Description. Features. Design Considerations

Similar documents
RF Maestro Local Controls

Switching Power Module

EcoSystem Dimming Power Module for 3-wire Lutron Dimming Ballasts. EcoSystem One-Line. EcoSystem C5-BMJ-16A. EcoSystemR Dimming Module

How To Use A Lutron Power Supply

Dimmer and Bulb Compatibility

Operation Manual. 150 Watt Halogen Light Source for Endoscopy Model # s ESS-150, ESS-150A ESS-220, ESS-220A

HomeWorks QS Processor

Phase-Adaptive Power Module

Transmitter Actuator 230V wave UP 560. Operation

Dual Technology Ceiling Mount Sensor

LED Security Spotlight User Manual

PT-6000 Power Tower INSTALLATION MANUAL SPECIFICATIONS

LED MOTION ACTIVATED FLOOD LIGHT

Table of Contents. What to Expect with. Preparation. Tools Needed. Wiring. Hanging the Fan. Blades. Motor Housing.

WARNING CANADIAN D.O.C. WARNING

LS-1 Series Tungsten Halogen Light Sources Installation and Operation Instructions

LED MOTION ACTIVATED FLOOD LIGHT

OSRAM DULUX SUPERSTAR MICRO TWIST

RC8021 Indoor Camera Installation Guide

Square D Clipsal DIN-Rail Four-Channel Auxiliary Input Unit

CortezTM A Kichler Décor Ceiling Fan

M A R C O. CP-670 AUTOMATIC CHART PROJECTOR Instruction Manual

Owners & Installation Manual for the Sheridan, Mountainair, Pine Valley and Old Forge Ceiling Fan Family

On/Off Relay Switch and 3-Way Switch Kit

4.3-inch Back-Up Camera

Understanding LED Drivers

FIXTURE INSTALLATION GUIDE Model T21T (Low Voltage Pendant Set 120V)

EBDSPIR-PRM, EBDSPIR-PRM-IP

Installation and operating instructions: Radio dimmer Type: DALI DM ADVANCED LI

Cove lighting and tight space RGB LED luminaire

Wireless Lighting Control. On/Off/Dim. Dimmer Switch.

Installation and User Guide

Operating Instructions Bedienungsanleitung Mode d emploi

Installation Manual. Features SMART SWITCH OCCUPANCY SENSOR. Maximum Energy savings

Medical Lighting. XL4 Patient Light

Antenna Splitter ASA 1. Instruction manual

Transmitter Speed. Instructions for use Betriebsanleitung Mode d emploi Instrucciones para el uso Istruzioni per l uso

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

FLUORESCENT UV- RING LIGHT OPERATING INSTRUCTION

Wireless Indoor/ Outdoor Thermometer

GLPHASE System. System Components GLPHASE - KP- KP- KP- KP- OS- DS SpaceBuild Specification Worksheet. Touch Screens

Energy meets efficiency

15 Series - Electronic step relay and dimmer. Features SERIE

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

FB-500A User s Manual

=============================== WARNING

Indoor/Outdoor Color Camera with Built-in 2.4 GHz Wireless Transmitter, plus X10 controlled power supply, and Video Receiver.

Flame Direct Attach UV-VIS Integrated Sampling System Installation and Operation Instructions

Perle Protocol Transparent Media Converter Modules

LOW-VOLTAGE TRANSFORMER QUICK START GUIDE PLANNING GUIDE INSTALLATION GUIDE

ISL-540 TBTS SERIES D EMERGENCY LIGHTING EQUIPMENT

SP1790JK 900MHz Wireless Indoor/Outdoor Speakers. User Manual INTRODUCTION FEATURES IMPORTANT SAFETY INFORMATION

LiteAide OWNER'S MANUAL PREASSEMBLED AUTOMATIC SECURITY FLOODLIGHTS MOTION SENSOR SECURITY LIGHTING SYSTEMS

INSTALLATION INSTRUCTIONS

StructureScan HD Module. Installation Guide ENGLISH

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS

Advantium 2 Plus Alarm

Features: Mounting the Optic

Touch Tone Controller. Model TR16A. Owner s Manual

User s Manual for S and L series Fluorescent Lights.

IVIOS LED III. LUM Technical Information

Installation Guide A Delta T Corporation

Model PS-4001 Power Supply User Instructions

AMERBRITE UNDERWATER WHITE LED POOL LAMP

Drayton Digistat +2RF/+3RF

GE Lighting Solutions. Albeo LED Luminaire. Modular High & Low Bay Lighting. (ABHX - Series) imagination at work

Digidim 458/DIM8 8-Channel Dimmer Module. Installation and User Guide

ColorDial Pro Easily configure and control LED light shows

WARNING! DO NOT ATTEMPT TO INSTALL THIS KIT IN A POWERED CONVEYOR.

Error! Bookmark not defined. Error! Bookmark not defined. Error! Bookmark not defined.

AXIS T81B22 DC 30W Midspan

Cross-beam scanning system to detect slim objects. 100 mm in

LED Bulb Manual. Aeotec by Aeon Labs LED Bulb.

GRX-PWM Pulse Width Modulation Interface

Configuration Instructions

Basics of Dimming. ISC Learning Centre

User Guide. HDMI Active Cable Extender. DVI-7370c

Lighting Controls ! WARNING RISK OF ELECTRIC SHOCK. Installation Instructions DESCRIPTION

IDDERO HOME SERVER. Quick start guide

INSTALLATION AND OPERATING INSTRUCTIONS For Model GL1 Gate Locks

SECTION INTERIOR LIGHTING FIXTURES, LAMPS, AND BALLASTS

LANTANA LUMINAIRE HI-LUME 1% ECOSYSTEM LED DRIVER L3DA4U1UMN-XXXXX

7 High-Resolution Digital Photo Frame

Cooktop Low-Profile Ventilation Hoods

WPR400 Wireless Portable Reader

Operating Instructions

Installation Guide X Delta T Corporation

QFP910. Water detector. Building Technologies. CE1N2732en. Synco living

ScreenLogic Wireless Connection Kit. Installation Guide. pool/spa control system

Product and functional description

Manual. Simrad StructureScan LSS-1 Sonar Module. English

IntelliBrite Outdoor Landscape LED Color-Changing Light

KEYPAD LOCK RETROFIT KIT

Linear Recessed Center Basket Fixture. Lutron

Product Manual. ABB i-bus KNX. Universal Dim Actuator, MDRC UD/S Intelligent Installation Systems ABB

Installer s Guide WARNING: 18-GJ11D1-2. Ultraviolet (UV-C) Lamp Kit for 2-5 Ton Air Handlers HAZARDOUS VOLTAGE - DISCONNECT POWER BEFORE SERVICING

Reference Design. conference rooms

LTR Series Uninterruptible Power Systems 700 VA KVA. General Specification

3x cinch/s-video socket Order no.: xx. USB/3.5 mm audio socket Order no.: xx. VGA socket Order no.: xx

2.0 Installation 1. Remove the cover using a small flat blade screwdriver. Figure 2: Cover Removal

Transcription:

sz-1sd 1 07.31.09 Description The Stanza system is an easy-to-install and easy-to-use lighting control system designed especially for hotel guest rooms and similar applications. The system consists of wallbox dimmers, wallbox switches, line-voltage wallbox keypads, low-voltage interfaces, and lamp socket dimmer/switches. All of these devices communicate via radio frequency (RF) within each individual guest room. Stanza lamp socket dimmer/switches allow guests to control a local lamp by rotating the knob at the socket. They can be controlled remotely via other Stanza components. SZ-1SD Features Fits standard Edison medium-bore (E26) lamps. Allows local dimming control of halogen and incandescent lamps, and switching (toggle On/Off) control of compact fluorescent lamps. Light level can also be adjusted, if addressed as part of a Stanza lighting control system, via an RF command from a keypad or integration device. Provides auditory feedback when knob is rotated. Lamp harp locking mechanism (provided) deters theft. Large knob designed with ADA and Universal Design considerations. Design Considerations The lamp socket dimmer/switch cannot be used on lamps with integral dimmers. For lamps with integral switches, the integral switch must be left in the on position for proper operation. Ensure that proper space exists in the lamp harp and from the bulb to the shade of the lamp being used. See Installation Notes in this document and Lutron Application Note #243 at www.lutron.com for more information. Always use a bulb that remains within the wattage rating of the table or floor lamp.

sz-1sd 2 07.31.09 Specifications Standards: UL listed to standard 496 lampholders NOM listed to standards NOM 003 and NMX508 CUL listed to standard C22.2 no. 43, lampholders, and ICA registered FCC approved. Complies with the limits for a Class B digital device, pursuant to Part 15 of the FCC rules Power: Operating voltage: 120 V 50/60 Hz Non-permanently connected fixtures only Load: Always use a bulb that remains within the wattage rating of the table or floor lamp. 10 W minimum for incandescent, halogen, and fluorescent. For base-down orientation, maximum 150 W incandescent, 100 W halogen, and 30 W fluorescent. (See Derating under Installation Notes if not installed base-down.) Dims a single halogen or incandescent bulb Can be configured to switch a single compact fluorescent bulb Key Design Features: Unit ships from factory as a switch and must be configured to control dimmable loads when the system is commissioned Green LED status indicator shows current load status LED turns amber for programming indication LED turns red and turns off load output if an over-temperature condition is detected Adjustable maximum light level provides energy savings and extended bulb life Power failure memory: if power is interrupted, when the power is restored, lamp will return to its previously set level prior to the interruption Light level can be fine-tuned by rotating the knob until the desired light level is reached (dimmable loads only) Lamp socket dimmer/switch must be installed below or beside bulb, not above bulb Dimensions: 1.85 in (47 mm) wide 3.74 in (95 mm) deep 1.6 in (41 mm) added height above socket System Communication and Capacity: Lamp socket dimmer/switches communicate with other Stanza system components through radio frequency (RF) at 434 MHz Multiple RF channels and thousands of system addresses prevent interference between systems Each lamp socket dimmer/switch counts as 1 toward the single-system maximum of 31 Stanza devices (Maximum devices can be increased to 100 if an SZ-CI-PRG is present in the system) Environment: Ambient operating temperature: 32-104 F (0-40 C) Maximum 90% non-condensing relative humidity Indoor use only Warranty: 1-year limited warranty 2-year full parts and labor warranty, with 8-year pro-rated parts replacement on commissioned systems Color/Finish Codes: White only

Mounting and Dimensions sz-1sd 3 07.31.09 1.85 in (47 mm) 3.74 in (95 mm) 1.6 in (41 mm) added to bulb height Installation Notes WARNING! RISK OF FIRE It is important to maintain proper spacing between the bulb and the lamp shade. When the lamp socket dimmer is installed, spacings A and B (as seen in the diagram below) should be equal to or greater than required by the original UL listing for this portable lamp. Portable lamps are listed to UL 153, Portable Electric Luminaires. This standard specifies minimum spacings for A and B based on the construction of the lamp and the rated wattages of acceptable bulbs. Consult the lamp manufacturer for this information. Lutron recommends that the spacings with the lamp socket dimmer installed be equal to or greater than what they were without the lamp socket dimmer installed. This may require a new lamp harp. See Lutron Application Note #243 at www.lutron.com for more information. A B A B is the spacing to the top of the shade (this applies only to shades with a closed top) A B is the spacing to the nearest point of the shade UL Listing of Portable Lamps with Lutron s Lamp Socket Dimmer Lutron s lamp socket dimmer is UL listed to standard #496, Lampholders, while portable lamps are UL listed to standard #153, Portable Electric Luminaires. A portable lamp with the lamp socket dimmer pre-installed by the lamp manufacturer can be UL listed as an assembly under UL 153. For more information, contact your portable lamp manufacturer.

Installation Notes (continued) Always use a bulb that remains within the wattage rating of the table or floor lamp Unplug fixture before installing lamp socket dimmer/switch or changing bulb To install lamp socket dimmer/switch, remove bulb from socket, screw lamp socket dimmer/switch into lamp socket, then replace bulb in lamp socket dimmer/switch socket sz-1sd 4 07.31.09 Lamp harp may need to be removed during installation Mount lamp socket dimmer/switch between base-down and horizontal Slide harp lock onto bottom of harp and tighten with 1/16 in (1.5 mm) hex wrench (not provided) Allowable mounting orientations: Base-down to horizontal These mounting orientations not allowed Derating Orientation Base-down From base-down to horizontal Rating 150 W incandescent 100 W halogen 30 W compact fluorescent 100 W incandescent 75 W halogen 30 W compact fluorescent Lamp socket dimmer/ switch Harp lock Hex wrench R

Potential Lamp Harp Interference Issues sz-1sd 5 07.31.09 The Lutron is designed to fit in a large variety of typical table and floor lamps. However, due to the large variability in lamp designs, the may not fit into all lamps. There are three main scenarios where the may not fit into a lamp that uses a lamp harp to support the shade. Please refer to the Terminology section on the last page for a definition of terms. Harp too short Figure 1 Harp too narrow Figure 2 Harp not aligned Figure 3 These can be addressed with proper selection and installation of a compatible harp or proper alignment of the harp parts.

sz-1sd 6 07.31.09 Solutions Harp too short (Figure 1) The adds approximately 1.6 in (41 mm) of height to a standard bulb. In some cases, this may cause the top of the bulb to come into contact with the top of the lamp harp. This can be fixed by using a taller harp or a shorter bulb. Note that the bulb socket height is not standard, and may vary from one lamp design to another. Harp too narrow (Figure 2) Some lamp harps may not be able to accommodate the because it is wider than a typical bulb at the base. This problem may also occur when compact fluorescent bulbs (CFLs) are used with these harps. If this problem is experienced, Lutron recommends using a lamp harp that was designed to work with CFLs. Harp not aligned (Figure 3) When screwing in the to the lamp, the knob may end up in an undesirable direction, such as facing the back of the lamp, or the direction of the may prevent proper reinstallation of the lamp harp. Correcting this problem requires re-aligning the harp with the. In some lamp designs, the bulb socket may be turned slightly by grasping the socket and applying firm force to twist the socket clockwise or counterclockwise as necessary. DO NOT apply pressure to the to twist the bulb socket. Doing so may damage the socket or Dimmer/Switch. You may need to loosen a set screw located at the base of the bulb socket in order to rotate it. Typically, the lamp harp can be rotated by firmly grasping the harp saddle and applying firm force to twist the saddle clockwise or counterclockwise as necessary. You may need to loosen a nut located between the bulb socket and harp saddle or harp saddle and lamp in order to rotate the harp saddle. Resources Lutron has tested the following lamp harps to properly fit the Lutron. This is not an exhaustive list, but is meant as a guide to help if an issue is experienced. As a convenience to our customers, Lutron offers a selection of harps available for purchase. Please contact Lutron customer service (1.888.LUTRON1) or visit www.lutronstore.com to order. Harp Size Harp Color Manufacturer Model Number Lutron Part Number 7 in (178 mm) Brass Satco 90-919 Nickel Satco 90-2000 8 in (203 mm) Brass Satco 90-920 Lutron LH-8PB Nickel Satco 90-2001 Lutron LH-8PN 9 in (229 mm) Brass Satco 90-921 Nickel Satco 90-2002 10 in (254 mm) Brass Satco 90-922 Lutron LH-10PB Nickel Satco 90-2003 Lutron LH-10PN

Dimmer Operation sz-1sd 7 07.31.09 Dimming Knob Turn clockwise to turn on and brighten Turn counter-clockwise to dim and turn off Push in to toggle on and off Distinct sounds indicate when high or low level is reached Status Indicator Indicates current load status with green indicator Green = load is switched on Green Nightlight = load is switched off Amber = device is in programming mode Red = device is experiencing an over-temperature condition Dimming knob Status indicator Over-temperature Detection If an over-temperature condition is detected, the LED on the lamp socket dimmer/switch will turn red, and the lamp socket dimmer/ switch will turn off the bulb. Proper installation and conformance to all specifications should be ensured before proceeding. To return the device to normal operation, perform the following: Cycle power to the device (unplug the lamp; cycle the circuit breaker) Within the first 2 minutes of restoring power, press and hold the dimming knob for 3 seconds. The LED should turn from red to green.

sz-1sd 8 07.31.09 System Communication Notes System Overview Dimmer Stanza RF devices must be located within 30 feet (9 m) of a Stanza device configured as a repeater. Multiple devices configured as repeaters may be necessary to provide adequate coverage. Any Stanza device can be configured as a repeater. A total of 5 devices maximum can be configured as repeaters. Devices configured as repeaters must be within 30 feet (9 m) of another device configured as a repeater. Stanza lighting controls cannot be controlled wirelessly and Stanza keypads will not function until they are addressed and programmed. 30 ft (9 m) max. from repeater device Keypad 30 ft (9 m) max. 30 ft (9 m) max. from repeater device System Limits Feature Basic System (no SZ-CI-PRG present) Maximum devices 31 100 RS232 and/or Ethernet No Yes Interface Capability PC Required for Device Replacement No Yes Advanced System (with SZ-CI-PRG present)