ACCU-THERM PLATE HEAT EXCHANGER

Similar documents
Plate Heat Exchangers. Series FP, FPDW

PLATE HEAT EXCHANGER. Installation Manual. Customer Name: Serial number: Purchase order number: Project:

James M. Pleasants Company

Plate heat exchanger. Applications General heating and cooling duties. Heating by means of steam.

Selecting TEMA Type Heat Exchangers

Alfa Laval plate technology. It s all about optimizing everything

Sondex Welded heat exchangers:

MUELLER FALLING FILM CHILLERS

V47 Series Temperature Actuated Modulating Water Valves

Sanitary Heat Exchangers. The Complete Line

Cooling Systems 2/18/2014. Cooling Water Systems. Jim Lukanich, CWT ChemCal, Inc. Grapevine, TX

Corrugated Tubular Heat Exchangers

NORMAN FILTER COMPANY PRODUCT OVERVIEW

08.08 Vic-Check Valves

GE Oil & Gas. Air Cooled Heat Exchangers. Robust and reliable for all loads and applications

FLASH TANK ECONOMIZER PRODUCT GUIDE

Rental Services Temporary Cooling - Flexible Water Hose

Sulfur Tail Gas Thermal Oxidizer Systems By Peter Pickard

RUBBER SLEEVE KNIFE GATE VALVE

Radial-axial Radial mixing is based on the premise that the fluids to be mixed enter the mixer in the correct proportions simultaneously

Goulds AF. Axial Flow Pump

Handling Corrosive or Abrasive Liquids

Originators of the Flexible Water Tube design

Specific Volume of Liquid (Column 7). The volume per unit of mass in cubic feet per pound.

Flygt Ball Check Valves

Mechanical Seal Piping Plans

Spray Nozzles. Spray Control. Spray Fabrication. Spray Analysis. A Guide to Optimizing In-Tank Agitation and Mixing Using Eductors

Refrigeration and air-conditioning. Alfa Laval s offering at a glance

SERIES ASM NEOPRENE/EPMD FLANGED SINGLE SPHERE CONNECTOR CONNECTORS. Pressures to 225 PSIG (15.51 barg) Temperatures to 230ºF (110ºC)

CONTENTS. ZVU Engineering a.s., Member of ZVU Group, WASTE HEAT BOILERS Page 2

AMERICAN Mechanical Joint Pipe For Water, Sewage or Other Liquids

Screw Plug Immersion Heaters

OHV / OHVL Type OH3 Vertical Inline Pumps ISO (API 610)

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

5.2. Vaporizers - Types and Usage

Steam System Best Practices Condensate System Piping

GE Oil & Gas. Air cooled heat exchangers Robust and reliable for all loads and applications

Electronic Flow Switches

GRUNDFOS COMMERCIAL BUILDINGS

Vacuum Systems and Heat Transfer Products

AMIPOX GRE Pipe systems. Glass Reinforced Epoxy Pipe Solutions for various Applications

Equivalents & Conversion Factors 406 Capacity Formulas for Steam Loads 407 Formulas for Control Valve Sizing

Some Criteria for Choosing a Steam Boiler for a Microbrewery

An SPX Process Equipment Operation. Universal II Industrial Series Rotary Positive Displacement ECP Pumps

REGULATORS 175/153 Series

Depend-O-Lok FxE Expansion Coupling. System No. Submitted By Spec Sect Para Location Date Approved Date. DEPEND-O-LOK FxE EXPANSION COUPLING

WASHING PROCESS OF CARGO TANKS ON TANKERS FOR TRANSPORTATION OF CRUDE OIL

LESSON 1. HEAT EXCHANGERS

Ultipleat High Flow Filter System

Sample Coolers. Water Steam Process. The largest selection of models offered by any manufacturer.

Float and Thermostatic Traps Series H, C and X

A GUIDE TO SELECTING YOUR INDUSTRIAL OVEN

Cooling and Heat Exchanger Solutions

Model 1210C Battery Powered Pump Shown. Description

Uniquely designed and engineered specifically for the pulp and paper industry.

HIGH STANDARD VALVES FOR NON-STANDARD CONDITIONS.

CHEXTER TM FITS YOUR APPLICATION, PROFITABLY

TEMA DESIGNATIONS OF HEAT EXCHANGERS REMOVABLE BUNDLE EXCHANGERS NON REMOVABLE BUNDLE EXCHANGERS SOURCE:

Gas Detection for Refining. HA University

BRAZED PLATE INSTALLATION MANUAL

Air Eliminators and Combination Air Eliminators Strainers

SAMPLE TEST QUESTIONS STEAMFITTER/PIPEFITTER - ITA WEBSITE

RING JOINT SYSTEMS 207

RMF Engineering

Goulds Paper Stock/Process Pump with Patented Intelligent Monitoring

Valve Sizing. Te chnic al Bulletin. Flow Calculation Principles. Scope. Sizing Valves. Safe Product Selection.

ORIFICE PLATES. CONCENTRIC BORE: For standard fluid conditions an Orifice Plate would have a centrally located orifice bore.

MECHANICAL & MARINE ENGINEERING COURSES. This form should be completed by the accountable who conduct courses inside or outside A.R.

Thermostatic valve Type AVTA

Oil Sight Glass BENEFITS

FLEXIBLE SOLUTIONS FOR FLUIDS AND GASES

Your Partner for Concentrated Solar Power Generation The Heart of Your Process

API Flanged Safety Relief Valves Series 526 CATALOG

WEKO-SEAL Internal Joint Sealing WEKO-SEAL. internal pipe-joint sealing

Thermal processing for drying, heating and cooling

Facility Operations Physical Safety Guidance Document

PLATE HEAT EXCHANGER. Maintenance Manual. Customer Name: Serial Number: Purchase order number: Project Name:

Automatic Back-Flushing Filter AutoFilt RF9.

CUNO High Flow Filtration Systems

Automatic Self-Cleaning Strainers

ASME Packaged Indirect Fired Water Heater

Trash Pumps Models: 56200, , 56201, , 56300, , 56301,

In-Line Air Separators

INDIAN STANDARDS FOR NATURAL GAS PIPELINE SYSTEM

Model 362A AURORA. 340A/360A Series SINGLE STAGE END SUCTION PUMPS.

Strong partners offer perfect solutions. Automatic filtration and maintenance of engine lubricating oil in diesel locomotives

CABINET. A Clean Burn Heat Exchanger provides approximately 200% more surface area for capturing combustion heat. You get more heat from less oil.

OPERATING and MAINTENANCE MANUAL SERIES 2700A CONTROL VALVE CONTENTS. INTRODUCTION...1 Scope...1 Description...1 Valve Identification...

GENERAL PROPERTIES //////////////////////////////////////////////////////

Axial and Mixed Flow Pumps for Large Volume Pumping

61W - Wafer style resilient seated butterfly valve 61L - Lugged style resilient seated butterfly valve

Review on Experimental Analysis and Performance Characteristic of Heat Transfer In Shell and Twisted Tube Heat Exchanger

Transformer oil cooler ALFA A02

PIPES AND TUBES FOR HVAC PIPING AND EQUIPMENT

Vacuum and Compressor Systems for the Chemical Process Industry

Light Duty Commercial Electric Water Heater

Nirvana. Cycling Refrigerated Dryers

COMMERCIAL HVAC CHILLER EQUIPMENT. Air-Cooled Chillers

C. starting positive displacement pumps with the discharge valve closed.

High Flow. Filtration. Performance. in a Compact Design. 3M Filtration Full Line Catalogue

Transcription:

ACCU-THERM PLATE HEAT EXCHANGER HEAT TRANSFER PRODUCTS

Accu-Therm Operation

Accu-Therm Plate Heat Exchangers Accu-Therm plate heat exchangers are designed to provide you worry-free, highly efficient heat transfer whether you are processing simple fluids, viscous solutions, or particulates. Single-pass arrangement suitable for most applications. Multi-pass arrangement for applications with low flow rates or close-approach temperatures. FLOW ARRANGEMENTS While hot and cold fluids flow in opposite directions across a single plate, the flow pattern between plates can vary. Plate heat exchanger flow patterns can be single- or multi-pass. A single-pass arrangement means each fluid flows in the same respective direction across all the plates in the unit. A multi-pass arrangement is designed so fluids can change their respective flow directions. Single-pass units are suitable for most applications, but very low flow rates or extremely close-approach temperatures may call for the multi-pass configuration. Why Use a Plate Heat Exchanger? The advantages of the Accu-Therm begin with its design. Plate heat exchangers, or PHEs, deliver greater efficiency, lower cost, easier cleaning and maintenance, and closer approach temperatures than any other heat transfer technology. Compared to spiral and shell-and-tube heat exchangers, PHEs of similar capacity also take up little floor space and are easy to expand. The vertical swingout plates allow you to pack thousands of square feet of heat transfer area into a small space, while still allowing room for future growth. Why Buy an Accu-Therm Plate Heat Exchanger? The Accu-Therm plate heat exchanger stands apart from the rest because it is available with a wide array of plate sizes and configurations. This means we can build your unit to suit your application and heat transfer requirements better than any other manufacturer. Our plates are available in sizes of less than 1 /2 square foot to more than 27 square feet (0.05-2.5 square meters). We have several plate geometries for different heat transfer effects. And there s even an exclusive free-flow plate design made especially for slurry processing. How Does the Accu-Therm Plate Heat Exchanger Work? Like PHEs in general, the Accu-Therm plate heat exchanger provides more efficient heat transfer by design. Each unit consists of a series of grooved plates that are individually gasketed and pressed tightly together by compression bolts within a frame. Fluids enter and exit the PHE through portholes in one or both ends of the frame. Within the unit, the fluid to be heated or cooled flows down one side of each plate, while the heating or cooling medium flows in the opposite direction across the other side. The great temperature difference created by these opposite flows makes the closest possible approach temperature for maximum heat transfer efficiency.

Accu-Therm Plate Heat Exchangers

Performance Guarantee Each Accu-Therm unit receives rigorous quality inspections for leaks and pressure capabilities. If your plate heat exchanger does not operate according to your exact order specifications, our factory service technicians will make the necessary adjustments immediately. On-Time Delivery Mueller has one of the best on-time shipping records in the industry. Many orders are shipped in as few as five working days; shipment of equipment with complex specifications often takes less than four weeks. Heat Transfer for Every Part of Your Process You ll find solutions to every heat transfer need within our specialized product lines. In addition to Accu-Therm plate heat exchangers, we offer our Temp-Plate line of heat transfer surfaces, including immersion and clamp-on sections and custom products. Call us for free literature on this product or to discuss how we can improve your entire heat transfer process. Plates 304 or 316 stainless steel Titanium Avesta SMO 254 Hastelloy C-276 Nickel Incoloy Monel Gaskets Nitrile (NBR) Ethylene propylene rubber (EPDM) Silicone Viton Butyl (resin cured) Hypalon MATERIALS AVAILABLE Applications AUTOMOTIVE Phosphate tank heaters, seal water coolers, plating solution cooling, paint heating, welder water cooling, induction heater cooling, hydraulic oil coolers, quench oil heat exchangers, and cooling tower isolation. BREWING Brine cooling, water heating, and wort cooling. CAUSTIC SODA Caustic coolers, acid coolers, hydrogen gas coolers, and brine heaters and coolers. CHEMICAL Process interchangers, brine heating and cooling, salt refining, process water isolation, vapor condensers, acid heating and cooling, and gas scrubber heaters and coolers. FOOD Sugar refining, fructose solution heating and cooling, whiskey recuperators, yeast coolers, starch coolers and heaters, corn syrup cooling, and edible-oil heaters and coolers. HVAC Cooling tower isolation, free cooling, heat pump systems, thermal storage systems, condenser water heat recovery, district heating and cooling, sea-water isolation, geo-thermal heating, engine cooling, lube oil cooling, fuel oil heating, generator cooling, and heating water with steam. MARINE Seawater isolation/exchanger. METAL WORKING Quench oil coolers, plating heaters and coolers, anodizer heaters and coolers, strike solution cooling, and pickling tank heating. PETROLEUM Oil refining, natural gas processing, offshore drilling, and petrochemical processing. POWER Auxiliary cooling circuit isolation, condenser water isolation, co-generation applications, geo-thermal applications, refuse burning applications, lubrication oil cooling, and diesel engine cooling and heat recovery. PULP AND PAPER Digester heaters, blowdown liquor coolers, caustic soda coolers, boiler blowdown heat recovery, white water, and black liquor heating. STEEL Scrubber coolers, jacket water coolers, slab induction heating coolers, hydraulic oil cooling, mold water cooling, refractory liner cooling, roll oil cooling, and cooling of continuous casting installations. TEXTILE Heat recovery, caustic solution heating and cooling, washers, and dye concentrate heating.

Accu-Therm Exclusive Benefits MOST EXTENSIVE SELECTION Mueller offers an extensive selection of plate heat exchangers. Accu-Therm plate heat transfer surface areas are available in sizes from less than 1 /2 square foot to more than 27 square feet (0.05-2.5 square meters). This broad selection of sizes, combined with multiple embossed patterns and varying flow capacities, guarantees the best technical solution to specific heating or cooling requirements. HIGH FLOW RATES Flows up to 16,000 gpm (60,600 lpm) are possible with the largest Accu-Therm plate heat exchanger. This high flow capacity generally eliminates the need for multiple units in large flow applications, greatly reducing installation costs. FRAME ASSEMBLY The frame assembly is a heavy-duty construction, built to very strict tolerances. This ensures optimum plate pack compression and leak prevention. MORE SQUARE FEET OF HEAT TRANSFER SURFACE A single Accu-Therm unit can have up to 25,000 square feet (2,323 square meters) of heat transfer surface. This extensive surface area, combined with high thermal efficiency, offers potential for tremendous heat transfer capacity. HEAT TRANSFER PLATE A Mueller Accu-Therm is a precisionengineered, high-quality plate. Its performance criteria includes high thermal efficiency, uniform fluid distribution, minimal fouling, clean operation, and suitability for full differential pressure rating. GASKETS Accu-Therm gaskets are designed to positively locate in gasket grooves. Also, gaskets are fabricated of carefully selected compositions to ensure trouble-free performance. The snap-in feature (available on most models) is useful for easy gasket removal and replacement. CONNECTIONS The studded port is the standard construction on all but the smallest Accu-Therm units. This design provides absolute protection for heat transfer plates under all pipe loading conditions. In addition, all studded ports can be fully lined to protect against erosion of frame material and corrosion of heat transfer plates. Lap-joint, weld-neck, and ferrule connections are available. SHROUDS Durable shrouds are standard on all Accu-Therm units and are OSHA approved. These shrouds protect plates and gaskets and help maintain a clean, distinctive appearance for the life of the heat exchanger. Shown with shroud removed. INSPECTION AND TESTING Accu-Therm units are subjected to rigorous quality assurance inspections. For example, to ensure all units are leak tight under all possible operating conditions, each circuit is independently tested at full design pressure with the other circuit open to atmosphere. Then, all circuits are tested simultaneously at full test pressure. ASME registration is available on all of our heat exchangers.

Plate Heat Exchanger Benefits HIGH EFFICIENCY HEAT TRANSFER PERFORMANCE The embossed pattern of the Mueller Accu-Therm heat transfer plates promotes high turbulence at low fluid velocities. The high turbulence results in very high heat transfer coefficients. U values of 1,500 and greater are common. REDUCED FOULING The Accu-Therm plate heat exchanger s high turbulence, uniform fluid flow, and smooth plate surface reduce fouling and the need for frequent cleaning. COMPACT SIZE Because of the high thermal efficiency and high surface density, the Mueller Accu-Therm requires 1 /5 to 1 /2 less floor space than other types of equivalent-duty heat transfer equipment. You can also service and maintain the plate heat exchanger in the same area it occupies when in operation. EASY TO INSPECT AND CLEAN By simply removing the compression bolts and sliding away the movable end frame, you can visually inspect every square inch of the Accu-Therm heat transfer surface. The unit also lends itself to easy and economical clean-in-place (CIP) procedures because the amount of retained liquid is very low. TRUE COUNTERFLOW In the plate heat exchanger, fluids flow in opposite directions, resulting in greater effective temperature differences. This reduces the amount of heat transfer surface required. CLOSE-APPROACH TEMPERATURES An important factor in regeneration and heat recovery applications is the approach temperatures of the heat transfer media. In the Accu-Therm, very close-approach temperatures of 1-2 F (0.5-1.0 C) are possible because of the true counterflow and high heat transfer efficiency of the plates. MULTIPLE DUTIES WITH A SINGLE UNIT It is possible to heat or cool two or more fluids within the same Accu- Therm unit by simply installing intermediate divider sections between the heat transfer plates. LOWER COST Plate heat exchangers are generally more economical than other types of equivalent-duty heat exchangers due to the higher thermal efficiency and lower manufacturing costs of plate heat exchangers. LIGHTWEIGHT The Accu-Therm is lighter in total weight than other types of heat exchangers because of reduced liquid volume and less surface area for a given application. EXPANDABLE The expandable feature of the Accu-Therm protects your investment. If your heat transfer requirements change, your Accu-Therm unit will not become obsolete. Instead, you can adjust the unit s thermal performance by releasing the compression bolts, rolling back the end frame, and adding or removing heat transfer plates. HIGH VISCOSITY APPLICATIONS Because the Accu-Therm induces turbulence at low fluid velocities, it has practical application for high viscosity fluids. CROSS CONTAMINATION ELIMINATED In the Accu-Therm unit, each medium is individually gasketed. The space between gaskets is vented to atmosphere, eliminating the possibility of any cross contamination of fluids. This feature makes the Accu-Therm especially ideal for applications where product contamination cannot be tolerated.

Large Selection of Plates Available ACCU-THERM PLATES Visit our web site at www.hxrx.com or www.muel.com! We re Building for the Future Paul Mueller Company is proud to offer a whole new dimension to heat exchangers. Especially suited for large HVAC and industrial applications, the new AT190 and AT200 series plates come complete with a full range of thermal length options. Now we have 8" and 12" diameter ports for your largest flow rate needs and a variety of plate lengths to meet your individual temperature requirements. 108" 96" 84" 72" 60" 48" 36" 24" 12" AT402 AT405 AT40 AT1306 AT1309 AT2508 AT 250 AT130 AT80 AT805 AT20 AT10 AT4

Plate Designs Plate Geometries Mueller Accu-Therm plates are available in several different configurations for various heat transfer effects. Your Mueller representative can recommend the best plate or plate combination for your needs. HORIZONTAL (H) Horizontal herringbone embossing. Highest heat transfer coefficients and pressure drop. COMBINATION A combination of H and V plates for an intermediate range of heat transfer coefficients and pressure drop. Horizontal Combination Vertical VERTICAL (V) Vertical herringbone embossing. Slightly lower heat transfer coefficients and pressure drop. SPECIAL PERFORMANCE (F, G, & P) Special plate geometries for custom heat transfer needs. Exclusive Free-Flow Design Competitive plate heat exchanger designs claim wide-gap advantages, but pinch points in their design can block flow and create slurry buildup. The Free-Flow s channels handle bigger particles and require less maintenance because they are a constant width. 108" 96" 84" 72" Competition Free-Flow 60" 48" 36" 24" 12" AT161FF AT40FF AT184FF AT192FF

Frame Selection Choose from the following Accu-Therm frame sizes: C FRAME Compact, cantilever-type frame for use where space is limited. Available in sizes up to the AT405. B FRAME Available for the AT20 and larger units with the capacity to hold up to 900 heat transfer plates. Complete detailed information on the installation, operation, and maintenance of the Accu-Therm plate heat exchanger is available in our instruction manual, Part No. 9804186. Call 1-800-MUELLER for immediate mailing or visit our web site at www.hxrx.com or www.muel.com. F FRAME Intermediate-size frame. Available in sizes up to the AT40.

Specifications ACCU-THERM PLATE HEAT EXCHANGER Model Height(in) Width(in) Typical Length(in) Standard Connection Size AT4 23 8 12 to 22 7 /8 1 AT10 37 14 14 1 /2 to 50 1 /2 2 AT20 56 24 20 to 159 3 /8 2 1 /2 AT402 39 1 /4 27 20 1 /2 to 159 1 /2 4 AT405 56 27 20 1 /2 to 159 7 /8 4 AT40 70 1 /4 27 33 7 /8 to 159 7 /8 4 AT805 63 36 34 5 /8 to 160 5 /8 6 AT80 85 36 34 5 /8 to 160 5 /8 6 AT1306 84 3 /4 43 50 3 /4 to 176 3 /4 10 AT1309 99 1 /2 43 50 3 /4 to 176 3 /4 10 AT130 106 3 /4 43 50 3 /4 to 176 3 /4 10 AT180 126 3 /4 54 74 to 164 14 AT2508 120 57 65 to 245 16 AT250 134 57 65 to 245 16 AT161FF 70 3 /4 29 33 5 /8 to 159 5 /8 3 AT40FF 70 1 /4 27 33 7 /8 to 159 7 /8 4 AT184FF 91 36 34 5 /8 to 160 5 /8 8 AT192FF 111 3 /4 51 7 /16 50 3 /4 to 176 3 /4 12 Based on selection: Design pressure up to 350 psi (full differential pressure rating). Design temperature up to 410 F. ASME code standard available. FREE-FLOW CONNECTIONS AND PRESSURES Model Studded Port Size*(in.) Operating Pressures AT161FF 3 up to 86 psig (6.9 bar) AT40FF 4 up to 150 psig (11.3 bar) AT184FF 8 up to 86 psig (6.9 bar) AT192FF 12 up to 86 psig (6.9 bar) * Standard studded port-type connections provide maximum cost effectiveness and are available from stock. Lap joint and weld-neck flanged connections are available at additional cost with longer delivery. Temperatures up to 300 F are available on all models. Plates MATERIALS OF CONSTRUCTION Gaskets T304 stainless steel Nitrile (NBR) T316 stainless steel Ethylene Propylene Rubber (EPDM) Titanium Silicone Avesta SMO 254 Viton Hastelloy Butyl (Resin Cured) Nickel Hypalon Incoloy All products, specifications, and features of this product are representative of the final product and are intended as reference only. We reserve the right to make alterations without notice.

Custom Designing Your PHE For assistance with custom designing a heat exchanger, contact your Mueller representative or call 1-800-MUELLER for the representative nearest you. You ll be asked to complete the following chart and fax a copy to Mueller. Our engineers will then figure the exact plate size and channel configuration you ll need. Fluid Circulated Flow Rate Temperature In Temperature Out Operating Pressure Maximum Pressure Drop Specific Heat Specific Gravity Density Viscosity Thermal Conductivity Required Gasket Material Required Plate Material ASME Code Requirements HOT SIDE COLD SIDE Submit your applications through our web site at: www.muel.com www.hxrx.com or call or fax us at: 1-800-MUELLER (683-5537) Fax: (417) 575-9885

P.O. Box 828 Springfield, Missouri 65801-0828, U.S.A. Phone: (417) 831-3000 1-800-MUELLER Fax: (417) 575-9885 www.muel.com E-mail: heattrans@muel.com International Inquiries Fax: (417) 831-6906 E-mail: international@muel.com 1998-2004 Paul Mueller Company AT-1601--10