The GreenSmart remote is compatible with all of the new Travis GreenSmart products. The following units are compatible: 864 TRV GS 864 ST GS

Similar documents
Fan, Cypress / GreenField Installation Instructions (sku )

PROFLAME GT-GTM-GTMF-GTMFS

its ELECTRIC POSITION for electric heat, or set the units fan control appropriately to ELECTRIC or another appropriate setting.

Sensi TM. Wi-Fi Programmable Thermostat MANUAL OPERATION. Version: March Emerson Electric Co. All rights reserved.

RDJ10RF/SET. Wireless room temperature controller with 24-hour time switch and LCD. Programmable, for heating systems


Install Guide CT100. Caution. Caution ENGLISH. disconnect the power supply before beginning work.

TECHNICAL SERVICE DEPARTMENT Technical Service Bulletin Inch PowerVent LED Indicator Explanations & Troubleshooting Table

BODY ELECTRICAL TOYOTA ELECTRICAL WIRING DIAGRAM WORKBOOK. ASSIGNMENT Version 1.8 WORKSHEETS.

FAQs. Conserve package. Gateway... 2 Range Extender... 3 Smart Plug... 3 Thermostat... 4 Website... 7 App and Mobile Devices... 7

Wireless 7 Day Programmable Room Thermostat

SIMPLE ELECTRONIC IGNITION WIRE DIAGRAM THERMOSTAT (3) PV PILOT BURNER/IGNITOR - SENSOR Q345A (9) SPARK (4) GND (BURNER) CHASSIS GND

AVR Pellet Control Board Installation/Service Instructions

Instructions: Retain these instructions for future reference SmartChargePro35 RSCPR35-12v, 2 / 8 / 16 / 35A

SERVICE MANUAL FOR 12 VDC WALL THERMOSTAT AIR CONDITIONING SYSTEMS ROOF TOP UNITS ONLY


Programmable Room Thermostat 7 Day (5-2 Day) Models: / Power Supply: Battery / Mains

USER MANUAL WARNING! CONTENTS MODEL 1 SPECIFICATIONS READ ALL INSTRUCTIONS BEFORE PROCEEDING. Non-Programmable Single Stage Heat/Cool Thermostat

EKON BMS HVAC system. Simply Smart. Touch Screen Controller. Going green. Wireless. Wireless Thermostat with Light Switch

How To Control A Thermostat

ELECTRIC POSITION for electric heat, then confirm with Fan Test below.

Thermostatic Wiring Principles by Bob Scaringe Ph.D., P.E.

AN500T, AN1000, AN1000T, AN1500, AN1500T AN2000, AN2000T

General Information. Do programmable thermostats really save energy?

Air Conditioning Sign-Off Sheet

Heat Surge Model X5C Fire Place Insert Service Manual Applies to all units w/ circuit board

SERVICE MANUAL 12VDC WALL THERMOSTAT AIR CONDITIONING SYSTEMS ROOFTOP UNITS ONLY

How to read this guide

KD-204. Telephone Remote Switch. Operating Instructions

Manual revision August 2015 p/n

COMPUTHERM Q7 Programmable, digital room thermostat. Operating Instructions

Electrical Systems - IQAN Digital Control System. IQAN Control System Components

Install Guide 3M-50. Caution. Caution

i ChatterBox! Motorcycle Security

Install Guide CT101. Caution. Caution

MAKING MODERN LIVING POSSIBLE. living connect. Installation and User Guide. Danfoss heating

Back-UPS Pro 1300/1500 Installation and Operation

MAKING MODERN LIVING POSSIBLE. living connect. Installation and User Guide. Danfoss Heating Solutions

Mini Timer Owner's Manual. Model MT13A

STEALTH I DC MANUAL TECH SUPPORT WEB BLACK UNIT IS 24/36 ONLY

REMOTE CONTROL MANUAL

Frequently Asked Questions. Air Top Diesel Heaters. 2000STC, Evo 40 & Evo 55

Drayton Digistat +2RF/+3RF

Digi-Motor Installation Guide

T-100-R Installation Guide

Gas Fireplaces FEATURING

G670 Intermittent Pilot Ignition Controls

Gas Oven Repair Guide

INSTALLATION & SERVICE MANUAL. Display Panel

ecomax Instructions for use Wall hung room sealed fan assisted condensing boilers For the user

Wireless Thermostats 230v and Battery Operated Instruction Manual

TABLE 1: Wiring Terminals. Connect to... 1C 1H 2C 2H 1H1C 2H1C 2H2C 3H2C

SERVICE MANUAL FOR 6535 SERIES TWO TON HIGH EFFICIENCY PACKAGED HEAT PUMPS

1F /1/1 Day Programmable. 1F Thermostat Thermostat Configuration Options Heat Pump. Maximum Stages Heat/Cool 2/1

Table of Contents. Introduction. Radio Frequency Control. Initial setup Setting the time. Setting the temperature

TRANSMITTER RECEIVER THESE INSTRUCTIONS APPLY IN THE UK ONLY THESE INSTRUCTIONS ARE TO BE LEFT WITH THE USER OR AT THE APPLIANCE. Digistat Optimiser

INSTALLATION AND OPERATION MANUAL

, User s Manual

T5000 T000 LCD Digital Fan Coil Thermostat

HEAT PUMP PROGRAMMABLE THERMOSTAT

INSTALLER S & OWNER S MANUAL

Installation Instructions

User Manual. Air-conditioner Controller SB-DN-HVAC (MAC01.331)

Emergency Dialer DIAL-ALERT MODEL: AD

Si10-417_C. Pocket Manual. Service Diagnosis SPLIT & MULTI

1F Programmable Electronic Digital Heat Pump Thermostat INSTALLATION AND OPERATION INSTRUCTIONS

Automatic Phone-Out Home Monitoring Systems

AC-115 Compact Networked Single Door Controller. Installation and User Manual

Installation Guide for Hive Active Heating

AIR CONDITIONING SYSTEM 1. FFH SPECIFICATION AIR CONDITIONING SYSTEM RODIUS

IMPORTANT SAFETY INSTRUCTIONS WARNING READ AND SAVE THESE OPERATING AND SAFETY INSTRUCTIONS BEFORE USING THIS HEATER.

User Manual THR840DUK Digital Thermostat

12 Volt 30 Amp Digital Solar Charge Controller

Universal control module for motorized devices

LOPI PRICE LIST UPDATES

ELECTRONIC THERMOSTAT AND THERMOMETER With SPEED CONTROL

Table of Contents. Use. Troubleshooting. Setup. Welcome. 11 How to arm/disarm system/camera(s) 19 Sync Module setup issues. 3 Installing the Blink app

Manual. Solar Fountain Mobile Phone Charger

PUSH BUTTON START INSTALLATION MANUAL

YOUR THERMOSTAT REPLACES Assemble tools required as shown below. HAND OR POWER DRILL WITH 3/16 INCH DRILL BIT, IF NEEDED

Wireless Home Security Alarm System AM 500

User Manual of WT 493

OASIS SERVICE & TROUBLESHOOTING MANUAL (WITH DM10 OR DM12)

BC & BCH SERIES INDOOR / OUTDOOR INSTALLATION

Model Description / Applications. Intermittent Pilot Gas Ignition Control

Installation and Operation Back-UPS 1250, 1300, 1500

LGAC-KNX PROGRAMMING MANUAL. Integrations V1.0 TECHNICAL SUPPORT. Tel (+34)

T6861 Series Large LCD Digital Thermostat 110/220 VAC 2-pipe/4-pipe fan coil control

HP 5 Microprocessor Control for Mammoth Water Source Heat Pumps

PSPA711a. LUXPRO PSPA711a INSTALLATION AND OPERATING INSTRUCTIONS. Mt. Laurel, New Jersey 08054, USA

Integrated Metering Systems, Inc.

QUICK INSTALLATION GUIDE

USER S, MAINTENANCE and SERVICE INFORMATION MANUAL

Fossil fuel heating equipment

MAINTENANCE & TROUBLESHOOTING

CruzPro VAF110. AC Volts, Amps, Frequency, kw Monitor

Installation Guide. Programmable Thermostat TH6220D

Model 2300DR Installation Guide

SERVICE INSTRUCTION R410A. WALL MOUNTEDtype INVERTER SPLIT TYPE ROOM AIR CONDITIONER. Models Indoor unit Outdoor unit

IMPACT ALARM SYSTEM FOR HOSPITALS AND LABORATORIES INSTALLATION AND OPERATING INSTRUCTIONS INTRODUCTION

Transcription:

Compatibility The GreenSmart remote is compatible with all of the new Travis GreenSmart products. The following units are compatible: 564 SS GS 21 TRV GS 864 TRV GS 864 ST GS Berkshire GS Tree of Life GS Packing List Transmitter Receiver (with Cover Plate & Switch) an Control Module Velcro LP or NG Stepper Motor (with screws and label - attaches to Valve) Wire Harness (2) Power Leads (2) #8 x ½ Machine Screws (2) Wire Ties Torx T-20 Wrench Wall Mount (for placing the transmitter on a wall) (2) Drywall anchors (for wall mount) (2) #8 x 3/8 Type B Screws Page 1 of 10 9/23/09-17601559 Travis Industries, Inc.

Installation Because each appliance has different installation parameters, the installation instructions are included in the installation manual included with the appliance. A copy of the installation manual may be found online at travisproducts.com. The wiring diagram is shown below. Comfort Control Valve Spark Rod Pilot Sensor CN4 PILOT SENSOR DIGITAL IREPLACE BURNER CN0 SPARK ROD CTROL DIAGNOSTIC Pilot Ground CN3 GROUND CN2 VALVE COMMAND POWER CN1 STEPPER MOTOR BURNER CTROL RECEIVER Yellow / Green Orange Green VALVE Remote Receiver IPI / CPI Blue White TOP CTINUOUS PILOT (4) AA Batteries AN CTROL an Controller POWER INTERMITTENT PILOT 110V OUT AN OUT COM 120 VAC Power In Optional Blower(s) Thermodisk Accent Light Rheostat Accent Light (s) Page 2 of 10 10/19/09-17601559 Travis Industries, Inc.

Battery Installation Transmitter Battery Installation Install the three included AAA batteries into the remote (see igure 1). AAA Battery AAA Battery AAA Battery Receiver Battery Installation Install four AA batteries into the receiver (see igure 2). You can use the batteries from the battery backup tray on the appliance. See the installation instructions for details. These batteries control the comfort control and act as a power-backup in case the household (AC) current goes out. igure 1 AA Battery AA Battery AA Battery AA Battery igure 2 Page 3 of 10 9/23/09-17601559 Travis Industries, Inc.

Set-Up Verify the an Control Module is On The fan control module has a power switch. Make sure it is in the ( - ) position (see igure 3). This switch must remain in the position for the AC components to operate (Accent Light and Optional Blower). The module also supplies low-voltage for the fireplace controller. By leaving it in the O position, the fireplace will operate off the receiver batteries, greatly diminishing battery life. igure 3 Synchronize the Transmitter to the Remote The transmitter will need to be synchronized to the receiver before the remote will work correctly. Synchronizing is done in the following two steps below (see igure 4): a) Press the PRG (Program) button on the receiver using a paperclip or equivalent device (receiver will beep 3 times). b) Press the button on the transmitter (receiver will beep 4 times). Beep igure 4 NOTE: If power is cut off to the receiver for an extended period of time, you may need to re-synchronize the remote. Page 4 of 10 9/23/09-17601559 Travis Industries, Inc.

Direct ireplace Operation The fireplace may be directly operated from the receiver. The three positions are below (see igure 5): ireplace burner turns on (regardless of transmitter settings). O ireplace burner turns off (regardless of transmitter settings). REMOTE ireplace is controlled by the transmitter. REMOTE O PRG igure 5 NOTE: When the receiver switch is turned to or O, the mode settings (Accent Light, Blower, lame Height, Comfort Control) will remain in the same state as before the switch was moved (i.e.: the receiver remembers the last setting). If you wish to adjust the mode settings use the transmitter mode button to adjust the settings (see Mode Controls on page 8). The thermostat and burner on/off operating functions will not work on the transmitter. Page 5 of 10 9/23/09-17601559 Travis Industries, Inc.

Remote Operation Once the receiver is switched to REMOTE the transmitter operates the fireplace. Once you understand how the transmitter works, you will be able to operate your fireplace quickly and easily. Display Overview The transmitter display has four main sections (see igure 6). Thermostat Display Room Temperature Display Read-Out (Thermostat Setting, unction, etc.) Mode Display (lame Height, Blower, Light, Comfort Control) Listen for the Beep Each time you press a button on the transmitter that controls the fireplace, a beep will come from the fireplace. When you change thermostat target settings the fireplace will not beep. NOTE: When the receiver batteries start to get low, the receiver will beep intermittently. When the batteries are nearly depleted, the receiver will no longer beep. See Receiver Batteries on page 10). igure 6 Page 6 of 10 9/23/09-17601559 Travis Industries, Inc.

Manual On-Off / Smart Thermostat / Standard Thermostat Use the thermostat button to cycle through the three thermostat settings (see igure 7). Look here for the Press the thermostat button to cycle thermostat setting. through the thermostat settings. O SMART igure 7 MANUAL /O The burner will turn on and off using the remote (see igure 8). Press the On/Off button to control the burner. When off, the display will only show the current temperature. When in manual setting, the word O will appear here. O igure 8 SMART THERMOSTAT While in smart thermostat, the transmitter will control the burner to achieve the target temperature (see igure 9 below). lame height will be adjusted up or down to allow operation without turning the burner on and off (also called smart modulation). To adjust the target temperature, press the up and down buttons until a suitable temperature is achieved. When in smart thermostat setting, the word SMART will appear here. SMART This is the target temperature on the read-out. Use the up or down buttons to adjust the target temperature. igure 9 STANDARD THERMOSTAT - While in standard thermostat setting, the transmitter will turn the burner on and off to achieve the target temperature (see igure 10 below). To adjust the target temperature, press the up and down buttons until a suitable temperature is achieved. When in standard thermostat setting, the word will appear here. This is the target temperature on the read-out. Use the up or down buttons to adjust the target temperature. igure 10 NOTE: if the transmitter batteries go dead while in thermostat setting (standard or smart), the appliance will shut off after approximately 24 hours. Page 7 of 10 9/23/09-17601559 Travis Industries, Inc.

Mode Controls (lame, Blower, Light, Comfort Control) Use the mode button to cycle through the four mode controls (see igure 11 below). Press the mode button to cycle through the mode settings. O lame Height Comfort Control Look here for mode controls. Optional Blower Accent Light igure 11 lame Height lame height may be controlled using the up and down buttons when in lame Height Mode (see igure 12 below). The center display will display the 7 settings, from O to HI for full on. NOTE: lame height may not be adjusted if operating in Smart Thermostat setting. When in flame height mode, this icon will appear darkened. O This is the flame height readout. Use the up or down buttons to adjust the flame height (7 settings). High Medium Off igure 12 Blower Speed If your heater has an optional blower, it may be controlled using the up and down buttons when in Blower Speed Mode (see igure 13). The center display will display the 7 settings, from O to HI for full on. When in blower mode, this icon will appear darkened. O This is the blower speed readout. Use the up or down buttons to adjust the blower speed (7 settings). High Medium Off igure 13 Page 8 of 10 9/23/09-17601559 Travis Industries, Inc.

Mode Controls (continued) Accent Light (Aux) The Accent Light (night light) inside the heater may be turned on and off using the up and down buttons when in Accent Light (Aux) Mode (see igure 14). The center display will display either or O. When in accent light mode, this icon will appear darkened. O This is the accent light readout. Use the up button to turn on, down button to turn off (2 settings). igure 14 HINT: The rheostat on the heater must be turned on for remote operation to work correctly. You may wish to adjust the rheostat to a desirable light output prior to operating. HINT: If you wish to leave the accent light on while turning the burner off, adjust the lame Height to O (see the previous page). On Off Comfort Control (rear burner) The comfort control (rear burner) may be turned on and off using the up and down buttons when in Comfort Control Mode (see igure 15). The center display will display either or O. When in comfort control mode, this icon will appear darkened. O This is the comfort control read-out. Use the up button to turn on, down button to turn off (2 settings). igure 15 On Off Page 9 of 10 9/23/09-17601559 Travis Industries, Inc.

Low Battery Indicator Transmitter Batteries The transmitter has a battery-level indicator. When it indicates low battery voltage (see igure 16 below), install four new AAA alkaline batteries into the transmitter (see Transmitter Battery Installation on page 3). Low Battery Indicator igure 16 Receiver Batteries The receiver will beep periodically when the receiver batteries go low. Install four new AA alkaline batteries into the receiver when this occurs (see Receiver Battery Installation on page 3). In applications where the appliance is required to provide heat, we recommend replacing the batteries before each heating season. Child Proof eature The child proof feature disables the control buttons, preventing un-wanted use of the remote. Press both the MODE and UP buttons simultaneously to turn this feature on and off (see igure 17 below). HINT: This feature is especially useful while using the thermostat setting. Child Proof Indicator igure 17 Power Outages The remote will work if household current (AC power) is disconnected. The batteries inside the receiver will continue to power the heater but the accent light and blower will not operate. Page 10 of 10 9/23/09-17601559 Travis Industries, Inc.