from 400 to 5000A with interrupting capacities of up to 85ka. Heavy-duty power circuit breakers employ spring operated, stored energy mechanisms for quick-make and quick-break manual or electric operation. Generally, these breakers have draw-out features whereby individual breakers can be de-energized for maintenance purposes. The manually stored energy breakers are charged and closed by use of an operating handle. The electrically operated breakers are operated by a motor or a solenoid. Overcurrent Protective Devices The low voltage protective devices are direct-acting trip, and static trip. Direct-acting Trip Devices - use a solenoid (electromagnet) whose pulling force increases with the current. The circuit breaker contacts are held closed by a latch. As the current in the solenoid increases beyond the rating of the circuit breaker, the solenoid's pull releases the latch which then allows the 2

contacts to open by spring action. Ambient temperature affects the time delay but does not affect the current rating of a magnetic breaker. Thermal magnetic circuit breakers, which are the type found in most distribution boards, incorporate both techniques with the electromagnet responding instantaneously to large surges in current (short circuits) and the bimetallic strip responding to less extreme but longer-term over-current conditions. Direct-acting trips on insulated-case and heavy-duty power circuit breakers are of the electromagnetic type. Four trip devices are available: (1) Long Time Delay (LT), (2) Short Time Delay (ST), (3) Instantaneous (INST) and (4) Ground Fault (GF). Any combination of the four functions are available to provide protection for overcurrents. A trip device is installed on each phase of the electrical circuit. The LTD, STD, INST, and GF trip devices are available in adjustable time bands to facilitate the coordination of various trip devices in series. All these units have adjustable settings. Static-Trip Devices - Static-trip devices are completely static; that is, there are no moving parts. These devices use semiconductor-based integrated circuits, capacitors, transformers, and other electronic components. Statictrip devices operate to open the circuit breaker when the current time relationship exceeds a preselected value. The energy required to trip the breaker is obtained from the circuit being protected. No external power, such as DC batteries, is required. The complete static-trip system is comprised of: 1. Primary circuit current transformers, sensors are a toroidal type mounted one per phase on the primary studs of the circuit breaker. These transformers provide a signal to the static trip device proportional to the primary current. 2. Static logic box, receives the signal from the primary current transformers. It monitors the signal, senses overloads or faults, and executes the required action in accordance with preselected settings. 3. Tripping actuator, a magnetically held latch device that receives the output signal from the static logic box, and in turn causes the circuit breaker to open. The power supply for the static logic boxes and the tripping actuator is supplied from a separate set of sensors mounted in the breaker studs. In addition to the phase overcurrent logic boxes, a ground fault sensing feature may be provided. New design advances are continually being made in the development of static-trip devices. 3

Electrical Resistance The electrical resistance of an object is a measure of its opposition to the passage of a steady electric current. An object of uniform cross section will have a resistance proportional to its length and inversely proportional to its cross-sectional area, and proportional to the resistivity of the material. Discovered by Georg Ohm in the late 1820s, electrical resistance shares some conceptual parallels with the mechanical notion of friction. The measurement unit of electrical resistance is the ohm, symbol Ω. The resistance of an object determines the amount of current through the object for a given potential difference across the object, in accordance with Ohm's law: R is the resistance of the object, measured in ohms V is the potential difference across the object, measured in volts I is the current through the object, measured in amperes The resistance of an object can be defined as the ratio of voltage to current: Resistivity, and therefore Resistance, is temperature dependent. For most materials as the temperature increases the resistance also increases. As the resistance increases due to temperature the ratio of voltage-to-current will also rise, often resulting in a drop of utilization voltage and current. Parts of the Circuit Breaker The internal parts of a circuit breaker consist of many contact points and mechanical connections all of which can generate heat under load. The picture below shows a cutaway of a single pole 20 amp circuit breaker. 1. Actuator lever - used to manually trip and reset the circuit breaker. Also indicates the status of the circuit breaker (On or Off/tripped). Most breakers are designed so they can still trip even if the lever is held or locked in the "on" position. This is sometimes referred to as "free trip" or "positive trip" operation. 4

2. Actuator mechanism - forces the contacts together or apart. 3. Contacts - Allows current when touching and breaks the current when moved apart. 4. Terminals 5. Bimetallic strip 6. Calibration screw - allows the manufacturer to precisely adjust the trip current of the device after assembly. 7. Solenoid 8. Arc divider / extinguisher As you can see, there is a lot more to a circuit breaker than just a line and a load side conductor connection. Poor contact on any one of these internal connections can cause heating within the breaker. The problem is there is enough thermal mass in the breaker body to hide the true cause of the heat. Think of the internal parts of the circuit breaker as a fused disconnect that you can only see the line and load side connections of. Many of the same parts are there, contacts and mechanical connections, with the addition of the removable trip unit on some styles of breakers. Solid State Trip Unit Primary Contacts & Arcing Contacts Trip Unit Connection Above is a molded case circuit breaker with a solid state trip unit installed. The breaker cover has been removed to show the internal parts Locating and Confirming these Internal Problems It is very important to note that electricity is very dangerous. Only qualified technicians should conduct these types of inspections. This test requires that a volt meter be used to determine the voltage drop on live electrical circuits. When conducting an electrical infrared inspection all covers and dead fronts must first be removed by a qualified person. Breaker internal problems appear thermally to be connection problems and sometimes even look as if to be load imbalance issues. These anomalies in most cases do not have very large temperature rises and can be easily overlooked. Because the heat found in these situations is indirect, the result of a much higher temperature within the breaker that can not be seen directly, normal recommendations based on temperature 5

rise should not be used. Thermography can be used to locate these problems but additional testing is needed to determine the severity and the cause of the heat. Because the breakers may be stacked in the panel or switchgear it may be difficult to get line of sight to the side of the breaker, where the breaker body material is thinnest, to see a temperature rise on the breaker body. The heat is sometimes also located in the space between two breakers. While conducting the inspection, it is important to move around because the heat may be seen reflecting off the back of the panel or bus behind the breaker. The thermal images above show the results of a breaker with internal heating. The heating cannot be seen on the breaker body but as a reflection on the back of the panel. When these types of thermal anomalies are located it is important to know the load of all phases of the breaker. If the load is balanced then a simple Milli-volt drop test can be conducted. A Milli-volt drop test can disclose several abnormal conditions inside a breaker such as eroded contacts, contaminated contacts, or loose internal connections. This test is conducted while the circuit is energized and under load. One lead of a volt meter is placed on the load side with the other on the line side of the breaker. The reading is the voltage drop through the breaker internal connections. These readings can then be compared to one another to determine if the problem is internal to the breaker. If the load is not balanced, the voltage drop readings are collected using a volt meter. Then Ohm s law can be used to calculate the resistance of each phase. After the calculated resistance is found for each phase the values can then be compared to each other to determine if the problem is internal to the breaker. Conclusion While conducting an infrared inspection of an electrical system it is important to think outside the box. A building electrical system consists of many integral parts that all must operate together to be a safe and efficient system. Thermography is an important tool in finding problems within the system; however, there must be other tools in the box. If, during an inspection, problems with the circuit breakers are found it should be noted correctly in the written report with all needed information and the customer notified. Then, a qualified electrical testing company can perform electrical tests on these circuit breakers to determine the proper corrective action. 6

References 1. Robert Friedel and Paul Israel, Edison's Electric Light: Biography of an Invention, Rutgers University Press, New Brunswick, New Jersey USA, 1986 ISBN 0-8135-1118-6 pp. 65-66 2. B. M. Weedy, Electric Power Systems Second Edition, John Wiley and Sons, London, 1972, ISBN 0471924458 pp. 428-430 3. http://bonle.en.alibaba.com/product/50348671/51680889/switch/mcb_mccb.html 4. http://www3.interscience.wiley.com/journal/113307491/abstract?cretry=1& SRETRY=0 Electrical Engineering in Japan, vol. 157 issue 4 pp. 13-23 5. United States Department of the Interior Bureau of Reclamation. Denver, Colorado, Facilities Instructions, Standards and Techniques, Volume 3-16, Maintenance of Power Circuit Breakers, Internet Version of this Manual Created December 1999, Hydroelectric Research and Technical Services Group 7