For In Vitro Diagnostic Use

Similar documents
PRINCIPLE. REF (200 tests/cartridge) REF (400 tests/cartridge) ANNUAL REVIEW Reviewed by: Date. Date INTENDED USE

For In Vitro Diagnostic Use

PRINCIPLE REF ANNUAL REVIEW Reviewed by: Date. Date INTENDED USE

Biochemistry Validation Form

Laboratory Procedure Manual

Application Sheet for Rivaroxaban (Xarelto ) Standard Range with. BIOPHEN Heparin LRT (#221011/221013) RUO

How To Test For Creatinine

USING CLSI GUIDELINES TO PERFORM METHOD EVALUATION STUDIES IN YOUR LABORATORY

Content Sheet 7-1: Overview of Quality Control for Quantitative Tests

Intact PTH. system. Intact PTH /R5. Key to symbols used 8K25

Rat Creatine Kinase MB isoenzyme,ck-mb ELISA Kit

Validation and Calibration. Definitions and Terminology

Title: Glucose Testing: StatStrip Glucose Meter Page 1 of 6

Inc. Wuhan. Quantity Pre-coated, ready to use 96-well strip plate 1 Plate sealer for 96 wells 4 Standard (liquid) 2

IgM ELISA. For the quantitative determination of IgM in human serum and plasma. For Research Use Only. Not For Use In Diagnostic Procedures.

HEMATOCRIT/HCT AND CALCULATED HEMOGLOBIN/HB

Vitamin B12. ADVIA Centaur System

510(K) SUMMARY FEB Submitter: Name of the device: * Common Name: Clinical Chemistry Analyzer (with optional ISE Module) Attachment #2

510(k) SUBSTANTIAL EQUIVALENCE DETERMINATION DECISION SUMMARY

Canine creatine kinase MB isoenzyme (CK-MB)ELISA Kit

UNIT: Total and Direct Bilirubin

Mouse Creatine Kinase MB isoenzyme (CKMB) ELISA

How to Verify Performance Specifications

ACID-BASE TITRATIONS: DETERMINATION OF CARBONATE BY TITRATION WITH HYDROCHLORIC ACID BACKGROUND

Human Free Testosterone(F-TESTO) ELISA Kit

Quality Control of the Future: Risk Management and Individual Quality Control Plans (IQCPs)

Malondialdehyde (MDA) ELISA

PROCEDURE COVERSHEET. Document Section: CHEMISTRY Author: JOANNE WONG Date Authored: JAN In Use Date: 2/1/2011 Discontinued Date:

Development and Validation of In Vitro Diagnostic Tests. YC Lee, Ph.D. CEO

Method Validation/Verification. CAP/CLIA regulated methods at Texas Department of State Health Services Laboratory

Cold Agglutination Titer detecting Cold Reacting Antibodies

Mouse IgM ELISA. Cat. No. KT-407 K-ASSAY. For the quantitative determination of IgM in mouse biological samples. For Research Use Only. 1 Rev.

TOTAL PROTEIN FIBRINOGEN

Hepatitis and Retrovirus. LIAISON XL Accurate detection of HIV infection. HIV Ab/Ag FOR OUTSIDE THE US AND CANADA ONLY

Chapter 14 Urinalysis, Body Fluids and Other Specimens. Objectives:

Lab 2. Spectrophotometric Measurement of Glucose

Understanding Analytical Chemistry (Weighing, Mixing, Measuring and Evaluating)

Measurement by Ion Selective Electrodes

Laboratory Procedure Manual

URINE DIPSTICK Multistix 10SG

Mouse Keyhole Limpet Hemocyanin antibody(igm) ELISA Kit

Mouse Insulin ELISA. For the quantitative determination of insulin in mouse serum and plasma

This package insert contains information to run the Creatine Kinase assay on the ARCHITECT c Systems and the AEROSET System.

Tests that have had changes to the method/ CPT code, units of measurement, scope of analysis, reference comments, or specimen requirements.

Measuring ph in Water or CaCl2 Using a ph Meter. Compiled by Darren Murray, June 30, 2011 TABLE OF CONTENTS OVERVIEW 3

RealLine HCV PCR Qualitative - Uni-Format

Cadmium Reduction Method Method to 30.0 mg/l NO 3 N (HR) Powder Pillows or AccuVac Ampuls

A Potentiometric Analysis of Fluoride Ion in Toothpaste

Unaccredited Point-of-Care Laboratory Testing Guideline for Physicians

Med TechNet Online Services East Amherst, NY November 1997

TBA-FX8 Automated Clinical Chemistry Analyzer with Flexibility to Respond to Demands of Large-Scale Clinical Laboratories

Collect and label sample according to standard protocols. Gently invert tube 8-10 times immediately after draw. DO NOT SHAKE. Do not centrifuge.

CONFIRMATION OF ZOLPIDEM BY LIQUID CHROMATOGRAPHY MASS SPECTROMETRY

Immunoglobulin E (IgE) concentrations in Human. Immunoglobulin E (IgE) Human ELISA Kit

Reference Range: mmol/l (arterial) mmol/l (venous) CPT Code: 83605

Direct ISE Method Method to 1000 mg/l Na + Sodium ISE

Epinephrine/Norepinephrine ELISA Kit

Chlorine, Total. DPD Method 1 Method to 5.00 mg/l Cl 2 Test 'N Tube Vials. Test preparation. Instrument-specific information

JOINT COMMISSION INTERNATIONAL ACCREDITATION STANDARDS FOR. 2nd Edition

Cancer Antigen CA125 Human ELISA Kit

This package insert contains information to run the Glucose assay on the ARCHITECT c Systems and the AEROSET System.

Ion Selective Electrodes

SureStep Pro Linearity Test Kit and Analytical Measurement Range Verification (AMR)

Bovine Vitamin B12 (VB12) ELISA Kit

Basic Lessons in Laboratory Quality Control

Appendix D lists the Field Services Standard Operating Procedures. Appendix E lists the Biological Monitoring Standard Operating Procedures.

Quaternary Ammonium Compounds DOC

Carolina s Solution Preparation Manual

Mouse glycated hemoglobin A1c(GHbA1c) ELISA Kit

Experiment 8 - Double Displacement Reactions

Validation of measurement procedures

Develop a Quantitative Analytical Method for low (» 1 ppm) levels of Sulfate

Chapter 16: Tests for ions and gases

STEP-BY-STEP INSTRUCTIONS FOR INVESTIGATIONAL USE. Rapid HCV Antibody Test FOR ORAQUICK RAPID HCV ANTIBODY TEST

Chapter. Guaiac Screening CHAPTER 4: GUAIAC TESTING SCREENING FOR OCCULT BLOOD. Page 1 of 5 Guaiac doc 6/24/2005

Tutorial 4 SOLUTION STOICHIOMETRY. Solution stoichiometry calculations involve chemical reactions taking place in solution.

USEPA 1 FerroVer Method 2 Method to 3.00 mg/l Fe Powder Pillows or AccuVac Ampuls

Rat creatine kinase MM isoenzyme (CK-MM) ELISA Kit

Standardization, Calibration and Quality Control

METHODS OF VITAMIN ANALYSIS

Stoichiometry Limiting Reagent Laboratory. Chemistry 118 Laboratory University of Massachusetts, Boston

CHEMICAL DETERMINATION OF EVERYDAY HOUSEHOLD CHEMICALS

ph Alkalinity of Water

4.2 Bias, Standards and Standardization

Toxoplasma gondii IgM ELISA Kit Protocol

SAMPLE PROCEDURE , 09/11

Content Sheet 5-1: Overview of Sample Management

This package insert contains information to run the Lactic Acid assay on the ARCHITECT c Systems and the AEROSET System.

Phosphorus, Reactive (Orthophosphate)

Solubility Product Constant

Carcinoembryonic Antigen (CEA)

6 Characterization of Casein and Bovine Serum Albumin

Urinalysis Compliance Tools. POCC Webinar January 19, 2011 Dr. Susan Selgren

ab83369 Alkaline Phosphatase Assay kit (Colorimetric)

In vitro diagnostic reagent, calibrator and control material stability

CDC-Lipid Standardization Program. Laboratory Data Collection System (LDCS) Instruction Manual

3.4 TEST FOR BACTERIAL ENDOTOXINS. Final text for revision of The International Pharmacopoeia

Solubility Product Constants

LIAISON XL HCV Ab Accurate diagnosis of the early stage of HCV infection

FerroVer Method 1 Method to 3.0, 1.0 to 30.0 and 10.0 to mg/l Fe Powder Pillows

Transcription:

SYNCHRON System(s) Chemistry Information Sheet Chloride REF & 467915 467935 REF & A28945 A28937 For In Vitro Diagnostic Use ANNUAL REVIEW Reviewed by: Reviewed by: Date Refer to coversheet in front of method PRINCIPLE INTENDED USE ISE Electrolyte Buffer reagent and ISE Electrolyte Reference reagent, when used in conjunction with SYNCHRON LX System(s), UniCel DxC 600/800 System(s) and SYNCHRON Systems AQUA CAL 1 and 2, are intended for the quantitative determination of chloride concentration in human serum, plasma, urine or cerebrospinal fluid (CSF). INICAL SIGNIFICANCE Chloride measurements are used in the diagnosis and treatment of electrolyte and metabolic disorders such as cystic fibrosis and diabetic acidosis. METHODOLOGY The SYNCHRON System(s) determines chloride ion concentration by indirect potentiometry utilizing a solid state chloride electrode in conjunction with a glass sodium reference electrode. To measure chloride ion concentrations, a precise volume of sample (40 microliters) is mixed with a buffered solution. The ratio used is one part sample to 33 parts buffer. The high molar strength buffer is used to establish a constant activity of chloride ions, calibrating the electrode to concentration values. CHEMICAL REACTION SCHEME The solid state chloride electrode consists of a sparingly soluble silver chloride compound. 1 When sample buffer mixture contacts the electrode, changes in electrode potential occur as the chloride ions in the sample shift the following chemical equilibrium: A stable electrode potential, referenced to the sodium reference electrode, is reached when a new chemical equilibrium is established, which is in part determined by the solubility product (Ksp) of the silver chloride compound. The silver chloride based electrode responds to silver ion concentration change according to the Nernst equation: 11/03/2011 1 / 13

The AgCl electrode indirectly responds to chloride ions, and the electrode potential is inversely proportional to the chloride ion concentration in the sample. For more accurate measurement, the reference reagent containing chloride ions is introduced to the flow cell after the sample cycle, and the same chemical equilibrium shift takes place. The differential potential (voltage) between sample and reference reagent cycles is used for chloride calculation. SPECIMEN TYPE OF SPECIMEN Biological fluid samples should be collected in the same manner routinely used for any laboratory test. 2 Freshly drawn serum, plasma, CSF or properly collected urine (random/timed) are the preferred specimens. Acceptable anticoagulants are listed in the PROCEDURAL NOTES section of this chemistry information sheet. Whole blood is not recommended for use as a sample. SPECIMEN STORAGE AND STABILITY 1. Tubes of blood are to be kept closed at all times and in a vertical position. It is recommended that the serum or plasma be physically separated from contact with cells within two hours from the time of collection. 3 2. Separated serum or plasma should not remain at room temperature longer than 8 hours. If assays are not completed within 8 hours, serum or plasma should be stored at +2 C to +8 C. If assays are not completed within 48 hours, or the separated sample is to be stored beyond 48 hours, samples should be frozen at -15 C to -20 C. Frozen samples should be thawed only once. Analyte deterioration may occur in samples that are repeatedly frozen and thawed. 3 3. It is recommended that urine assays be performed within 2 hours of collection. For timed specimens, the collection container should be kept in the refrigerator or on ice during the timed period. No preservative is required. 4 4. CSF specimens should be centrifuged and analyzed without delay. Specimens may be refrigerated or frozen for 7 to 10 days for repeat determinations. 5 11/03/2011 2 / 13

ADDITIONAL SPECIMEN STORAGE AND STABILITY CONDITIONS AS DESIGNATED BY THIS LABORATORY: Refer to Sample Integrity in Chemistry write up in Policies and Procedures manual SAMPLE VOLUME A filled 0.5 ml sample cup is the optimum volume. For optimum primary sample tube volumes in primary tube samples and minimum volumes, refer to the Primary Tube Sample Template for your system. CRITERIA FOR UNACCEPTABLE SPECIMENS Refer to the PROCEDURAL NOTES section of this chemistry information sheet for information on unacceptable specimens. CRITERIA FOR SAMPLE REJECTION AS DESIGNATED BY THIS LABORATORY: Refer to Sample Integrity in Chemistry write up in Policies and Procedures manual PATIENT PREPARATION SPECIAL INSTRUCTIONS FOR PATIENT PREPARATION AS DESIGNATED BY THIS LABORATORY: Refer to Sample Integrity in Chemistry write up in Policies and Procedures manual SPECIMEN HANDLING SPECIAL INSTRUCTIONS FOR SPECIMEN HANDLING AS DESIGNATED BY THIS LABORATORY: Refer to Sample Integrity in Chemistry write up in Policies and Procedures manual REAGENTS CONTENTS Each kit contains the following items: ISE ELECTROLYTE BUFFER REAGENT: Two Electrolyte Buffer Reagent Bottles (2 x 2 L) ISE ELECTROLYTE REFERENCE REAGENT: Two Electrolyte Reference Reagent Bottles (2 x 2 L) VOLUMES PER TEST Sample Volume 40 µl Reagent Volume ISE Electrolyte Buffer ISE Electrolyte Reference 1.27 ml 3.23 ml 11/03/2011 3 / 13

(not part of sample dilution) REACTIVE INGREDIENTS REAGENT CONSTITUENTS ISE ELECTROLYTE BUFFER REAGENT: Tris 230 mmol/l ISE ELECTROLYTE REFERENCE REAGENT: Sodium 7 mmol/l Potassium 0.2 mmol/l Chloride 5 mmol/l Carbon Dioxide 1.5 mmol/l Calcium 0.1 mmol/l Also non-reactive chemicals necessary for optimal system performance. Avoid skin contact with reagent. Use water to wash reagent from skin. MATERIALS NEEDED BUT NOT SUPPLIED WITH REAGENT KIT SYNCHRON Systems AQUA CAL 1 and 2 At least two levels of control material REAGENT PREPARATION No preparation is required. ACCEPTABLE REAGENT PERFORMANCE The acceptability of a reagent is determined by successful calibration and by ensuring that quality control results are within your facility's acceptance criteria. REAGENT STORAGE AND STABILITY 1. ISE Electrolyte Reference reagent stored unopened at room temperature is stable until the expiration date printed on the bottle label. Once opened, the reagent is stable at room temperature for 30 days, unless the expiration date is exceeded. 2. ISE Electrolyte Buffer reagent stored unopened at room temperature is stable until the expiration date printed on the bottle label. Once opened, the reagent is stable at room temperature for 30 days, unless the expiration date is exceeded. 3. For any electrolyte reagents frozen in transit, completely warm to room temperature and mix thoroughly by gently inverting bottle at least 20 times to redissolve salts into solution. ISE ELECTROLYTE BUFFER REAGENT AND ISE ELECTROLYTE REFERENCE REAGENT STORAGE LOCATION: Chemistry department, room L568. Stored on open shelves kept at room temperature (monitored daily.) 11/03/2011 4 / 13

CALIBRATION CALIBRATOR REQUIRED SYNCHRON Systems AQUA CAL 1 and 2 CALIBRATOR PREPARATION No preparation is required. CALIBRATOR STORAGE AND STABILITY SYNCHRON Systems AQUA CAL 1 and 2 are stable until the expiration date printed on the calibrator bottles if stored capped in the original containers at +2 C to +8 C. Once opened, calibrators are stable for 30 days stored at room temperature unless the expiration date is exceeded. CALIBRATOR STORAGE LOCATION: Opened Aqua Cal bottles kept at room temperature (monitored daily) in Chemistry department room L568. Unopened Aqua Cal bottles kept in Chemistry refrigerator #6 in Chemistry department room L568. CALIBRATION INFORMATION 1. The system must have valid calibration factors in memory before controls or patient samples can be run. 2. Under typical operating conditions the assay must be calibrated every 24 hours or with each new bottle of reagent and also with certain parts replacement or maintenance procedures, as defined in the SYNCHRON LX Maintenance Manual and Instrument Log, or the UniCel DxC 600/800 System Instructions for Use (IFU) manual. 3. For detailed calibration instructions, refer to the SYNCHRON LX Operations Manual, or the UniCel DxC 600/800 System Instructions For Use (IFU) manual. 4. The system will automatically perform checks on the calibration and produce data at the end of calibration. In the event of a failed calibration, the data will be printed with error codes and the system will alert the operator of the failure. For information on error codes, refer to the SYNCHRON LX Diagnostics and Troubleshooting Manual, or the UniCel DxC 600/800 System Instructions For Use (IFU) manual. TRACEABILITY For Traceability information refer to the Calibrator instructions for use. QUALITY CONTROL At least two levels of control material should be analyzed daily. In addition, these controls should be run with each new calibration, with each new bottle of reagent, and after specific maintenance or troubleshooting procedures as detailed in the appropriate system manual. More frequent use of controls or the use of additional controls is left to the discretion of the user based on good laboratory practices or laboratory accreditation requirements and applicable laws. The following controls should be prepared and used in accordance with the package inserts. Discrepant quality control results should be evaluated by your facility. 11/03/2011 5 / 13

NOTICE Do not use controls containing diethylamine HCl. TABLE 1 QUALITY CONTROL MATERIAL CONTROL NAME SAMPLE TYPE STORAGE Monitrol levels 1 and 2 vials in use kept refrigerated after thawing. Unopened Monitrol kept frozen until just before use. Refer to DXC 800 Control Analysis in DXC 800 procedure manual for other control material used and storage. Control preparations and acceptance of QC results are in Policies and Procedures manual TESTING PROCEDURE(S) 1. If necessary, load the reagent onto the system. 2. After reagent load is completed, calibration is required. 3. Program samples and controls for analysis. 4. After loading samples and controls onto the system, follow the protocols for system operations. For detailed testing procedures, refer to the SYNCHRON LX Operations Manual, or the UniCel DxC 600/800 System Instructions For Use (IFU) manual. CALCULATIONS The SYNCHRON System(s) performs all calculations internally to produce the final reported result. The system will calculate the final result for sample dilutions made by the operator when the dilution factor is entered into the system during sample programming. REPORTING RESULTS Equivalency between the SYNCHRON LX and UniCel DxC 600/800 Systems has been established. Chemistry results between these systems are in agreement and data from representative systems may be shown. REFERENCE INTERVALS Each laboratory should establish its own reference intervals based upon its patient population. The following reference intervals were taken from literature and a study performed on SYNCHRON Systems. 6 TABLE 2 REFERENCE INTERVALS INTERVALS SAMPLE TYPE CONVENTIONAL UNITS S.I. UNITS Literature Serum or Plasma 98 107 mmol/l 98 107 mmol/l Urine (timed) 110 250 mmol/24 hrs 110 250 mmol/24 hrs CSF 118 132 mmol/l 118 132 mmol/l SYNCHRON Serum or Plasma 101 111 mmol/l 101 111 mmol/l INTERVALS SAMPLE TYPE CONVENTIONAL UNITS S.I. UNITS Laboratory Serum or Plasma, Pedi 97 108 mmol/l n/a and adults 11/03/2011 6 / 13

INTERVALS SAMPLE TYPE CONVENTIONAL UNITS S.I. UNITS Urine (timed) 50-250 mmol/day n/a Refer to References (5, 7, 8) for guidelines on establishing laboratory-specific reference intervals. 1. Normal range for >18y adults was determined by testing 271 male and female healthy blood donors at UCSF. 2. Pediatric range same as adults as referenced in Soldin, Pediatric Reference Intervals 6 th ed. 2007, Methods 1,2,3. ADDITIONAL REPORTING INFORMATION AS DESIGNATED BY THIS LABORATORY: Refer to DXC 800 Linearity and Reportable Range chart in Technical Notes section of DXC 800 Procedure manual. PROCEDURAL NOTES ANTICOAGULANT TEST RESULTS 1. If plasma is the sample of choice, the following anticoagulants were found to be compatible with this method based on a study of 20 healthy volunteers: TABLE 3 COMPATIBLE ANTICOAGULANTS ANTICOAGULANT LEVEL TESTED FOR IN VITRO INTERFERENCE Ammonium Heparin 14 Units/mL NSI a AVERAGE PLASMA-SERUM BIAS (mmol/l) Lithium Heparin 14 Units/mL NSI Sodium Heparin 14 Units/mL NSI Potassium Oxalate/Sodium Fluoride 2.0 / 2.5 mg/ml NSI 2. The following anticoagulants were found to be incompatible with this method: TABLE 4 INCOMPATIBLE ANTICOAGULANTS ANTICOAGULANT LEVEL TESTED FOR IN VITRO INTERFERENCE AVERAGE PLASMA-SERUM BIAS (mmol/l) b EDTA 1.5 mg/ml -5.3 LIMITATIONS If urine or CSF samples are cloudy or turbid or if CSF samples are visibly contaminated with blood, it is recommended that they be centrifuged before analysis. INTERFERENCES 1. The following substances were tested for interference with this methodology: TABLE 5 INTERFERENCES SUBSTANCE SOURCE LEVEL TESTED INTERFERENCES c Bilirubin (unconjugated) Bovine 30 mg/dl NSI d Hemoglobin RBC hemolysate 500 mg/dl NSI Lipemia Intralipid e 500 mg/dl NSI 11/03/2011 7 / 13

SUBSTANCE SOURCE LEVEL TESTED INTERFERENCES c Acetylsalicylic Acid NA f 60 mg/dl NSI Ammonium Nitrate NA 40 mmol/l NSI Cefotaxime Cefotaxime sodium salt 500 µg/ml NSI Cefoxitin Cefoxitin sodium salt 200 µg/ml NSI Sulfobromophthalein Sulfobromophthalein sodium 2.0 mg/dl NSI salt N-Acetyl Cysteine NA 2 mmol/l +3 mmol/l Bromide Lithium bromide 1 mmol/l +8 mmol/l Iodide Sodium Iodide 4 mmol/l +2 mmol/l L-Dopa NA 40 µg/ml -3 mmol/l 2. Lipemic samples with visual turbidity >3+, or with a Lipemia Serum Index >10, should be ultracentrifuged and the analysis performed on the infranate. 3. Refer to References (9,10,11) for other interferences caused by drugs, disease and preanalytical variables. PERFORMANCE CHARACTERISTICS Analytic Range The SYNCHRON analytical ranges: System(s) method for the determination of this analyte provides the following TABLE 6 ANALYTICAL RANGE SAMPLE TYPE CONVENTIONAL UNITS S.I. UNITS Serum/Plasma/CSF 50 200 mmol/l 50 200 mmol/l Urine 15 300 mmol/l 15 300 mmol/l Samples with concentrations exceeding the high end of the analytical range should be diluted with deionized water and reanalyzed. REPORTABLE RANGE (as determined on site): TABLE 7 REPORTABLE RANGE SAMPLE TYPE CONVENTIONAL UNITS S.I. UNITS Serum/Plasma/CSF 50 200 mmol/l n/a Urine 15 300 mmol/l n/a SENSITIVITY Sensitivity is defined as the lowest measurable concentration which can be distinguished from zero to 95% confidence. Sensitivity for the chloride determination is 50 mmol/l for serum, plasma or CSF and 15 mmol/l for urine. 11/03/2011 8 / 13

EQUIVALENCY Equivalency was assessed by Deming regression analysis of patient samples to accepted clinical methods. Serum or plasma (in the range of 83.36 to 179.93 mmol/l): Y (SYNCHRON LX Systems) = 1.018X - 1.92 N = 99 MEAN (SYNCHRON LX Systems) = 114.3 MEAN (SYNCHRON CX Systems) = 114.2 CORRELATION COEFFICIENT (r) = 0.992 Urine (in the range of 15.6 to 290.4 mmol/l): Y (SYNCHRON LX Systems) = 0.986X + 0.15 N = 125 MEAN (SYNCHRON LX Systems) = 129.3 MEAN (SYNCHRON CX Systems) = 130.9 CORRELATION COEFFICIENT (r) = 0.997 CSF (in the range of 48.77 to 198.93 mmol/l): Y (SYNCHRON LX Systems) = 1.038X - 5.27 N = 71 MEAN (SYNCHRON LX Systems) = 127.23 MEAN (SYNCHRON CX Systems) = 126.76 CORRELATION COEFFICIENT (r) = 0.999 Serum or Plasma (in the range of 53 to 200 mmol/l): Y (UniCel DxC Systems) = 1.005X - 0.86 N = 194 MEAN (UniCel DxC Systems) = 108.0 MEAN (SYNCHRON LX Systems) = 108.3 Correlation Coefficient (r) = 0.997 Urine (in the range of 14.9 to 300 mmol/l): Y (UniCel DxC Systems) = 0.982X +0.52 N = 72 MEAN (UniCel DxC Systems) = 141.8 MEAN (SYNCHRON LX Systems) = 143.8 Correlation Coefficient (r) = 1.000 CSF (in the range of 52.3 to 194.4 mmol/l): 11/03/2011 9 / 13

CSF (in the range of 52.3 to 194.4 mmol/l): Y (UniCel DxC Systems) = 0.980X + 0.58 N = 108 MEAN (UniCel DxC Systems) = 130.8 MEAN (SYNCHRON LX Systems) = 133.0 Correlation Coefficient (r) = 0.993 Refer to References (12) for guidelines on performing equivalency testing. PRECISION A properly operating SYNCHRON System(s) should exhibit imprecision values less than or equal to the maximum performance limits in the table below. Maximum performance limits were derived by an examination of the imprecision of various methods, proficiency test summaries, and literature sources. TABLE 8 MAXIMUM PERFORMANCE LIMITS TYPE OF SAMPLE TYPE 1 SD CHANGEOVER VALUE g % CV PRECISION mmol/l mmol/l Within-run Serum/Plasma/CSF 2.0 100.0 2.0 Urine 3.0 100.0 3.0 Total Serum/Plasma/CSF 3.0 100.0 3.0 Urine 4.5 100.0 4.5 Comparative performance data for the SYNCHRON LX System evaluated using the NCS Approved Guideline EP5-A appears in the table below. 13 Each laboratory should characterize their own instrument performance for comparison purposes. TABLE 9 NCS EP5-A PRECISION ESTIMATE METHOD TYPE OF SAMPLE TYPE No. No. Data Test Mean EP5-A Calculated IMPRECISION Systems Points h Value Point Estimates (mmol/l) SD %CV Within-run Serum Control 1 1 80 79.88 0.37 0.5 Serum Control 2 1 80 118.44 0.60 0.5 Urine Control 1 1 80 82.27 0.50 0.6 Urine Control 2 1 80 203.76 1.45 0.7 CSF Control 1 80 148.57 0.84 0.6 Total Serum Control 1 1 80 79.88 0.78 1.0 Serum Control 2 1 80 118.44 1.03 0.9 Urine Control 1 1 80 82.27 0.70 0.9 Urine Control 2 1 80 203.76 2.62 1.3 CSF Control 1 80 148.57 1.46 1.0 NOTICE These degrees of precision and equivalency were obtained in typical testing procedures on a SYNCHRON LX System and are not intended to represent the performance specifications for this reagent. ADDITIONAL INFORMATION For more detailed information on SYNCHRON LX Systems or UniCel DxC Systems, refer to the appropriate system manual. 11/03/2011 10 / 13

SHIPPING DAMAGE If damaged product is received, notify your Beckman Coulter Clinical Support Center. 11/03/2011 11 / 13

REFERENCES 1. Janz, G. J., Taniguchi, H., "The Silver-Silver-Halide Electrodes", Clinical Reviews, Vol. 52, 53:397-437 (1953). 2. Tietz, N. W., "Specimen Collection and Processing; Sources of Biological Variation", Textbook of Clinical Chemistry, 2nd Edition, W. B. Saunders, Philadelphia, PA (1986). 3. National Committee for Clinical Laboratory Standards, Procedures for the Handling and Processing of Blood Specimens, Approved Guideline, NCS publication H18-A, Villanova, PA (1990). 4. National Committee for Clinical Laboratory Standards, Routine Urinalysis and Collection, Transportation and Preservation of Urine Specimens, Tentative Guideline, NCS publication GP16-T, Villanova, PA (1992). 5. Tietz, N. W., ed., Fundamentals of Clinical Chemistry, 3rd Edition, W. B. Saunders, Philadelphia, PA (1987). 6. Tietz, N. W., Clinical Guide to Laboratory Tests, 3rd Edition, W. B. Saunders, Philadelphia, PA (1995). 7. National Committee for Clinical Laboratory Standards, How to Define, Determine, and Utilize Reference Intervals in the Clinical Laboratory, Approved Guideline, NCS publication C28-A, Villanova, PA (1995). 8. Henry, J. B., Clinical Diagnosis and Management by Laboratory Methods, 18th Edition, W. B. Saunders Company, Philadelphia, PA (1991). 9. Young, D. S., Effects of Drugs on Clinical Laboratory Tests, 4th Edition, AACC Press, Washington, D. C. (1995). 10. Friedman, R. B., Young, D. S.,Effects of Disease on Clinical Laboratory Tests, 3rd Edition, AACC Press, Washington, D.C. (1997). 11. Young, D. S., Effects of Preanalytical Variables on Clinical Laboratory Tests, 2nd Edition, AACC Press, Washington, D. C. (1997). 12. National Committee for Clinical Laboratory Standards, Method Comparison and Bias Estimation Using Patient Samples, Approved Guideline, NCS publication EP9-A, Villanova, PA (1995). 13. National Committee for Clinical Laboratory Standards, Evaluation of Precision Performance of Clinical Chemistry Devices, Approved Guideline, Vol. 19, No. 2, NCS publication EP5-A, Villanova, PA (1999). Beckman Coulter, Inc., 250 South Kraemer Blvd., Brea, CA 92821 11/03/2011 12 / 13

ENDNOTES a NSI = No Significant Interference (within ±4.0 mmol/l or 4%). b c Bias is based on worst case instead of average. Plus (+) or minus (-) signs in this column signify positive or negative bias. Plus (+) or minus (-) signs in this column signify positive or negative interference. d NSI = No Significant Interference (within ±4.0 mmol/l or 4%). e Intralipid is a registered trademark of KabiVitrum, Inc., Clayton, NC 27250. f g h NA = Not applicable. When the mean of the test precision data is less than or equal to the changeover value, compare the test SD to the SD guideline given above to determine the acceptability of the precision testing. When the mean of the test precision data is greater than the changeover value, compare the test % CV to the guideline given above to determine acceptability. Changeover value = (SD guideline/cv guideline) x 100. The point estimate is based on the pooled data from one system, run for twenty days, two runs per day, two observations per run on an instrument operated and maintained according to the manufacturer's instructions. 11/03/2011 13 / 13