7800 SERIES Q7800A,B 22-Terminal Universal Wiring Subbase

Similar documents
Q309A,B; Q335C; Q340A; Q390A Thermocouples and Q313A,B,C,F Thermopile Generators

T7079A,B Solid State Remote Temperature Controllers

7800 SERIES RM7838B,C Relay Module

SIL 3 Capable. RM7890A,B,C/EC7890A,B 7800 SERIES Relay Modules SPECIFICATIONS APPLICATION INSTALLATION INSTRUCTIONS

Solid Core and Split Core Adjustable Current Status Switches CSS-O, CSS-C; CSP-O, CSP-C

How To Use A Power Supply With A Powerline 2.2 (Powerline) And Powerline 3.2 Power Supply (Powerplant)

7800 SERIES EC7895A,C; RM7895A,B,C,D and RM7896A,B,C,D Relay Modules

LIEBERT VNSA Installation Sheet

UV100A Ultraviolet Air Treatment System

Y7230A CO 2 Alarm System

MTE SERIES RLW. World REACTORS USER MANUAL PART NO. INSTR 030 REL MTE Corporation

VU53S; VU54S; VU443A; VU444A; VU843A; VU844A Fan Coil Valves and Actuators

Automatic Transfer Switch FT-10 Network Control Communications Module (CCM-T) Kit

Installation. Smart-UPS VT MGE Galaxy Maintenance Bypass Panel kva 400 V

PT-6000 Power Tower INSTALLATION MANUAL SPECIFICATIONS

Disclaimers. Important Notice

PowerFlex 700S and 700H Frame 12 DC Bus Connector Kit

Agilent 87421A/87422A Power Supply

Metallic and Non-Metallic Air Conditioning Disconnects. A Complete Family of. Disconnects with Exclusive Time Saving Features

INSTALLATION MANUAL ELECTRIC RANGE. Please read these instructions thoroughly before installing and operating the range.

PS4-24 OWNERS MANUAL 24 VAC 90 WATT WALL MOUNTED CCTV POWER SUPPLY

HMI display Installation Guide

AMPSEAL* Automotive Plug Connector and Header Assembly

Installation Instructions For Slider Casement Air Conditioners

Power supply unit Model: PAC-SC50KUA

Seismic Installation for Attic Storage System

PART 8: FIELD WIRING. n WARNING NOTICE. Boiler Manual

ETC TWO STAGE ELECTRONIC TEMPERATURE CONTROL

Electrical Grounding. Appendix C

PowerFlex 700H and 700S AC Drives Frame 11 Main Fan Capacitor Replacement Kit

Installation Instructions

TraceTek TTDM Series Leak Detection and Location Modules Replacement Parts Installation Instructions

Circuit Breakers. Next Generation of Protection Capabilities

T7560A,B,C Digital Wall Module

IntelliBrite Controller (For IntelliBrite Pool, Spa and Landscape Lighting Fixtures) Installation and User s Guide

How To Install A Gel Doc Xr+ Camera On A Computer Or Mouse Or Tv (For A Powerbook) With A Zoom Lens (For An Ipa) With An Iphone Or Ipa (For Mac) With The Zoom Lens

HE220A,B and HE260A,B Bypass Flow-Through Humidifier

RMM2 Heat-Tracing Remote Monitoring Module for the Raychem NGC Control System Installation Instructions

The table below lists the symbols used on the Clamp and/or in this manual. Important Information. See manual.

Owner s Manual. For Automatic Transfer Switch Amp, Service Entrance/Non-Service Entrance

MCR1900 Media Converter 19-Slot Chassis

RayClic Connection System Installation Instructions

12VDC MAGNETIC LED DIMMABLE POWER SUPPLIES SPEC SHEET DIGEST

EVC40 EMERGENCY VOICE COMMUNICATION SYSTEM

ELECTRIC METERING COMMERCIAL & INDUSTRIAL

PRESSURE AND TEMPERATURE SENSORS for use with the BURNERLOGIX Burner Management System and PPC4000 Series Fuel/Air Ratio Controller

G670 Intermittent Pilot Ignition Controls

Drayton Digistat +2RF/+3RF

AMFA-27 AMFA-29. Operator s Manual & Installation Instructions. Rev. 2.5

36G22, 36G23, 36G24 & 36G52 36J22, 36J23, 36J24 & 36J52 DSI and HSI Single Stage Combination Gas Valve

ELECTRICAL GUIDELINES FOR SINGLE-FAMILY HOME OWNERS:

INSTALLATION & SERVICE MANUAL. Display Panel

IMPORTANT SAFETY INSTRUCTIONS

TIG INVERTER INSTRUCTION MANUAL

VIEW. SLX300 SpeakerLinX IP Zone. Amplifier Installation and Setup Guide. AVoIP

A99B Series Temperature Sensors

12S, 14S, 15S Series. Time Delay Relays and Sequencers. Time Delay Relays and Sequencers. Features and Benefits. Switch Actions and Configurations

Achat 115MA full-range speaker. user manual

Suitable for Emergency, Peak and Prime Power System Applications. Low Voltage Automatic Transfer Switch Systems

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS

E2 Series Electric Furnaces

! WARNING. Before using product, read and understand instructions.

SKP Series SKP15U.. Gas Valve Actuator with Safety Shutoff Function

KZ0224UW INSTALLATION MANUAL SURGE PROTECTED CCTV POWER SUPPLY 24V AC, 5 AMP KZMI /12/01

AMF112 Instruction Manual

HERZ-Thermal Actuators

DRM75A 230V 20/100A DIN rail single phase two wire energy meter

High PoE Midspans NPD-6001A NPD-9501A. en Installation Manual

SELECTION, APPLICATION AND MAINTENANCE

ATS Overhead Table Shelf System INSTRUCTION MANUAL

MIC-WKT and MIC-WKT-IR

Model 1756 Test Lead Kit

INSTALLATION AND OPERATING INSTRUCTIONS For Model GL1 Gate Locks

Installation Instructions

How To Build A Powerline Box Powerline Generator

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM

Video Camera Installation Guide

Operator: Save these instructions for future use!

REV. REL 1302 WEST BEARDSLEY AVENUE P.O. BOX 1127 ELKHART IN (574) FAX (574) ELKHART BRASS MFG. CO., INC.

S03, S05 Series Low-Torque Spring- Return Direct-Coupled Actuators

TYPE 65UV CEX Integrated Flame Scanner with Internal Flame Relay and Analog Output

Explosion proof enclosures

ARCO Electric Products Installation and Maintenance Manual Low Voltage Automatic Power Factor Correction Capacitor Systems 2013

Series 71, 72, and 76 Modutrol IV Motors

Installation Guide. VisionPRO. TH8000 Series. Need Help? This manual covers the following models. System Types

TYXIA. * _Rev.1* Installation and User Guide. Wireless receiver. TYXIA RF channel

METER REQUIREMENTS GENERAL REQUIREMENTS SECTION D

StackFlowMaster FPD580 TORBAR probe Stack gas metering systems. Measurement made easy. Introduction. For more information

Doorbell Intercom Security System

Instruction Bulletin. MCS025 Sync-Check Module Installation Sheet

INTRODUCTION INTERLOCK KIT K-8110

VSD Series Drives. November 2009 Supersedes September Powered by Eaton Technology. User Manual

Conext Grid Tie Solar Inverter Conext TX 2800 NA Conext TX 3300 NA Conext TX 3800 NA Conext TX 5000 NA

All work must conform to the National Electric Code, latest edition, and all other applicable codes and regulations.

ALTERNATIVE METHODS FOR INTERNAL ARC TESTS ON 12 KV AND 24 KV METAL-ENCLOSED SWITCHGEARS WITH COMPACT RMU

Mobile Data Power Model: MDP-25

CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN

vacon 100 vacon 100 flow vacon 100 hvac ac drives installation manual wall-mounted drives

Manual. Simrad StructureScan LSS-1 Sonar Module. English

Transcription:

7800 SERIES Q7800A,B 22-Terminal Universal Wiring Subbase FEATURES PRODUCT DATA Quick-mount wiring subbase for all 7800 SERIES Relay Modules and S7830 Expanded Annunciator. Allows wiring of control system before installation of relay module. Can be panel mounted (Q7800A) or burner or wall mounted (Q7800B). Access slots provided for electrical measurements. NEMA enclosure. Electrical access slot covers provided with Q7800B; available option for Q7800A. APPLICATION The Q7800A,B is a universal wiring subbase for the 7800 SERIES Relay Modules and Expanded Annunciator (S7830A). The universal wiring subbase provides terminals for field wiring. Knife blade terminals located on the 7800 SERIES Relay Module or S7830A engage the Q7800 bifurcated contacts to make electrical connections. The Q7800A005 (2-sided) subbase is available for panel mounting applications. The Q7800B003 and Q7800B0 (4-sided) subbases are available for burner or wall mount applications. Knockouts are provided in the back, top and bottom for conduit connections. U.S. Registered Trademark Copyright 998 Honeywell Inc. All Rights Reserved 65-0084-3

SPECIFICATIONS Weight: Q7800A: 7 ounces. Q7800B: pound, 3 ounces. Dimensions: See Fig., 2 and 3. Enclosure: NEMA. Approval Bodies: Underwriter Laboratories Inc. Component Recognized: File no. MP268, Guide no. MCCZ2 (Q7800A),Listed: File no. MP268, Guide no. MCCZ (Q7800B). Canadian Standards Association Certified: LR95329-3. To meet EN60730 approval, the Q7800 subbase must be mounted in a secured panel which meets IP40 class of protection. Accessories: Electrical Access Slot Covers, part no. 22779 (Q7800B). USE NO. 6 MOUNTING SCREWS (4) G L2(N) 3 4 5 6 7 8 9 0 F 2 3 4 5 6 7 8 9 20 2 22 2-/2 (64) -/32 4-3/32 (26) -/32 2-9/32 (58) 4-3/32 (26) OPTIONAL TERMINAL TEST ACCESS COVER. -3/32 (36) Fig.. Top and front view of Q7800A005 Wiring Subbase (2-sided) with dimensions in in. (mm). M968B ORDERING INFORMATION When purchasing replacement and modernization products from your TRADELINE wholesaler or distributor, refer to the TRADELINE Catalog or price sheets for complete ordering number. If you have additional questions, need further information, or would like to comment on our products or services, please write or phone:. Your local Home and Building Control Sales Office (check white pages of your phone directory). 2. Home and Building Control Customer Logistics Honeywell Inc., 885 Douglas Drive North Minneapolis, Minnesota 55422-4386 (62) 95-000 In Canada Honeywell Limited/Honeywell Limitée, 55 Gordon Baker Road, North York, Ontario M2H 3N7. International Sales and Service Offices in all principal cities of the world. Manufacturing in Australia, Canada, Finland, France, Germany, Japan, Mexico, Netherlands, Spain, Taiwan, United Kingdom, U.S.A. 65-0084 3 2

23/32 (8) /2 (9) 2-/8 (54) (25) 7/8 in. DIA. KNOCKOUTS (7) FOR /2 in. CONDUIT USE NO. 6 MOUNTING SCREWS (4) 2-/4 (64) -/32 G L2(N) 3 4 5 6 7 8 9 0 F 2 3 4 5 6 7 8 9 20 2 22-3/32 (36) -5/8 (4) 27/32 (2) 4-3/32 (26) -/32 4-3/32 (26) 2-9/32 (58) 2-7/32 (56) 2-/8 (54) (25) 3/4 (9) REMOVE ONLY FOR TERMINAL TEST ACCESS. 23/32 (8) M966A Fig. 2. Top and front view of Q7800B003 Wiring Subbase (4-sided) with dimensions in in. (mm). 3 65-0084 3

23/32 (8) 3/4 (9) 3/4 (9) 2-/8 (54) (25) 7/8 in. (22) KNOCKOUTS (9) FOR /2 in. CONDUIT USE NO. 6 MOUNTING SCREWS (4) 2-/4 (64) -/32 G L2(N) 3 4 5 6 7 8 9 0 F 2 3 4 5 6 7 8 9 20 2 22-3/32 (36) -5/8 (4) 27/32 (2) 4-3/32 (26) -/32 4-3/32 (26) 2-9/32 (58) 3 (76) 2-/8 (54) (25) 3/4 (9) REMOVE ONLY FOR TERMINAL TEST ACCESS. 3/4 (9) 23/32 (8) M9883 Fig. 3. Top and front view of Q7800B0 Wiring Subbase (4-sided) with dimensions in in. (mm). 65-0084 3 4

INSTALLATION When Installing this Product. Read these instructions carefully. Failure to follow them could damage the product or cause a hazardous condition. 2. Check the ratings given in the instructions and on the product to make sure the product is suitable for your application. 3. Installer must be a trained, experienced, Flame Safeguard service technician. 4. Disconnect the power supply before beginning installation to prevent electrical shock and equipment damage. More than one disconnect may be involved. 5. All wiring must comply with applicable local electrical codes, ordinances, and regulations. 6. All wiring must be NEC Class (Line Voltage). 7. After installation is complete, check out product operation as provided in these instructions. CAUTION Disconnect power supply before beginning installation to prevent electrical shock and equipment damage. More than one disconnect may be involved. Follow the equipment manufacturer instructions if available; otherwise, proceed as follows below. MOUNTING NOTE: For installation dimensions, see Fig. and 2.. Place the subbase in a location within the ambient temperature rating of the 7800 SERIES Relay Module and S7830A being used. Refer to the appropriate Instructions. 2. Mount the subbase in any position except horizontally with the bifurcated contacts pointing down. The standard vertical position is recommended. 3. Select a wall, burner or electrical panel location. Or mount the Q7800 directly in the control cabinet. Be sure to allow adequate clearance for servicing, installation, access or removal of the 7800 SERIES Relay Module, S7830A, Keyboard Display Module, Run/Test switch, flame amplifier signal voltage probes, electrical signal voltage probes and electrical field connections. IMPORTANT Do not mount the wiring subbase horizontally with the bifurcated contacts pointing down. 4. For surface mounting, use the back of the subbase as a template to mark the four screw locations. Drill the pilot holes. 5. Insert the mounting screws using four no. 6 screws tightened securely. WIRING. Refer to the equipment manufacturer s wiring information and the appropriate 7800 SERIES Relay Module or S7830A Specifications for correct subbase wiring. 2. Provide overload protection and disconnect means as required. Disconnect the power supply from the main disconnect before beginning installation to prevent electrical shock and equipment damage. More than one disconnect may be involved. 3. All wiring must comply with appropriate electrical codes, ordinances and regulations. Use NEC Class (Line Voltage) wiring. 4. Recommended wire size and type is to use up to two no. 4, 6, or 8 copper conductors TTW60C, THW75C or THHN90C, 600 volt insulation wire for all Line Voltage terminals. For high temperature installations, use wire selected for a temperature rating above the noted maximum operating temperature. The flame detector leadwires should be moisture resistant. a. For the ignition leadwire, use Honeywell specification no. R0602 Ignition Cable or equivalent. (This wire is rated at 350 F (77 C) for continuous duty, and up to 500 F (260 C) for intermittent use. It has been tested to 25,000 volts.) b. For the flame detector F leadwire, use Honeywell specification no. R298020 or equivalent. (This wire is rated at 400 F (204 C) for continuous duty. It is tested for operation up to 600 volts and breakdown up to 7500 volts.) c. For ignition installation in a contaminating environment, use Honeywell specification no. R23900 High Tension Ignition Cable or equivalent. (This wire is resistant to severe conditions of oil, heat and corona, and is tested to withstand high voltages up to 25,000 Vrms in a salt bath for one minute without breakdown. It is rated at 200 F (93 C) for continuous duty, and up to 350 F (77 C) for intermittent use.) 5. Recommended grounding practices: a. Each 7800 SERIES Relay Module or S7830A will have an earth ground terminal G that must be grounded to the metal control panel with wire as short as practical. Each ground wire must be capable of carrying a fault current equal to the rating of the protective fuse (20 amperes); a number 4 copper conductor is adequate. b. The earth ground provides a connection between the subbase and the control panel or the equipment. The earth ground wire must be capable of conducting the current to blow the 20A fuse (or breaker) in event of an internal short circuit. The 7800 SERIES Relay Module needs a low impedance ground connection to the equipment frame which, in turn, needs a low 5 65-0084 3

impedance connection to earth ground. For a ground path to be low impedance at RF frequencies, the connection must be made with minimum length conductors that have maximum surface areas. Wide straps or brackets are preferred rather than leadwires. Be careful to ensure that mechanically tightened joints along the ground path, such as pipe or conduit threads or surfaces held together with fasteners, are free of nonconductive coatings and have corrosionprotected mating surfaces. 6. Recommended wire routing for flame detector leadwires: a. Do not run high voltage ignition transformer wires in the same conduit with the flame detection wiring. b. Do not route scanner wires in the same conduit with line voltage circuits. c. Scanner wiring not utilizing armor cable should be enclosed in metal cable or conduit. d. Follow directions in Flame Detector Instructions. CHECKOUT After installation, perform a complete checkout of the system. Follow information supplied by equipment manufacturer and instructions furnished with the 7800 SERIES Relay Module or S7830A. SERVICE NOTE: Voltage checks can be accomplished by using the electrical access slots on the sides of the Q7800A,B. Remove the electrical access slot covers on the Q7800B before making the voltage checks. WARNING Electrical Shock Hazard. Can cause serious injury or death. Replace the electrical access slot covers on the Q7800B after performing voltage checks or anytime they are removed. 7. Maximum wire lengths for flame detector leadwires are limited by the flame signal strength. 8. Make sure that loads do not exceed terminal ratings; refer to the labels on the 7800 SERIES Relay Module, or S7830A, or ratings in the 7800 SERIES Relay Module or S7830A Specifications. 9. Check the power supply circuit. The voltage and frequency tolerance must match those of the 7800 SERIES Relay Module or S7830A. Do not connect the 7800 SERIES Relay Module or S7830A to a power supply circuit that is subject to line voltage variations, such as would occur with on-off switching of heavy loads. A separate power supply circuit may be required for the 7800 SERIES Relay Module or S7830A. Add the required disconnect means and overload protection. 0. Check all the wiring circuits and complete a Static Checkout according to the 7800 SERIES Relay Module or S7830A Specifications before installing the 7800 SERIES Relay Module or S7830A on the subbase.. Install the 7800 SERIES Relay Module or S7830A. 2. Restore power to the panel. IMPORTANT Do not run high voltage ignition transformer wires in the same conduit with the flame detector wiring. IMPORTANT Make sure no subbase wiring is projecting beyond the terminal blocks. Tuck wiring in against the back of the subbase so it does not interfere with the knife blade terminals or bifurcated contacts. 65-0084 3 6

7 65-0084 3

Home and Building Control Honeywell Inc. Honeywell Plaza P.O. Box 524 Minneapolis MN 55408-0524 Honeywell Latin American Region 480 Sawgrass Corporate Parkway Suite 200 Sunrise FL 33325 Home and Building Control Honeywell Limited-Honeywell Limitée 55 Gordon Baker Road North York, Ontario M2H 3N7 Honeywell Europe S.A. 3 Avenue du Bourget 40 Brussels Belgium Honeywell Asia Pacific Inc. Room 323-3225 Sun Hung Kai Centre No. 30 Harbour Road Wanchai Hong Kong Printed in U.S.A. on recycled paper containing at least 0% 65-0084 3 68-0084 3 G.R. Rev. -98 post-consumer 8 paper fibers. www.honeywell.com