ACCESS CONTROL SYSTEM FOR HOTELS HARDWARE SYSTEMS FOR WINDOWS AND DOORS

Similar documents
Ex15x //DATASHEET. Xs4 Mini. Cutting-edge design + Amazing technology:

CISA esigno Contactless Lock

Functional Specification Document

Wave Mode Contactless lock for hotels and other communities

Creation of Waferlock

SAFE-O-TRONIC access Door and furniture locking systems

ALWAYS THE SAFE CHOICE! Electronic door locking systems.

product brochure IMPLEMENTED

ABLOY EXIT. Functional and technical descriptions Single and double leaf doors. An ASSA ABLOY Group brand

KT40. Quick Guide Android 4.4.2

PD590-KT. Guide Android 4.4.2

Panic & emergency exit devices

Hotel room management software

A Fully Integrated Online Hotel Locking System

Information Technology Solutions

The only electronic locking system for hotels, halls of residence, geriatric hospitals that offers you an integral solution.


Point of view HDMI Smart TV dongle Mini RF Keyboard

Central Monitoring and Control Software for GRMS & Access Control

International Journal of Engineering Research & Management Technology

Ensto Chago Master EVM300 and EVM500 Operational description

Wireless N 300 Mini USB Adapter. Model # AWLL6086 User s Manual. Rev. 1.0

EAP N Wall Mount Access Point / WDS AP / Universal Repeater

GoldKey Software. User s Manual. Revision WideBand Corporation Copyright WideBand Corporation. All Rights Reserved.

Using RFID Techniques for a Universal Identification Device

DA BIOMETRIC FINGERPRINT READER 2,5" HDD ENCLOSURE User Manual

BUSINESS. Elektronisches Türschloss. Installation and User Manual. Ingeniously safe. Ingeniously simple.

An ASSA ABLOY Group brand. 4800LN Series. Interconnected Locks

Installation Process

Two-factor authentication Free portable encryption for USB drive Hardware disk encryption Face recognition logon

InSync Lock Series SAM RF Software. Key Control Systems for Multihousing

Tube-U(G) Long-Range Outdoor IEEE g USB Adapter User s Guide

Mechanical Entry Locksets

In-depth information about Sage 50 Accounts: In-depth specification

PU-USBX. USB over Ethernet Extender OPERATION MANUAL

Alber Training and Education Product Tutorial. Battery Monitor Data Manager Software (BMDM)

Contents. Introduction 1. System Components 1. HT22i Hardware Overview 13

GSM HOME SECURITY SYSTEM

Aperio Online. Aperio. Online Programming Application Manual. Aperio Online Quick Installation Guide, Document No: ST A, Date: 8 juli 2013

Samsung Drive Manager FAQ

Self-Check-In Hotels Using RFID. Technology

Onity Electronic Locking Solutions

Wireless-N. User Guide. PCI Adapter WMP300N (EU) WIRELESS. Model No.

OPEN PARK. Automatic Number Plate Recognition that works worldwide including Egypt Number plates

INFORMATION NOTICE WORKFORCE SERVICES

R&D Access Touch 3.1 User Manual Version 1.00 Public 1 (13) User Manual. Access Touch 3.1

USB Flash Security Free Edition Quick Start

COASTAL SERIES. 316 Solid Stainless Steel Door Furniture

Operating instructions TSE Wireless Software Home

SINGLE DEVICE FOR MULTIPLE TASKS

Cormant-CS System Requirements

ABLOY VEGA CABINET LOCKS

YALE DIGITAL DEADBOLT

SQL Server 2008 R2 Express Installation for Windows 7 Professional, Vista Business Edition and XP Professional.

3G USB Modem. Model AC327U. User Manual. February East Plumeria Drive San Jose, CA USA

PHA 2000 PHB 3000 EXIT PAD

Prerequisites Guide. Version 4.0, Rev. 1

TrueAlarm Fire Alarm Systems

TrustKey Tool User Manual

Golden N Wireless Mini USB Adapter. Model # AWLL6075 User s Manual. Rev. 1.2

Financial industry Solutions. Redefining Micro Location for the Financial industry in a Mobile World

Hotel Software Instruction Hotel Electronic Lock / Key Management Software Version 4.2u

Version Date Author Description Jpo First version Jpo FET output descriptions made clearer

JKW-IP. IP Video Entry System. QuikStart Guide

Voltage Regulator SPAU 341 C. Product Guide

Network Video Recorder. User s Manual v Model: SVR-504/508/516/516+

Installation Guide. Wireless N Access Point EAP110/EAP120/EAP220

Programming and Installation Instructions. Passed ISO international system ratification

Edge Metrics Data Center User Manual

BARCODE TICKET SOLUTION RF CARD SOLUTION MAGNETIC TICKET SOLUTION

Home security just got smarter.

How To Program A Powerline System On A Dgma1D (Dgma) With A Smartcard And A Powercard (Dm1D) On A Pcv123D (Powerline) On An Iphone Or

How To Set Up An E-Plex System Software (For Free) For A Laptop Or Ipad)

Adaptability to Enhanced Security

LINK GPS MGMT DATA. 5 GHz Carrier Backhaul Radio DATA MGMT GPS. Model: AF-5X LINK

LockView CompX Database & Network Configuration & Installation Manual

BabyWare Imperial PC Software

SALTO HAMS More than just software Much more than an interface. inspiredaccess. SALTO Systems HAMS Software

SmartSystems Foundation

Z-Wave Gas Reader. Product Manual NQ-9121-EU. From your Z-wave network directly to the cloud! DESCRIPTION

OPTAC Fleet Viewer. Instruction Manual

Adaptability to Enhanced Security

The MLS Guide to installing Silverlight on your Microsoft Windows or Apple Macintosh Operating System

Mitel 400 Hospitality Package

Seagate Manager. User Guide. For Use With Your FreeAgent TM Drive. Seagate Manager User Guide for Use With Your FreeAgent Drive 1

v1 System Requirements 7/11/07

ECB GHz Super G 108Mbps Access Point/Client Bridge/Repeater/WDS AP/

Introducing the Schlage NDE series wireless lock with ENGAGE technology

SMS Alarm. User Manual

Keywords RFID READER, FPGA, GSM.

Each ievo reader needs its own network cable, as each reader has its own IP address. Ensure this has been taken into consideration

GETTING TO KNOW YOUR TELSTRA PRE-PAID 3G WI-FI

WIRELESS MAGNETIC CONTACT

300Mbps Wireless N Gigabit Ceilling Mount Access Point

APPLICATION NOTE. The DMP Software Family DMP COMPUTER SOFTWARE PROGRAMS

Installation Manual for Multi-purpose Ecological Risk Assessment and Management Tool (AIST-MeRAM) For Windows 8

WUA Mbps Wireless USB Network Adapter

Development of Hybrid Radio Frequency Identification and Biometric Security Attendance System

1 System requirements (minimum)

Transcription:

ACCESS CONTROL SYSTEM FOR HOTELS HARDWARE SYSTEMS FOR WINDOWS AND DOORS

THE ONLY ELECTRONIC LOCK FOR HOTELS WITH MAGNETIC MOVEMENT. DESIGNED TO BLEND WITH THE INTERNAL DOOR, BASED ON THE AGB KNOW-HOW.

Magnetic movement latch Automatic activation bolt

TWIN LOCK DID YOU LOCK THE DOOR OF YOUR ROOM? No problem. Using twin lock you can only pull close the door. The twin lock system protects the security of your room. The magnetic latch comes out when the sash leans against the frame and the automatic bolt is activated ensuring the maximum antiburglar security. The magnetic movement latch creates new silence standard when the door closes. The bolt is in sintered steel to ensure great antiburglar resistance. 5

DESIGN MINIMAL APPROACH

Peerless personalisation The personalisation of the cover finish let the designer creativity free. Feel free to choose the handle The possibility to choose the handle gives more chances to the door designer: Opera Bit blends with every design style. Opera Bit is compatible with any kind of handle with through screws. Minimal perspective We opened the door to the finest design research. Opera Bit shows an innovative and minimal design, thanks to the little reader and the battery holder. The lock forend is essential thanks to the magnetic movement latch which disappears just opening the sash. The meeting point The striker is the same for flush and rebated doors, both right-hand and left-hand doors, even with different thicknesses. You can obtain 3 mm adjustment just turning the plate and the cover-tray. It avoids any problem due to difficult installation. 7

SECURITY ANTIBURGLAR, PRIVACY, SAFETY

Automatic bolt as standard The bolt is automatically released when you close the door. It guarantees the maximum security to the guest who can forget to lock the door. Do not disturb The 'Privacy' button allows the guests to sleep till late morning. When the "Do not disturb" is on, the staff can't enter the room. Antipanic lock From inside the room, bolt and spring latch are instantly released by simply lowering the handle for the immediate door opening. Shockproof The particular manufacturing process of the sintered steel bolt guarantees great resistance to impact. ROOM SIDE HALLWAY SIDE Emergency cylinder, one more chance You can unlock the door using the mechanic cylinder. It guarantees the manual door opening. Antiburglar strength The bolt protects the room from break-in attempts with deftness or tools. click click 9

RFID CARD CONTACTLESS TECHNOLOGY

Contactless The card has no direction and it works contactless, it's enough to approach it to the reader. It can be easily used by elderly people and children. Great lasting. The card isn't subject to wear and scratches. RFID RFID technology (Radio-Frequency Identification) is the best solution for the access control systems. It can't be duplicated. It can't be demagnetized. It can't be damaged with scratches, water or dirt. It can be re-programmed unlimited times. Multifunction The same card can be used for all the hotel functions, even if they are provided by third parts. Customizable graphic The card can be customized with the logo and the graphics of the hotel owner. Technical features MIFARE CLASSIC technology Frequency: 13,56 MHz Standard ISO/IEC 14443A Compatible with NFC technology 11

SYSTEM WHAT KIND OF USER ARE YOU? BIG HOTEL HOTEL CHAIN B&B SMALL HOTEL Opera Bit SPRINT version Choose the design and the security of the Opera Bit lock, using the simplicity of the accesses management offered by the SPRINT version. Opera Bit FULL version Design and security guaranteed by Opera Bit, together with a software that offers a complete management of accesses in rooms and common areas. Did you know that... Opera Bit is growing with you. Start with the SPRINT version; whenever you want, you can change to the FULL version, just installing the dedicated software without replacing the locks. Did you know that... You use a management software or an automation system for the room. Opera Bit, FULL version, can be interfaced with all the softwares in the market. 12

Simple & fast! SPRINT version Ready, set, go! You don't need any software or computer. Three special cards allow to manage the accesses in a simple and fast way. Activation card creates new cards. Reset card cancels the cards linked to a lock. Hold-Open card opens the doors in a permanent way (hold open device). Simplicity is on 1 2 3 Approach the Activation Card to the reader. The reader starts flashing. Approach a new card. The card is ready to open the door. 13

FULL version Complete and flexible accesses management The system is Stand Alone: it only requires a computer and a card writing device. Guests and Operators management Common areas management Time slots management Unlimited number of users Unlimited number of rooms Installation backup Conservation of previous accesses Check-In in 3 clicks! 3 clicks 14

FULL version, the software The dedicated software allows the fastest cards update, the common areas management and the assignment of permissions to the hotel staff. One system, two modules: Opera Bit Check-In Software for Check-In and Check-Out of guests and card authentication. The module is provided by a user-friendly interface and it can be easily used even by personnel without any information technology competence. Opera Bit Manager Software to plan and manage the plant system and the staff. It is able to manage even the most complicated systems. Do you use a management system or a RMS in your hotel? The Opera Bit, FULL version, is compatible with all the softwares provided by third parts. 203 Management system The interface with the management systems or with the RMS or with both of them allows to receive the guest just using the only Check-In software. 204 205 RMS 15

Comparative table of systems Full version Sprint version RFID Mifare technology Protection with password of installation Emergency cylinder Guests, Operators and Director cards Do not disturb function Passage door function Mechanical energy saver Energy saver with card writing Guest Card / Operator Card AGB card Card use for several applications Integration with Room Management Systems Management of Cards validity time Check-In / Check-Out of guests Complex keyplans Installation backup Check the installation status Guest card loss Blacklist / Card expiration Reset card Operator card loss Blacklist Reset card Supervisor card loss Blacklist Intervention of Assistance Activation card loss Send new card Intervention of Assistance Low battery warning LED on door and software LED on door Maximum quantity of rooms 65.000 * Maximum quantity of authorized guests cards for a room Unlimited 50 Maximum quantity of authorized operators cards for a room Unlimited 50 Management of common accesses ** Management of housekeeping accesses Management of time slots Management of previous accesses Time slots Software required Installation required * We suggest the SPRINT version for a number of rooms lower than 20, in order to guarantee an efficient management. ** With the Sprint version, if there is a common access and the card has been lost, it is necessary to authorize every active card in that lock again. This could be an incovenience for the guests.

Technical information Application Antipanic function Door thicknesses Emergency cylinder Handle Hub dimensions Lock finish Cover finish For hotel doors and accomodation facilities One antipanic side and one that can be activated by card 40-100 mm (44-63 mm with fastening screws included in kit) Euro-profile cylinder Fastening with through screws 8 mm hub Matt chromium plated, Brass plated, Nickel plated, Bronze plated Other finishes are available on request Wide range of finishes can be combined with door and handle Temperature for use -10 / +55 C Battery supply (suitable for hotels under renovation or new-build hotels) Battery duration Power supply (suitable for new-build hotels) Warning signal Opera Bit software Registration of events Privacy / Do not disturb Card writing technology Wireless technology Cryptography Electronic certification 3 alkaline AA batteries (LR6) 18/24 months, according with the conditions for use 12-24V CC 1 LED inside the room and 2 LEDs outside in order to signal authorizations, warnings and low batteries Minimum requirements: CPU x86/x64 2GHz, RAM 2GB, HDD 2GB, NET Framework 4, SQL Server 2008 R2 Supported systems: Windows XP SP3, Vista, 7, 8, 8.1 (except Starter Edition) Up to 1000 events stored in non-volatile memory "Do not disturb" function can be activated from inside the room to forbid the entry of the housekeeper Mifare Classic IEEE 802.15.4 / 2,4 GHz 128-bit AES encryption Opera Bit fullfills the essential requirements and any other applicable disposition of the regulations 1999/5/CE and 2004/108/CE CE marking EN 14846 Fire resistance Tested against fire according with the EN 1634-1 17

Features of lock and striker 3 18/22 3 22 3 104,5 38 59 26 46,5 15 11 38 38 67 85 55 207 8 6 274 18,5 20 238 274 20 20 8 8 76 85 64 70 26 78 91 54 225 70 30 ADJUSTMENTs ±1,5 mm 61 16 30 69 A C 10 5 CYLINDER CHOICE C max. = A+1 C min. = A-5 18

operabit.agb.it Alban Giacomo spa Via A. De Gasperi, 75 36060 Romano d Ezzelino (VI) Italy +39 0424 832 832 www.agb.it - info@agb.it Z90029.02.25-09.15 - Communications Dept. - Printed in Italy The supplied data and pictures are to be considered valid saving any printing error or modifications introduced by the manufacturer.